| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | ₹1.1 Cr | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹1.2 Cr+₹5.4 L (4.89%)Rejected-Finance FRIENDS COLONY STREET A DHANGU ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.2 Cr+₹5.4 L (4.89%) | L2 | Rejected-Finance Rejected being other than lowest |
| 3 | L3₹1.2 Cr+₹9.4 L (8.50%)Rejected-Finance DHANGU ROAD PAHTANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹1.2 Cr+₹9.4 L (8.50%) | L3 | Rejected-Finance Rejected being other than lowest |
| 4 | L4₹1.2 Cr+₹11.6 L (10.5%)Rejected-Finance SAHEED UDHAM SINGH NAGAR THANDI KHUEE SUJANPUR PATHANKOT 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | ₹1.2 Cr+₹11.6 L (10.5%) | L4 | Rejected-Finance Rejected being other than lowest |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
5 Apr 2021, 6:00 pmClosed
HQ CE Pathankot Zone
HQ CE Pathankot Zone, Pathankot
PROVN OF DEFI TECH ACCN (OTM) AT KLP FOR 200 MDC AT PATHANKOT
2020_MES_403138_2
CEPZ-23/2019-20
Open Tender
Civil Works
Lump-sum
330 days
GE South Pathankot
As per tender
7 documents required · 7 mandatory
₹1,000
GE South Pathankot
₹2.0 L
Yes
29 Jun 2021
10 Mar 2021
7 Apr 2021
10 Mar 2021
5 Apr 2021
24 Mar 2021
Amount
Lumpsum price worked out by the contractor for Building works as listed in Schedule 'A' Part-I.
Lumpsum price worked out by the contractor for Internal water supply works as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the contractor for Internal electrification works as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the contractor for Plumbing works as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the contractor for Road and Path works as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the contractor for Area Drainage works as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the contractor for Sewage Disposal works as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the contractor for External Water Supply works as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the contractor for External Electrification works as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the contractor for Site clerance, excavation and earth works as listed in Schedule 'A' Part-X
Schedule 'A' Part-XI (Misc items of works)
Internal Water supply works
Angle valve one way cast coppper alloy, fancy type, chromium plated with cup (bore of pipe 15 mm) all as specified and directed.
Internal Electrification works
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED Lamp 1 x 09W complete all as specified and directed.
S&F double door metallic sheet metal enclouser for DB double door (IP 42/43/ when MCBs to be used SPN 4 way, 240 V with 200 Amp rated bus bar complete all as specified and directed
S&F distribution board iron clad vertical DB double door with IP-54 with mechanical strength as IK-09 protection suitable for MCCB as incomer and MCB as outgoing 415 V 3 Phase 50 HZ 4 Way complete with appropriate size of copper busbar and neutral link complete with one MCCB 4 pole 415 V 40 Amps rating, 16 KA with adjustable thermal magnetic release with rupturing capacity 16 KA of the same make as of distribution board complete all as specified and directed
S&F distribution board iron clad vertical DB double door with IP-43 protection suitable for MCCB as incomer and MCB as outgoing 415 V 3 Phase 50 HZ 8 Way complete with appropriate size of copper busbar and neutral link complete with one MCCB 4 pole 415 V 40 Amps rating, 16 KA with adjustable thermal magnetic release with rupturing capacity 16 KA of the same make as of distribution board complete all as specified and directed
S&F distribution board iron clad vertical DB double door with IP-43 protection suitable for MCCB as incomer and MCB as outgoing 415 V 3 Phase 50 HZ 8 Way complete with appropriate size of copper busbar and neutral link complete with one MCCB 4 pole 415 V 100 Amps rating, 16 KA with adjustable thermal magnetic release with rupturing capacity 16 KA of the same make as of distribution board complete all as specified and directed
Supply, fixing, testing and commissioning of MCB SP 240 Volt 6 Amp to 32 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed
Supply, fixing, testing and commissioning of MCB SP 240 Volt 50 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed.
Supply, fixing, testing and commissioning of MCB SPN 240 Volt 6 Amp to 32 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed.
Supply, fixing, testing and commissioning of MCB SPN 240 Volt 50 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed.
Supply, fixing, testing and commissioning of MCB TP 415 Volt 10 Amp 10 KA capacity having B-curve characteristics connected with suitable lugs, complete all as specified and directed.
S&F blanking plate for MCB DBs complete all as specified and directed.
S&F ceiling fans including assessories single phase 230 V, 1200 mm sweep BEE 5 Star rated complete including connecting with 3 core PVC insulated copper cable multistrandard suitable size from ceiling roase to fan connector all as specified and directed .
S&F Exhaust fan 300/350mm sweep heavy duty including louvers connecting with 3 core PVC insulated copper cable suitable size multi strandard from ceiling rose to connector of Exhaused fan connector all as specified and directed ..
S&F 20W surface/wall mounted batten LED laminar, extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life, CRI>80 (Minimum), PF> 0.95, Luminous efficacy>100 lumens/Watt operating voltage 140 V-240V, CCT (K) > 6500, THD< 10% complete including 20W LED tube rod with all accessories up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
LED Street light with pressure die cast aluminium housing with plycarbonate cover, finless design, dediated peanut optics, > 100 lumen/W system efficacy, minium 2500 system lumens 25W system wattage (including driver), color temperature > 5700K, CRI> 80, IP-65 protection, IK-07 rating. The potted electronic driver with THD<10%, PF> 0.95, LED fitting is complete all as per OEM specified and directed. LED driver and housing is of same make as of light fitting. All type of festing for photometry, electrical and electronics parameters is done in NABL approved labotary complete including GI bracket for fixing LED light bent to shape made out of 40 mm dia GI medium grade pipe not less then 1.5m fixed with 02 Nos MS Clamps made out of flat iron of size 15x6mm fabiricated to shape and fixed with uts bolts and washers and applying two coats of aluminium paint one coat of red oxide primer and making connection with 3 core PVC flexible copper conductor cable of suitable size from ceiling rose to fitting all as specified and directed.
Road works
Providing & applying 2.5 mm thick road marking strips (retro-reflective ) of specified shade/colour using hot thermoplastic material by fully/semi automatic thermoplastic paint applicator machine fitted with profile shoe heater, driven by experienced operator on road surface incl cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc, complete all as specified and as directed.
Stainless steel round road delineator having reflector type red/yellow colour in plastic body protected in side polycarbonated sheet, protected with powder coated wiremesh, cage system mouted, complete all as specified and as directed.
Reflective type cat eye having colour red/yellow to a side, casted aluminium alloy of size 100x100x20 mm with built in steam of suitable length for fixing with protected in side, complete all as specified and as directed.
External water supply works
M&L for making hole of suitable size in 80 mm dia CI pipe in position for making branch connection and making MS clamps two numbers fabricated out of MS plate not less than 10 mm thick 450 mm long and 100 mm wide duly two numbers holes drilled of suitable size on both sides of each flap for nuts & Bolts welding one number socket 40 mm dia in one flap and also making hole of 40 mm dia in MS flap, fixing with 80 mm dia CI pipe with rubber insertion sheet not less than 3 mm thick and suitable size of nuts bolts complete all as specified and directed.
M&L for brick masonary valve pit of size 60x60x75 cm internal dimensions of the chamber including brick masonary with cement mortar 1:6 and flush pointing externally as the work proceeds 23 cm thick wall complete with the following specifications and as directed (i) 10 mm thick plaster in cm 1:6 internally. (ii) PCC 1:4:8 type D-2 100 mm thick in foundation. (iii) PCC 1:2:4 type B-2 50 mm thick for fixing of angle frame and MS plate. (iv) Two coats of synthetic enamel paint to cover internally and externally with two coats of bituminous paint. (v) Angle iron frame 40x40x6mm thick for cover and handle steel with 3 mm thick cover MS sheet with locking arrangements and necessary hinges etc. (vi) Necessary excavation and earth works.
External electrification works
M&L for platform brick masonry with surface finishing using extra cement for the installation of transformer of size 3000x2500x1200 mm complete with chain link fencing and gate all as shown in Drg No CEPZ/C-TD-002/13 sheets 1/5 to 5/5 and as specified and directed.
Material, labour, testing & commissioning of cable end termination indoor, heat shrinkable type suitable for XLPE/PVC cables of size 6 to 16 Sqmm any core with working voltage 1100 volts complete all as specified and directed.
Material, labour, testing & commissioning of cable end termination indoor, heat shrinkable type suitable for XLPE/PVC cables of size 25 Sqmm 4 core to 50 Sqmm 305 crores with working voltage 1100 volts complete all as specified and directed.
Material, labour, testing & commissioning of cable end termination in door/out, heat shrinkable type suitable for XLPE/PVC cables of size 185 to 300 Sqmm 3.5 core with working voltage 1100 volts complete all as specified and directed.
Supply, installing, testing and commissioning of LT feeder pillar box factory made oudoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 65 x 65 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing switchgears/MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC including painting with two coats of red oxide epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for main Panel for Transformer and including provn of the following:-
a) Aluminium Bus bar 400-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation. b) MCCB 4 pole 415 V 3 phase 250 Amp, 35 KA (Thermal magnetic release) Ics= 100% Icu and adjustable overload setting 80% to 100% -01 Nos (incoming) from transformer. c) MCCB 4 pole 415 V 3 phase 40 Amp, 16 KA (Thermal magnetic release) Ics= 100% Icu and adjustable overload setting 80% to 100% -02 Nos (outgoing) for TPN DBs of Block-I and 1 Nos Spare. d) MCCB 4 pole 415 V 3 phase 63 Amp, 16 KA (Thermal magnetic release) Ics= 100% Icu and adjustable overload setting 80% to 100% -05 Nos (outgoing) for TPN DBs of medical equipment load-03 Nos, TPN Block-II and 1 Nos Spare.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32mmx6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :- (i) Rates quoted by the contractor are inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI Protection pipe and GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
(ii) PCC Chamber shall be constructed 500mm away from the edge of earth pit (iii) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (iv) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (v) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
Description all as per Srl No 11.34 here-in-before but using copper plate 60x60cm x3.15mm thick electrode and 20x3mm copper strip as earthing lead (for transformer neutral).
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :- (i) Rates quoted by the contractor are inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI Protection pipe and GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
(ii) PCC Chamber shall be constructed 500mm away from the edge of earth pit (iii) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to the Govt. (iv) For effective visibility, identification and traceability of earth pit (EP) with corresponding earth of equipment and building, markers in metal (Mild Steel) shall be provided. Earth test of earth pit is to be provided with a colour code. The direction regarding the size, shape and colour of the mild steel identification board etc shall be given by the Engineer-in-Charge. (v) On completion of the entire work the contractor shall submit a register/ record showing location of earthing, earth value, date of testing etc to the Engineer-in-Charge.
Supply,fixing, testing & commissioning of LED street light fittings on steel tubular poles of height not exceeding 7.5 mtrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame, for efficiency not less than 100 lumens/Watt, and minimum wattage capacity of 72 W with ingress protection IP 65/66 and external SPD of capacity 10 KV in addition to inbuilt with drive complete, fixed to 40 mm dia medium grade GI pipe bracket of length not less than 1.20 cm bend to 120 degree shape with necessary GI clamps 50mmx6mm MS strip bend to required shape, nut bolts etc and 1.5 Sqmm 3.5 core PVC flexible copper cable from junction box to fitting to be layed /drawn inside steel tubler pole complete and testing on completion all as specified and as directed. Note :- (i) MS Clamp fittings with nut bolts and GI bracket will be measured and paid separately. (ii) Minimum 2 years guarantee period of LED fittings (iii) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt. (iv) Power factor more than 0.9 (v) Contractor shall submit LM 79 and LM 80 test reports from manufacturer from approved laboratory.
M&Lfor GI bracket made out of 40 mm bore light grade bent to required shape of 1.20 mtr long and fixing to pole with GI clamp 50mmx6mm, nut and bolts complete all as specified and as directed.
S&F for LED Decroative Post top for 360 degree indirect light 40 watt IP 65 protection, luminous efficacy > 100 lumen/watt with SPD of capacity 10 KV in addition to inbuilt with drive, made up of Black ABS plastic spigot, spun aluminium canopy, with opal/clear acrylic diffuser suitable for AC 230 Volt all accessories including Hot moulded/FRP junction box and 1.5 Sqmm 3.5 core PVC flexible copper cable from junction box to fitting complete, fixed to 50 mm dia medium grade GI pipe, complete all as specified and directed. Note: GI pipe and PCC will be measured and paid separately. The rate inclusive of SMC junction box & 1.5 Sqmm 3.5 core PVC flexible copper cable.
Air Conditioning works
Supply , install , testing and commissioning of air cooled split unit air conditioner (hi wall split units ) electric driven suitable for operation on single phase, 230 V AC 50 Hz supply, indoor/ outdoor complete with cordless remote control unit and with in built Heating and Cooling arrangement and Digital Inverter twin rotary type compressor of capacity 2 TR BEE 5 star rated with Ozone free refrigerant gas including provision of appropriate size and thickness of copper tubing with suitable insulation from indoor to outdoor units and outdoor to indoor all as specified and directed. Note: The rate quoted deemed to be inclusive of indoor Unit, Outdoor Unit with stands, Copper piping, control wiring from indoor to outdoor complete.
Hot water supply works
Supply and installation, testing of Digital type water heater (geyser), electric suitable for operation on 230V 50 Hz AC, storage type of capacity 25 Ltrs BEE star rated, 5 star rating suitable for minmum 8 bar pressure with nano polymer coated tank, incoloy heating element, rust proof ABS body including all accessories with digital display complete all as specified and directed.
M&L for sheet metal enclosures MCB distribution board single pole neutral with a two pin and earth plug and socket 20 amps 240 volts complete with one single pole MCB of 20 amps complete all as specified and directed.
Supply, fixing and drawig submainwiring with 2 run of single core, 4 sqmm FRLS PVC insulated and unsheathed, multi stranded copper conductor cable using colour code for phase red and neutral black with and including 4 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded cable ingreen colour as earth conductor connected to common earth dully, drawn through and including concealed PVC rigid conduit of suitable size having thickness not less than 1.8 mm (ISI marked) with and including all accessories, complete all as specified and directed.
Summer Appliances works
Supply, installation, commissioning of water cooler fully stainless steel, electric driven single phase having approx storage cap 120 Ltrs with stainless steel tank and anti corrosive blue fins and nominal cooling cap 60 Ltrs complete all as specified and directed.
Supply, install, testing and commissioning of desert cooler electric driven, single phase of approx minmum size 575 x 575x800 mm made out of 0.8mm thick GI sheet for body, with water tank of capacity 50 Ltr made out of 1mm thick and with front grills and side direction grills, suitable for minimum air delivery- 4000 Cum/hr approx 450 mm sweep fan size with mild steel curved blades duly painted with synthetic anti corrosive paint, fitted to body including prewired electric 4 speed switch control and one 6 Amps piano switch. Water immersed pump of suitable capacity 1300 RPM rated suitable for 230 volts, 50 Hz AC supply and one 6 Amps piano switch with fan motor of minimum capacity 105 watt, 1400 RPM, 230 volts, 50 Hz and water inlet pipe with brass float valve of size 15mm and outlet with brass drain plug of 20mm. The pad of 3 sides shall be of honeycomb type, including stand of minimum height 900 mm made out 25mm x 25mm x 3mm MS angle iron, duly coated with weather proof paint of black colour indoor all as specified and directed.
Plumbing work
S&F vitreous china wash hand basin oval shape coloured counter top of bowl size 430x300mm including waste pipe PVC 32mm dia & granite counter top complete all as specified and directed.
M/S SINGH AND ASSOCIATES
M/S INDAN FURNITURE MART
yash paul gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .