Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹44.0 LAccepted-AOC | 1 | Accepted-AOC Being lowest | |
| 2 | 2₹51.2 L+₹6.3 L (14.1%)Rejected-Finance 147 WEST ARJUN NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 2 | Rejected-Finance Not being lowest | |
| 3 | 3₹52.3 L+₹7.4 L (16.5%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | 3 | Rejected-Finance Not being lowest | |
| 4 | 4₹55.5 L+₹10.6 L (23.7%)Rejected-Finance 91 DEFENCE ESTATE PHASE II NEAR AMBEDKAR PARK DEORI ROAD AGRA UP | AGRA | UTTAR PRADESH | 282001 | 4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical 205L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | - | Rejected-Technical Being two class below for eligible class |
Tender Value
₹51.5 L
EMD Value
₹1.0 L
Closing Date
28 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE AGRA
112 TAJ ROAD, AGRA CANTT
SPL REPAIR TO BLDG NO.363/1, 2 AND 3 AT AATS UNDER GE (EAST) AGRA
2022_MES_499593_2
84234/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA
MES contractors enlisted in Class C category a(i)for unenlisted contractors meeting the enlistment criteria corresponding to value class and category of work
8 documents required · 8 mandatory
₹1,000
GE EAST AGRA
₹1.0 L
Yes
3 Jun 2022
7 Apr 2022
4 May 2022
7 Apr 2022
28 Apr 2022
14 Apr 2022
7 Apr 2022 - 11 Apr 2022
60 days
Amount
Taking down cement or cement lime plaster of any description including racking out joints, hacking for keys ,scrubbing down with water etc complete all as specified and directed.
Demolition of brick or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone works and precast concrete articles, complete all as specified and directed
M&L Brick work with sub class B bricks, old size, straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
M&L Rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete surfaces and finishing the surfaces fair and even complete all as specified and directed.
M&L Rendering 15 mm thick in CM (1:4) on stone masonry surfaces or surface other than fair faces of brick work or concrete surfaces and finishing the surfaces fair and even with using water proofing compound as per manufacturer's instructions complete all as specified and directed. Note:- Water proofing compound shall be measured and paid for seperately under respective item of Schedule 'A'.
M&L preparation of new plaster surfaces on walls and applying two coat of distemper oil emulsion over a coat of white cement priming paint. complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement primer on walls. complete all as specified and directed.
M&L preparation of old plastered plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing old decorated surfaces of walls plastered or un-plastered by complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc for smooth finishing and applying two coats of oil emulsion distemper over a coat of chalk whitening complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall and applying three coat of white wash Complete all as Specified and directed
S&F in repair 15 mm bore galvanized steel tubes, medium grade for flush pipes, water supply pipes etc, fixed to walls and ceiling or laid in floor complete all as specified and directed.
S&F in repair 20 mm bore galvanized steel tubes, medium grade for flush pipes, water supply pipes etc fixed to walls and ceilings or laid in floors etc complete all as specified and directed.
S&F in repair 15 mm bore fency type illar taps, cast copper alloy, with capstan heads chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long secrwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.
S&F in repairs stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repairs PVC body valveless,syphonic action type, flushing cistern 10 ltr capacity, low level, white, with inlet ball valve and float,and handle including bracket and PVC flush pipe 32 mm dia complete all as specified and directed Cat Part No: .E-8297 of make Parry ware Slimline or equivalent model in specified makes as approved by GE.
S&F in repair PVC (SWR) floor trap with grating of 75 mm dia outlet including jointing with solvent cement complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
M&L for non skid coloured Ceramic jointless tiles,first quality( of approved class , colour and design/ shade ) 7 to 8 mm thick (Square/ rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.18 sqm, ,as in floor surface etc set and jointed in neat cement slurry and pointed in coloured cement to match with shade of coloured tiles over and including 15 mm thick Screed bed in Cement mortar 1: 6 Complete all as specified and directed.
M&L for glazed coloured ceramic tiles ,first quality ( of approved class , colour and design/ shade ) of size 350 x 250 x 7mm / 450 x 350 x 7mm thick in vertical surfaces, as in dado / skirting etc set & jointed in neat cement slurry & pointed in coloured cement to match with shade of coloured tiles, over and including 10 mm thick rendering in cement mortar (1:4), rough finish to receive the tiles complete all as specified and directed.
M&L for Ceramic mat finish jointless coloured tiles of 7 to 8 mm thick (Square/ rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.36 sqm, ,as in each floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with shade of coloured tiles over and including 15 mm thick Screed bed in Cement mortar 1: 6 Complete all as specified and directed.
M&L for vitrified ceramic (light shade) tiles 10 mm thick (square rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match screed bed or bedding layer of mortar 15 mm in CM 1:4 thick for laying floor finishes complete all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and includingscreed like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description as in ground floors and pavings not exceeding 15 cm thickness (above or below ground level ) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismicand other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
M&L for 75 mm thick PCC (Cement concrete) 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection finished even and fair and making 50mm deep joints at every 3 metre interval and at every corner and filling the joints with bitumen of grade 85/25 and sand mixture 1:3 complete all as specified and directed
Supply only integral water proofing compound ISI marked complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) area n. exc. 1.50 sqm each complete all as specified and directed.
Taking down Chowkhats or frames with shutter (without taking off shutters from the frame) exc. 1.50 sqm and n.exc. 4 sqm each complete all as specified and directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube as per specification & drawings specified in SSR Part-II 2010 complete all as specified and directed.
S&F Factory made solid PVC door shutter 30mm thick (style) consisting of solid panel wood grain printed PVC sheet & 5 mm thick x 15 mm wide PVC sheet beading inside stiles and rails and decorative PVC beading of 10 mm x 10 mm (90) frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded decorative colour PVC 'C' chaneel having a PVC sheet strip of 20 width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site as per specification etc complete all as specified and directed
S&F framed work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming Fe-410 Gde E-250 fixed complete all as specified and directed.
S&F 32 mm thick factory made flush shutters solid core construction with block board core and plywood face panels, commerical type on both side complete all as specified and directed.
S&F 30 mm thick 2nd class (Hollock / Benteak) kiln seasoned and chemically pressure treated glazed & skelton shutters, open rebated and prepared to receive glass / gauze (without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters etc complete all as specified and directed.
S&F steel windows with side hung shutters incl box type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F steel windows with side hung shutters incl box type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framed work and similar works conforming to Fe-290 Gd E-165 complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples etc complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples etc complete all as specified and directed.
S&F Steel ventilator with top hung shutter including projecting type hinges, steel peg stay, with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F for 4 mm thick figured glass pin headed type in square n. exc. 0.5 sqm each pane and glazing with oil putty in squares not exc. 0.5 sqm in each pane complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 200 mm long and fixed complete all as specified and directed.
S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed all as specified and directed.
S&F 100 mm size butt hinges, medium weight, cold rolled and fixed with screws/welded to frame complete all as specified and directed.
S&F 100 mm size butt hinges cast type brass with mild steel hinge pin bright polished and fixed etc complete all as specified and directed.
S&F 150 mm long extruded handles, fabricated type, aluminium anodized complete all as specified and directed.
S&F floor door stopper of 140 mm aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor including cover plate and rubber piece complete all as specified and directed.
M&L for plain cement concrete 1:2:4 mix type B-1 (using 12.5 mm graded stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work etc complete all as specified and directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified and directed.
M/S for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and apply two coat of synthetic enamel paint (ordinary tint) over a coat of red oxide primer etc complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinry tint) etc complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinry tint) etc complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / blankets, any thickness, including cover fillets complete all as specified and directed etc complete all as specified and directed.
Dismantling asbestos cement (corrugated semi corrugated etc) sheet in roof covering complete all as specified and directed.
Dismantling framed work as in fillets, rails, posts, raffers, purlin etc and 40 sqcm under in section complete all as specified and directed.
S&F prepainted galvolume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall ridges fixed with self tapping screws complete all as specified and directed.
S&F anodized aluminium snap grid frame work 605 x 605 mm in size for flase ceiling complete all as specified and directed.
S&F 4 mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / Aluminium frame work with screws complete all as specified and directed.
S&F in repair one piece Europen type water closet (snow white) with seat cover and twin flush fittings including necessary traps and connection to drain and flushing pipe etc of size 710 x 390 x 790 mm etc complete all as specified and directed.
S&F in repair one piece wash basin with integrated half pedestal complete fixed to wall with rag bolts as per manufacturers instructions of size 480 x 425 x 365 mm etc complete all as specified and directed.
S&F in repair polyamide braided connection pipe 450 mm length (2 piece set) etc complete all as specified and directed.
S&F in repair waste coupling with ceramic pop up push type (full thread) 32 mm with necessary waste pipe 32 mm fixed to drain etc complete all as specified and directed.
S&F in repair SS towel rail ends pair with 60 cm stainless steel rod of etc complete all as specified and directed.
S&F in repair soap of n.exc. 150 mm dia or width tray of any size and any dia etc complete all as specified and directed.
S&F in repair CP wall mixer with 210 mm long bend pipe for over head shower of model green complete all as specified and directed.
S&F in repair CP single lever basin mixer 15 mm with 450 mm braided connection pipe without op up of model green etc complete all as specified and directed.
S&F in repair bib cock with flange , fancy type, brass,chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in repair fancy type angle cock with flange, 15 mm nominal bore, brass, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and directed.
S&F in repair overhead shower arm 305 mm with wall flange (stainless steel) etc complete all as specified and directed.
S&F in repair health faucet ABS body with wall hook and 1 mtr SS braided rubber hose pipe etc complete all as specified and directed.
S&F in repair paper holder with flap guard (SS) etc complete all as specified and directed.
S&F in repair corner glass shelf (large) 300 x 300 mm with SS bracket etc complete all as specified and directed.
S&F in mirror 700 x 500 mm 5 mm thick glass mirror with double cost for protection and longevity grounded edges for safety and silver plating on the back for better reflection fixed to wall etc complete all as specified and directed.
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and including taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
Material and labour for point wiring with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed PVC conduit (Medium grade) of suitable size all as directed with using new sunken type pressed steel box / terminal boxes for mounting fittings/junction boxes not less than 1.6mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with 3mm thick bakelite laminated sheet, and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
All as per Srl item No 76 here in above but point wiring for for one light point or one fan point controlled by one switch complete all as specified and directed.
All as per Srl item No 76 here in above but point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board complete all as specified and directed.
All as per Srl item No 76 here in above but point wiring for 5 pin switch socket outlet, 5 Amps on same board with other switches complete all as specified and directed.
All as per Srl item No 76 here in above but one bell / buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
All as per Srl item No 76 here in above but point wiring for one six pin socket outlet, 15 & 5 Amps (independent) controlled by one switch with using 2.5 Sqmm (nominal area) stranded copper conductor omplete all as specified and directed. Notes for item 76 to item 81 here in before :- (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs and provision of covering sunken boards/terminal boxes / junction boxes of any shape and size with 3mm thick bakelitelaminated sheet fixed with suitable GI screws and cup washers) (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A' (iii) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade)
All as per item No.76 here in before but with cable size 4 sqmm for one AC socket outlet on independent board and multistrand insulated copper earth continuity conductor of size 4 Sqmm complete all as specified and directed.
Supplying & fixing modular switch, single pole one way 6 Amps, 01 module 230 volts AC circuit complete all as specified & directed.
Supplying & fixing modular switch,one module single pole one way 01 module 16 Amps, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing modular socket outlet, double module 6 Amps, combined 2 moduel 2/3 pin, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing modular socket multipurpose,double module 6-16 Amps, combined 2 module 3 pin, 230 volts AC circuit complete all as specified & directed.
Supplying & fixing modular ceiling fan regulator, electronic, step type double module, suitable for ceiling fans of any capacity, pre-wired 240 volts AC 50Hz supply 120 Watt complete all as specified & directed.
Supplying & fixing modular Bell push 6A one module, single pole, one way complete all as specified and directed.
Disconnecting and taking down old unserviceable sheet metal enclosure any size any type including MCB etc complete and supply, fixing, connecting & testing sheet metal single pole and neutral enclosure with metal clad (two pin and earth) plug top and socket complete with and incuding one No MCB ('C' series), SP, 20 Amps, 240 volts having breaking capacity 10 KA complete all as specified and directed.
Supply and fixing in repair call bell, ding dong type, 230 volt AC single pole complete all as specified and directed.
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 63.5 x 20 mm, three terminals, complete all as specified & directed.
Supplying & fixing modular cover plate with metal frame (inner and outer) 1 Module for mounting switch and sockets complete all as specified & directed
Supplying & fixing modular cover plate with metal frame (inner and outer) 2 Module for mounting switch and sockets complete all as specified & directed
Supplying & fixing modular cover plate with metal frame (inner and outer) 3 Module for mounting switch and sockets complete all as specified & directed
Supplying & fixing modular cover plate with metal frame (inner and outer) 6 Module for mounting switch and sockets complete all as specified & directed
Supplying & fixing modular cover plate with metal frame (inner and outer) 8 Module for mounting switch and sockets complete all as specified & directed
Supplying & fixing blank spacer plate for single module complete all as specified and directed.
Supplying & fixing in repair metal flush sunken box 1/2 module for mounting of module cover plate with metal frame complete all as specified and directed.
S&F in replacement LED battan surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 20W, luminaire lumens > 2000 lms, system efficiency of > 120 lumens / W, LED of make : Nichia / Cree / Everlite / Eclison / OSRAM / Lumiled, with LED binding as per ANSJ Bin C78377A, Ingress protection IP 20, colour rendering index CRI > 80, temp range 0 to 45 ºC, driver efficiency > 85%, power facor > 0.95 THD < 20% as per IEC 61000-3-2, colour temp - 6500 K Surge protection 2.5 KV, 50000 burning hrs (min) as per L 70 criteria, two stages isolated constant current operated driver with range 150 - 270 VAC and safety extra low voltage safe level < 60 VDC as per IEC standard with LM 70 & 80 certification complete all as specified& directed. Make :- Wipro Model No.LL20-221-XXX-65NE3 or equivalent model of make CG/ Phillips as approved by GE.
Supplying, fixing in replacement & testing surface/ wall mounted LED batten, with specially designed powder coated aluminium housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption < 10 W, luminarie lumen > 1000 lms, system efficiency > 120 lms /w, CRI > 80, LED Make : Nichia /Cree/Everlite / Eclison / Osram/Lumiled with LED binning as per ANSJ Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class 1, colour temp -5700K, Ingress protection IP 20, driver efficiency> 85%, 50000 burning hours (min) as per L70 criteria, ambient, temp 0 to 500C, power factor > 0.95, THD < 10%, surge protection is CM-2.5KV, two stages isolated constant current operated driver with range 150-170V AC and safety extra lowe voltage safe level < 60V DC as per IEC standard, with LM70 & LM80 certification and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.50 Sqmm and fixing arrangements for fixing the light fitting complete all as specified & directed. Make :- Wipro Model No.LL20-221-XXX-65NE3 or equivalent model of make CG/ Phillips as approved by GE.
Supplying & fixing for lamp holder insulated body with back plate suitable for batten fitting complete all as specified and directed.
Supply & fixing LED bulb 7 W, warm white suitable for lamp holder complete all as specified and directed. Cat part No.LHLDEUHEML8R009 of Make Havells or equivalent in Philips / Wipro / CG as approved by GE.
Supply & fix in repair surface mounting type bulk head 10 watt LED luminaire with reflector cover electronic, driver, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified and directed. Cat part No.FT10WLED857SSYMBOPC of make Havells or equivalent model of make Philips / Bajaj / Crompton Greaves / Wipro Cat LW07-141-xxx-57-G1 and Syska Cat part SSK-BHP-1201- 12W as approved by GE.
S&F in replacement LED security with aluminium pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-65 protection, power consumption <35 W and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia / Cree / Osram, CRI > 70, ambient temperature range 0-450c, THD < 10% colour temperature 5700 K, surge protection cm 3.5 KV 50000 burning hour as per L70 criteria, multi stage constant current constant voltage operated driver with range 150-270 V AC and safety extra low voltage safe level <60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall complete all as specified and directed. Wipro Cat part No.LR02-331-XXX-57-XX or equivalent of Philips / Bajaj.
Disconnecting & taking up or down existing unserviceable sub main wiring of copper/aluminium conductor with two run of single core cable with one run of single core earth conductor cable of any description, any size & in any position without taking out existing conduits of any description and M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 20 mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 6 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. Notes :- (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs)
M&L for sub main with two runs of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20 mm dia with its accessories, concealed type, including one run of sinzle core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete al las specified and directed. Note :- Finished submain wiring with two runs of 4.0 sqmm cable & one run 4.0 sqmm cable along with PVC conduit including its accessories shall be measured and paid one unit length.
Disconnecting and taking down old unserviceable distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces to the existing surfaces complete all as specified and directed.
Supply, fixing, connecting & testing factory made, epoxy powder coated, distribution board (sheet metal encloser) , triple pole and neutral, 4 ways, (Vertical DB's) ,fixed flush to wall and suitable for universal mounting with having copper bus bars of capacity 250 Amps rating, of suitable size , and provisions for MCCB as incomer and MCBs SP as out going , conforming to IS : 13032 with and including one MCCB 63 Amps, 3 pole, 415 volts, AC supply having ultimate breaking capacity Icu 16 KA and Ics= 100% of Icu with adjustable 70% to 100% and thermal magnetic release ( the same make of DBs) complete all as specified & directed.
Supply and fix in repair MCCB 4 pole 100 to 125 Amp Icu 16 Kilo Amp and Ics 100% of Icu with adjustable 70% to 100% and thermal magnetic release complete all as specified and directed.
Supply, fixing, connecting & testing factory made, epoxy powder coated, distribution board (sheet metal encloser) , singe pole and neutral, 8 ways, (Horizontal DB's) ,with metal door and fixed flush to wall and suitable for universal mounting with having copper bus bars of capacity 200 Amps rating, of suitable size , for double door and suitable for using MCB, SPN as incomer and MCBs SP as out going, conforming to IS : 13032 complete all as specified & directed, ( Note: MCBs shall be measured and paid for separately under appropriate item of Sch ‘A’.
Supplying & fixing in repair MCB SP, 1 to 32 Amps (`C’ curve) having short circuit rating 10 KA, 240 volt complete with connection testing and commissioning complete all as specified and directed.
Supplying & fixing in repair MCB SPN, 40 to 63 Amps (`C’ curve) having short circuit rating 10 KA, 240 volt complete with connection testing and commissioning complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and fixing as in replacementment of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixedto poles or any other indicated situation for loop earthing etc as required of size 25 x 4 mm galvanized iron or steel strip complete all as specified and directed.
Supply and fix in repair exhaust fan made by sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm including make in good to the disturbed surface MS bolts, grouted to wall and connecting up including provision in cable from connector to fan with flexible cable 24/0.2 mm with copper conductor and necessary fitting arrangements complete all as specified and directed. (Note :- Retrieved fan shall be deposited to E/M store yard).
Supply & fixing in repair, connecting & testing exhaust fan heavy duty, CI body single phase 230 V, of size 300 mm sweep 1400 rpm with louvered shutters including necessary fixing arrangements on wall with & including bracket nut and bolts and including connecting wire with new 3 core 0.50 Sqmm PVC insulated and sheathed copper conductor cable from ceiling rose and also writing MES No. with black paint complete all as specified and directed. (Note :- Retrieved fan shall be deposited to E/M store yard).
Supply & fixing in repair, connecting & testing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor (BLDC) and including connecting wire with new 3 core 0.50 Sqmm PVC insulated and sheathed copper conductor cable from ceiling rose and also writing MES No. with black paint complete all as specified and directed. (Note :- Retrieved fan shall be deposited to E/M store yard).
Supply and fix in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc also writing MES No. with black paint complete all as specified and directed. (Note :- Retrieved fan shall be deposited to E/M store yard).
Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 along with parallel home display spilt unit and inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday defintion, complete all as specified and directed.
Supply, laying, jointing & testing in repair of XLPE insulated PVC sheathed (heavy duty) armoured cable with aluminium conductor for working voltage upto 1100 volts size 25 sqmm 3.5 core conforming to IS 7098 Part-I or IS 1554 Part-I complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing of cable, protection covers/ bricks complete all as specified and directed Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and protection cover/Bricks . (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
Returning, filling in excavated soil including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed .
Removal of surplus excavated soils to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for sand filling with clean dry find sand unwashed including gently punning around under ground cables in trenches / ducts for cable protection with layers of sand (8 cm deep before laying cable and 15 cm after laying cable) complete all as specified and directed.
M&L for old size sub class 'B' brick, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed.
Supplying and fixing GI tubing, 40 mm bore, light grade as in sleeving / protection of cable etc laid in trenches / floor or fixed on pole / wall etc with and including suitable size of MS clamp and nut, bolt, washer etc complete all as specified and directed.
HARI BUILDERS
Attar Singh and Sons
Gupta Automobiles
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .