Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.2 LAccepted-AOC 26 A TARAPURI VISHNU NAGAR YAMUNA NAGAR | YAMUNA NAGAR | YAMUNA NAGAR | HARYANA | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹94.9 L+₹3.9 L (4.29%)Rejected-Finance 71 GOLA MAHAL SADAR BAZAR BARRACKPORE KOLKATA 700120 | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹96.4 L+₹5.4 L (5.91%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹97.0 L+₹6.0 L (6.57%)Rejected-Finance 117 LENIN SARANI KOLKATA 700 013 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹100.0 L+₹8.9 L (9.83%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L5 | Rejected-Finance Higher bid value |
Tender Value
₹96.9 L
EMD Value
₹1.7 L
Closing Date
19 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri T K Nayak,IDSE
CWE (AF) KALAIKUNDA
IMPROVEMENT OF SINGLE ACCN FOR AIRMEN AT AF STN BARRACKPORE (PH-I) UNDER GE (AF) BARRACKPORE
2024_MES_655649_2
8299/BKP/E8
Open Tender
Civil Works
Item Rate
180 days
CWE AF KALAIKUNDA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) BARRACKPORE
₹1.7 L
Yes
11 Mar 2025
28 Sept 2024
21 Oct 2024
28 Sept 2024
19 Oct 2024
12 Oct 2024
Amount
Demolition of cement concrete any description and in any position and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Demolition of reinforced cement concrete of any description and in any position (Reinforement cut as required to facilitate demolition) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as directed.
Dismantling of water tanks (exc 1000 and n.exc 2000 ltrs) and removing to store all as specified
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 25 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking up or down 40 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down chowkats of frames wth shutters (without taking out off shutters from the frame) exc 1.5 sqm and n exc 4.00 sqm each including hold fasts and removing the same from site complete all as specified and as directed. (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed
Cutting holes of size exc 100 sqcm but n.exc 250 sqcm, into or through cement concrete slabs, chajjas, etc. reinforced or otherwise including cutting of reinforcement if required all as specified complete all as specified and as directed
Cutting holes of size not exc 100 sqcm into or through cement concrete slabs, chajjas, etc. reinforced or otherwise complete including cutting of reinforcement if required all as specified complete all as specified and as directed
Making good under cills or over arches, lintels and bressummers etc (for finishing holes etc) with cement mortar 1:4 including all pinning when necessary complete all as specified.
M&L for Forming mortice holes, exc. 50 cu cm but n exc 100 cu cm for balusters, newels, rag-bolts, spout holes etc. and grouting with cement mortar 1:2 after balusters, spout holes etc. are fixed complete all as specified and as directed.
Cutting openings through walls built in cement mortar for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises all as directed.
Forming jambs, etc., to openings with cement mortar 1:4 (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete all as specified.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel pin, anodised and fixed, type C-21 finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling with cement mortar (1:4) with using WPC as per manufacturers instruction over two coat of primer mixed of Latex and cement @ 1:4 (by weight) in the grooved portion and extended upto 100 mm both sides of groove complete all as specified and as directed.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps up to 10 mtr height including necessary scalfolding and safety measures complete. (i) Complete removal of the existing water proofing treatment including padding (buid in cm/concrete) and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified. and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Bushing neat cement slurry with 3.0 Kg of cement per sqm complete all as specified and as directed. (iiii) Supply and Laying, chicken wire mesh of size 12.5 mm x 0.51 mm (24 SWG) hexagonal construction including all laps, cutting and waste in fabric reinforcement to PCC roof padding including providing 40 mm thick plain cement concrete (1:2:4) type B0using 12.5 mm graded aggregates as in roof padding. (iv) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions,while padding concrete is green on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (v) Waterproofing treatment over smooth finished surfaces after application of bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384 (primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make ,(vi) providing and laying APP polymer, modified, non-woven polyester fabric of 150 grams/square metre, reinforced membrane, 3.00 mm thick, weighing 3.60 Kg / Sq M, by torch on application method, with minimum 100 mm overlap on longitudinal direction and 150 mm overlap on the transverse direction and (vii)finally applying with two coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed. Make of APP Membrane : Super Thermolay APP PL of M/s STP Ltd, Hyperplas of M/s IWL India Ltd, Hydrostop ./M/s Texsa India Ltd./M/s Fosroc / Smart care APP membrane of Asian Paints Ltd. 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be submitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for waterproofing treatment to existing RCC roof in the following steps up to 10 mtr height including necessary scalfolding and safety measures complete all as specified and as directed. (i) Complete removal of the existing water proofing treatment and removing unserviceable material exc 1500 mtr out side of MOD land complete all as directed as specified and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete (ii) Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc and Providing 15 mm thick screed bed or bedding layer of cement mortar (1:3), mixed with liquid water proofing compound as per manufactures instructions, on concrete surface of roofs or terracing and finishing surface even and smooth without using extra cement. (iii) Applying bituminous primer @ 0.40 ltrs per sqm over prepared surfaces of roof including parapet surfaces confirming to IS : 3384.(primer and membrane to be used shall be same manufacturer) prime shall be brand of Shalitex of STP or EmufalTE of M/s Texa Indian Ltd or cold stick bitumen primer of M/s IWL or equivalent make (iv) One layer of APP based polymeric membranes of approved manufacturers, 3 mm thick, weight not less than 3.6 kg/sqm, reinforced with non woven polyester fabric (weight not less than 160 gms/sqm). Polymeric membrane shall be taken to cover the thickness of slab and shall be finished by a membrane flushing. Note: (v) Laying of APP based membranes shall be done by torch application or as per manufacturer's instructions. (vi) Side overlaps shall be minimum 100 mm and the end taps shall be minimum 150 mm and sealing of all overlaps & joints as per manufacturer instruction. (vii) For parapets, membranes shall be taken to a height of minimum 60 Cm and then inserted to the parapet in a groove. The same shall be finished by a membrane flashing.(viii)finally applying with two coat of bituminous based solar reflective aluminium paint @ 125 gms / Sq M or as per manufacturer,s instructions complete all as specified and directed 3. APP membrane shall be laid and tested by the manufacturer deploying their own team under strict supervisionand Leak proof testing with ponding with water shall be done for 72 hours in presence of user representative and report shall be sumitted. Requisite 10 years guarantee certificate from manufacturer along with contractor’s certificate required to be furnished after successfully completion of testing. The submission of both certificate is mandatory before issue of completion certificate.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
M & L for precast cement concrete louvers and jallies, 35 mm thick (measured solid) in cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate including all mouldings & including 6 mm dia reinforcement as per trade pattern or TD drawing but excluding frame and fixed in position using cement mortar (1:4) complete all as specified and as directed.
M&L for Reinforced cement concrete, type A-1, 1:1.5:3 (20mm graded aggregate) as in bases for columns, basement slabs, bases of water tanks etc and mass concrete complete all as specified.
M&L for Reinforced cement concrete type A-1, 1:1.5:3 (using 20mm graded stone aggregate) as in parapet walls, retaining walls, basement walls, ballast walls and the likeand the like complete all as specified and directed.
Formwork to flat faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc; vertical or to batter for rough finished surfaces all as specified.
Formwork to flat surfaces of sides of concrete foundations, footings, platforms for water tanks, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces all as specified.
Supply and Fix, factory made rigid lam PVC door frame of size 100 mm x 50 mm, single rebated with wall thickness of extruded 5mm PVC sheet of density 780 kgs/cum , made by joining 3 Nos. heat bent PVC sheet sections. The inside section of size 90mm x 30 mm shall be made from colour PVC sheet of 5 mm thickness.The inside section shall be covered by sticking two sections of size 35mm and 6 x 45 mm made from 5mm thick plain sheet. The frame shall be mitred cut at two corners and jointed by inserting 4 Nos. 150 mm long brackets of 15mm x15 mm MS square tube. The two vertical members of door frame shall be reinforced with 40mm x 20 mm MS tubes of 19 SWG duly filled with 2nd class hardwood throughout the frame. The door frame shall be fixed to the wall using 100 mm long nikel coated dry wheet screws through the frame by using PVC fastener. Minimum 04 Nos. of screws shall be provided for each vertical member and minimum 02 Nos.for horizontal members etc. as per manufacturers specifications, fixed in opening, complete all as specified and directed.
S&F Solid WPC Door Frame of size 75mm x 50mm standard grade having density 780 kg/cum of approved plain colour, joints to be made as per mnufacturer's instructions and fixed complete all as specified and as directed.
S & F 28 to 30mm thick “FACTORY MADE MOULDED DOOR SHUTTER" consisting of solid core single leaf Flush Door of 30mm thickness, lipped with 15mm (5mm x 3) thick x 30mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30mm width on the other stiles & bottom rails. The inner panel laminated with 2mm thick Sheet of Density 700 Kg /Cbm Manufactured by an ISO-9000 certified Company, termite proof, water proof and fire resistant moulded PVC Sheet with 2, 4, 6 raised panel design in different plain and / or prelam colours on one side after routing the Moulded design on flush door and 2mm prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the PVC lipping etc. complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing complete all as specified and directed.
Supply and Fix, factory made solid panel prelam PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides plain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
Supply and fixing of aluminium sliding window three track with powder coating (minimum thickness of powder coating 50 micron) including following components / specifications complete all as specified and as directed. (i) Two leaf glazed sliding shutter and one leaf gauged (fly proofing) sliding shutter with and including three track frame (ii) Opening of windows exceeding 0.90 Sqm but not exceeding 1.50 Sqm (iii) Thickness and weight per metre length of aluminium frame and section of shutter all as shown on drawing. (iv) All vertical/ horizontal joints shall be of extruded aluminium section so as to avoid any play between jointed members. (v) All other accessories such as jointing cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, screws, etc (vi).Glazing with sheet glass 5 mm thick ordinary quality in panels of aluminium windows, , etc. fixed with glazing clips, rubber beading and EDPM gasket (vii) Mild Steel grill shall be provided of size and design as shown on drawing (viii)Stainless steel wire cloth, 0.36 mm nominal dia of wire and avergae width of aperture 1.40 mm and fixed with stainless steel wire staples. (ix) Rest all as specified in drawing no CE (AF) SZ drawing No - AF/TD/242/15 (R), Sheet No- 1/6, 2/6, 3/6, 4/6, 5/6 & 6/6 dated 14 Feb 2017 .Note for item ser No. to :- 1. Sheet glass, MS grill and stainless steel wire mesh and all other items as shown on drawing shall be included in quoated rate. 2. Mode of Measurement : Only opening size of window shall be measured. Note: Independent test report , MTC and purchase voucher shall be sumbmitted before commencement of work and same shall be submitted along with his claim of payment
S & F aluminium with powder coating (minimum thickness of powder coating 50 micron)sections for frame of doors, windows & ventilators, door partition including fabrication of frame shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified. Note : (i) Glass panes & handle will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
S&F Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and all as specified.
S&F 4.8 mm thick Sheet glass frosted or ground or obscured on one face, ordinary quality, in square n exc 0.5 sqm in each pane and fixed to aluminium frame work complete all as specified.
S&F 4.8 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified.
Glazing with sheet glass 5.5 mm thick ordinary quality in panels of aluminium windows, ventilator, door etc. fixed with glazing clips, rubber beading and EDPM gasket in square not exceeding 0.5 Sqm in each pane.
Supply and fix 12 mm thick plywood, grade BWP, type BB, with and including 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed on both sides with approved adhesive as per manufacturer’s instructions, fixed in aluminium doors complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F extruded aluminium alloy handles, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
Supply and Fix, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and with overall length of cover plate 150 mm, fixed in floor, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge.
Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height Complete all as specified and as directed.
Supply and fix mild steel TMT bars 6 to 8 mm dia., cut to length, bend to shape required including cranking, bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clipsand including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
M&L 18-20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for Machine cut Green marble slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, laid over and including 15mm thick screed bed in cement mortar 1:6 in floors complete all as specified and directed.
M&L for machine cut green marble slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, fixed over 10mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
Materials and Labour for, Digital Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic printed coloured tiles, 300 X 450 X 7-8mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Materials and Labour for rendering 15 mm thick, cement plaster, in cement mortar (1:6) on surface fair face of brickwork in walls and finishing surface even and smooth without using extra cement, complete all as specified and directed.
Materials and Labour for rendering 5 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed. Note: - Water proofing compound deemed to be inclusive in quoted rates
Material and labour for plastering 5 mm thick on fair faces of brick work or concrete surfaces (on ceiling/soffits surfaces) in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Materials and Labour for brick work with fly ash brick Class ‘B’ bricks straight or curved on plan exceeding 6M mean radius built in cement mortar (1:4), complete all as specified and directed.
M & L for brick work with fly ash brick class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for cleaning to expose corruded reinforcement of chajja/beam/slab by wire brushing, emery paper or by mechanical means and to remove all loose scale and corrosion deposit and washing complete and providing additional reinforcement TMT bars of approved make, cut to length by electro welding method and applying one coat of rust removing chemical and anti rust coating (zinc) along its full circumference up to 10 Mtr height including all necessary scaffolding and safety measures all as specified and directed. (Manufacturer name of chemical shall be : Fosroc/Sika/Pidilite/BASAF) The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
Preparation of concrete surface of chajja/beam/slab thoroughly abraded to remove all laitance, any trace of loose plaster,cement concrete , oil, grease, paints and any other materials are to be removed by wire brushing the surface. The entire surface shall then be washed thoroughly with plenty of water and then allowed to dry. Defective concrete surfaces cut back to a sound base by chipping and removed loose concrete. Smooth surfaces to achieve by chemically roughened up to 10 Mtr height including appling bond coat of epoxy bonding agent (Nito Bond) & cement in 1 : 1 ratio bonding old and new concrete on damaged surface and all necessary scaffolding and safety measures all as specified and directed. .(The cost of entire operation shall be carried out by approved manufacturers or their authorized applicator and deemed to be included in unit rate).
M&L for providiing and placing high built repair ready mix concrete (Micro concrete) grade of M-50 specification and strength conforming to ASTM- C109-99,ASTM- C 307 ,BS1881 Part 207 to expose corroded reinforcement of chajja/beam/slab with bonding agent as per manufactures instruction (Manufacturer : Fosroc/Sika/Pidilite/BASAF) proper compaction and finished to proper level upto a Average depth of 20mm with and including provision of formwork to the affected portion up to 10 Mtr height including all necessary scaffolding all as specified and directed.(entire operation shall be done by the approved manufacturer or their authorized applicator and deemed to be included in the unit rate)
Material and labour for toilet sunken floor treatment by approved applicator as under in the following steps including necessary safety measures complete. :- (a) Preparation: Preparation of RCC slabs surfaces by mechanical means to remove laitance, loose particles, dust etc all as specified. (b) Pressure grouting: Making holes/ chase opening/ groove into/ at the junctions of RCC slab/ beams to required depth and insert 1/2 inch dia PVC pipe/ pegs as nozzles at an interval of 300mm c/c and inject cement slurry admixed expanding grout admixture Cebex 100 of make FOSROC or equivalent @ 225 gm per bag of cement within the prefixed nozzles under pressure (2 to 2.5 kg/sqcm) using grouting pump to fill all possible pores and seal the nozzle holes with cement and sand mortar 1:3 mixed with Hydroproof chemical @ 5% by weight of cement. (c) Coving: Cleaning of all residues of dust and dirt at all the junctions of wall and slab after pressure grouting and dampened to reduce and limit its absorption capacity and make coving the junction of slab and vertical offsets with CM1:4 mixed with and including WPC @ 5% by weight of cement (d) Bore Packing: Preparing inside surface of core and PVC pipes by roughning using suiltable file to get better adhesion prior to packing works, cleaning surface by wire brushing followed water jet to remove all laitance or loose flaky particles and providing water tight form form on both sides of pipes for packing the holes using suitable arrangement and applying a coat of styrenebutadience based polymer coating using Nitobond SBR Latex to enhance adhesion between the packing material and other surfaces and packing the gap using Conbextra GP2 upto the surface of the bore wilst the Nitobond SBR Latex is in taccky state and then sealing with epoxy putty Nitocare VF. (e) Pond Test: Pond the slab with water for 48 hours upto 100mm and mark the seeping areas if any. Note: If seeping is found, then, treating the damp areas by injecting cement slurry mixed with expanding grouting agent Cebax 100 using pressure grouting pump again as specified. This process shall be done till seepage is arrested.
(f) Application of water proofing layer: Providing and applying two coats of high performance and ultra flexible polymeric modified elastromeric water proofing Brushbond Ultraflex of make FOSROC or equivalent. (After application of 1st coat, second coat must be applied in perpendicular direction after drying of 1st coat for 5 to 6 hrs at 30ºC) including all necessary safety measure complete all as specified and directed.(entire operation shall be done by the approved manufacturer or their authorized applicator and deemed to be included in the unit rate)
Materials and Labour for for complete removal of existing treatment by mean mechincal machine as per manufacturer instuction,s applying two coats applying Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification to old plastered surfaces on walls, over and including 1mm thick wall care putty premium quality over and including priming paint as manufacturer,s intruction and including preparation of surfaces, complete all as specified and directed.Note Work shall be executed through authorised applicator of manufacturer,s paint Paint manufacturer
M & L for applying Two 100 % Acrylic Exterior Emulsion paint as approved pattern ( colours as approved by GE) (Berger,Weather coat Advanced XP long life Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand over a coat of exterior wall primer on new concrete/wall over and including 2mm thick external wall putty in two layer surfaces up to 10 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed. Note Work shall be executed through authorised applicator of manufacturer,s paint Paint manufacturer
Material and Labour for complete removal of existing treatment by means mechnical process / Machine as directed by manfucaturer through authorised applicator of manufacturer,s and applying two coat of 100 % Acrylic Exterior Emulsion paint (Berger,Weather coat Advanced XP long life Brand/Asain Paints :Apex ultima Brand /ICI:Dulux Weather shield Max Brand/J&N:Safeguard Optima Brand painting over and including a coat of primer to old plastered or unplastered surfaces over and including 2mm thick external wall putty in two layer up to 10 Mtr height including all necessary scaffolding and safety measures complete all as specified and directed. Note Work shall be executed through authorised applicator of manufacturer,s paint Paint manufacturer
Material and Labour for complete removal of existing treatment by means mechnical process / Machine as directed and making good with putty as per existing thickness and applying three coat of white washing on the ceilings all as specified and directed
M&L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-Charge
S & F brass chromium plated shower rose 125 mm size with or without swivel joints with shower arm, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs health faucet brass chromium plated suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall 1.25 m long flexible tube and brass wall hook including making connection and fixed in position complete all as specified & as directed.
Supply and Fix in repairs, brass chromium plated soap dish, ., fixed with brass chromium plated screws, complete all as specified and directed. (Make Jaquar Cat part No. AQN-7731/Marc/Kohler)
M & L for PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S&F 2000 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) in green colour as per IS 12701: 1996 hoisted and fixed in position with and including 25mm brass ball valves high pressure with polythene float and nut with and including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and directed .
S & F in repair 25 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 75 mm, including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supply and fix 40mm bore Unplasticized PVC pipes of pressure rating 10 kgf/sq. cm, , in any length, laid in trenches or in floor Including connected fittings complete all as specified
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, fixed to walls incuding mild steel clamp not more than 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches/floor complete all as specified and directed by Engineer- in- charge .
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches/floor complete all as specified and directed by Engineer- in- charge .
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 50 mm dia, laid in trenches/floor complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends with inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends with inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends with inspection door (any angle), 50 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S&F 75 mm bore UPVC branch piece single (Single `Y'/'T') equal or unequal without access door complete all as specified and directed by Engineer- in- charge
S&F PVC (SWR) cone cap vent cowl 110mm bore conforming to IS 14735: 1999 with and including connected fittings complete all as specified
S&F PVC (SWR) cone cap vent cowl 100mm bore conforming to IS 14735: 1999 with and including connected fittings complete all as specified
S&F PVC (SWR) cone cap vent cowl 100mm bore conforming to IS 14735: 1999 with and including connected fittings complete all as specified
S&F 50 mm dia UPVC Pipes (SCH-40) as per ASTM F 438 in small lengths fixed in walls for spouts from sunken floors with and including connected fittings complete all as specified
Supplying & fixing to walls , ceiling and laid in trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying and laying of CPVC pipes 20mm dia (outer dia) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings complete and laying through authorised maufacturer,s instructions all as specified and as directed.
Supplying and laying of CPVC pipes 25mm dia (outer dia) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and laying through authorised maufacturer,s instructions all as specified and as directed.
Supplying and laying of CPVC pipes 40mm dia (outer dia) SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors including all fittings and laying through authorised maufacturer,s instructions all as specified and as directed.
Material and labour for laying of GI tubing 50 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and walls , ceiling and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . (ii) Contractor has to submit the test certificate and purchase voucher of pipes before claiming payment.
Material and labour for fixing GM globe/gate valve 25 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
Material and labour for fixing GM globe/gate valve 40 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
Material and labour for fixing GM globe/gate valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve. (ii) Contractor has to submit the test certificate and purchase voucher of valves before claiming payment.
S&F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs vitreous china squatting pan, 'Orissa" pattern, size 630 mm X 450 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge.
Supply and Fix, pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe, 15 mm bore, including taking down existing unserviceable one complete all as specified and directed.Make:Cat No.QQT-7011 of Jaquar or equivalent make of Marc/Kohler)
S & F in repairs 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993, two ways in double control, made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
Supply and Fix brass chromium plated, towel rail, 20mm dia, , 60cm long between flanges, complete all as specified and directed.Make Cat no.ACN-1111NM of Jaquar or equivalent of Marc/Kohler
Supply and Fix in repair, bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, Make:Cat No.QQT-7037 of Jaquar or equivalent make of Kohler)
Supply and Fix , bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, Make:Cat No.QQT-7037 of Jaquar or equivalent make of Kohler)
S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy angle cock as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in repair 15 mm nominal size, nonrising spindle type long body, chromium plated with long shank and cup (concealed type) as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S&F in repairs Vitreous China half stall urinal, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified.
Supply and fix Vitreous china urinal partition white of minimum size 310x700 mm complete all as specified and as directed.
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified.
S&F Waste coupling of PTMT (half or full threaded), 32mm size, suitable for urinals, (Minimum weight 32mm-45gms complete all as specified.
S&F Push tap 15mm size, any colour high pressure of PTMT screwed for iron pipe and fixed, suitable for urinals, (Minimum weight 15mm-50gms) complete all as specified.
S & F in repair 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs Counter Top (self-rimming) white basin vitreous china, white, , size 550x450x200 mm all as per catalogue No.C0431 Cascade NXT of Parryware or equivalent of Make mentioned under PS with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant complete all as specified and as directed.
Supply and Fix, brass CP fancy wall mixer with L bends (including provision of O/H shower & hand shower) for mixing hot & cold water screwed down for iron pipe 15 mm bore and fixed, with including hand shower and tube inlcuding taking out unserviceable existing one complete all as specified and directed.
Supplying, installing, testing & commissioning, storage water heater (geyser), 50 litres capacity, standing loss less than 0.562 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 3 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (j) drain plug (k) Rated Pressure 0.8 Mpa (Class1) (l) Water proof Degree (IP x 4) (m) Rated Power Input 2 KW (m) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.Make BAJAJ MODEL ARMAND/ JAQUAR/ or equivalent of USHA/AO-SMITH or Equivalent make NOTE :- (i) Contract shall submit the brochure of geyser with detail technical specification and take approval of GE before procurement. (ii) All civil work required on site for hanging the geyser and to make good to match the surface as existing to be done by contractor without any extra cost. (iii) All the necessary accessories and T&P require on site for installation of geyser shall be provided by contractor. (iv) Contractor shall submit the manufacturer warranty card to the department before claiming payment to department. (v) If extra cable (PVC insulated sheated 2.5 Sqmm x 2 core copper conductor) required on site for extension of electric supply connection from Geyser to Metal Plug socket the same (upto 3 mtr) shall be provided by the contractor without any extra cost.
M & L for cutting existing steel tubing for alterations or additions in position without taking down of pipe complete all as specified and directed (Note cutting of existing pipe to be done for insersation of geyser cold water inlet connection pipe.
M & L for screwing existing steel tubing or alterations or additions in position without taking down of pipe complete all as specified and directed
S & F stainless steel braided flexible connection pipe for hot and cold water supply for geyser, 15 mm bore, 600 mm length, 12 bar working pressure complete all as specified and as directed.
M& L for cutting existing GI pipe alteration or addition of 40/50 mm dia bore for inerstion of reducer Tee complete with all accessories all as specified and directed by Engineer-in-charge.
Taking down carefully (copper/aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators sub main wiring, light fittings etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M & L for concealed point wiring with and including single core PVC insulated, unsheathed flexible conductor (FRLSH) cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor (FRLSH) cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: (i) The chases in the wall shall be cut with elect cutter and rates of the same will deemed to be included in quoated rates (ii) The disturbed surfaces of wall shall be made good with cement plaster 1:4 including matching the surfaces with as per existing finishes and to the entire satisfaction of Engineer in Charge):- (iii)Wiring to be done as per approved colour code in IE rule. (a) One fan point/light point point controlled by one switch 5 Amps
All as per item No. 128 above but one 3 Pin 5/6 Amp socket outlet on independent board
All as per item No. 128 above here in before but one 3 Pin 5/6 Amp socket outlet on same board
All as per item No. 128 above here in before but one Exhaust fan controlled by one way switch 5/6 Amps.
All as per item No. 128 above here in before but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F (3 pin and 2 pin) switch with combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F (3 pin and 3 pin) switch with common earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F (3 pin and 2 pin) combined socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
Supply and Fix, Heavy Duty Exhaust Fan with self closing metallic louvers, 300 mm sweep, 1400 RPM, Single Phase, 230 V, 50 Hz, all as per Model “Turbo Force” of Make ‘Havells’ or equivalent Model of Make ‘Usha’ / ’Crompton Greaves’/’Almonard’ / Bajaj and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan complete all as specified and directed.
S&F Air circulator heavy duty wall mounting Fan metal body fan of 450mm sweep with air delivery 300 cum/ minute, 90 to 100 Watt, 1400 rpm, 220-240 V, 50Hz including making all electrical connections using 1.5 x 3 core flexible sheated copper conductor cable caomplete all specified directed by Eng-in-charge. Make :- Havells /Crompton/ Usha/Bajaj.
S&F LED 20 Watt tube light fitting intregated type, aluminium body with and including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Seoul, Bridge Lux, Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2400, lumen efficacy of minimum 125 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens life span of minimum 50000 working hoursr complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. . Note : Make of batten and LED tube lamp should be of same make.
Fixing only in repair LED Tube light /bulk head fittings of any description and size on wall/surface mounted fixed complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed.
S&F epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volts, C Series current carrying capacity 10 kA, incl necessary connection complete all as specified and directed.
Supply,Designing ,install, testing & commission 3 phase and neutral, 415 volts Indoor type, CPRI approved, factory made free standing, wall mounting, dust and vermin proof, cubical type LT panel size - 1000x650x250 mm fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing , double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar made of copper ETP grade suitable for 250 Amp (size of copper strip should not be less than 25x6 mm for each phase and neutral) pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:5:10, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories :
Shree Mahabir Builders (BID ID -3144086)
M/S R. K. INDUSTRIES (BID ID -3143926)
BHARUKA ENTERPRISES (BID ID -3143681)
ms singh construction (BID ID -3143878)
BHOWMICK ENTERPRISES INDIA (BID ID -3143116)
M/s Singh enterprises (BID ID -3143908)
S.M.CONSTRUCTIONS (BID ID -3144224)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .