Director of Health Services
Directorate of Health Services
Supply of Consumables of Cardiac Catheterization Lab for GBPH, Sri Vijaya Puram
2026_DHS_21558_1
E-134111/M-17030/102/25/CMS/56
Open Tender
Consumables (Hospital / Lab)
Supply
365 days
Directorate of Health Services
Please refer Tender documents.
13 documents required · 13 mandatory
₹0
₹9.4 L
Yes
21 Jan 2026
21 Jan 2026
11 Feb 2026
21 Jan 2026
11 Feb 2026
21 Jan 2026
21 Jan 2026 - 28 Jan 2026
PUNCTURE NEEDLES (ADULTS)
PUNCTURE NEEDLE FOR VASCULAR ACCESS IN ADULTS • 18 G • 6- 7.5 cm long • Should be compatible with 0.038 inch guide wire • Should be supplied individually packed • Needle should have protective plastic tube covering
PUNCTURE NEEDLE DEDICATED FOR RADIAL ARTERY ACCESS IN ADULTS • 20- 22 G • 3- 5 cm long • Should be compatible with 0.021 - 0.025 inch guide wire • Should be supplied individually packed • Needle should have protective plastic tube covering
MICROPUNCTURE NEEDLE FOR VASCULAR ACCESS IN ADULTS • 20- 22 G • 6- 7.5 cm long • Should be compatible with 0.018 inch guide wire • Should be supplied individually packed • Needle should have protective plastic tube covering
MICROPUNCTURE NEEDLE FOR RADIAL ARTERY ACCESS IN ADULTS • 20-22 G • 3-5 cm long • Should be compatible with 0.021-0.025 inch guide wire • Should be supplied individually packed • Needle should have protective plastic tube covering
INTRODUCER SHEATHS (ADULTS)
INTRODUCER SHEATH FOR ADULTS and pediatrics (Sizes 4 -9Fr.) - Standard Length • Sizes 4- 9 Fr • 10- 11 cm long • 0.035 or 0.038 inch guide wire compatible • With haemostatic valve to prevent back leak of blood and aspiration of air • Integrated side arm with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
INTRODUCER SHEATH WITH PUNCTURE NEEDLE FOR ADULTS (Size 5- 9 Fr) - Standard Length • Sizes 5- 9 Fr • 10-11 cm long • Pack MUST include 18 G, 6- 7.5 cm long puncture needle • 0.035 or 0.038 inch guide wire compatible • With haemostatic valve to prevent back leak of blood and aspiration of air • Integrated side arm with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
LONG INTRODUCER SHEATH (Size 6- 7Fr) – 20-50 CM LONG • Sizes 6- 8Fr • Sheath should be between 20-50 cm long • 0.035 or 0.038 inch guide wire compatible • With haemostatic valve to prevent back leak of blood and aspiration of air • Integrated side arm with attached 3-way stopcock • With suture eye for securing sheath • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
INTRODUCER SHEATH FOR RADIAL ACCESS INTRODUCER SHEATH DEDICATED FOR TRANSRADIAL ACCESS • Sizes 4- 7 Fr • Between 7- 16 cm long • 0.021 - 0.025 inch guide wire compatible • Pack MUST include 20-22 G, 3.5 cm long puncture needle • With haemostatic valve to prevent back leak of blood and aspiration of air • Integrated side arm with attached 3-way stopcock • With suture eye for securing sheath • M coat hydrophilic coating • Kink resistant • With dilator-hub lock mechanism to prevent its back-out during insertion • With smooth and resistance free insertion
INTRODUCER SLENDER SHEATH FOR RADIAL ACCESS • TRANSRADIAL SLENDER SHEATH SYSTEMS 5F 10 cm • capable of introducing 6F catheter with hydrophilic coating on sheath ,tapering dilator • hydrophilic straight polymer 0.025 wires and 20G plastic cannula for puncture . • Should be FDA'/CE'/DCGI approved
INTRODUCER SLENDER SHEATH FOR RADIAL ACCESS • TRANSRADIAL SLENDER SHEATH SYSTEMS 6F 10 cm • capable of introducing 7F catheter with hydrophilic coating on sheath, tapering dilator • hydrophilic straight polymer or stainless steel 0.021 or 0.025 wires and 22 G / 20G plastic cannula for puncture • Should be FDA'/CE'/DCGI approved
GUIDEWIRES (ADULTS)
PTFE COATED DIAGNOSTIC GUIDE WIRE - REGULAR LENGTH, REGULAR STIFFNESS • Should be available in 0.025, 0.032, 0.035 and 0.038 inches size • Should be between 145- 180 cm long • Should be available as straight & J shape tip • Should be available in variable lengths of flexible/floppy end • Should be available in variable J tip sizes • Should be available in fixed as well as movable core
PTFE COATED DIAGNOSTIC GUIDE WIRE - EXCHANGE LENGTH, REGULAR STIFFNESS • Should be available in 0.025, 0.032, 0.035 and 0.038 inches size • Should be 240- 300 cm long • Should be available as straight or J shape tip • Should be available in fixed as well as movable core
PTFE COATED DIAGNOSTIC GUIDE WIRE - REGULAR LENGTH, EXTRA-STIFF SHAFT STRENGTH - AMPLATZ TYPE • Should be available in 0.035 inches size and higher • Should be 145- 180 cm long • Should be available as straight & J shape tip
PTFE COATED DIAGNOSTIC GUIDE WIRE – exchange LENGTH, EXTRA-STIFF SHAFT STRENGTH - AMPLATZ TYPE • Should be available in 0.035 inches size and higher • Should be 240- 300 cm long • Should be available as straight & J shape tip
HYDROPHILIC COATED DIAGNOSTIC GUIDE WIRE – Regular length/ EXCHANGE LENGTH, REGULAR STIFFNESS • Should be available in 0.018 ,0.025, 0.032, 0.035 and 0.038 inches size • Should be available as straight or J shape tip • Should be 120,150,180,260 cm long • Core-to-tip design providing a 1:1 torque ratio
HYDROPHILIC COATED DIAGNOSTIC GUIDE WIRE – for radial access • nitinol alloy core for tracking in tortuous anatomy, • 180,260 cm long & 1.5mm J-Tip Guidewire
DIAGNOSTIC CATHETERS (ADULTS)
PIGTAIL CATHETER - FDA APPROVED • Sizes 5- 7 Fr • Must be FDA/CE'/DCGI approved • Should be available in various lengths
JUDKINS DIAGNOSTIC CORONARY ANGIOGRAPHY CATHETER- FDA APPROVED
MULTIPURPOSE DIAGNOSTIC CORONARY ANGIOGRAPHY CATHETER- FDA APPROVED
AMPLATZ DIAGNOSTIC CORONARY ANGIOGRAPHY CATHETER- FDA APPROVED
INTERNAL MAMMARY DIAGNOSTIC CORONARY ANGIOGRAPHY CATHETER - FDA APPROVED
BY- PASS GRAFT DIAGNOSTIC CORONARY ANGIOGRAPHY CAHETERS- FDA APPROVED
DIAGNOSTIC CATHETERS (ADULTS) – SPECIAL & TRANS-RADIAL USE CATHATERS
TRANSRADIAL DIAGNOSTIC CORONARY ANGIOGRAPHY CATHETERS - FDA APPROVED
SPECIAL TRANSRADIAL DIAGNOSTIC CORONARY ANGIOGRAPHY CATHETER - FDA APPROVED
PTCA ACCESSORIES
PTCA INFLATION DEVICE- ANALOG DISPLAY
Y CONNECTOR FOR PTCA – ROTATION TYPE
Y CONNECTOR FOR PTCA – PUSH AND PULL TYPE
Y CONNECTOR WITH EXTENSION TUBING (HAEMOSTATIC Y- CONNECTOR WITH EXTENSION TUBING) FOR PTCA- ROTATING MECHANISM
PTCA GUIDE WIRE TORQUER
PTCA GUIDE WIRE INSERTION NEEDLE
PTCA INFLATION DEVICE WITH ACCESSORY KIT CONTAINING
DISPOSABLE PLASTIC STERILE LUER LOCK SYRINGE FOR ANGIOGRAPHY AND PTCA
MANIFOLD WITH TWO SIDE PORTS FOR ANGIOGRAPHY AND PTCA
MANIFOLD WITH THREE SIDE PORTS FOR PTCA
CONNECTOR TUBING (CONNECTING BETWEEN Y connector AND MANIFOLD) WITH ATTACHED THREE WAY STOP COCK
Short connecting pressure line of 100-150 cm with male port in one side and female port in the other side
High pressure injector line to withstand pressure up to 1200 psi, 75-150 cm length with luer lock male port and rotator
GUIDING CATHETERS FOR PTCA
LARGE LUMEN PTCA GUIDING CATHETERS OF 6 -8 FRENCH SIZES – FDA/CE/DCGI APPROVED
LARGE LUMEN PTCA GUIDING CATHETERS OF 6 -8 FRENCH SIZES – FDA/CE/DCGI APPROVED
PTCA GUIDING CATHETER DEDICATED FOR TRANSRADIAL INTERVENTIONS- FDA APPROVED
PTCA - COAXIAL FLEXIBLE GUIDE CATHETER EXTENSION ASSEMBLY FOR ENHANCING GUIDE SUPPORT IN COMPLEX CORONARY INTERVENTIONS (GEC )
Coronary guide extension catheter
PTCA GUIDEWIRES
PTCA GUIDE WIRE - REGULAR SHAFT SUPPORT AND FLOPPY TIP
SPECIAL PTCA GUIDE WIRE HAVING FUSED STAINLESS STEEL AND NITINOL CORES
Workhorse frontline guide wire with a ACT ONE and Nitinol tip
PTCA WIRES Floppy Extra support
Frontline guide wire construction for excellent tip durability and torque performance in tight anatomy
SPECIAL POLYMER COATED PTCA GUIDE WIRE WITH DISTAL SPRING COIL HAVING
SPECIAL POLYMER COATED TAPERING PTCA GUIDE WIRE WITH DISTAL SPRING COIL HAVING
SPECIAL PTCA GUIDE WIRES WITH TIP MADE UP OF MULTIPLE STIFF AND FLEXIBLE COMPONENTS
SPECIAL ‘PTCA GUIDEWIRE DEDICATED FOR PCI OF COMPLEX CHRONIC TOTAL OCCLUSION
PTCA WIRE FOR COLLATERAL CROSSING WITH TIP LOAD OF 0.3 GM. Should be FDA'/CE'/DCGI approved
Dedicated guidewire for externalization in retrograde PTCA with length >300 cm. FDA'/CE'/DCGI approved
PTCA extension wire/ Doc wire
PTCA BALLOONS
PTCA BALLOON (SEMI-COMPLIANT) – FDA and CE/DCGI APPROVED
PTCA BALLOON (NON-COMPLIANT) – FDA and CE /DCGI APPROVED
SPECIAL PTCA BALLOON (NON-COMPLIANT) – FDA and CE/DCGI APPROVED
SPECIAL PTCA BALLOON CATHETER WITH - ultra low profile balloon designed for treating CTO and complex lesions- FDA and CE/DCGA APPROVED
SPECIAL PTCA BALLOON CATHETER WITH -low profile balloon designed for treating CTO and complex lesions- FDA/CE APPROVED
SCORING BALLOON CATHETER FOR PTCA
Cutting Balloon
CORONARY intravascular Lithotripsy balloons
CORONARY TRAPPER CATHETER
MICROCATHETER , Aspiration Catheters, Snares
Coronary Microcatheter – Fda/Ce/Dcgi Approved
Complex channel or micro-channel crossing catheter with hydrophilic coating of distal segment, kink resistant tapered tip of 0.016”, Tungsten braiding, +10 elliptical stainless steel braids for better support.
Dual lumen Microcatheter
Angled tip coronary microcatheter for side branch access. Should be FDA' or CE' and DCGI approved
Peripheral microcatheter with distal outer diameter of 2.4 F / 2.7 F and proximal outer diameter of 2.9 F
Peripheral Torqueable microcatheter with distal outer diameter of 2.4 F and proximal outer diameter of 2.7 F
Manual Thrombus Aspiration Catheter with stylet
Thrombus Extraction Catheters for PTCA with or without Stylet. Should be FDA' or CE' and DCGI approved
Foreign body retrieval micro snares (Coronary) Microsnare Kit
Foreign body retrieval snares
Foreign body retrieval snares
Biopsy forceps
HEMOSTASIS DEVICES
FEMORAL COMPRESSION DEVICES-DISC/DOME BASED COMPRESSION
FEMORAL COMPRESSION DEVICES- INFLATABLE BALLOON BASED COMPRESSION
RADIAL ARTERY COMPRESSOR – BALLOON BASED
RADIAL ARTERY COMPRESSOR - STRAP BASED
DRUG ELUTING CORONARY STENTS
BALLOON EXPANDABLE SIROLIMUS ELUTING SECOND /THIRD GENERATION CORONARY STENTS Diameter : 2.25 – 4.0 mm Length : 8 mm – 38 mm Rates to be quoted separately for: a) Cobalt chromium base- b) Platinum chromium base c) Stainless steel base- USFDA and CE (European)/ DCGI Certified/ Approved ) • All sizes and length in range mentioned should be available • USFDA and CE (European)/ DCGI Certified/Approved) • Coating of bioabsorbable polymer carrier with abluminal and gradient coating • The strut thickness should be 95 micron or less. • Optimized overexpansion capability up to additional 1.5mm of intended nominal size.
BALLOON EXPANDABLE EVEROLIMUS ELUTING SECOND /THIRD GENERATION CORONARY STENTS Diameter : 2.25 – 4.0 mm Length : 8 mm – 38 mm Rates to be quoted separately for: a) Cobalt chromium base- b) Platinum chromium base- • All sizes and length in range mentioned should be available • USFD and CE (European)/ DCGI Certified/Approved) • Dual-layer Balloon Technology • Low Profile 0.018” (0.45 mm) lesion entry profile Laser-Cut Hypotube Technology
BALLOON EXPANDABLE ZOTAROLIMUS COATED THIRD GENERATION DRUG ELUTING CORONARY STENT Diameter : 2.0 – 5.0 mm Length : 8 mm – 38 mm Rates to be quoted separately for: a) Cobalt chromium base- b) Platinum chromium base US All sizes and length in range mentioned should be available USFDA/ CE (European)/ DCGI Certified/Approved)
SIROLIMUS ELUTING BIOABSORBABLE ABLUMINAL POLYMER GRADIENT COATING FOR ACTIVE DRUG COATED COBALT CHROMIUM DES • Should be FDA' OR CE' AND DCGI approved • Diameter: 2.00 – 4.5 mm • Length :8 mm – 50 mm • All sizes and length in range mentioned should be available • The strut thickness should be 95 micron or less. • Stent design should be open cell type with two links • Optimized over expansion capability up to 6.25 mm for 3.5 mm to 4.5 mm stents
EVEROLIMUS ELUTING BIOABSORBABLE ABLUMINAL POLYMER COATED PLATINUM CHROMIUM • DES ,Should be FDA' OR CE' AND DCGI approved • Diameter : 2.25 – 5.0 mm • Length : 8 mm – 48 mm • All sizes and length in range mentioned should be available • ultra-thin < 75 µm struts • Dual-layer Balloon Technology • Fast absorption of biopolymer at less than 4 months
POLYMER AND CARRIER FREE DRUG COATED STENT (DCS) WITH BIOLIMUS A9 • Diameter : 2.0 – 4.5 mm • Length : 8 mm – 48 mm • All sizes and length in range mentioned should be available
ULTRA LOW PROFILE THIN STRUT 60 UM STENT • Should be FDA' OR CE' AND DCGI approved • Diameter : 2.0 – 4.5 mm • Length : 8 mm – 48 mm • All sizes and length in range mentioned should be available
DEB • Paclitaxel Drug Eluting • Transpax Coating • USFDA and DCGA approved DEB
DEB /DCB • Paclitaxel Drug Eluting • Rapid exchange Balloon catheter • with a non-compliant and semi compliant balloon • Balloon Diameters 2.50 mm – 4.50 mm • USFDA /CE/ DCGA approved DEB
Covered stent
COVERED STENT FOR CORONARY USE (BALLOON EXPANDABLE) • All common sizes (2.8 - 4.0 MM and 4.5 - 4.8) • Stainless steel
COVERED STENTS-CORONARY • Cobalt Chromium 5F -6F guiding compatible • Low profile all sizes. • Should be FDA'/CE'/DCGI approved
EMBOLIC PROTECTION SYSTEM • variety of sizes (3 – 7 mm) for optimal fit and apposition in a range of vessels 0.014” or 0.018” guidewire of choice • Highly flexible system is designed to provide excellent tracking through tortuous anatomy. • tapered nosecone to facilitate lesion crossing. • Retrieval sheath is designed to maximize filter coverage while withdrawing through deployed stent.
Peripheral items (Catheters)
ANGLED PIGTAIL CATHETER- FDA APPROVED • Sizes 6- 7 Fr • Must be FDA approved • Should be available in various lengths
PIGTAIL CATHETER WITH MULTIPLE MARKERS • Sizes 6- 7 Fr • Must be FDA approved • Should be available in various lengths • Should have multiple equidistant radio-opaque markers
COBRA CATHETER- FDA APPROVED • Sizes 5,6 Fr • Must be available in various standard curves and lengths C1,C2 ,C3 • Must be FDA approved
NIH CATHETER- FDA APPROVED • Sizes 6- 7 Fr • Must be available in various standard curves and lengths • Must be FDA approved
COURNARD CATHETER- FDA APPROVED • Sizes 6- 7 Fr • Must be available in various standard curves and lengths • Must be FDA approved
BRAIDED SIMMONS SHAPED CEREBRAL Catheter • 5/6 F, (Sim1, Sim2) • Should be FDA'/CE'/DCGI approved
RENAL DOUBLE CURVE GUIDE CATHETER • 4F-6F • 80CM, 120 CM, 140 CM. • Should be FDA'/CE'/DCGI approved
CATHETER HEAD HUNTER 4F, 5F AND 6F Should be FDA'/CE'/DCGI approved
Bernstein curve angiography catheter 4F, 5F AND 6F Should be FDA'/CE'/DCGI approved
SOFT TIPPED braided Guide catheters for (4F,5F,6F) for visceral use. Should be FDA' or CE' and DCGI approved
Peripheral wires
STEERABLE PTA GUIDE WIRE WITH FLOPPY TIP • scitanium stainless steel alloy core, • 0.014-0.018” diameter, 180-300 cm long. • Tip Non-hydrophilic or Tip Hydrophilic.
STEERABLE PTA WIRE • High support guide wire of 0.018”-0.035 “ • body PTFE/hydrophobic coated, distal hydrophilic coating, • distal radiopacity of 3 cm, 190- ≥300 cm long
PERIPHERAL GUIDE WIRES & SPECIALITY WIRES ( 0.018")
POLYMER COATED HYDROPHILIC WIRE 0.035 STRAIGHT AND J
Peripheral balloon
PERIPHERAL LONG BALLOON, SEMI COMPLIANT • Must be compatible with 4- 7 Fr sheath • various diameters of 2 mm to ≥8 mm. • Length: 20 to ≥200 mm. • OTW over 0.018” -0.035” guide wire.
PERIPHERAL BALLOON, SEMI COMPLIANT • Must be compatible with 5- 7 Fr sheath • various diameters of 4mm to 8mm. • Length: 20 to 40 mm. • Monorail, compatible over 0.18 – 0.035 inch wire guide wire.
PERIPHERAL BALLOON- BROAD PORTFOLIO WITH EACH SIZE RANGE ENGINEERED FOR SPECIFIC CLINICAL SITUATIONS • Balloon lengths from 20 mm to 250 mm • Balloon diameters from 3 mm to 14 mm • OTW over 0.035” guide wire • 5-7 F sheath compatibility
FOGARTY EMBOLECTOMY BALLOON 3F -7F SIZES • Must have a radiopaque straighter inside for positioning of the balloon
EMBOLIZATION COILS • Embolization coils of 0.014” diameter, different lengths • Embolization coils of 0.018” diameter, different lengths • Embolization coils of 0.021” diameter, different lengths • Embolization coils of 0.035” diameter, different lengths • Embolization coils of 0.038” diameter, different lengths • Sizes ranging from 2 x 2 to 15 x 15
MICROCOIL (0.018” DIAMETER) DELIVERY SYSTEM a) Coil delivery micro catheter b) Coil pusher c) all common sizes of coil
EMBOLISATION PARTICLES • Poly Vinyl Alcohol all sizes. • Should be FDA'/CE'/DCGI approved
LIPOIDOL FOR EMBOLIZATION SHOULD BE FDA'/CE'/DCGI APPROVED 10 Amp.
CYANOACRYLATE GLUE OR N-BUTYL CYANOACRYLATE GLUE • for sealing coronary perforation, AVM and varices • Should be FDA'/CE'/DCGI approved
Item peripheral stents (VASCULAR STENTS)
PTFE COVERED, PREMOUNTED BALLOON EXPANDABLE COVERED STENT • Covered self expanding covered stent grafts for Peripheral aneurysm and leaks (4mm to 12mm) • Should be FDA' or CE' and DCGI approved • Should be compatible with 6 – 7 Fr sheath • Should have low crossing profile
SELF EXPANDING VASCULAR STENTS FDA/CE/DCGA APPROVED • Approved for pediatric and adult use • Available in various lengths and diameters
BALLOON EXPANDABLE (PREMOUNTED) VASCULAR STENTS – FDA/CE/DCGA APPROVED • Approved for pediatric and adult use • Available in various lengths and diameters
SELF EXPANDING FEMORO POPLITEAL STENTS - ALL DIAMETERS. should be fda'/ce'/dcgi approved
CAROTID STENTS TAPERING SELF EXPANDING. should be fda'/ce'/dcgi approved
CAROTID STENTS STRAIGHT SELF EXPANDING. SHOULD BE FDA'/CE'/DCGI APPROVED
CAROTID DISTAL PROTECTION DEVICES. Should be FDA'/CE'/DCGI approved
CROSS OVER SHEATH (UP & OVER ) • CONTRALATERAL SHEATH 6F/7f. • Should be FDA'/CE'/DCGI approved
MULLINS SHEATH WITHOUT SIDE ARM OF 4- 9 Fr SIZES FOR USE IN VALVULAR INTERVENTION • Should have thick and stiff dilator for guiding septal puncture
MULLINS SHEATH WITH SIDE ARM – 4- 9 Fr • Dilator must be compatible with ≥0.035 inch guidewire • Sheath without dilator must have good radio opacity for better fluoroscopic visibility • Must be available in various standard lengths and curves
MULLINS SHEATH WITH SIDE ARM – 10- 12 Fr • Dilator must be compatible with ≥0.035 inch guidewire • Sheath without dilator must have good radio opacity for better fluoroscopic visibility • Must be available in various standard lengths and curves
MULLINS SHEATH WITH SIDE ARM – > 12 Fr size • Dilator must be compatible with ≥0.035 inch guidewire • Sheath without dilator must have good radio opacity for better fluoroscopic visibility • Must be available in various standard lengths and curves
SPECIAL LONG SHEATH WITH SIDE ARM – HAUSDORF CURVE • Dilator must be compatible with ≥0.035 inch guidewire • Sheath without dilator must have good radio opacity for better fluoroscopic visibility • Must be available in various standard lengths and curves
SPECIAL LONG SHEATHS WITH SIDE ARM – VARIOUS STANDARD CURVES OTHER THAN MULLINS CURVE • Must be available in various sizes and curves • Must be accompanied by separate dilators that are compatible with 0.018” wire, 0.025” wire or 0.035” wire
Device closure
ASD CLOSURE DEVICES WITH DELIVERY SYSTEM • All customised sizes and delivery cable from 8mm to 50 mm. • Should be FDA/CE' AND DCGI approved • Approved for pediatric and adult use • Device must be made up of biologically inert material • Self-centering, detachable device with delivery cable • Available in all approved sizes • Must quote the price of individual components of delivery system (delivery sheath and cable) separately • For comparative analysis the price of whole unit will be taken into consideration
FENESTRATED ASD DEVICE FOR MUTIPLE SEPTAL DEFECTS WITH CABLE AND ACCESSORIES • narrow waist, which allows for placement through a central defect, and matched disc diameters that maximize coverage of multiple fenestrations. • Should be FDA'/CE'/DCGI approved • Approved for pediatric and adult use • Device must be made up of biologically inert material • Self-centering, detachable device with delivery cable • Available in all approved sizes • Must quote the price of individual components of delivery system (delivery sheath and cable) separately • For comparative analysis the price of whole unit will be taken into consideration
VSD CLOSURE DEVICES WITH DELIVERY SYSTEM - FDA APPROVED • Ventricular septal defect Closure Devices All sizes ( 4mm to18mm).Should be FDA'/CE'/DCGI approved • Delivery cable Ventricular septal defect closure For Ventricular septal defect Closure Devices All sizes ( 4mm to18 mm). Should be FDA'/CE'/DCGI approved" • Approved for pediatric and adult use • Device must be made up of biologically inert material • Self-centering, detachable device with delivery cable • Available in all approved sizes • Must quote the price of individual components of delivery system (delivery sheath and cable) separately • For comparative analysis the price of whole unit will be taken into consideration
POST INFARCT VENTRICULAR SEPTAL RUPTURE CLOSURE DEVICES- All sizes and types. FDA approved
PDA CLOSURE DEVICES WITH DELIVERY SYSTEM • PDA occlusion device --all customizable sizes from 3mm to 20mm waist size. • Should be FDA'/CE'/DCGI approved • Delivery Cable for PDA Occlusion Device • Approved for pediatric and adult use • Device must be made up of biologically inert material • Self-centering, detachable device with delivery cable • Available in all approved sizes • Must quote the price of individual components of delivery system (delivery sheath and cable) separately • For comparative analysis the price of whole unit will be taken into consideration
PDA CLOSURE DEVICES WITH DISC ON BOTH SIDES WITH DELIVERY SYSTEM - FDA APPROVED • Approved for pediatric and adult use • Device must be made up of biologically inert material • Self-centering, detachable device with delivery cable • Available in all approved sizes • Must quote the price of individual components of delivery system (delivery sheath and cable) separately • For comparative analysis the price of whole unit will be taken into consideration
VASCULAR PLUGS (THE DEVICE IS SHIPPED ATTACHED TO A 135CM NITINOL DELIVERY WIRE IN A HOOP DISPENSER) • Self-expanding device 3 lobed multilayer Nitinol mesh • The device is shipped attached to a 135cm nitinol delivery wire in a hoop dispenser • The device is preloaded in a loader • Approved for pediatric and adult use • Device must be made up of biologically inert material • Self-centering, detachable device with delivery cable • Available in all approved shapes and sizes
VASCULAR PLUGS 155 CM LONG PTFE-COATED DELIVERY WIRE • Self expanding Nitinol mesh occlusion device • PTFE-coated Stainless wire coil with NiTi core • 155 cm long PTFE-coated delivery wire • compatible with 0.038" guide wire compatible diagnostic catheters • Approved for pediatric and adult use • Self-centering, detachable device with delivery cable • Available in all approved shapes and sizes
PTMC BALLOON • ALL SIZES OF PTMC Balloons • Accessories for PTMC Balloons. • Accessories include a) Coiled LA guide wire for tracking the balloon into LA b) 21F black dilator c) LV entry wire d) metal stretching tube e) stylet f) syringe for inflation g) ruler/caliper for measuring balloon size • Should be FDA CE' AND DCGI approved
PEDIATRIC VALVULOPLASTY TYSHAK-II BALLOONS • Bifoil balloons with accessories all sizes. • Should be FDA'/CE'/DCGI approved
Miscellaneous
BIPOLAR TEMPORARY PACING CATHETERS VENTRICULAR PACING WITH RIGHT HEART CURVE 5F -6F, LENGTH -110CM • Designed to provide pacing and sensing in the ventricle from the inferior vena cava approach • Designed to balance maneuverability and mechanical stability • Solid core enables user to customize the curve • 10 cm depth markers to enhance placement • Smooth, hemocompatible polyurethane coating • Stainless steel center conductor and electrodes • Clearly marked terminals • Unshrouded/exposed pin connector leads
FEMORAL PERCUTANEOUS CLOSURE DEVICE (COLLAGEN MEDIATED CLOSURE) • Active closure device with collagen, anchor and suture based • collagen, anchor and shutter should completely absorbed in 3 months • To ensure exact deployment/anchor site, Packet should contain dedicated insertion sheath with depth markers, compatible dilator /arteriotomy locator and compatible mini Guidewire
FEMORAL PERCUTANEOUS CLOSURE DEVICE (SUTURE MEDIATED CLOSURE)
RENAL ARTERY DENERVATION CATHETER SYSTEM FOR MANAGEMENT OF RESISTANT HYPERTENSION. Should be FDA/CE/DGCI approved. CONSOLE provided by the company on demand
PHARMACO-MECHANICAL (THROMBUS EXTRACTION CATHETERS FOR PERIPHERAL VENOUS /PULMONARY THROMBI 6F - 8F WITH A SUCTION DEVICE PROVIDED BY THE COMPANY ON DEMAND . Should be FDA'/CE'/DCGI approved
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
TD.pdf
Tender Documents • 1.56 MB
BOQ_22807.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .