RequiredCompliance of BoQ specification and supporting document
Eligibility Criteria
Experience
3 yrs
Min Turnover
₹3
Past Performance
30%
Fee & Financial Details
EMD Fee Amount
₹75,099
Important Dates
Last Activity
21 Apr 2023
Published
22 Mar 2023
Bid Opening
1 Apr 2023
Bill of Quantities
Item Wise
GeM BOQ Items (18 items)
Item No
Item Title
Description
Qty
Unit
Consignee
Delivery (days)
Spec
1
SOQ1
Safe dismantling of 3 phase, 4.0 Ton vertical tower AC unit (LG Make) complete with indoor & outdoor unit i/c it,s Power & control cable , Refrigerant & drain piping etc..Work include lifting and shifting of complete system i.e indoor & outdoor, its Power & control cable , Refrigerant & drain pipe etc. safely to AAI store as per site requirement & as instructed by EIC.
(Note-Item shall be executed by OEM or OEM authorized dealer/agency only).
27
Each
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
2
SOQ2
Re-Installation, testing & commissioning of 3 phase, 4.0 Ton vertical Indoor & outdoor AC unit (LG make ) i/c fixing of Power & control cable (some portion of cables may be used from dismattled cable and some may be with new cable (cables shall be provided by AAI)). Agency has to submit Installation , Testing and commissioning report from OEM or OEM authorized dealer/agency in OEM standard format after re-installation, testing & commissioning as per site requirement & as instructed by EIC.
(Note-Item shall be executed by OEM or OEM authorized dealer/agency only).
27
Each
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
3
SOQ3
Supply & fixing of refrigerant copper tubing of suitable size as per recommendation from OEM i.e M/s LG for both suction and discharge along with elastomeric nitrile rubbe insulation for tube covering of refrigerrant pipe suitable for 4.0 TR Vertical Tower AC units (LG make). Refigerrant Pipe shall be fixed with suitable size of clamp/MS hanger/MS support/ MS angle complete as per site requirement & as instructed by EIC.
750
Rmt
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
-
4
SOQ4
Safe dismantling of 3 phase, VRF AC unit (Hitachi make) complete with indoor & outdoor unit if required i/c its Power & control cable , Refrigerant & drain piping etc.Work include lifting and shifting of complete system i.e indoor unit & concerned outdoor unit if required , its Power & control cable , Refrigerant & drain pipe etc. safely to the AAI store complete as per site requirement & as instructed by EIC.
(Note-Item shall be executed by OEM or OEM authorized dealer/agency only).
7
Nos
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
5
SOQ5
Re-Installation, testing and commissioning of dismantled indoor unit & concerned outdoor unit (Hitachi Make), its Power & control cable (some portion of cables may be used from dismattled cable and some may be with new cable). (Cables shall be provided by AAI). Agency has to submit Installation and commissioning report from OEM or OEM authorized dealer/agency in OEM standard format after re-installation, testing & commissioning as per site requirement & as instructed by EIC.
(Note-Item shall be executed by OEM or OEM authorized dealer/agency only).
7
Nos
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
6
SOQ6
Supply & fixing of refrigerant copper tubing of suitable size as per recommendation from OEM, M/s Hitachi for both suction and discharge along with elastomeric nitrile rubbe insulation for tube covering of refrigerrant pipe suitable for upto 4 TR Hitachi make indoor cassette AC units. Refigerrant Pipe shall be fixed with suitable size of clamp/MS hanger/MS support/ MS angle complete as per site requirement & as instructed by EIC.
100
Rmt
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
7
SOQ7
Supply and filling of extra refrigerant gas- R410A for proper cooling of the air conditioning units as per site requirement & as instructed by EIC.
150
Kg
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
8
SOQ8
Supply and installation of 32 mm dia hard UPVC drain water pipe with all accessories like bends, couplers, tees, supports and 6/9 mm(as per OEM recommendation) thick closed nitrile rubber foam insulation i/c chiselling, making good of wall or laying on surface etc as per site requirement complete as required & as instructed by EIC.
90
Mtr
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
-
9
SOQ9
Supply and installation of 50 mm dia hard UPVC drain water pipe with all accessories like bends, couplers, tees, supports and 6/9 mm (as per OEM recommendation) thick closed nitrile rubber foam insulation i/c chiselling, making good of wall or laying on surface etc as per site requirement complete as required & as instructed by EIC.
120
Mtr
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
10
SOQ10
Supply of 2 C X 1.5 Sq. mm size cables of grade 1.1 KV, XLPE insulated, PVC sheathed,multicore with bare annealed Copper conductor armoured cable conforming to 7098 (Part 1) 1988 amended upto date.
300
Mtr
Umesh Chandra
273008,AIRPORTS AUTHORITY OF INDIA CIVILAIRPORT GORAKHPUR PIN-273008 TELEPHONE NO-0551-2271001
90
Stage Documents
Award of Contract
contract_GEMC-511687742801270.pdf
GEM_CONTRACT • 0.11 MB
Documents
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .