Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L1 | Accepted-AOC Being Rate Reasonble | |
| 2 | L2₹30.9 L+₹2.0 L (7.05%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹32.0 L+₹3.1 L (10.9%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹33.0 L+₹4.1 L (14.3%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹35.0 L+₹6.2 L (21.3%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Sept 2021, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIR MAINT OF CERTAIN INTERNAL WIRING DISTRIBUTION BOARDS AND REPLACEMENT OF CONVENTIONAL HIGHBAY LIGHTS WITH LED TUBELIGHTS AND CONNECTED REPAIRS IN ETD AND MISC DEPARTMENT UNDER AGE EM II IN GE C KIRKEE
2021_MES_465675_1
8496/E8 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹90,000
Yes
27 Sept 2021
5 Aug 2021
3 Sept 2021
5 Aug 2021
1 Sept 2021
20 Aug 2021
5 Aug 2021 - 19 Aug 2021
Amount
Taking down carefully existing unserviceable aluminum / copper point wiring of any description & in any position with and including existing steel conduit / PVC Conduit / Casing caping fixed on surface/wall/angle/girder and including all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, sockets, etc including sunken boxes/junction boxes and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed by Engineer in Charge.
M&L for point wiring in PVC coduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and including PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 2 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 2 above but point wiring for one 5 pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
M&L for point wiring in PVC casing & caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl item No 6 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables of 1.5 sqmm Size.
All as per Srl item No 6 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 6 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All as per Srl item No 6 above but point wiring for one 5 pin socket outlet, 15 Amps & 5 Amp on independent board using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor cable.
Material and labour for point wiring for one light/ fan/ bell point controlled by one switch in stove enmelled steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arragements made out from 20x1mm flat aluminium strip including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire including suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylam sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall complete all as specified and directed by Engineer in Charge.
All as per Srl item No 11 above but point wiring for 5 pin socket outlet, 5 Amps on same board with other switches.
All as per Srl item No 11 above but point wiring for 5 pin socket outlet, 5 Amps on independent board.
All a s per Srl item No 11 above but point wiring for one 5 pin switch socket outlet combination, 15 Amps & 5 Amp (independent) with using 2.5 sqmm two run and one run 2.5 sqmm (nominal area) stranded copper conductor.
Supplying & fixing switch flush type, 5 Amps, single pole, one way, 230 volts AC circuit complete all as specified & directed by Engineer in Charge.
Supplying & fixing switch flush type, 5 Amps, Bell push, flush type , 230 volts AC circuit complete all as specified & directed by Engineer in Charge.
Supplying & fixing socket outlet, 5 pin, 5 Amps, flush type, multipurpose, 230 volts AC circuit complete all as specified & directed by Engineer in Charge.
Supplying & fixing switch flush type, 15 Amps, single pole, one way , 230 volts AC circuit complete all as specified & directed by Engineer in Charge.
Supplying & fixing Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type , flush type, 230 volts AC circuit complete all as specified & directed by Engineer in Charge.
Supplying & fixing ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified & directed by Engineer in Charge.
Supply and fixing in replacement Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed by Engineer in Charge.
Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories including conduit or casing caping and including making good to the disturbed wall and painting the same with matching paint as of existing wall complete all as specified and directed by Engineer in charge.
Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 1.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm size steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 1.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed by Engineer in charge.
Material & Labour for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm size steel conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed by Engineer in charge.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC non metallic conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New 20 mm size steel conduit and including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,green in colour , as earth contuinity wire all as specified and directed by Engineer in charge. (Note for item No 23 to 26) :- Two runs of cables & one run of continuous earth wire in new PVC casing and caping / PVC non metallic conduit/ steel Conduit shall be measured as one length ).
Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and directed by Engineer in charge.
Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed by Engineer in Charge.
Material and labour Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed by Engineer in Charge.
Material and Labour for Sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volt grade conforming to IS drawn through Existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed by Engineer in Charge. (Note for item No 28 to 30) - Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length.
Disconnecting and taking down old existing damaged metallic rigid steel conduit of any size and any type from any height with all fittings complete all as directed by Engr-in-Charge.
Supply & fixing hot galvanised rigid steel conduit 25 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge. Make - Jindal/Kalinga/ BEC as approved by GE.
Supply & fixing hot galvanised rigid steel conduit 20 mm dia, light grade, at any height with and incld. of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks, screws, clips, plugs, clamps etc. for securing , conduits etc. to walls,ceiling, steel joists etc. complete all as directed by Engr-in-Charge. Make - Jindal/Kalinga/ BEC as approved by GE.
Disconnecting and taking down old switch fuse type distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and M&L for making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S&F, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507748 or equivalent in Schneider/L&T as approved by GE. Note : MCCB & MCB required for the work shall be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507748 or equivalent in Schneider/L&T as approved by GE. Note : MCCB & MCB required for the work shall be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 6 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507748 or equivalent in Schneider/L&T as approved by GE. Note : MCCB & MCB required for the work shall be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507745 or equivalent in Schneider- Acti-9/ L&T-Exora as approved by GE. Note : MCCB & MCB required for the work shall be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507611 or equivalent in Schneider/L&T as approved by GE.
S&F, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 507612 or equivalent in Schneider/L&T as approved by GE.
S&F, Thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed equivalent to Make Legrand-DPX3 cat No 420057 or equivalent in Schneider-NSX/L&T as approved by GE.
S&F, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed equivalent to Make Legrand-DPX3 cat No 420057 or equivalent in Schneider-NSX/L&T as approved by GE.
S&F, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 25 KA & shall be Ics=Icu 100%, complete all as specified and directed equivalent to Make Legrand-DPX3 cat No 420057 or equivalent in Schneider-NSX/L&T as approved by GE.
Supplying & fixing MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed by Engineer in charge. Make - Legrand/ABB/L&T/ Seimens as approved by GE.
Supplying & fixing MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and directed by Engineer in charge. Make - Legrand/ABB/L&T/ Seimens as approved by GE.
Removing of old HPMV / MH high bay light fittings at 12 to 15 mtr height carefully without dammaging connector or ceiling rose. If any damage made to the government fropety the same shall be repaired by the contractor without any extra cost complete all as specified and as directed by Engineer in charge.
Supply and fixing at 5 to 9 mtr height-150W Industrial LED Highbay luminaire with >135Lm/Watt, Powder coated PDC Aluminium body & PC Optical Lenses with toughened glass complete all accessories having IP 66 degree of protection, power factor >0.95,THD<10%, potted driver, Internal Surge Protection-5KV & External Surge Protection-10KV,LED of make from List of make including connection with and including 1.5 sqmm three core cable from connector or ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge. NOTE :- The quoted rates are deemed to be inclusive of the cost of Nut-bolts, washers or clamps required to be replaced if old one are found unserviciable or of diferant size/shape for completion of work.
S&F of MS box 1.6 mm thick 150 x200 mm size with and including 3 mm thick hylam sheet for mounting/fixing of two No 15 A piano type switgh , one 5/15 A multipupose socket and one 450 watt dimmer duly cutting driling etc including fixing matarial complete all as specified and directed by Engineer in charge. NOTE :- maximum number boxes are to be fix on steel stucture by welding / driling of hoes etc and rate quoted by contractor shall be deemed to be inclusive of cost towards welding/fixing.
S&F of MS box 1.6 mm thick 100 x175 mm size with and including 3 mm thick hylum sheet for mounting/fixing of one No 15 A piano type switgh , and one 450 watt dimmer duly cutting driling etc including fixing matarial complete all as specified and directed by Engineer in charge. NOTE :- maximum number boxes are to be fix on steel stucture by welding / driling of hoes etc and rate quoted by contractor shall be deemed to be inclusive of cost towards welding/fixing.
Removing of old main switch after disconecting the incoming and outgoing cables and supply and fix MCCB thermal magnetic release, four pole, 25 KA, 63 Amps, Make Legrand (Cat No 420053) or equivalent in L&T /ABB as approved by GE with one way metal enclosure of Make Legrand (Cat No 507801) or equivalent in L&T /ABB and making conections of cables with suitable size nut bolt etc including making good the disturbed suface of wall including material complete all as specifide and directed by Engineer in charge.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release, four pole, 25 KA, 100 Amps, Make Legrand (Cat No 420055) or equivalent in L&T /ABB as approved by GE with one way metal enclosure of Make Legrand (Cat No 5078 01) or equivalent in L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complete all as specifide and directed by Engineer in charge.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix MCCB thermal magnetic release, four pole, 25 KA, 160 Amps, Make Legrand (Cat No 420057) or equivalent in L&T /ABB as approved by GE with one way metal enclosure of MAke Legrand (Cat No 5078 01) or equivalent in L&T /ABB and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specifide and directed by Engineer in charge.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix Industrial plug and socket board TP 32 Amps, including plug top and MCB "C" curve 10 KA 32 Amps Make Legrand (Cat No 5078 18 and 4086 58) or equivalent in L&T /ABB as approved GE and making conections of cables with suitable size nutbolt etc including making good the disturbed suface of wall including material complate all as specifide and directed by Engineer in charge.
Removing of old main switch after disconecting the incoming and out going cables and supply and fix one way metal enclosure of Make Legrand (Cat No 5077 93) or equivalent in L&T/ABB as aprroved by GE and MCB "C" curve TPN 10 KA 32Amps Make Legrand (Cat No 4086 80) or equivalent in L&T/ABB as approved by GE and making conections of cables with suitable size nutbolt etc. including making good the disturbed suface of wall including material complete all as specified and directed by Engineer in charge.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and directed by Engineer in Charge.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral links complete all as specified and directed by Engineer in Charge.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, at any height, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for mounting Air Circulator / Exhaust Fan / Ceiling Fan for fixing arrangements complete all as specified and as directed by Engineer in Charge.
Dismantling and Taking down unserviceable existing light fittings 1X 40 Watt / 2X 40 Watt/ 70 watt or any other wattage security lihgts of any size and capacity from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge.
Supplying, fixing, connecting up to existing/new ceiling rose and testing industrial box type batten with precoated CRCA body. LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser ,LED lamp efficay -110 Lum/W ,THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9 including connecting with 23/0.0076 copper conductor flexible twisted three core cable including all accessories for fixing on steel trusses / false ceiling including dismantling of old fittings all as specified & directed. Make crompton cat no- LT8-20-865 or equivalent from list of make as approved by GE.
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED luminarie made up of precoated CRCA housing provided with cum reflector finished in white powder coating, completely prewired with accessories up to terminal block suiatble for 2x 20W 4 feet long LED tubes(High Lumen-110 Lumen/Watt) and including connecting with 23/0.0076 copper conductor flexible twisted three core cable and fixing arrangements for fixing on steel trusses / false ceiling including dismantling of old fittings all as specified & directed. Make crompton cat no LT8-20-865 are equivalent from list of make as approved by GE. Note for item No 59 and 60:- (i) Stove enamelled black steel conduit or cahin only will be measured and paid under relevant items of this schedule. (ii) Quoted rate is deemed to be inclusive of conduit fittings and bell mouthed threaded sockets.complete all as specified & directed. (iii) Quoted rate is deemed to be inclusive any misc materials required for fixing new luminaries.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 12W 6500K LED recessed mounting round downlight with PDC aluminium body, CRI > 80 beam angle 36 degree including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed by Engineer in charge. Make crompton cat no-CDR212-12-40-SL-NWH are equivalent from list of make as approved by GE.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 18W 6500K aesthetically designed 1x1 LED surface mounting in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed by Engineer in charge. Make crompton cat no-LCTLSNE-18-FO-CDL or equivalent from list of make as approved by GE.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 13W 6500K 1x1 LED recess mounting in grid/armstrong type ceiling including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed by Engineer in charge.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 18W , 6500K LED trimless round surface panel light including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed. Make crompton, Cat no- LCDSPLN-R-18-CDL or equivalent from list of make as approved by GE.
Supplying, fixing, connecting up to existing/new ceiling rose and testing 3W 6500K LED recessed mounting round downlight with PDC Al body CRI > 80 beam angle 36 degree including suitable LED driver and connecting with 23/0.0076 copper conductor flexible twisted two core cable to existing/new ceiling rose and including mounting accessories complete all as specified & directed. Make crompton cat no-CDR210-03-40-SL-NWH or equivalent from list of make as approved by GE.
Supplying, fixing, connecting in at any height up to existing/new ceiling rose and testing LED batten with 20 W LED light source in integral module with polycarbonate/Acrylic diffuser more than 85%efficiency of light with LED lamp efficay as 110 Lum/W THD ≤15% with operating voltage range 100-300V, driver efficency >85%, surge voltage withstand 2.5 KV , power factor ≥0.9, and connecting with 23/0.0076 copper conductor flexible twisted three/ two core cable fittings conection complete all as specified & directed by Engineer in Charge. Make crompton, cat no-CCS-100-20-65-HL2-DP-NWH or equivalent from list of make as approved by GE. NOTE - Quoted rate is deemed to be inclusive of any misc materials required for fixing new luminaries.
Om Construction
AN-ICON Engineering Technologies And Infrastructure Developments Pvt. Ltd
JP ENTERPRISES
M/S. Niksun Electro-Infra Private Limited
SHAILENDRA B TULSANI
PAMS ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .