Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC C 488 SC PLOT NO 10 EKTA NAGAR NEAR ANANT LEWIS PUBLIC SCHOOL BANAR ROAD NANDRI PO SARAN NAGAR JODHPUR 342015 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.3 L+₹1.2 L (3.83%)Rejected-Finance KATTI GHATI SHIV COLONY ALWAR ALWAR RAJASTHAN 301001 | ALWAR | RAJASTHAN | 301001 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹33.7 L+₹1.6 L (4.88%)Rejected-Finance 10 SUBASH COLONY DEFENCE LAB ROAD RATANDA JODHPUR 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹38.3 L+₹6.2 L (19.2%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹39.9 L+₹7.8 L (24.2%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹42.7 L
EMD Value
₹86,000
Closing Date
3 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (A) Jaisalmer
HQ CWE (A) JAISALMER 345001 (Raj)
REPAIR AND MAINTENANCE OF AC PLANTS UPPER AND LOWER AT 12 WEU, 43 ARMD, 73 ARMD, 26 AMN AND MISC REPAIR WORKS UNDER THE JURISDICTION OF GE (A) JAISALMER
2024_MES_658287_1
84195/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (A) Jaisalmer
₹86,000
Yes
10 Sept 2024
7 Jun 2024
5 Jul 2024
7 Jun 2024
3 Jul 2024
21 Jun 2024
7 Jun 2024 - 12 Jun 2024
Amount
Supply and charge refrigerant gas R-407 in AC plant, of any capacity complete all as specified & directed by Engineer-in-charge.
S&F in repair condensor unit suitable for 12.5 TR compressor complete Including Gas kits, daffle plate, connecting rods, liquid port, dischagre port, service valve, service valve port, copper rods ( any size as requried of site), expender plate, condensor cell, End cover, high pressure realse valve port etc complete all as specified & directed by Engineer-in-charge. Make - make as per existing ground as approved by GE.
M&L for opening end covers of condensor and chiller condenser in and including cleaning of condenser 25 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
M&L for opening end covers of condensor and chiller condenser in and including cleaning of condenser 37/38 TR AC plant by circulating descaling compound by using high pressure pump after discaling including and cleaning the condensor coil by chemical and cleaning with nylone brush according to scale condition for copper tubes and refixing end covers, replacement of gasket set, worn out nut bolt & washers etc complete all as specified and directed by Engineer-in-charge
Supply and replacing of compressor oil 11/25/38TR for compressor as per site complete all as specified & directed by Engineer-in-charge
M&L for servicing servicing of AHU of 11/25/38 TR AC plant including cleaning of filters by cleaning with chemical solution as required at site complete all as specified & directed by Engineer-in-charge. Note : Servicing work to be carried out twice through out the contract period.
Disconnecting the electrical connection & taking down the burnt out motor of capacity 10/7.5 HP from AC Plant and transporting to workshop for repair, dismantling the motor & taking out burnout copper winding and rewinding the same with super enamelled copper wire as per existing guage including replacement of bearings & correcting minor defects, reassembling, incl any machinary works such as welding, grinding, tuning, polishing etc and transporting motor from workshop to site, reinstalled at site, reconnecting, testing and commissioning complete all as specified & directed by Engineer-in-charge.
All as per item No. 7.00 here-in-before but capacity 3 HP motor of cooling tower/ blower motor, 3 Phase, 450 Volts complete all as specified & directed by Engineer-in-charge.
All as per item No. 7.00 here-in-before but 5 HP motor for pump set/ Compressor motor, 3 Phase, 450 Volts complete all as specified & directed by Engineer-in-charge.
S&F in repair V Belt A-47 type Poly F-plus complete all as specified & directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE.
S&F in repair V Belt B-122 type Poly F-plus complete all as specified & directed by Engineer-in-charge. Make : Fenner or equivalent make as approved by GE
S&F in repair V Belt A 1200 A-46 Poly F-plus type complete all as specified & directed by Engineer-in-charge. Make : Fenner or equivalent approved by GE
S&F in repair V Belt A-24 type Poly F-plus complete all as specified & directed by Engineer-in-charge. Make : Fenner or equivalent approved by GE
S&F in repair V Belt B-113 type Poly F-plus complete all as specified & directed by Engineer-in-charge. Make : Fenner or equivalent approved by GE
S&F in repair HP cut out Model 5 MP complete all as specified & directed by Engineer-in-charge. Make : Indfoss or equivalent approved by GE.
S&F in repair LP and HP both cut out made of brass suitable for 25 TR complete all as specified & directed by Engineer-in-charge.
Repair/replacement Moduling Thermostate suitable for 36 TR plant AHU complete all as specified and directed by Engineer-in-charge.
S&F in repair of over load protector relay of existing range & size upto 10/7.5 HP at plant room complete all as specified & directed by Engineer-in-charge. Make : L&T or equivalent approved by GE
Repair/replacement Electric Actuator suitable for 36 TR plant AHU all as specified and directed by Engr-in-Charge.
Repair/replacement Electric Actuator model No R-981-R, 24 V AC/DC suitable for 11 TR plant AHU all as per site directed by Engr-in-Charge. Make :- Rapid control or equivalent make as approved by GE
Repair/replacement Electric Actuator suitable for 25 TR plant AHU model no MS8104F1010 220 volt complete all as per site directed by Engr-in-Charge. Make : Honeywell or equivalent make as approved by GE
S&F in repair expansion valve suitable for 12.5 TR capacity AC plant complete all as specified & directed by Engineer-in-charge.
S&F in repair Suction/water/discharge pressure gauge round type made out of brass with cyphon for AC plant 25/11/38 TR capacity complete all as specified & directed by Engineer-in-charge.
S&F in repair temperature thermometer for 25/11/36 TR AC plant complete all as specified & directed by Engineer-in-charge.
S&F in repair compressor suction/discharge valve 25 TR complete all as specified & directed by Engineer-in-charge.
S&F in repair hot water generator heating coil suitable for hot water generator of capacity 30 kW make:-Emerald, Each coil having capacity of 15 kW (2 Nos) and of the same make as of original including testing and commissioning and making hot water generation plant fully functional to the satisfaction of Engr-in-charge/GE complete all as specified & directed by Engineer-in-charge.
S&F in repair hot water generator heating coil suitable for hot water generator of capacity 24 kW make ; Emerald, Each coil having capacity of 4 kW (6 Nos) and of the same make as of original including testing and commissioning and making hot water generation plant fully functional to the satisfaction of Engr-in-charge/GE complete all as specified & directed by Engineer-in-charge.
S&F in repair hot water generator heating coil suitable for hot water generator of capacity 63 kW make ; Emerald, Each coil having capacity of 07 kW (9 Nos) and of the same make as of original including testing and commissioning and making hot water generation plant fully functional to the satisfaction of Engr-in-charge/GE complete all as specified & directed by Engineer-in-charge.
S&F sprinkler with pvc pipe 40/80mm 04 Nos and clamps nut bolt and all accessories complate for AC plant of 25 TR capacity of cooling tower all as specified & directed by Engineer-in-charge.
S&F in repair water pressure valve made out of brass for AC plant 25 TR capacity complete all as specified & directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe, including provn of one union complete all as specified of size 50 mm bore pipe complete all as specified & directed by Engineer-in-charge.
All as per item No. 31.00 here-in-before but size 40 mm dia
All as per item No. 31.00 here-in-before but size 32 mm dia
All as per item No. 31.00 here-in-before but size 25 mm dia
All as per item No. 31.00 here-in-before but size 20 mm dia
S&F in repair butterfly valve of size 100 mm dia pressure class water type with iron handle complete all as specified & directed by Engineer-in-charge.
All as per item No. 36.00 here-in-before but size 80 mm dia
S&F in repair digital ammeter complete all as specified & directed by Engineer-in-charge. Make :- AE/Schneider
S&F in repair HRC fuse, round type, upto 16 Amps complete all as specified & directed by Engineer-in-charge. Make :- L&T or equivalent make as approved by GE
S&F in repair HRC fuse, DIN type fuse links type HN , Size 00, 100-125 Amps complete all as specified & directed by Engineer-in-charge. Make :- L&T or equivalent make as approved by GE
S&F in repair Contactor 40 Amp AC3 Rating, MNX 40 for complete all as specified and directed by Engineer-in-charge. Make: BCH/siemens/L&T
S&F in repair Contactor 32 Amp AC-3 rating, MNX 32 complete all as specified and directed by Engineer-in-charge. Make : BCH/siemens/L&T
S&F in repair Contactor 25 Amp AC3 Rating, MNX 25 complete all as specified and directed by Engineer-in-charge. Make : BCH/siemens/L&T
S&F in repair Contactor 18 Amp AC3 Rating, MNX 18 complete all as specified and directed by Engineer-in-charge. Make : BCH/siemens/L&T
S&F in repair Contactor 12 Amp AC3 Rating, MNX 12 complete all as specified and directed by Engineer-in-charge. Make : BCH/TC/L&T
S&F in repair Contactor 9 Amp AC3 Rating, MNX 12 complete all as specified and directed by Engineer-in-charge. Make : BCH/Legrand/L&T
S&F in repair Overload relay range 14 - 23 Amps complete all as specified and directed by Engineer-in-charge. Make : BCH/TC/L&T
S&F in repair timer 0-120 Sec suitable for panel of AC plant complete all as specified and directed by Engineer-in-charge. Make : BCH/C&S/L&T
S&F in repair MCB TPN 40 to 100Amp 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB TPN 16 to 32 Amp, 'C', 415V, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB TP 20/63 Amp 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB SP 6 to 32 Amp complete all as specified and directed by Engineer-in-charge.
S&F in repair MCB SPN 6 to 32 Amp,240V, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 400 Amp 36 KA complete all as specified and directed by Engineer-in-charge. Make :- Havells/L&T/Scheneider
S&F in repair MCCB TP 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 200 Amps 36 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 250 Amps 36 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 125 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair MCCB TP 160 Amps 16 KA complete all as specified and directed by Engineer-in-charge.
S&F in repair indicator lamp LED type complete all as specified and directed by Engineer-in-charge
S&F in repair single phase preventor having five protection complete all as specified and directed by Engineer-in-charge. Make : minilac/EAPL/Technica
S&F in repair push button switch 220 Volts, 15 Amps all as specified and directed by Engineer-in-charge
S&F replacement/ renewal of fins of cooling tower of AC plant of 11/25/38 TR capacity and taking out old worn out finns complete in all respect all as specified &directed by Engineer-in -charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 25 TR carefully without damaging any other electronic control system and S&F new PCB assembly alongwith display and software update cotrol, testing and cmmissioning complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 38 TR carefully without damaging any other electronic control system and S&F new PCB assembly alongwith display and software update cotrol testing and cmmissioning complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 25 TR carefully without damaging any other electronic control system and repair/replacement of U/serviceable battery, LED, transistors, capacitors, inductors, diodes, switches and software update control making it all functional in all respect and refixing testing complete all as specified and directed by Engineer-in-charge.
Dismantling and taking down unserviceable PCB assembly control AC plant 38 TR carefully without damaging any other electronic control system and repair/replacement of U/serviceable battery, LED, transistors, capacitors, inductors, diodes, switches and software update control making it all functional in all respect and refixing testing complete all as specified and directed by Engineer-in-charge.
S&F in repair air release valve suitable for chiller water pipeline of 11/38/25 TR capacity AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair drier filter for 25 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair drier filter for 38 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair water flow switch for 38 TR AC plant as per site complete all as specified and directed by Engineer-in-charge . (Make :- as per existing or ISI mark)
S&F in repair water flow switch for 25 TR AC plant as per site complete all as specified and directed by Engineer-in-charge . (Make :- as per existing or ISI mark)
S&F in repair temperature sensor for 25 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair temperature sensor for 38 TR AC plant complete all as specified and directed by Engineer-in-charge.
S&F in repair liquid line valve for 25 TR AC plant complete all as specified and directed by Engineer-in-charge.
M& L for Repair/cleaning and painting of housing of cooling tower of 11/25/38(or any other capacity) TR capacity AC plant, including repair of axial flow fan with adjustable angle and motor, replacement of unserviceable/torn net complete all as specified and directed by Engineer-in-charge .
S&F in repair Y-strainer of dia 100 mm with complete fittings, nut-bolts etc all as specified and directed by Engineer-in-Charge Make-Castle/Sant
M&L for repair and making good PCC plinth/piller and base foundation for cooling tower by using 1:2:4 concrete (using 40mm /20mm aggregate), and fixing with suitable MS channel with all fitting acessories, nuts & bolts including necessary plastering work and all as directed by engineer-in-charge.
M&L for repair and making good PCC plinth/base for Pump set (10 HP) by using 1:2:4 concrete and fixing with suitable MS channel base plate with all fitting acessories, nuts & bolts etc, incl necessary plastering works (L,B,H all are as existing) and all as directed by engineer-in-charge.
S&F in repair copper tube of dia 3/4" complete all as specified and directed by Engineer-in-Charge.
S&F in repair copper tube of dia 1/4"/1/2" complete all as specified and directed by Engineer-in-Charge.
Taking down and Supplying laying and fixing with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc jointing and testing LT XLPE insulated galvanized steel wire armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor of cross sectional area 185 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Taking down and Supplying laying and fixing with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc jointing and testing LT XLPE insulated galvanized steel wire armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor of cross sectional area 240 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supplying laying and fixing with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc jointing and testing LT XLPE insulated galvanized steel wire armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor of cross sectional area 6.0 Sqmm 4 Core complete all as specified and directed by Engineer-in-Charge.
Supplying laying and fixing with the wall/ beam/ pipe/passing through pipes or laid under floor/ducts of through walls etc jointing and testing LT XLPE insulated galvanized steel wire armored electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor of cross sectional area 70 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge.
Supplying laying and fixing with the wall/beam/cable tray copper conductor of cross sectional area 2.5 sqmm 4 core all as specified and directed by Engineer- in-charge. Make: polycab/havells/RR Kabel
Material and labour for taking down the 10/7.5 HP Capacity pump from base plate after disconnecting the all pipe lines and transporting (to & fro) workshop for repair, dismantling the complete pump and reassembling/re-fixing in original position, testing & commissioning complete all as specified & directed by Engineer-in-charge with the replacement of the followings:-.
Casing Ring
Impellar ring
Impellar
Coupling seal
Coupling rubber
Shaft/sleeve
Bearings for pump
All as per item No. 88.00 here-in-before but 5 HP complete all as specified and directed.
Casing Ring
Impellar ring
Impellar
Coupling seal
Coupling rubber
Shaft/sleeve
Bearings for pump
All as per item No. 88.00 here-in-before but 3 HP complete all as specified and directed.
Casing Ring
Impellar ring
Impellar
Coupling seal
Coupling rubber
Shaft/sleave
Bearings for pump
M&L in replacement of pipe galvanised iron 'Medium grade' class fixing on wall, floor etc complete including fitting of size 80 mm complete all as specified and directed.
All as per item No. 115.00 here-in-before but size 50 mm
All as per item No. 115.00 here-in-before but size 40 mm
All as per item No. 115.00 here-in-before but size 25 mm
All as per item No. 115.00 here-in-before but size 20 mm
Disconnecting and taking down unserviceable service tank (PVC 1000ltr cap ) and supply & fixing new service tank of cap 1000 ltrs with all fittings and fixtures including pepairing of existing PCC plinth/piller, base foundation (L,B,H all are same as existing), by using 1:2:4 concrete (using 40mm/20mm aggregate), including necessary plastering work and complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down unserviceable service tank (PVC 2000ltr cap ) and supply & fixing new service tank of cap 2000 ltrs with all fittings with 3-layers and fixtures including pepairing of existing PCC plinth/piller, base foundation (L,B,H all are same as existing), by using 1:2:4 concrete (using 40mm/20mm aggregate), including necessary plastering work and complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 25x4mm means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 connected to earthing test point erminal all as specified or indicated including testing on completion. Note : 7.5 mtr GI Strip upto test point including in this job complete all as specified and directed by Engineer-in-Charge.
M&L in repair chilled water pipeline MS pipe 100 mm dia including testing & commissioning C- CLASS complete all as specified and directed by Engineer-in-Charge.
S&F in repair change over switch of 63 amp , 430volt, three phase complete all as specified and directed by Engineer-in-charge. As per exisiting make and size.
S&F in repair air filter for AHU of 11/25/38 TR capacity ac palnt complete all as specified and directed by Engineer-in-charge. As per exisiting make and size.
M&L for painting to all equipments of central AC plants including piping, condensor, cable tray etc complete all as specified and direted by Eng-in-charge
M&L for taking out damaged/worn out chilled water piping insulation and supply and fix new chilled water piping (80/100) insulation with 10mm thick EPS (thermocole) pipe section fixed with hot bitumin and finished with two coats sand cement plaster and GI chicken wire mesh complete all as per existing and making good the disturbed surface complete all as specified and direted by Eng-in-charge
Disconnecting and isolating the semi sealed compressor of AC plant of 12.5 TR capacity from its installed position by placing dummy plates to suction and discharge valves, opening of the compressor, removing of the internal parts, cleaning of all parts thoroughly, overhauling of the compressor, replacing of worn out parts such as crank shaft, pistons, CR assembly, suction reeds, discharge reeds, DV stopper, ORP valve, oil filter screen, piston rings and gasket set, including rewinding of compressor and reassembling of the all internal parts after replacing the worn-out parts, refixing back, removing of the dummy plate, oil charging and checking oil pressure, vacuumising and leak testing and testing the compressor completely all as directed by Engineer-in-Charge. Note : Compressor oil shall be deemed to be included in the rate quoted. However refrigerant will be measured and paid separately under the relevant item.
M/s Yash Electrical and Maintenance
Panwar Electricals
star electricals
Akarsha Enterprises
Radhe Krishn Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .