| Sl No | Description | Qty | Unit | HARNEK SINGH CONTRACTOR L4 | GURINDER PAL SINGH CONTRACTORS L5 | SITA RAM CONTRACTOR L3 | THE TOE CO OP L/C SOCIETY L2 | Star construction company L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | WATER SUPPLY (13) Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (xxii) 110mm o/d PVC pipe of 4 Kgf. / sqcm | 1,500 | Mtr | 309 ₹4,63,500 | 328 ₹4,92,000 | 350 ₹5,25,000 | 266.6 ₹3,99,900 | 200 ₹3,00,000 Lowest |
| 2.00 | (xxix) 200mm o/d pipe of 2.5 Kgf. / sqcm | 1,500 | Mtr | 506 ₹7,59,000 | 533 ₹7,99,500 | 500 ₹7,50,000 | 436.61 ₹6,54,915 | 400 ₹6,00,000 Lowest |
| 3.00 | (xxii) 110mm o/d PVC pipe of 4 Kgf. / sqcm (STRINGING ONLY) | 1,000 | Mtr | 23 ₹23,000 | 24 ₹24,000 | 20 ₹20,000 | 19.92 ₹19,920 Lowest | 25 ₹25,000 |
| 4.00 | (xxix) 200mm o/d pipe of 2.5 Kgf. / sqcm | 1,000 | Mtr | 45 ₹45,000 | 45 ₹45,000 | 40 ₹40,000 | 38.9 ₹38,900 Lowest | 50 ₹50,000 |
| 5.00 | (27) Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).(B) Class PN-1.6 as per ISI ((b)) 100mm i/d Sluice Valves flanged | 4 | each | 6,483 ₹25,932 | 7,196 ₹28,784 | 7,000 ₹28,000 | 6,151.08 ₹24,604.32 | 6,000 ₹24,000 Lowest |
| 6.00 | ((d)) 200mm i/d Sluice Valves flanged | 2 | each | 16,425 ₹32,850 | 18,231 ₹36,462 | 16,000 ₹32,000 | 15,582.54 ₹31,165.08 | 15,000 ₹30,000 Lowest |
| 7.00 | ((f)) 300mm i/d Sluice Valves flanged | 1 | each | 29,609 ₹29,609 | 32,866 ₹32,866 | 30,000 ₹30,000 | 28,090.31 ₹28,090.31 Lowest | 29,000 ₹29,000 |
| 8.00 | (29) Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete. ((d)) C.I Single air valve screwed (Size 50mm) | 10 | each | 2,546 ₹25,460 | 2,724 ₹27,240 | 2,500 ₹25,000 | 2,415.53 ₹24,155.3 | 2,200 ₹22,000 Lowest |
| 9.00 | (66) Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (a) Size 0.6 m. x 0.6 m. | 10 | each | 5,771 ₹57,710 | 6,118 ₹61,180 | 7,000 ₹70,000 | 5,475.65 ₹54,756.5 Lowest | 6,100 ₹61,000 |
| 10.00 | (a) Size 0.9 m. x 0.9 m. | 15 | each | 8,507 ₹1,27,605 | 8,932 ₹1,33,980 | 9,000 ₹1,35,000 | 8,071.14 ₹1,21,067.1 Lowest | 9,000 ₹1,35,000 |
Tender Value
₹23.4 L
EMD Value
₹46,702
Closing Date
18 Aug 2025, 10:00 amClosed
EXECUTIVE ENGINEER KANDI CANAL 3 DIVISION
EXECUTIVE ENGINEER KANDI CANAL 3 WRD PUNJAB HOSHIARPUR
ESTIMATE FOR RESTORATION OF UNDERGROUND UPVC PIPE WATER COURSE OF DIRECT OUTLET AT RD 72456 MTR AND LAYING OF UPVC PIPE LINE FOR SPLIT OUTLET AT RD 72179 MTR OF KANDI CANAL STAGE 2
2025_WR_146252_1
9/2025-26
Open Tender
Civil Works
Item Rate
75 days
HOSHIARPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
₹46,702
Yes
5 Sept 2025
1 Aug 2025
18 Aug 2025
1 Aug 2025
18 Aug 2025
1 Aug 2025
Amount
WATER SUPPLY (13) Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (xxii) 110mm o/d PVC pipe of 4 Kgf. / sqcm
(xxix) 200mm o/d pipe of 2.5 Kgf. / sqcm
(xxii) 110mm o/d PVC pipe of 4 Kgf. / sqcm (STRINGING ONLY)
(xxix) 200mm o/d pipe of 2.5 Kgf. / sqcm
(27) Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).(B) Class PN-1.6 as per ISI ((b)) 100mm i/d Sluice Valves flanged
((d)) 200mm i/d Sluice Valves flanged
((f)) 300mm i/d Sluice Valves flanged
(29) Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing , cost of nut bolts & rubber insertion all carriages complete. ((d)) C.I Single air valve screwed (Size 50mm)
(66) Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. (a) Size 0.6 m. x 0.6 m.
(a) Size 0.9 m. x 0.9 m.
Providing , laying, fixing and jointing of UPVC Pipes as per isi- 4985 along the trench and laying the same in trenches to correct alignment and gradient , cutting, jointing and testing as per specifications. (315 mm dia)
BRICK WORK (11.3) First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth
Providing and fixing ISI marked 110 mm dia alfa Valve.
Providing and fixing ISI marked 200mm dia alfa Valve.
Providing and fixing ISI marked 315 mm dia alfa Valve.
Providing and fixing 200 mm dia. bend 90 DEGREE (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 110 mm dia. bend 90 DEGREE (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 315 mm dia. bend 90 DEGREE (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 200 mm dia. bend 45 DEGREE (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 110mm dia. bend 45 DEGREE (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 315 mm dia. bend 45 DEGREE (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 200 mm dia. bend Equal tee (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any. conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 110 mm dia. Equal tee (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any. conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 315 mm dia. bend Equal tee (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any. conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 200 mm dia. SOCKET (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any. conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 110 mm dia. SOCKET(6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any. conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Providing and fixing 315 mm dia. socket (6kg/sqcm pressure ) conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any. conforming to is codes with latest amendments if any at site of work including loading , unloading and rehandling if any.
Excavation by mechanical means (JCB or Hydraulic Excavator) in trenches for pipelines with straight or open cutting in streets or open area including dressing sides, leveling of beds of trenches to correct grade, cutting joint holes, refilling consolidation including the cost of diversion for traffic,, crossing over trenches for access to the houses, watching fencing etc. and removal of surplus soil outside/inside the town involving lead upto 15 m complete in all respect.
10 mm thick cement plaster 1:4 on side walls
10 mm thick cement plaster 1:4 on floors
Any Other Item (CSR + SP)
THE TOE CO OP L/C SOCIETY (BID ID -670793)
SITA RAM CONTRACTOR (BID ID -670864)
HARNEK SINGH CONTRACTOR (BID ID -670696)
GURINDER PAL SINGH CONTRACTORS (BID ID -670712)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .