Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.5 LAccepted-AOC 126 BOTAHGHULI OPP BOR NAMGHAR PANJABARI GUWAHATI KAMRUP ASSAM 781037 | KAMRUP METRO | ASSAM | 781037 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹35.6 L+₹14.1 L (65.5%)Rejected-Finance A MELACHAKAR T P CHALIHA ROAD SIVASAGAR SIVASAGAR SIBSAGAR ASSAM 785640 | SIVASAGAR | ASSAM | 785640 | L-2 | Rejected-Finance Bidder is Not L-1 | |
| 3 | L-3₹49.0 L+₹27.5 L (127.9%)Rejected-Finance | L-3 | Rejected-Finance Bidder is Not L-1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically not acceptable since Bidder is not meeting BQC. | |
| 5 | Rejected-Technical NEAR LIONS CLUB KOTHAMANGALAM ERNAKULAM KERALA 686691 | ERNAKULAM | KERALA | 686691 | - | Rejected-Technical Technically not acceptable Bidder not meeting BQC |
Tender Value
Refer Docs
Closing Date
23 Jun 2021, 3:00 pmClosed
Deputy General Manager (M and C)
IndianOil Corporation Limited Northern Region Pipeline, P.O. Panipat Refinery Baholi, Panipat 132140 Phone -0180- 2578851
AC interference mitigation measures due to overhead HT line crossings in Panipat-Jalandhar LPG Pipeline (96-273 KM) in steady and fault state conditions.
2021_NRPNP_135695_1
PNP21004
Open Tender
Electrical Works
Works
120 days
As per nit clause 5 and Chapter 1 clause 1.3.
As per tender document.
11 documents required · 11 mandatory
Exempted
25 Sept 2021
3 Jun 2021
24 Jun 2021
3 Jun 2021
23 Jun 2021
3 Jun 2021
Amount
Supply Items
Supply of Solid State Diode Decoupling Device of approved make including required length of cable as per specifications for protection of pipeline at HT line crossing locations
Supply of earthing Electrode as per Technical Specification
Service Items
Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge.
Installation of Earthing Electrode at 11 locations including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of grounding cell etc. all complete with required material, excavation, backfilling etc. as per specification and directions of Site Engineer / Engineer-in-Charge.
Excavating trenches of required width for pipes, cables, etc. including excavation for sockets, and dressing of sides, ramming of bottoms, depth exceeding 1.5 m, but not exceeding 3 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm. (Rate is over corresponding basic item for depth upto 1.5 metre).
Composite Items
Supply, installation, testing & commissioning of DAC type Test Lead Point (TLP) with Ingress Protection IP:55 fabricated MS Sheet (Thickness : 3 mm top/side/rear/front & 5 mm : Bottom plates) with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.
Corrosion coupon with 1 sq. cm bare metal with 2 lead wire of 5 m each
Basics Techno Services Pvt Ltd
Corrosion Matters
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .