| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹24.8 L+₹4.9 L (24.5%)Rejected-Finance 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹27.4 L+₹7.5 L (37.4%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 May 2022, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N AREA CHANDIGARH PIN-160003
REPAIR AND MAINTENANCE OF SUMMER AND WINTER APPLIANCES LIKE FANS, REFRIGERATOR, AC, WATER COOLERS, DEEP FREEZERS, GEYSERS AND DESERT COOLERS ETC. AT N AREA AND HALLOMAJRA UNDER GE CHANDIGARH
2022_MES_523127_1
GE/CHD-01/2022-23
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class D category b(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹60,000
Yes
24 Jun 2022
10 May 2022
1 Jun 2022
10 May 2022
30 May 2022
18 May 2022
11 May 2022 - 15 May 2022
Amount
Taking down ceiling fans of 1200/1400/1500mm sweep and make after disconnecting from ceiling rose, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp,rubeer reels with nut, bolt split pin, and shaft, sleeves, rewinding, testing, rehanging and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain thre signatures of user after satisfactory complition of work
Taking down exhaust fans of any sweep and make after disconnecting, opening up, including greasing and overhauling after replacing unserviceable spairs like bearings, bushes, capacitors, ms clamp, nut, bolt and split pin, and shaft. sleeves, rewinding, testing, refixing and making connection to ceiling rose Complete all as specified and as directed by Engineer-in-charge. Note: (i) Spares for replacement shall be measured and paid for seprately as supply only under respective items of BOQ. (ii) Technician of contractor shall visit door to door and attend complaints in respective bldg in Md Accn and obtain thre signatures of user after satisfactory complition of work
M&L rewinding to ceiling fan motor of 1200mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conducor of size 23/.0076 upto connector block ( winding wire exc 300 gm and n-exc 350gm ) Complete all as specified and as directed by Engineer-in-charge.
M&L rewinding to ceiling fan motor of 1400/1500mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves& paper , varnishing with ‘B’ class insulation varnish thimbles, connection with flexible cable of copper conductor cable of size 23/.0076 upto connector block ( winding wire exc 350 gm and n-exc 750gm ) Complete all as specified and as directed by Engineer-in-charge. Note for item No 3 & 4 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account
Supply only Ball bearing suitable for celing fans of any sweep.
Supply only gun metal bush suitable for celing fans of any sweep.
Supply only Mild steel shaft suitable for celing fans of any sweep.
Rewinding to exhaust / pedestal/ wall mounting fan motor of 225 to 380mm sweep winded with winding machine with super enameled copper winding wire of existing size including insulated sleeves , paper , varnishing with ‘B’ class insulation varnish, thimbles, connection with flexible cable of copper conductor of size 23/.0076 up-to connector block Complete all as specified and as directed by Engineer-in-charge.
All as per above item No 08 here-in –before but 450 mm sweep Note for item No 8 & 9 :--(i) The cost of cutting & taking out to existing old winding wire shall be deemed to be included in the unit rate of this item. Nothing extra shall be entertained on this account (ii) Spare parts like as Ball bearings, Bush & shaft shall be measured & paid as Supply only separately under respective item No 10 to 12 of this schedule . Fixing charges of these spare parts shall be deemed to be included in the unit rate of this item without entertaining extra cost on this account.
Supply only ball bearing suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mountin fan
Supply only gun metal bush suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mountin
Supply only mild steel shaft suitable for 225/300/350/450 mm sweep exhaust / pedestal/ wall mounting fan
M&L lathe work for taking out bush from the lower body part of ceiling fan and replacing it with suitable size of ball bearing as per matching size to shaft making necessary bearing boring, cutting, greasing, polishing of shaft Complete all as specified and as directed by Engineer-in-charge.
M&L replacement to unserviceable capacitor 4 mfd in lieu of provided with new capacitor dry type 4 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS /EPCOS /HAVELLS
M&L replacement to unserviceable capacitor 2.5/3.15 mfd in lieu of provided with new capacitor oil type 2.5/3.15 mfd suitable for 240 volt AC Complete all as specified and as directed by Engineer-in-charge. Make :- DENFOS/ INDOFOS /EPCOS/HAVELLS
Preparation surfaces, cleaning thoroughly with kerosene oil ceiling fans 1200mm/1400mm/1500mm sweep to remove only dust and any type of spots and painted with synthetic enamel paint (white colour) with help of spray gun machine, including writing MES No, complete all as specified and as directed by Engineer-in-charge.
M&L for replacement to unserviceable fan blades (set of three blades) suitable for 1200/1400/1500mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
M&L for replacement to unserviceable rusted MS rod up to 3 feet including clamp, nut, bolt, washer & split pin suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.
M&L for replacement to unserviceable rubber reels with new suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
M&L for replacement to unserviceable PVC canopy suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
M&L for replacement to unserviceable electronic regulator step type switch size low noice step control FR & UV stablized housing electronic regulator any model ( as per site requirement) suitable for any sweep ceiling fan complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of unserviceable electronic regulator with new electonic socket size step type,no radiaton low noice level,step control,FR & UV stabilizer housing regulator suitable for any sweep ceiling fan Complete all as specified and as directed by Engineer-in-charge.
Shifting only Exhaust fan any sweep,suitable for AC single phase, 240 volts, 50 Hz, connecting up including provision of PVC insulated, unsheathed copper conductor flexible cable 3core, 23/0.0076 and fixed on wall by using 4 Nos, 100 mm long, 12 mm dia bolts, nuts and washers and grouted in wall in cm(1:3) including making opening in wall of suitable) size for exhaust fan & making good to disturbed surface of wall with PCC(1:2:4) Type –B-1 or Cement mortar CM(1:3) complete all as specified and as directed by Engineer-in-Charge.
Taking down desert cooler of any make & size fixed at different site / location and repair to desert cooler to stop any type of leakage, tightening / replacing rusted screw nuts, bolts & washers with new of same size etc including floor cleaning, scraping all scales from internal & external surfaces and painted to desert cooler with two coats of synthetic enamel paint on external surface & black Japan paint on internal surfaces with help of spray gun machine including writing of MES/ SM No in 5cm height and re-fixing the desert cooler after necessary oiling and greasing of fan and water lifting pump at site/location complete all as specified and as directed by Engineer-in -Charge. NOTE : Spare partst shall be measured & paid seperatly under respective item of this schedule .
Replacement of fan motor of 1/6 HP 50Hz’s suitable 230volt AC Make: Khaitan/CG/Bajaj
Replacement of submersiable Tulu pump / water fitting pump.Make: Khaitan/CG/Bajaj
Replacement of Wooden pads ( set of three )
Replacement of 15mm bore High density polythene pipe
Replacement of PVC Water distributor 3-way
Replacement of PVC Bend right angle
Replacement of 3-Pin plug top, 5 Amp, 230volt AC
Replacement of Flexible cable copper conductor sizes 23/.0076, 3-core PVC Insulated sheathed
Replacement of 15mm bore Ball valve with float ball PTMT
Replacement of 15mm bore, 450mm to 600mm long PVC Connection pipe with PVC Union nut.
Replacement of 15mm bore stop cock PTMT Make for item No 34 to 36:-- PARYAG / SYMAT /SHAKTI
M& L for Replacement of existing unserviceable MS steel stands of desert coolers at different locations with cooler stand made out MS angle iron 35mm x 35mm x 3mm thick embedded in wall with PCC (1:2:4) type B-1 block including applying two coat synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Taking down window type Air conditioner capacity 1.5 to 2.0 Ton strip opening, general cleaning of filter, washing complete unit with detergent and chemical including re-fixing in the same opening or shifted to other opening /room complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 38 here-in-before but split type Air Conditioner 1.5 to 2.0 Ton.
All as per above item No 38 here-in-before but cassette type Air Conditioner 2.0 Ton.
Taking out PCB unit from AC’s split / window / cassette type carry to workshop for repair and refixing PCB unit after repair to existing AC complete all as specified and as directed by Engineer-in-Charge. .
Cutting and making opening in wall or cutting to steel window / glass pane make a opening for fixing of AC’s of any capacity and cover unused space with 4 mm thick PVC sheet fixed to wooden / steel frame with mild steel screw/nails complete all as specified and as directed by Engineer-in-Charge . Note :-PVC sheet shall be measured & paid separately under respective item of BOQ.
Replacement of unserviceable sealed compressor of 1.5 Ton capacity window type AC with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning & testing for leakage etc complete all as specified and directed by Engineer-in-charge Make :SRI-RAM/ TEKAM SHAH/ KIRLOSKER / WHIRLPHOOL/VOLTAS
All as per above item No 43 here-in-before but 2.0 Ton capacity window type AC.
All as per above item No 43 here-in-before but 1.5 Ton capacity split type AC.
All as per above item No 43 here-in-before but 2.0 Ton capacity split type AC.
All as per above item No 43 here-in-before but 2.0 Ton capacity cassette type type AC. Note for item No 43 to 47:--- (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured & paid separately under respective item of BOQ.
S&F for replacement of unserviceable condenser unit with new of existing make and model suitable for split type AC 1.5 Ton capacity, complete all as specified and as directed by Engineer-in-Charge Make-Voltas/whirlpool/LG/Kirlosker
All as per above item No 48 here-in-before but 2.0 Ton capacity split type AC Make-Voltas,whirlpool,LG,Kirlosker
All as per above item No 48 here-in-before but 2.0 Ton capacity cassette type AC Make-Voltas/whirlpool/LG/Kirlosker
S&F for replacement unserviceable cooling coil unit with new of existing make and model suitable for window/split type AC 1.5 Ton capacity, complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 51 here-in-before but 2.0 Ton capacity split type AC
All as per above item No 51 here-in-before but 2.0 Ton capacity cassette type AC
Recharging of gas R-22/134 in air conditioner unit window type/ split type/ cassette type 1.5 /2.0 ton complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
S&F replacement of unserviceable thermostat switch with new of existing make and model suitable for window type/ split type/ cassette type AC 1.5/2 Ton capacity, complete all as specified and as directed by Engineer-in-Charge. Make :- RENUTROL/INDFOS/BAJAJ
S&F replacement of unserviceable starting capacitor 100 -120 mfd with new suitable for window type/ split type/ cassette type AC 1.5/2 Ton capacity & water cooler of any capacity, complete all as specified and as directed by Engineer-in-Charge. Make : USHA / SIEMEN/EPCOS
S&F replacement of unserviceable running capacitor 36mfd with new suitable for window type/ split type/ cassette type AC 1.5/2 Ton capacity & water cooler of any capacity complete all as specified and as directed by Engineer-in-Charge . Make : USHA / SIEMEN/BAJAJ
S&F replacement of unserviceable front grill with new as per existing suitable for window type/ split type AC 1.5/2.ton capacity complete all as specified and as directed by Engineer-in-Charge.
S&F replacement of unserviceable blower motor with new blower motor suitable for window type AC of 1.5/2 Ton capacity as per exising capacity motor complete all as specified and as directed by Engineer-in-Charge. Make : USHA/AUE/BAJAJ
S&F replacement of unserviceable blower motor with new blower motor suitable for split type AC of 1.5/2 Ton capacity as per exising capacity motor complete all as specified and as directed by Engineer-in-Charge. Make : USHA / AUE/BAJAJ
S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 70/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge . Make :POLYCAB/ FINOLEX / HAVELLS
S&F replacement of unserviceable knob with new knob suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.
S&F replacement of unserviceable air filter with new air filter suitable for window type / split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge.
S&F replacement of unserviceable over load protector with new over load protector suitable for split type AC 1.5/2Ton capacity Complete all as specified and as directed by Engineer-in-Charge. Make :-- RENUTROL/ INDFOS
Disconnecting, opening and taking out unserviceable sealed compressor of water cooler of capacity 150/180 litres and replaced with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leakage etc complete all as specified and as directed by Engineer-in-charge. Make : SRI-RAM/ TAKAM SHAH/ KIRLOSKER .
All as per above item No 66 hereinbefore but water cooler of capacity 40/80 litres. Note for item No 66 & 67: (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. (ii) Recharging of refrigerant gas shall be measured &paid separately under respective item of BOQ.
Cleaning the system with CTC and charging the refrigerant gas R-22/134 including replacing strainer and rectification of leakage of the system from water cooler of150 litres capacity complete all as specified and as directed by Engineer-in-charge.
All as per above item No 68 here-in-before but water cooler of capacity 40/80 litres
S&F for internal wiring for water coolers 150/80/40 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers etc required for fastening to body etc complete all as specified and as directed by Engineer-in-charge. Make :- HAVELLS/ POLYCAB/FINOLEX
S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge
All as per above item No 71 here-in-before but water cooler of capacity 40/80 litre
S&F replacement of unserviceable over load protector with new over load protector suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 73 hereinbefore but water cooler of capacity 40/80 litre
S&F replacement of unserviceable fan motor with new fan motor suitable for water cooler of 150 litre capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge. Make :-- COOL-HOME/ AUE
All as per above item No 75 hereinbefore but water cooler of capacity 40/80 liter
M&L 15 mm bore self closing tap push type cast copper alloy chromium plated fixed to water cooler as in repair Complete all as specified and as directed by Engineer-in-Charge.
M&L cleaning to water coolers upto 150 ltrs capacity internal & external surfaces of suitable repairs to body & stop leakage etc, replacing unserviceable nut bolts & washers etc including preparation of external surfaces and bottom body and painted with anticorrosive synthetic enamel paint with help of spray gun machine and writing SM / MES No in 5cm height Complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 78 here-in-before but water cooler of capacity 40/80 liter
S&F replacement of unserviceable thermo-state switch with new thermo-state switch suitable for water cooler any capacity as per exisitng make Complete all as specified and as directed by Engineer-in-Charge.
Disconnecting & opening of deep freezers and taking out unserviceable sealed compressor of capacity 300/320 liters and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system arresting the leaking etc complete all as specified and as directed by Engineer-in-charge. Make :-- SRI-RAM/ TAKAM SHAH/ KIRLOSKER. Note for item No 81 & 82: (i) Contractor shall be produced original purchase voucher of original manufacturer /authorized dealer and test certificate shall be of original manufacturer to the department along with payment of RAR/Final bill. ( ii) Recharging with refrigerant gas shall be measured & paid separately under respective item of BOQ.
All as per above item No 81 here-in-before but 205 Litre
Cleaning the system with CTC and charging the refrigerant gas R-134/22 including replacing strainer and rectification of leakage of the system from deep freezer upto 320 litres capacity complete all as specified and as directed by Engineer-in-charge.
M&L for internal wiring for deep freezer upto 320 ltr capacity with PVC insulated unsheathed flexible copper conductor cable single core size 40/0.0076 fixed with terminal clips etc including replacement of screws, washers required for fastening to body etc complete all as specified and as directed by Engineer-in-charge. Make :POLYCAB/ FINOLEX / HAVELLS
S&F replacement of unserviceable starting relay assembly with new starting relay assembly suitable for deep freezer water cooler of 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge
S&F replacement of unserviceable over load protector with new over load protector suitable for deep freezer 320 litre capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge.
S&F replacement of unserviceable fan motor with new fan motor suitable for deep freezer upto 320 liter capacity as per existing make Complete all as specified and as directed by Engineer-in-Charge. Make : COOL-HOME/ AUE
Disconnecting & opening refrigerator of capacity 210/320 litre and taking out unserviceable sealed compressor and replacing with new sealed compressor of existing capacity & model including soldering of liquid /gas pipe ,cleaning the system & the leakage etc complete all as specified and as directed by Engineer-in-charge. Make :SRI-RAM/ TIKAMSHAH/ KIRLOSKER / WHIRLPOOL .
All as per above item No 88 here-in-before but 180 litres
Recharging of gas F-12 in refrigerant cap 180/210/320 litre complete including testing of leakage and testing the unit for satisfactory performance Complete all as specified and as directed by Engineer-in-Charge.
Replacement of freezer door plastic with tension spring as per existing model suitable 160/200 liter cap.
Replacement ofFruit /vegetable tray of any capacity as per existing make & model
Replacement of Pigmy lamp (bulb)
Replacement of Door liner ( Plastic ) for upto 310 liter capacity
Replacement of Door magnetic gaskest for upto 310 litre cap.
Replacement of Relay box type for any cap.
Replacement of over load protector for any Cap.
Opening to refrigerator freezer of capacity 180 to 320 ltr re-fixing the same after flushing out and removal of blockage brazing replacement of liquid line, filter and recharging to refrigerator with F-22/134 gas to obtain the desired cooling Complete all as specified and as directed by Engr-in-Charge. Note :-- Re-charging to refrigerator with R-22/134 gas shall be measured & paid separately under respective item of this schedule.
Scraping paint completely, preparing internal and external steel surfaces and applying synthetic enamel paint over a coat of red oxide primer with spray gun after filing the cavities with filler of capacity 320 litre refrigeator complete all as specified and as directed by Engr-n-Charge.
Disconnecting & taking down unserviceable geyser of 25/50 litre capacity of any make from the wall and opening carefully including descaling the inner surface by scrapping, carrying out soldering/ brazing/gas welding to prevent the leakage, filling of glass wool & replacement of any other defective spares , including replacement of required number of stainless steel screws, nuts & bolts,assembling the the same after repair work and fixing in its orginal place, connecting to water mains and electric supply, testing after repairs, complete all as specified and as directed by Engineer-in-charge. Note :spare parts and glass wool shall be measured and paid separtaly under respective items of BOQ.
Supply only glass wool of good quality as approved for 25 litre capacity of geyser complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 101 here-in-before but 50 litre capacity.
S&F replacement of unserviceable Stain less steel inner tank of 25 liter capacity geysers of existing make & model including testing after assembling & fixed at site complete all as specified and as directed by Engineer-in-Charge.
All as per above item No 103 here-in-before but 50 ltr capacity.
Replacement of unserviceable heating element with new heating elements screw/or stud type ISI marked 2000 watt 230 volts AC single phase including necessary washer, screw, nuts bolts etc complete and all as specified.
All as per above item No 105 here-in-before but 1500 watt ISI marked complete and all as specified
Replacement of unserviceable Geyser thermostat switch any type/size with new thermostat switch ISI marked of range 0-100 degree centigrade, adjustable between 70 to 100 degree centigrade with necessary washer, screws nut etc complete and all as specified
Replacement of unserviceable Safety valve
Replacement of unserviceable indicator lamp assy with new indicator lamp assy 230 volts square or round suitable for any type or make of Geyser including connecting complete and all as specified
Replacement of unserviceable 23 to 30 cm long ,10 mm bore C.P Connection with brass union
Replacement of unserviceable Gun metal non return valve ,15 mm bore
Replacement of unserviceable 45 cm long , 15mm bore PVC connection pipe with brass union both ends fixed to GI Pipe
Replacement of unserviceable Apparatus plate for Syphon Assy for 25 litre
Replacement of unserviceable Apparatus plate for Syphon Assy 50 litre
Replacement of bottom/top plates made out of MS sheet of 1mm thick made to shape of required size factory made complete fitted with machining screws duly painted with synthetic enamelled white paint complete and all as specified.
S&F sheet metal enclosure with single pole and neutral with two pin and earth plug socket including 20Amp 240 Volt including MCB SP,20Amp(C-series) as in repair complete all as specified and as directed by Engineer-in-Charge. Make : Standard/Havells/Anchor.
Replacement of Rubber O ring /gaskit for 25 ltrs
M&L for preparation of surface of geyser of 25 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of surface of geyser of 50 ltrs capacity of any make by scrapping to existing paint, filling cavities with filler (Putty) after cleaning of dust etc and applying synthetic enamel paint over a coat of red oxide primer with spray gun and writing the MES No with black paint complete all as specified and as directed by Engineer-in-Charge.
Cutting chasing in brick walls for GI tubing 15/20mm bore including making good with cement mortar 1:3, cutting not exceeding 10cm girth complete all as specified and directed by Engineer-in-charge
S&F in repair for 15mm bore long shank stop valve cast copper alloy chromium plated fancy type, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for 20mm bore stop valve cast copper alloy, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
S&F in repair for 20mm bore stop valve cast copper alloy chromium plated fancy type, long shank cup concealed high pressure with cutch or butterfly handle screwed both ends for iron pipe or union and fixed as in repair complete all as specified and as directed by Engineer-in-Charge.
S & F for 15mm bore steel water tubing medium grade, galvanised with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors including taking out unserviceable pipe complete all as specified and directed by Engineer-in-charge.
All as per above item No 124 here-in-before but 20mm bore
S&F replacement of unserviceable cable with flexible PVC insulated copper conductor cable 3 core of size 40/0.0076 for AC of any capacity complete all as specified and as directed by Engineer-in-Charge . Make :POLYCAB/ FINOLEX / HAVELLS
M&L for 4mm thick PVC sheet of white colour including,cutting & fixing around AC’s / Desert cooler for insulation purposes complete all as specified and as directed by Engineer-in-Charge. Note :-- PVC Sheet shall be measured & paid equal to window opening without deduction of cutting area for grill opening for desert cooler & AC .
LONGIA ENGINEERS
Sabhyata Electrical and Mechanicals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .