E.E. BCD, Building Division No.-2, Ranchi
E.E. BCD, Building Division No.-2, Ranchi
work Supplying Installing, Testing and Commissioning of a power Distribution Units for Server Rack, Anti Static Flooring for Server Room, Fire Doors, Rodent Repellent System, Water Leakage Detection System, Gas Suppression System for UPS Room, Access
2026_BCD_121338_1
BCD/Bld. Div-02-02/2026-27
Open Tender
Civil Works - Buildings
Empanelment
45 days
Ranchi
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹4.6 L
21 Nov 2026
21 Nov 2026
28 Nov 2026
21 Nov 2026
27 Nov 2026
21 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying,Installation Testing & Commissioning Services for User Room, UPS Room, Server Room with 75 Inch Display Size & Type with Mutiple inputs display processors for (4 Input display) Screen Size: Minimum 75 inches (189 cm) Panel Type: Commercial-grade LED/LCD panel Resolution: 3840 × 2160 (4K UHD) Brightness: Minimum 500 nits Contrast Ratio: OEM standard for commercial signage panel Viewing Angle: 178° (H/V) or better Operation: 24×7 continuous duty cycle 2. Video & Picture Performance HDR support (HDR10 or equivalent) Anti-glare / haze treatment for professional use Landscape and portrait orientation support Color depth: 10-bit processing or higher 3. Processor & Smart Features Built-in signage SoC (System on Chip) Integrated media player without external PC Support for remote device management software Compatible with centralized display control system | |||||
| 1.01 | 4. Connectivity
HDMI inputs: Minimum 3
DisplayPort input: Minimum 1
USB ports: Minimum 2
LAN (RJ-45): 1
Wi-Fi: Built-in
Audio Out: Required
RS-232C control port for professional integration
5. Mounting & Physical Requirements
Slim industrial design suitable for control rooms / conference areas
VESA wall-mount compatibility
Necessary mounting brackets to be included
Provision for cable management
6. Power & Environmental Conditions
Power Supply: 100–240V AC, 50/60 Hz
Low power standby mode
Operating temperature suitable for Indian conditions (minimum 0–40°C)
7. Certification & Compliance
BIS certified product
Energy-efficient commercial display
OEM warranty: 1 Year | 1 | Set | - | - |
| 2Providing, Supplying, Installing, Testing and Commissioning of Main LT Power Distribution Panel and UPS Power Distribution Panel, fabricated from CRCA sheet steel, floor/wall mounted as required, dust and vermin proof, suitable for operation on 415V, 3 Phase, 4 Wire, 50 Hz AC supply system, complete with busbars of suitable current rating, MCCBs/MCBs, metering, indicating lamps, control wiring, cable alleys, earthing terminals, gland plates, danger notices, identification labels and all associated accessories, conforming to relevant IS/IEC standards and CPWD specifications, complete as required and as directed by the Engineer-in-Charge. Main LT Power Distribution Panel Supply, installation, testing and commissioning of Main LT Distribution Panel comprising the following: Incoming: 01 No. 400A, 4 Pole MCCB, draw-out type, with adequate breaking capacity corresponding to the prospective fault level of the system, complete with all standard accessories. Outgoing Feeders: 02 Nos. 250A, 4 Pole MCCBs for IT Load / UPS Input. 04 Nos. 63A, 4 Pole TPN MCBs for In-Row Cooling Units. 04 Nos. 32A, 4 Pole MCBs for small-capacity cooling units, control circuits, lighting and auxiliary loads. The panel shall be complete with suitably rated copper busbars, neutral and earth bars, interconnections, shrouding, internal wiring, engraved ferrules, terminal blocks, space heaters, ventilation arrangements and all accessories required | |||||
| 2.01 | for satisfactory operation.
UPS Power Distribution Panel (UPS-PDB) for IT Load
Supply, installation, testing and commissioning of UPS Power Distribution Panel suitable for feeding critical IT loads, complete with the following configuration:
Incoming:
01 No. 250A, 4 Pole MCCB, draw-out type, having adequate rupturing capacity as per system fault level.
Outgoing Feeders:
14 Nos. 32A, TPN MCB outgoing feeders for feeding IT Rack Power Distribution Units (PDUs).
The panel shall be complete with copper busbars, neutral and earth bars, interconnections, control wiring, identification labels, metering provisions and all accessories required for complete operation.
Power Cabling
Providing, laying, dressing, clamping, glanding, terminating, testing and commissioning of the following FRLS/XLPE insulated, PVC sheathed, stranded copper conductor power cables of approved make, including cable trays, saddles, clamps, glands, lugs, ferruling, identification tags and all accessories required for complete installation:
The scope shall include transportation, handling, installation, termination at both ends, insulation resistance testing, continuity testing, commissioning, submission of test reports and all incidental works required for completing the installation in a safe and workmanlike manner, complete in all respects and as approved by the Engineer-in-Charge. | - | - | - | - |
| 2.02 | Power Cabling | - | - | - | - |
| 2.03 | 4C x 16 Sqmm CU Flexible Cable for Cooling Unit | - | - | - | - |
| 2.04 | 1C X 120 Sqmm CU Flexible Cable for UPS Input | - | - | - | - |
| 2.05 | 5C X 6 Sqmm CU Flex Cable for Power Rack PDU | - | - | - | - |
| 2.06 | 4C X 4Sqmm CU Flexible cable | 1 | Set | - | - |
| 3Supply, Installation, Testing and Commissioning of maintenance-free Chemical Earthing System specially designed for UPS, PAC Units, Server Racks, SRC Panels and other sensitive IT/Electrical equipment, comprising copper-bonded/GI earth electrode of approved make, earth enhancement compound, HDPE/PVC earth pit chamber with cover, watering arrangement, copper Strip/wire of required size, clamps, lugs, nuts, bolts, excavation, backfilling, interconnections and all other accessories complete.The item includes all labour, materials, tools, testing of earth resistance and commissioning complete in all respects as required at site. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
F-2-02.pdf
Tender Documents • 3.69 MB
BOQ_164173.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .