| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.2 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being 1st lowest bidder after deducting the sch of credit of Rs. 118908.75 | |
| 2 | L2₹21.3 L+₹8,930 (0.42%)Rejected-AOC NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-AOC 2nd lowest bidder after deducting the sch of credit of Rs. 118908.75 | |
| 3 | L3₹24.5 L+₹3.3 L (15.4%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest bidder after deducting the sch of credit of Rs. 118908.75 | |
| 4 | L4₹33.1 L+₹11.8 L (55.8%)Rejected-AOC | L4 | Rejected-AOC 4th lowest bidder after deducting the sch of credit of Rs. 118908.75 |
Tender Value
₹27.8 L
EMD Value
₹55,700
Closing Date
15 Jan 2024, 6:00 pmClosed
GE (Army) Dhar Road
GE (Army) Dhar Road
REPAIR MAINT OF CEILING FAN GEYSER, ROS DESERTS COOLERS AT DHAR ROAD JINDRAH SAMNABANJ BATTAL RC PEAK AND REPAIR REWIRING OF INTERNAL ELECTRIFICATION AT SAMNABANJ RC PEAK AND BATTAL OTM ACCN UNDER GE ARMY DHAR ROAD
2023_MES_633004_1
8069/NIT-64/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Army) Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (Army) Dhar Road
₹55,700
Yes
12 Mar 2024
15 Dec 2023
17 Jan 2024
16 Dec 2023
15 Jan 2024
1 Jan 2024
Amount
Supply and fix in replacement Capacitor 4.0 mfd complete all as specified and directed by Engineer-in-charge.
Supply and fix in replacement wood wool Cooler Pad set of Three of existing size each set complete all as specified and directed by Engineer-in-charge.
Supply and fix as in replacement MS Front Show grill as per exisitng size at site complete all as specified and directed by Engineer-in-charge.
Supply and fix as in replacement PVC Pipe 1/2 " with PVC Elbow as per exisiting type & size set of three complete all as specified and directed by Engineer-in-charge.
supply and fix as in replacement Wooden ply of size 6mm thick and sheet size 3’x6’ water proof for desert cooler fixing of desert cooler/window AC complete all as specified and directed by Engineer-in-charge.
Supply and fix as in replacement Blades for 300 mm to 450 mm Cooler fan as per existing type and make complete all as specified and directed by Engineer-in-charge.
M& L for replacement of cooler fan motor of suitable for 300 mm to 450 mm blower fan single phase 240 volts of existing make including reconneting the electric mains and testing complete all as specified and directed by the Engr-in-charge.
Disconnecting the mains and Taking out the existing unserviceable cooler Water lifitng submersible pump & replace it by supply, fixing and testing new submersible Water lifting pump single phase 240 volts of existing make including reconneting the electric mains and testing complete all as specified and directed by the Engr-in-charge.
Taking down old unserviceable or rusted & junked MS Side panels & repalce it by new MS Side panel of sheet gauge not less than 18 SWG (set of three) for desert cooler as per exisiting size at site Including replacing wood wool pad honey comb type complete set of 3 pads complete all as specified and directed by Engr-in-Charge.
Disconnecting,taking down from location and dismantling the ceiling fan of size 1200/1400 mm sweep carefully for servicing by cleaning the bearing/bush and replacing the split pin and unserviceable items like bearings, bushes, rubber reel, condenser, flexible cable,PVC Connector, canopy, etc& reassembling Ceiling fan and refixing in the same or other place including connecting and testing complete all as specified and directed by Engineer-in-Charge. Note;- Replacement of unserviceable items will be measured and paid separately under relevant items of schedule.
Supply and Fixing of ball bearing of existing size for 1200/1400 mm sweep complete all as per existing type and size.
Supply and Fixing of gun metal bush of existing size & type sitable for for 1200/1400 mm sweep ceiling fan complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing of Capacitor 2.25/2.50/3.0 mfd for ceiling fan/exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing of canopy of existing size & make for 1200/1400 mm Sweep ceiling fan complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of ceiling fan Shackle & clamp assembly complete with nut, bolt, washer, Split Pin and rubber reel etc of existing size & suitable for 1200/1400mm sweep ceiling fan complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing of PVC 2 insulated single core flexible stranded copper conductor wire/cable,1.0 Sq mm size Black/Grey colour complete all as specified and directed by Engineer-in-Charge.
Disconnecting,taking down from location and dismantling the exhaust fan/ wall mounted fan/air Circulator fan of size 300/380/450 mm sweep carefully for servicing, cleaning the bearing/bush and replacing the unserviceable items like bearings, capacitor,flexible cable etc & reassembling the same and refixing in the same or other location including connecting and testing complete all as specified and directed by Engineer-in-Charge. Note;- Replacement of unserviceable items will be measured and paid separately under relevant items of schedule.
Disconnecting,taking down from location old exhaust fan & S&F new Exhaust fan AC single phase 230 volts for size 300 mm sweep, including fixing arrangement such as steel fasteners, nut, bolts, washer etc with necessary eletric connection complete all as specified and directed
Supply and Fixing ball bearing of existing size for Exhaust fan/wall mounted fan 300 /380/450 mm sweep complete all as specified and directed by Engineer-in-Charge.
Material and labour for Collecting the burnt ceiling fans including blades of any make from AGE E/M store yard/ site, taking out to reputed work shop, dismantling, removing the burnt winding and rewinding of ceiling fan 1200 mm sweep with super enamelled copper winding wire of same gauge including varnishing, baking etc.& assembling and transporting the same for fixing and testing at site complete all as specified and directed by Engineer-in-Charge.
All as per item 22 above but of size 1400 mm sweep.
S&F Ceiling Fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement including nut, bolts, washer etc, with & including necessary eletric connection with suitable copper wire up to ceiling rose inluding removing and dismentaling of old unserviceable fan any type and size and and given as sch of credit to contractor
Material and labour for Collecting the burnt Exhaust fans including blades of any make from AGE E/M store yard/ site, taking out to reputed work shop, dismantling, removing the burnt winding and rewinding of exhaust fan 300/380/450 mm sweep with super enamelled copper winding wire of same gauge including varnishing, baking etc.& assembling and transporting the same for fixing and testing at site complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparing the old painted surfaces of ceiling fan size 1200/1400 mm sweep scrapping old paint & repainting with synthetic enamal paint of approved by one coat of desired/original colour complete all as specified and directed by Engineer-in-Charge.
Disconnecting,taking down from location and S&F Exhaust fan AC single phase 230 volts for size 450 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable copper wire from ceiling rose old unserviceable exhust fan any type and size and given as sch of credit to contractor complete all as specified and directed.
Material and labour for Collecting the burnt Exhaust fans including blades of any make from AGE E/M store yard/ site taking out to reputed work shop dismantling removing the burnt winding and rewinding of Exhaust Fan/wall mounted fan/aircirculator of size 450 mm sweep complete with super enameled copper conduct winding wire of same gauge and wight insulating, varnishing, baking, including wornout bearing/bush greasing assembling and transporting the same and fixing and testing at site complete all as specified and directed by Engineer-in-Charge.
Material and labour for disconnecting from the electric mains and Taking down, opening bottom cover and inspection of storage type water heater of size 25ltrs/50 Ltrs capacity for repair & replcement of unserviceable parts after descaling water storage tank with appropriate solution, checking for leakages if any of the inner tank, cable joints,continuity, thermostat for tripping at 65/70 degree Centigrade temp including checking fusible plug if any, base plate , pipe assembly, stop cock including replacement of defective indicator lamp, rubber gasket, bolts, nuts washers etc reassembling, refixing and reconnecting the electric connections at desired location including replacing unserviceable bolts ,nuts , washers, making good disturbed surfaces complete after repair including spray painting of one coat with synthetic enamal paint of approved colour in after preparation of surface. Note : (a) Replacement of unserviceable items like heating element, Indicator lamps, thermostat, stop cock, PVC Hot and cold pipes will be measured & paid separately. (b) Labour charges for disconnection and reconnection of water and electric connections shall be deemed to be included in unit rate quoted for this items.
Supply and fix as in repair Heating element (round/ triangular) including rubber washer/PVC gasket of the following size 1.5KW of existing type & make complete all as specified and directed by Engr-in-Charge..
Supply and fix as in repair Thermostat for geyser of capacity upto 50 ltrs capacity of existing type & make complete all as specified and directed by Engr-in-Charge..
Supply & fix Electric Storage water heater of capacity 25 Ltr , 230 V energy efficient 5 star rated complete all as specified and directed by Engineer-in-charge. Including fast nut, bolt, washe complete and removing and dismentaling of old unserviceable electric storage water heater any type and size old unserviceable Electric storage heater any type and size and and given as sch of credit to contractor complete all as specified & directed.
Supply and fix as in repair Rubber Gasket for Inner Tank of capacity upto 25 Ltrs of existing type & make complete all as specified and directed by Engr-in-Charge..
Supply and fix as in repair Air release Valve for 25/50 Ltrs capacity of existing type & make complete all as specified and directed by Engr-in-Charge..
Removing of Old leaking geyser tank and supply and fixing of 25 ltr storage water heater tank as per existing shape and type complete all as specified and directed by Engr-in-Charge..
Removing of Old leaking geyser tank and supply and fixing of 50 ltr storage water heater tank as per existing shape and type complete all as specified and directed by Engr-in-Charge..
Supply and fix as in repair safety valve of existing type and complete all as specified and directed by Engr-in-Charge.
Supply and fix as in repair CP Stop Valve 15mm dia of existing type complete and make complete all as specified and directed by Engr-in-Charge.
Supply & fix Electric Storage water heater in replacement of capacity 50 Ltr , 230 V,energy efficient not lees than BEE Star rating 3, complete all as specified and directed by Engineer-in-charge inludinghanging on wall with & including Steel fastners, bolts,nuts,washers complete old unserviceable Storage water heater any type and size given as sch of credit to contractor complete all as specified and directed.
Material and Labour for Disconnecting from mains and Dismantling the unserviceable gyeser water pipe assembly (syphon system) and replacing the new water pipe assembly of existing type & make with rubber gasket for 25 Ltrs capacity (6/8 hole) complete all as specified and directed by Engr-in-Charge.
All as per item 40 above but for Geyser of Capacity 50 Litres.
Supply and fix as in repair Indicator Lamps for Geyser of capacity 25/50 Ltr existing type complete all as specified and directed by Engr-in-Charge..
Supply and fix as in repair PVC connections 15 mm size with brass or CP nuts of length up to 600 mm (hot for outlet or cold for inlet) complete all as specified and directed by Engr-in-Charge.
Supply & fix as in repair Gun Metal globe or gate Valve with iron wheel head, screwed both end of iron or GI pipe 25 mm bore complete all as specified and directed by Engr-in-Charge.
All as per item 44 above but of size 20 mm bore.
M& L for servicing of RO Plant of capacity 7 Litr per Hr including replacement of worn out pump assembly, PVC pipes, sediment pre filtr, pressure regulator, carbon filter, RO membrane, auto shut off valve if any with & including supply of new spares complete all as specified and directed by Engr-in-Charge.
All as per item 46 above but of capacity 5 Litr per hour
Supply & fix in replacement ventilating fan of size 250 mm sweep,230 Volts including cutting across/making square hole in wall suitable to house PVC body ventilating fan complete with louvers etc for bathrooms & toilets including making good disturbed surfaces complete old unserviceable ventilating fan any type and size and and given as sch of credit to contractor complete all as specified and directed
Supply and fix as in repair of solar water heating element with thermostat 3 KW incl electric connections complete all as specified and directed by Engr-In-charge
Supply & fix wall fan in replacement single phase, 230 Volts sweep 400 mm including fixing on wall with siutable steel fasteners, bolts, nuts, washers etc including making necessary electric connection complete old unserviceable wall fan any type and size given as sch of credit to contractor complete all as specified and directed
Supply and fix as in repair down rod made out of GI pipe of 15 mm bore for ceiling fan , duly arrangement of hole and cutting of pipe etc of size 30 cm long complete all as spd and directed.
Supply and fix as in replacement down rod of ceiling fan made out of GI pipe of 15 mm bore, incl drilling hole and cutting slit in pipe etc of size up to 75 cm long complete all as specified and directed by Engr-In-charge.
Supply and fix as in replacement of exhaust fan GI sheet / PVC louver suitable for size 300 mm dia circular/Square hole acrosswall for exhaust fan complete all as specified and directed by Engr-In-charge.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Supply and fixing as in repair Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed by EIC.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 42 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way complete all as specified and directed.
All as per item 25 above but of DB SPN 8 way
All as per item 25 above but of DB SPN 12 way
Supply & Fixing in replacement of DB , VTPN Distribution Box, 4 way metal double door of protection grade not less than IP 43, IK 09 fine powder coated, matt finish with best CRCA sheet, fitted with 2 nos shrouded neutral bars, 250 Amp copper insulated bus bar,2 Neutral bar, two earth bar,Din rail, confirming to IS 13032 & 8623 on surface with fastener or concealed in wall including chasing/cutting on wall and and making good as existing surfaces complete all as specified and directed.
supply and fixing in replacement of MCCB 125 Amps 16 KA with fixed thermal magnetic release with & including tinned copper spreader link 04 Nos & phase separater 04 Nos, 4pole complete all as specified and directed.
All as per item 29 above but of capacity 100 amps 16 KA.
All as per item 29 above but of capacity 63 amps 16 KA
Supply & Fixing in replacement MCB SPN, 6 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing as replacement MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply only MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and complete all as specified and directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power ) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc, removing materials to store, or keeping in safe custody for offering credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed by Engr-incharge
Material and labour for Point wiring complete (for simple and modular type ) with 1.5 sqmm single core PVC insulated heavy duty ISI Marked,FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC white non metalic PVC conduit medium grade not less than 20mm dia with all accessories like tee, straight joint, Bend etc.,laid on surface of walls,on ceiling/ etc., and including provision of PVC heavy duty Insulated FRLS copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal modular sunken box 1.2 mm thick fixed and flushed inside the walls, with 2.80 mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. for the following complete all as specified and directed by Engr-incharge
All as per item ser No 2 above but for One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
All as per item ser No 2 above but for One switch socket outlet point 3 pin 5/6 Amps on same board.
All as per item ser No 2 above but for One switch socket outlet point 3 pin 5/6 Amps on Independent board.
All as per item ser No 2 above but for One switch socket outlet point 3 pin 5/6 Amps on Independent board but just below/one side the switch board of light point in same vertical/horizontal
All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by Enge-incharge
Taking down old unserviceable/deteriorated point wiring aluminium/ copper (excluding PVC conduit) from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash complete all as specified and directed by Engr-incharge
M&L for drawing in existing conduit steel/PVC, concealed / surface ,complete with point wiring with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 2.80 mm thick laminated sheet top cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following,complete all as specified and directed by Engr-incharge
All as per item ser No 5 above but for One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
All as per item ser No 5 above but for One switch socket outlet point 3 pin 5/6 Amps on same board.
All as per item ser No 5 above but for One switch socket outlet point 3 pin 5/6 Amps on Independent board.
All as per item ser No 5 above but for One switch socket outlet point 3 pin 5/6 Amps on Independent board but below/side the switch board of light point in same vertical/horizontal
All as per item No 5 here-in-before but in exsiting concealed/surface PVC conduit for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed by Enge-incharge
S&F as replacement Angle lamp /batten holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge.
S&F in replacement of old bulk head fitting by exterior application IP 66 protection bulk head fitting LED 10 watt alongwith housing LED Panel/Lamp weather proof outdoor type alongwith covered with transparent clear sheet all as specified and directed complete all as specified and directed by Enge-incharge
S&F Wall mounted LED batten 20 Watt with 01 No LED tube rod (White/Yellow), extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv FTL fitting any type complete all as specified and directed by Enge-incharge
S&F Wall mounted LED light fitting mirror type, 10 Watt 220V decorative type White/Yellow incl integrated electronic driver and connecting up with three core flexible copper conductor including dismantling taking down unsv sketch fitting any type complete all as specified and directed by Enge-incharge
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type complete all as specified and directed by Enge-incharge
Supply & Fixing as replacement medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed by Enge-incharge
S&F as replacement Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and directed by Enge-incharge
S&F as replacement ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and directed by Enge-incharge
S&F as replacement switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and directed by Enge-incharge
S&F as replacement switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and directed by Enge-incharge
S&F as replacement socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and directed by Enge-incharge
S&F as replacement socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and directed by Enge-incharge
S&F as replacement bell push 5/6 Amps SP flush type complete all as specified and directed by Enge-incharge
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 6.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in existing PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect complete all as specified and directed by Enge-incharge Note :- 1.Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length.
M & L for sub main wiring in replacement of worn out aluminium/Copper conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade from Main Board to Energy Meter drawing in PVC conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable of copper conductor wire Flexible (Multistrand) of FR PVC insulated along with PVC flexible tube deemded to be included as one unit length.
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing colour (distumber, Oil bound, Samosem etc ) complete in all respect all as specified and directed. Note :- 1.Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately .
S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated solid aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than one metre apart including 4mm GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete.
All as per item 22 above but of size 6 Sq mm 2 core
All as per item 22 above but of size 4 Sq mm 2 core
Supply and Fix LED lamp 9 watt, 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb.
All as per Item 36 above but 12 watt
All as per Item 36 above but 15 watt
M&L for replacement of earth continuity conductor of Aluminium strip of size 25X3 mm fixed on wall as down conductor & fixed on roof as roof conductor duly mounted on & including DMC insulators grouted with Steel fasteners 0.3 Mtr apart including laying ,jointing, welding, cutting, drilling, threading etc & testing complete all as specified & diected.
M&L for laying ,jointing, welding, cutting, drilling, threading etc & testing ground conductor of GI strip in replacement of size not less than 32mmX 3.0 mm burried under soil/ in trenches/fixed to wall or recess or chases, fixed to poles or any other indicated situation for loop earthing (for connecting all earthings around any building) complete all as specified & directed.
M&L for replacement of Single pointed Air termination rod made out of 12 mm dia 300 mm long solid aluminium bar complete all as specified & directed.
M&L for replacement of Test point trminal blockmade of gun metal or phospher bronze of size 75X75X25 mm drilled & screwed including fixing with steel fasteners on wall of building complete all as specified & directed.
Supply and fix as in replacemtn of 3 Pin Plug Top 15/16A, White/Black 240V|3 Pin Top complete all as spd and directed.
Supply and fix in replacement PVC insulated overall PVC sheathed 3 Core stranded copper conductor wire of size 1.0 sqmm complete all as specified and directed by Engr-in-Charge.
All as per item No 98.00 above but of size 1.5 sqmm
All as per item No 98.00 above but of size 2.5 sqmm
FANGALIA TRADERS
PAWAN KUMAR GOVT. CONTRACTORS
GURU KRIPA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .