Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹61.0 L+₹11.9 L (24.2%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended being two class below eligible class |
Tender Value
₹60.5 L
EMD Value
₹1.2 L
Closing Date
20 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ CWE NO 2 DELHI CANTT-10
SPL REPAIR TO BLDG NO P-156 (UNIT COOK HOUSE) OF 629 TPT COY ASC UNDER GE (WEST) DELHI CANTT-10
2025_MES_697594_1
CWE/WEST/TOKEN-43/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE WEST DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE WEST DELHI CANTT-10
₹1.2 L
Yes
9 May 2025
12 Feb 2025
22 Mar 2025
12 Feb 2025
20 Mar 2025
6 Mar 2025
Amount
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and as directed.
Taking down old window / ventilators with frame, any description, including guard bars not exc 1.5 sqm each , complete all as specified and as directed.
S&F for anodised aluminium window and ventilator shutters, side hung type or fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S&F powder coated ( min thickness 50 micron )Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S&F aluminium powder coated sliding window comprising of sliding runner of three way aluminium frame section (weight not less than 0.80 Kg/RM) as per series-A, consisting of three sliding shutters made out of section (weight not less than 0.55 Kg/RM) with 5.5mm thick glass and wire mesh (two No sliding glass shutters and 1 No wire mesh shutter) fixed with rubber and aluminium beading including down push type locking arrangement in shutter, fixed the frame with rawl plug complete all as specified and as directed. (Note:- 1. min thickness of powder coating not less than 50 micron. 2. above item inclusive of glass and wire mesh )
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including fixing of hold fast with bed block of size 200x200x15mm in CM 1:2:4 (using 20mm graded agg) complete all as specified and as directed. .
S & F factory made 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one shop coat of pink primer complete all as specified and as directed.
S&F 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats incl one shop coat of pink primer complete all as specified and as directed.
M&L for preparation of new steel surfaces over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint (approved tint) over a coat of pink primer complete all as specified and as directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and as directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified & as directed.
S & F 300mm long aluminium alloy anodised sliding door bolt hasp staple (bolt type) and clips of sheet cast of extruded section fixing bolts and sliding bolts of extrude section complete all as specified & as directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for windows and gauzed doors) complete all as specified and as directed.
S&F figured sheet glass, 4mm thick, pin head type fixed with clips or putty complete in squares n.exc 0.50 Sqm each pane complete all as specified and as directed.
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, fixing of nuts and bolts as necessary, gusset plates, riveting, etc., conforming to Fe -290 Gde E-165 complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement joints fixed to walls incl MS clamps of suitable size made of flat iron 25x3mm including taking down old unsv pipes complete all as specified and as directed.
S&F in repair 110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement joints laid in trenches or in floors including taking down old unsv pipes complete all as specified and as directed.
S&F PVC bend/tee suitable for 110mm bore pipe complete all as specified and as directed.
Demolition of reinforced cement concrete roofs, floors (other than ground floor), beams, staircases, landing, chajjas and similar suspended work. complete all as specified and as directed.
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs, lintels supported on walls, beams and columns in floors, roofs landings, balconies canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for formwork soffits of suspended slabs such as roof slabs, floor slabs, landings, beams, columns, lintels supported on walls and similar works not exceeding 200mm thick (Horizontal or slopping with rough finished surface of concrete complete all as specified and as directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F TMT bars 6mm to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
All as per Srl item No. 26 above but TMT bars 6 mm dia and over upto and including 10mm dia as in stirrups, spacers and binders. complete all as specified and as directed.
M&L for Complete removal of existing treatment of wall/Ceiling using wire brush/mechanical/ electrical driven sanders, washing, rubbing down and stopping of painted surface including preparation old plastered surfaces on walls and applying two coat of cement base paint over a coat of alkali resistant primer incl 1mm thick white wall care putty for finishing the surface even to true aligned surface of wall/ceiling and smooth using sand papers etc complete all as specified and as directed.
M&L rendering 15 mm thick in ready mix mortar of approved make on brick work or concrete on walls , finish the surface even and smooth without using extra cement as whole or in patch incl taking down old cement plaster of any description, complete all as specified and as directed. Note:- (i) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for rendering 10 mm thick ready mix mortar of approved make on ceiling and finished even and smooth incl taking down old plaster, complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls and applying birla white putty 3 mm on wall even and smooth surface and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls applying birla white putty 3 mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls applying birla white putty 3 mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and as directed.
M&L for preparation of new plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer on ceiling complete all as specified and as directed.
M&L for preparation of old plastered surfaces and applying two coats of oil bound distemper over a coat of alkali resistance primer on ceiling complete all as specified and as directed.
Demolition of cement concrete unreinforced in ground floor and paving n.exc 15CM thickness (below or above ground level complete all as specified and as directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as specified and as directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6. complete all as specified and as directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5 mm graded agg) louvers and jallies, 25mm thick (measured solid), including all mouldings fixed to brick/concrete surfaces with cement mortar 1:4 complete all as specified and as directed.
Dismantling of floor, hearth or walling including cement mortar bedding (but not backing removing serviceable to store and rubbish off the premises complete all as specified and as directed.
M&L for Machine cut kota stone as in treads and risers (in one piece) 18-20mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl demolition of old stone slab of any description complete all as specified and as directed.
M&L for existing kota stone grinding and polishing with bees wax making glazed finish jointed with grey cement slurry complete all as specified and as directed.
M&L for Glazed ceramic colour tiles in vertical surface of size 450x 300x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:4 complete all as specified and as directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and as directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectangular) area of each tile exceeding 0.18 sq m but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer in CM 1:6, complete all as specified and as directed.
All as per item no 45 above here-in-before but in skirting/ dado complete all as specified and as directed.
M&L in repair rotational moulded polyethylene water storage tanks 1000 liters capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified including 20 mm brass valve high pressure with polythene float and fly nut complete and GI tank nipple, screwed for iron pipe complete all as specified and as directed.
M&L Laying of CPVC SDR-11 Pipes 20 mm outer dia & fittings on walls/ceiling or laying in floors complete all as specified with all brass fittings and fixed including taking down old tubing and connections, complete to walls, ceiling or laid in floor. complete all as specified and as directed.
All as per item No.50 above but 25 mm outer dia tubing.
M&L cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of cills, shelves lintel etc and cutting chases for concealed water tubing and making good ,cutting girth exc10 cm but nexc 20 cms, complete all as specified and as directed.
M&L for repairing of spalled concrete from ceiling in the following stages:- a) Preparation of existing surfaces like chipping of unsound weak / loose concrete with electric hammer or manually including tapering all edges, making square shoulders of cavities etc. n.exc 50 mm thickness removal of debries, complete all specified and as directed. b) Applying rust remover cum passivator @ 0.20kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement complete all as specified and as directed. c) Applying a epoxy based zinc rich rebar corrosion protection system @ 0.15Kg/Sqm/coat or as per manufacturer's specifications complete all as specified and as directed. d) Mixing & applying two component Epoxy resin concrete Bonding coat @ 0.40 Kg/Sqm (Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including preparation of surface by chipping and thoroughly cleaning of surface complete wherever required over new reinforcement (if required) complete all as specified and as directed. (Reinforcement will be measured and paid separately). e) Apply a pre-batched one component polymer modified cementious patch repair mortar n.exc 50mm in layer of 15mm thick each as per manufacturer instructions and complete all as specified and as directed. f) Apply aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete @ 0.10 to 0.20 kg/m2 as manufacturers instructions and complete all as specified and as directed.
M&L for Drilling and fixing NRV injection packers in RCC members including, (a) Drilling Holes: Drilling holes in structural members at the intervals as per recommendation of engineer in charge. (b) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Fixing of Packers: Insert 12 mm dia., 50~75 mm long injection packers in cleaned holes with solvent free, moisture insensitive epoxy resin based putty or equivalent. (c) Cutting of Packers: Cut the packers by cut of wheel after completion of grouting without damaging structural elements. Complete all as specified and all as per manufacturer's instructions.
M & L for shrinkage free low viscous epoxy resin based injection grout. All as per manufacturer's instructions.
M & L for Drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D(D-Dia of Bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including fixing the steel bars in position using Lokfix E75 or equivalent from SIKA/ BASF a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive Strength (EN196) >110 MPa, Flexural Strength (EN196) >40MPa, E Modulus (EN196) 10,800 MPa. or of equivalent make but excluding the cost of reinforcement, complete all as specified and as directed & all as per manufacturer's instructions.
8mm Shear Connectors
Anchoring bars for 10mm Dia
Anchoring bars for 12mm Dia
Anchoring bars for 16mm Dia
Dismantling of brick tiles or terracing tiles single layer on roof complete all as specified and as directed.
Demolition of mud phuska on roof slabs, any thickness incl cleaning of roof surfaces and removing the debris out of MOD land complete all as specified and as directed.
Scraping of old tar felt roof treatment over concrete padding of any thickness etc from roof incl finishes or junction or parapet and cleaning the surface (by mechanical means like grinder, etc) complete all as specified and as directed.
Demolition of Cement Concrete in roof padding complete all as specified and as directed.
S & F in repair 15 mm dia bib tap cast copper alloy chromium plated with capstan head handle, screwed down high pressure screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repair Vitreous china squatting pan of orissa pattern size (580 x 440mm) white with integral foot rest (excluding flushing cistern and flush pipe) complete all as specified and as directed.
S&F in repairs 15mm dia angle valve, chromium plated, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe on for unions, complete all as specified and as directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S&F in repairs 10 Ltrs capacity PVC low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket complete all as specified and as directed.
Providing and applying a non shrink, polymer modified cementations micro-concrete Rendroc RG or equivalent from SIKA/BASF having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days. product shall have A1 Class Fire Rating confirming to EN1504 cl 5.5, Thermal conductivity of 1.5W/m degree C. Renderoc RG can be applied in sections upto 100mm deep. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. complete all as per specified and as directed & all as per manufacturer's instructions. Rate is inclusive of preparatory works from item i) to item v) below, rates also includes cost of materials labour, tools and plants, cost of shuttering & scaffolding, safety arrangement quality control and testing etc. complete all as specified and as directed.
(i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed, which enables their rust removal vides item ii) below, from slabs, beams, and columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads .
(ii) Rust removal by Providing and applying Fosroc Reebaklens RR or equivalent from SIKA/ BASF, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before micro concreting or patch repair, It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth.
(iii) Anticorrosive treatment by Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale, rust free rust free surface obtained by grit blasting or suitable means, to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT complete all as specified and as directed.
(iv) Epoxy bonding for Old concrete & New concrete by providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C. Bonding agent shall have coverage not less than 2.5sqm/litres Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. Item rate is inclusive of materials all labour, tools and tackles. complete all as specified and as directed.
(v) Work will complete only after proper wet curing has been done and testing of Micro concrete cubes filled up and cured by contractor during column jacketing work (100 mm size cube crushing strength at the end of 28-day to be not less than 45 N/sq.mm) and NDT tests mandated under item "Testing of works" complete all as specified and as directed.
Applying NitoProof primer of approved quality complete all as specified and as directed & all as per manufacturer's instructions.
M & L for Waterproof coating including surface preparation and laying of geotextile layer: Providing and applying waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF manufactured by Fosroc or equivalent from SIKA/BASF by authorized applicator. Nitoproof 600 PF shall be liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. It shall be applied in two coats at coverage rate of 2kg/sm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : >400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : >50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240. 7) Root resistant : protection by screed is required. 8) Crack bridging not less than 2mm Membrane Termination shall be done at 300 mm above FFl and and secured by providing a groove cut of 10mm x 10mm & seal it with Rendered HSXtra of fosroc. System shall be applied in two coats on to a well cleaned and moisture free substrate using brush, squeegee, roller/suitable spray applied machine. The second coat shall be applied in perpendicular direction to the first, all complete as per the fosroc methodology. Rate shall include cost of surface preparation (sub item (i) below) and providing and laying of Geotextile layer (sub item (ii) below), all materials, labour, Tools & Plants, quality tests (Ponding etc.) complete in all respects as per specifications and as per direction of Engineer in charge. In addition contractor has to submit a minimum of 10 years' guarantee against lealage through water proofed Terrace. Complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) on roof padding or roof kerb or mud slops, rounded or chamfered on edges, coping, kneelers, kerb water tough and the like incl weathering, slightly rounded or chamfered angles and throatin with water proofing compound surface finished even and smooth using extra cement and Spike rolling to surfaces or making impressions/ pattern 0f 300x300 mm sqr 3 mm deep with expanded metal, of whilst the concrete is green complete all as spd & directed. (Rate of WPC shall be included in unit rate)
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S square tube supplying and fixing in opening as per specification & drawing. it shall be wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet complete all as specified and directed
S&F Factory Made Solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement fixing in the frame at site as per specifications and drawing. it shall be laminated with wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading, complete all as specified and as directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and as directed.
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets, regulators light fittings) and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specified and as directed.
M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing in & including rigid PVC conduit FRLS grade ,ISI marked ,GI flush box of suitable size and 3 mm thick hylam sheet cover for flush boxes also including provision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and earth terminal box drawn in same concealed conduit. complete all as specified and as directed.
One light/fan/bell point controlled by one way switch 5 amps.
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per above item No 78.00 but with cable 2.5 Sqmm size 1100 volts grade for One 3 Pin socket 15A Independent board
S&F of switch piano type 5 amps single pole one way complete all as specified and as directed.
S&F of switch piano type 15 amps single pole one way complete all as specified and as directed.
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and as directed.
S&F of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and as directed.
S&F of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and as directed.
Supply, laying and drawing submain wiring in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of multistranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection complete all as specified and as directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and deposit to MES store to store complete all as specified and as directed.
Hanging only ceiling fan (M.D. supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and as directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. complete all as specified and as directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 4 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 2 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB complete all as specified and as directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incomer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in repair of MCCB 100 Amp 4 pole 16 KA at 415 V with fixed thermal magnetic release complete all as specified directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and as directed.
S&F of SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and as directed.
S&F in repair of isolator TPN 63 Amp 415 V with fixed thermal magnetic release complete all as specified directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete all as specified and as directed.
Supply and fixing LED luminaries 600mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 ampere, 240 Volts complete all as specified and as directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and as directed.
M&L far Earthling complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less 'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.
M/s M M BAHL (BID ID -3261832)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .