Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.4 LAccepted-Finance NO 03 PERUMAL KOVIL STREET MINJUR 601203 | THIRUVALLUR | TAMIL NADU | 601203 | L1 | Accepted-Finance accepted | |
| 2 | L2₹59.1 L+₹2.7 L (4.85%)Accepted-Finance | L2 | Accepted-Finance accepted | |
| 3 | Rejected-Technical 21 CHAKRADHAR SOCIETY OLD SAIKHEDA ROAD NEAR MARUTI WAFERS NASHIK DWARKA MAHARASHTRA NASHIK MAHARASHTRA 422011 | NASHIK | MAHARASHTRA | 422011 | - | Rejected-Technical EMD and all BQR condition not satisfied |
| Sl No | Description | Qty | Unit | M.ANBAZHAGAN L1 | S.MATHURAM CONTRACTOR L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for Calibration of pressure gauges, temperature gauges, differential pressure gauges and vaccum gauge. | 1,200 | Nos. | 407.65 ₹5,77,232.4 Lowest | 425 ₹6,01,800 |
| 2.00 | Charges for Calibration of pressure transmitter, Differential pressure transmitter and temperature transmitters, temperature scanners, Flow transmitters, Level transmitters and Digital Indicators . | 660 | Nos. | 543.52 ₹4,23,293.38 Lowest | 568 ₹4,42,358.4 |
| 3.00 | Charges for Calibration of RTD, TC, I/P Converter and Solenoid valves, Pressure switches and temperature switches and vaccum switches. | 750 | Nos. | 545.5 ₹4,82,767.5 Lowest | 570 ₹5,04,450 |
| 4.00 | Charges for dismantling and refixing of temperature gauges, pressure gauges, differential pressure gauges,Vaccum gauges,process parameter switches, RTD, Thermo couples, process transmitters covered in Instrumentation system of 210MW Generators of units I,II&III, Instrument air compressor,SWBP, ACW,Dosing system and condensers, peripherals plants namely Hydrogen plant, CWPH, AC plant, Recovery pump house, AHP of units I, II & III, DM plant & RO plant, flue gas analysers of units I, II & III. | 1,000 | Nos. | 408.65 ₹4,82,207 Lowest | 430 ₹5,07,400 |
| 5.00 | Charges for checking and correcting annunciation signal in annunciation system of 210MW generators of units I, II, III and peripherals plants namely AHP, CWPH, AC plant, Hydrogen plant, Chlorination plant, DM plant and RO plant. | 800 | Nos. | 410.6 ₹3,87,606.4 Lowest | 450 ₹4,24,800 |
| 6.00 | Charges for Removal,cleaning, refixing and checking of Sensors and electronic units of water analysers available in peripheral plants namely AHP, Chlorination plant , Hydrogen plant, raw water pump house, RO plant & DM plant, Generator instrumentation system and flue gas analysers of units I, II & III . | 1,120 | Nos. | 1,630.6 ₹21,55,000.96 Lowest | 1,702 ₹22,49,363.2 |
| 7.00 | Charges for taking routine and trial run vibration readings for HT rotating machines like Turbine & Generator, BFB, CEP, Coal Mill, Conveyor motors, Cooling Water Pump etc. of units I,II & III.. | 1,140 | Nos. | 410.6 ₹5,52,339.12 Lowest | 430 ₹5,78,436 |
| 8.00 | Charges for SS/MS Welding joint for Sample line in Stator water System of units I, II & III and ACW line of sample cooler in Steam Water Analysis System of units I, II & III raw water pump house, RO plant & DM plant and protection probe and flanges of flue gas analysers of units I, II & III. | 210 | joints | 2,341 ₹5,80,099.8 Lowest | 2,444 ₹6,05,623.2 |
Tender Value
Refer Docs
EMD Value
₹46,500
Closing Date
16 Sept 2026, 2:00 pmClosed
SE/ES/NCTPS-I
SE/ES/NCTPS-I,chennai-120
NCTPS I ES Circle C I Dn Sub division VI Carrying out maintenance activities of C I equipments in LAB PERIPHERALS GENERATOR sections and calibration of field instruments for a period of 360 days for the year 2026 27
2026_EB_700178_1
CE/NCTPS-I/SE/ES/WC-57/2026-27
Open Tender
Power/Energy Projects/Products
Works
360 days
NCTPS-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹46,500
Yes
28 Sept 2026
1 Sept 2026
17 Sept 2026
1 Sept 2026
16 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Charges for Calibration of pressure gauges, temperature gauges, differential pressure gauges and vaccum gauge. | 1,200 | Nos. | 354.48 | ₹4,25,376 |
| 2 | Charges for Calibration of pressure transmitter, Differential pressure transmitter and temperature transmitters, temperature scanners, Flow transmitters, Level transmitters and Digital Indicators . | 660 | Nos. | 472.63 | ₹3,11,935.8 |
| 3 | Charges for Calibration of RTD, TC, I/P Converter and Solenoid valves, Pressure switches and temperature switches and vaccum switches. | 750 | Nos. | 472.63 | ₹3,54,472.5 |
| 4 | Charges for dismantling and refixing of temperature gauges, pressure gauges, differential pressure gauges,Vaccum gauges,process parameter switches, RTD, Thermo couples, process transmitters covered in Instrumentation system of 210MW Generators of units I,II&III, Instrument air compressor,SWBP, ACW,Dosing system and condensers, peripherals plants namely Hydrogen plant, CWPH, AC plant, Recovery pump house, AHP of units I, II & III, DM plant & RO plant, flue gas analysers of units I, II & III. | 1,000 | Nos. | 354.48 | ₹3,54,480 |
| 5 | Charges for checking and correcting annunciation signal in annunciation system of 210MW generators of units I, II, III and peripherals plants namely AHP, CWPH, AC plant, Hydrogen plant, Chlorination plant, DM plant and RO plant. | 800 | Nos. | 354.48 | ₹2,83,584 |
| 6 | Charges for Removal,cleaning, refixing and checking of Sensors and electronic units of water analysers available in peripheral plants namely AHP, Chlorination plant , Hydrogen plant, raw water pump house, RO plant & DM plant, Generator instrumentation system and flue gas analysers of units I, II & III . | 1,120 | Nos. | 1,417.9 | ₹15,88,048 |
| 7 | Charges for taking routine and trial run vibration readings for HT rotating machines like Turbine & Generator, BFB, CEP, Coal Mill, Conveyor motors, Cooling Water Pump etc. of units I,II & III.. | 1,140 | Nos. | 354.48 | ₹4,04,107.2 |
| 8 | Charges for SS/MS Welding joint for Sample line in Stator water System of units I, II & III and ACW line of sample cooler in Steam Water Analysis System of units I, II & III raw water pump house, RO plant & DM plant and protection probe and flanges of flue gas analysers of units I, II & III. | 210 | joints | 2,036.1 | ₹4,27,581 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_841623.xls
BOQ • 0.34 MB
corrigendum.pdf
PDF • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .