Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹23.7 L+₹21,303.75 (0.91%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹25.2 L+₹1.7 L (7.37%)Rejected-Finance 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹29.9 L+₹6.4 L (27.3%)Rejected-Finance 01 SARIYAPUR NAUBASTA LALGANJ PRATAPGARH UTTAR PRADESH 230129 | PRATAPGARH | UTTAR PRADESH | 230129 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹32.2 L+₹8.7 L (37.1%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
16 Jul 2020, 6:00 pmClosed
GE West Lucknow
11, Sardar Patel Marg, Lucknow Cantt
COMPREHENSIVE SERVICES INCLUDING REPAIR AND MAINT OF INTERNAL ELECTRIFICATION AND OTHER MISC WORKS AT VIVEK VIHAR COLONY UNDER GE WEST LUCKNOW
2020_MES_353925_1
GE/W/LKO/26 OF 2020-21
Open Tender
Civil Works
Item Rate
240 days
Lucknow Cantt
Class D
Cat a i
7 documents required · 7 mandatory
₹500
Ge West Lucknow
₹73,000
Yes
26 Sept 2020
18 Jun 2020
18 Jul 2020
18 Jun 2020
16 Jul 2020
3 Jul 2020
18 Jun 2020 - 2 Jul 2020
Amount
M&L for brick work with fly ash bricks, old size, class designation 75, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 including demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks, old size, class designation 75, straight or curved on plan to any radius in half brick walls built in cement mortar 1:4 including demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick wall or concrete surface including finishing the surface fair and even complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick wall or concrete surface including finishing the surface fair and even and taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for rendering 5mm thick on ceiling in cement mortar 1:3 including finishing the surface even and smooth without using extra cement and taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of new surface complete all as specified and directed.
M&L for applying three coats of white wash on ceiling including preparation of new surface complete all as specified and directed.
M&L for preparation of new surface of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for two coats of cement base paint over one coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
S&F in repair 3 mm thick sheet glass ordinary quality and glazing with oil putty not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F in repair 0.63 mm dia MS galvanised wire cloth with average width of aperature 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S&F in repair kitchen sink with drainage board made of stainless steel 1mm thick with plugs, washers, waste coupling and waste pipe, including bedding in cement mortar 1:3 to dwarf wall or fixing cantilever brackets and connecting union to waste pipe, overall size 915mmx460mm with bowl size 410x330x160mm complete all as specified and directed.
S&F in repair stainless steel kitchen plate rack (utensil rack) of size 750x600x200mm, made out of 0.63mm thick stainless steel sheet, approved design and fixed to wall with brass screws and PVC gully including all necessary fittings like nuts and bolts etc complete all as specified and directed.
S&F in repair PVC valveless, syphonic action type, low level, flushing cistern of 10 lit capacity, white, with inlet, ball valve, float valve and handle including bracket, rubber cone and flush pipe etc. and connection to pipes complete all as specified and directed.
S&F in repair vitreous china Wash basin, white, flat back type of size 550x400mm including CP waste coupling and 32mm dia waste pipe and fixing of 02 nos brackets made out of 40x40x5mm angle iron etc. complete all as specified and directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest with PVC(SWR) 'P' or 'S' trap and providing lime concrete bedding and connecting to flusing cistern complete all as specified and directed.
S&F in repair 20mm dia mild steel PVC coated curtain rod, superior quality, any colour, with end brackets and end knobs and fixed to wall with wooden plug/ PVC gully with CP screws and cup washers complete all as specified and directed.
S & F in repair Chromium plated shower rose with or without swivel joints 125mm dia with long arm including fixing to steel pipe or union complete all as specified and directed.
S&F in repair ball valve 15 mm bore high presure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight not less than 142 grams) complete all as specified and directed.
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts & rubber washers complete all as specified and directed.
S&F in repair pillar taps, brass, with capston heads, fancy type, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in repair stop valve/angle valve 15 mm nominal bore brass, fancy type, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair bib taps, Brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair PVC Syphon Kit with complete fittings for low level flushing cistern complete all as specified and directed.
S&F in repair PVC (SWR) pipe 110 mm bore, single socketed, in any length with rubber ring joints and fixed to walls complete all as specified and directed.
S&F in repair PVC (SWR) pipe 75 mm bore, single socketed, in any length with rubber ring joints and fixed to walls complete all as specified and directed.
S&F PVC(SWR) bends 110mm dia complete all as specified and directed.
S&F PVC(SWR) bends 75 mm dia complete all as specified and directed.
S&F PVC(SWR) junction 110 mm bore single (single T) equal or unequal complete all as specified and directed.
S&F PVC(SWR) junction 110 mm bore single (single T) equal or unequal complete all as specified and directed.
M&L for machine pressed rubber moulded precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment laid over and including 25 mm thick sand cushion and joints filled with fine sand including dismantling of stone slabs and tiles of any description and thickness as in floor, apron etc. laid dry or laid dry and pointed complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in roof kerbs, benching, copings, bed blocks, roof padding and padding over chajja and the like including weathering, slightly rounded or chamfered angles and throating as directed with and including necessary form work and demolition of existing cement concrete complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300 x 450 x 7mm thick in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the existing surface with & including rendering 10 mm thick in cement mortar 1:4 finished rough to fix tiles and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square or rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with & including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
Supply, fixing, laying & testing 20 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing including taking down existing GI tubing complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exc 1.50 Sqm but n. exc 4sqm each complete all as specified and directed.
Taking down shutters of any description exc. 1 Sqm but not exc. 2 Sqm each complete all as specified and directed.
M&L for 2nd class hard wood (Sal) glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. divided into squared, with plain, cham-fered or rounded, mitred and rebated sash bars, any numbers sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F factory made Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube, supplying and fixing in opening with fittings as per specification & drawing complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter 28 to 30 mm thick(stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specifications & drawings shown in section 8 of SSR Part II complete all as directed.
S&F 0.36 mm dia stainless steel wire cloth with average width of aperature 1.40 mm and fixed with stainless steel wire staples or moulded beading complete all as specified and directed.
S&F 100 mm size mild steel butt hinges, ISI marked, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed complete all as specified and directed.
S&F aluminium handles, cast type, anodised 125 mm size complete all as specified and directed.
S&F aluminum alloy anodized sliding door bolt 250 mm long with hasp and staple (bolt type) and fixing clip of sheet and cast in extruded section and fixing bolts and sliding bolt of extruded section complete all as directed and directed.
M&L for preparation of new wood or wood based surface of any description exceeding 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for washing rubbing down and stopping old/new treated plastered surface of walls including scraping where ever required and applying a layer of wall care putty base 1 mm thick on scraped surfaced and applying two coat of oil bound distemper complete all as specified and directed.
M&L preparation of old painted surface of wood and wood based material of any description area exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparing old painted surface of steel/iron of any description area exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for complete removal of existing treatment on walls including scraping where ever required and applying a layer of exterior wall putty base minimum 1 mm thick on scraped surfaced and applying two coat of cement base paint complete all as specified and directed.
M&L for preparation of old plastered or un-plastered surfaces old decorated surface) of walls including cornices pillars etc. by brooming down and cleaning and applying two coats of weather proof exterior emulsion paint on brick/concrete wall surfaces complete all as specified and directed.
M & L and Cleaning/desludging of existing septic tank, of any capacity and depth with inlet/outlet chambers including taking out sludge (both organic and inorganic matter) in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc by means of sewage sucking machine and after plugging the incoming sewer line through combined high pressure water jetting/ suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the sludge outside MD land by any means and at a place meant for the purpose by local munucipality complete all as specified and directed at site. Note:- For measurement purpose Liquid depth of septic tank shall be measured before removal of sludge.
M & L and Cleaning/desludging of existing soakage well of any capacity and depth with inlet/outlet chambers including taking out sludge (both organic and inorganic matter) in any form and other foreign matter etc viz sediment, sand, ash, grease, fibre, silt, roots or vegetation etc by means of sewage sucking machine and after plugging the incoming sewer line through combined high pressure water jetting/ suction (Vacuum) type machine mounted on LCV/HCV facility of high pressure vacuum and removing the sludge outside MD land by any means at a place meant for the purpose by local munucipality complete all as specified and directed at site.
M&L for cleaning/clearing of sewer line (including in between manholes) up to 200 mm bore sewer line of any type and any location, manholes of any depth, section, line between the sewer lines to septic tank/soak well/sump well and cleaning any type of blockage including desilting, descaling and dechocking of drain and manhole manually or by any other way and keeping the sewer line functional and removing the sludge outside MD land and at a place meant for the purpose by local munucipality complete all as specified and directed at site.
M&L for precast cement concrete 1:1.5:3 type A-1 using 20 mm graded stone aggregate as in landings, cover slabs for man holes etc. and similar works set in cement mortar 1:4 including demolition of existing cover slab complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
Taking down carefully main switches, DB's, MCB DB's of any way or rating and making good the disturbed surfaces of walls complete all as specified and directed.
Taking down old copper/ aluminium sub main wiring or service connection complete all as specified and directed
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
All as per item no 64 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per item no 64 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per item No. 64 above but for One bell/ buzzer point on an independent board controlled by one bell push
All as per item No. 64 above but for One light point controlled by two, two way 5 Amp switch
All as per item no 64 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm.
S&F Switch piano, flush type, single pole, one way 5/6 Amp 230 Volts complete all as specified and directed.
S&F Switch piano, flush type, single pole, two way 5/6 Amp 230 Volts complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 15/16 Amp, 230 volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 5/6 Amp, 230 volts complete all as specified and directed.
S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface bakelite sheet 63.50mm dia complete all as specified and directed.
S&F bell push, flush type, single pole, one way 5/6 Amp, 230 volt flush type complete all as specified and directed.
S&F Lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling fan regulator, electronic, step type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed.
S&F call bell, musical type, AC single pole, 230 volt complete all as specified and directed.
S&F in repalcement of old UNSV fittings wall/surface mounting luminaires integrated LED Batten 18W, 6000 K, 230V with aluminium housing & integrated electronic driver including and provn of connection from ceiling rose to luminaries with suitable size copper wire complete all as specified and directed.
S&F in replacement wall/surface mounting batten luminaires (Mirror Light) integrated LED Batten (2 feet) 9W, 6000 K, 230V with polycarbonate housing & integrated electronic driver complete including necessary electrical connection complete all as specified and as directed.
S&F in repair LED Building security light 25 Watt with high power LED source (>110 lumen/ watt) PDC housing, IP65 with 4 KV inbuilt surge protection driver including electrical connection with PVC three core copper flexible wire & all necessary fixing accessories such as bracket of GI pipe light grade 40 mm dia 0.60 mtr long bend to shape and MS clamps made out of MS flat 40 x 3 mm thick duly painted with two coats of synthetic enemal paint over a coat of red oxide primer fixed on wall including bolts and nuts, fixed on wall including bolts & nuts.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick, burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m deep below normal ground level, connected to galvanised earth lead wire 4.0mm dia (7.50m) by means of bolts, nuts, check nuts & washers of galvanised iron or steel, earth lead wire protected by 15mm dia GI pipe light grade, 20mm dia light grade GI pipe for watering, meshed funnel, alternate layer of charcoal and common salt complete all as SSR Item No. 19471 and shown in electrical plate No. 3 of SSR part-I with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way in lieu of CI pit cover and protection including necessary excavation and earth work complete all as specified and directed.
S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4sqmm nominal cross sectional area and one run of 4sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 20mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings, including taking down old sub main wiring complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Amp, 10 KA breaking capacity complete all as specified and directed.
S&F VTPN 4 way double door suitable for 4 pole MCCB as incoming & SP/TP MCB as outgoing 200 Amps rated Busbar, inter connection link, cable ties, earth bar etc including required civil works complete all as specified and directed. Note: MCCB & MCB to be measured and paid seprately.
S&F MCCB 63-100 Amps 415 volts, 4 pole 16 KA breaking capacity complete all as specified and directed.
S&F vertical type sheet metal enclosure for MCB DB double door type, tripple pole and neutral 4 way 415Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 4 way 415 Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 8 way 240 Volts with 200 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 40 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, tripple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, tripple pole & neutral 100 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
M&L for taking down board/fittings/fixtures but excluding light fittings identifying and rectifying the complaints pertains to internal electrification of any type and nature of Md Accn buildings such as rectification of faulty electric circuits, tightening of loose wiring/conduits, replacement of defective switch, sockets, bell push, lamp holder, fan regulator, copper wire of different sizes, LED bulb, replacement of broken hylam boards, call bell, fan/exhaust fan condensor all as directed by Engineer in charge. Notes:- (i) Cost of minor stores such as screws, clamps, insulation tapes, nuts/bolts etc shall be deemed included in the above quoted item. (ii) Spares such as switch, sockets, bell push, lamp holder, fan regulator, and copper wire, LED bulb, hylem sheet, call bell, fan/exhaust fan condensor shall be paid seperately under respective items as supply only.
Supply only Switch piano, flush type, single pole, one way 5/6 Amp 230 Volts complete all as specified and directed.
Supply only Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
Supply only socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 15/16 Amp, 230 volts complete all as specified and directed.
Supply only socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 5/6 Amp, 230 volts complete all as specified and directed.
Supply only bell push, flush type, single pole, one way 5/6 Amp, 230 volt flush type complete all as specified and directed.
Supply only lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply only ceiling fan regulator, electronic, step type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed.
Supply only call bell AC single pole 240 volt Musical Type Make: Anchor/Havells/Bajaj
Supply only rectangular laminated hylum sheet top cover for switch sockets of size 10''x12'' including cutting for fixing switch/sockets etc. complete all as specified and directed at site.
Supply only laminated hylum sheet top cover for switch sockets of size 8''x10'' including cutting for fixing switch/sockets etc. complete all as specified and directed at site.
Supply only rectangular laminated hylum sheet top cover for switch sockets of size 8''x5'' including cutting for fixing switch/sockets etc. complete all as specified and directed at site.
Supply only 1.50 Sqmm single core multistandard PVC insulated unsheathed copper cable 1100 volts grade, complete all as specified and directed.
Supply only 2.50 Sqmm single core multistandard PVC insulated unsheathed copper cable 1100 volts grade, complete all as specified and directed
Supply only 10 Sqmm single core multistandard PVC insulated unsheathed copper cable 1100 volts grade, complete all as specified and directed.
Supply only twisted twin core flexiable wire of size 23/.0076 complete all as specified and as directed.
Supply only LED bulb 7/9 Watt, B-22 base, 3000K complete all as specified and directed.
Taking down fan of any sweep from ceilings of any height and refixing the same after repairs in original position with provn of new twin core twisted PVC insulated multistranded flexible copper conductor cable of size 23/0.0076 from ceiling rose to fan complete all as specified and directed. NOTE: (i) Repair work like winding, etc. shall be measured and paid separately (ii) The rates shall be deemed to be inclusive for taking down of defective parts and fixing of new parts like bearings, capacitors, bushes etc.
All as per item No. 112 above but exhaust fan of any sweep including replacement of defective nut/bolts complete all as specified and directed.
M&L for cutting & removing the burnt winding of ceiling fan of 1200/1400mm sweep and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating and reassembling the spares complete all as specified.
All as per item No.114 above but for exhaust fan 300mm sweep.
M&L for preparation of old painted surfaces of ceiling fan of any sweep and applying two coats of synthetic enamel paint by using spray gun including taking down and refixing in same or location complete all as specified and directed.
M&L for preparation of old painted surfaces of exhaust fan of any sweep and applying two coats of synthetic enamel paint by using spray gun including taking down and refixing in same or location complete all as specified and directed.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan (Make - TATA/SKF/NBC).
Supply only bearing No.6203/6204 for ceiling/ Exhaust fan (Make - TATA/SKF/NBC).
Supply only fan condensor 2.5 mfd (Make - USHA/UNIVERSAL/Tibcon).
Supply only fan condensor 3.15 mfd (Make - USHA/UNIVERSAL/Tibcon).
Supply only gun metal bush of any size (Make - TATA/MSP).
Material & Labour for provision for mounting clamp assembly complete for ceiling fan 1200mm/1400mm sweep with clamp,bolt,nut,washers,safety/split pins and rubber bush and all as specified and as directed.
S&F in replacement exhaust fan single phase, metal body, 240 volt, 300 mm sweep complete with nuts and bolt etc and making electrical connection with PVC copper flexible wire all as directed. Note:- Old fan shall be deposited in EM store yard/store yard of PCDA)
S&F in replacement ceiling fan 1200 mm sweep, single phase, BEE star rating, 1400 RPM and making connection with twisted copper flexible wire 23/0.076 mm all as directed. Note:- Old fan shall be deposited in EM store yard/store yard of PCDA)
S&F in replacement 12 W, 160 mm dia Slim surface mounted round LED down light panel die cast body with electronic driver complete incl necessary electrical connections complete all as specified and as directed.
S&F in replacement of FTL fittings with LED batten only made up of aluminium casting 18/20/22 W of size 4 feet, single side connection having arrangement for fixing in hanging pipes from roof or fixed to wall with standard fittings and fixtures complete all as specified and directed. NOTE :- (i) Fittings wherever required will be fixed to existing pipe from ceiling. (ii) Tube rod will be measured and paid seperately.
S&F in replacement of FTL with ultra bright crystal LED tubelight, 6000 K with high efficency, Single side connection with neccessary electrical connection incl disconnection old elecronic ballast if any complete all as directed.
S&F in repairs integrated LED type Post top lantern with high power 25/30 W LED as light source, energy saving, environmental friendly, long life asethetically designed with symmetrical light distribution,spun auminium landscape lumainaire incl LED driver complete and incl neceesary electrical connection all as directed Make Havells RUBY Clear or Surya E-TOPP
M/S SIDHARTH TRADING CO.
suniltraders
GANGA TRADERS
R K CONTRACTOR AND SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .