Loading…
Loading…
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
18 Sept 2026, 6:00 pm
GE (West) Delhi Cantt-10
GE (West) Delhi Cantt-10
Day to day maint of internal electrification,submain wiring,DBs, old fitting LED in MD Accn area of Shekhawati Line, Hazipeer Line, Old NPG Line under GE (West), Delhi Cantt-10
2026_MES_786550_1
GE/DW/TOKEN/90 OF 26-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
delhi
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Delhi Cantt
₹50,000
Yes
27 Aug 2026
27 Aug 2026
21 Sept 2026
27 Aug 2026
18 Sept 2026
12 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets,regulators light fittings) and removal from site and making good the disturbed surfaces of (wall/floors/ceiling etc) complete all as specfied & directed. | 510 | Per point | - | - |
| 2M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 1.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed at site for the following: Note :- Point wiring drawn in existing conduit/new conduit, as per site requirement all as specified and directed,No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. | |||||
| 2.01 | One light/fan/bell/Exhaust fan/Fresh Air Fan point controlled by one way switch 5 amps. complete all as specfied & directed. | 300 | Per point | - | - |
| 2.02 | One 3 pin 6 Amps socket outlet point controlled by one way switch on independent board. complete all as specfied & directed. | 90 | Per point | - | - |
| 2.03 | One 3 pin 6 Amps socket outlet point controlled by one way switch on same board along with other switches. complete all as specfied & directed. | 50 | Per point | - | - |
| 2.04 | One light point controlled by two, two way switch. complete all as specfied & directed. | 10 | Per point | - | - |
| 3 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 2.5 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), with modular metal flush boxes of size 1.6 mm thick including cover plate with frame of white colour of suitable size as required at site, including PVC insulated multi stranded copper conductor 2.5 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed.
Note :- Point wiring drawn in existing conduit/new conduit, as per site requirement all as specified and directed,No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring . | 45 | Per point | - | - |
| 4 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi stranded copper conductor 4.0 sqmm nominal cross sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade, ISI-694 marked with valid CML No in and including medium grade, PVC concealed conduit of dia not less than 20 mm and conduit accessories concealed in wall (Brick/stone masonary), ISI marked with valid CML No (IS-9537-1983 for conduits and IS: 3419:1976 for conduit accessories), including PVC insulated multi stranded copper conductor 4.0 sqmm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth duly complete including replastering and making good the surface of wall and painting with existing colour all as specified and directed.(For AC point)
Note :- Point wiring drawn in existing conduit/new conduit, as per site requirement all as specified and directed,No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring . | 15 | Per point | - | - |
| 5 | Identifying and rectifying the defects pertains to ceiling fans/exhaust fans/fresh air fans and connects electric circuit, tightening of loose wiring/conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments,screwing/tightening the nuts/bolts/washers etc incl taking down & refixing properly in the same position after repairs, complete all as specified and directed.
Note:-
(a) Supply of Self Adhesive PVC Electrical Insulation tape of size 6.5mX1.80 cm X0.125 mm, mix colour box in a packet of 12 roll as per site requirement. (b) Supply of brass screw1/2 inch to 1.5 inch in packet of 50 pcs as per site requirement. (c) Supply of Wall Rawl Plugs/Gitti in packets of 100 pcs as per sample and as per site requirement. | 380 | Each Job | - | - |
| 6 | M&L for rewinding of ceiling fans of any type and make with super enamelled copper wire of appropriate gauge suiatble for existing make in the workshop including necessary lathe work on shaft, both sides of rewinding covered with high quality varnish and provisions of new nuts/pins including taking out old burnt wind of copper/aluminium complete all as specified and directed. | 260 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
PS90.pdf
Tender Documents • 0.74 MB
BOQ_881434.xls
BOQ • 1.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].