Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹15.4 L+₹4.6 L (43.0%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹15.5 L+₹4.8 L (44.5%)Rejected-Finance 00 KHATA NO 514 4357 PLOT NO 169 3484 KESHARA BHUBANESWAR KHURDA KHORDHA ODISHA 751007 | KHORDHA | ODISHA | 751007 | L3 | Rejected-Finance Rejected |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
16 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Subroto Park
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2024_MES_643123_1
GE/SP/TOKEN-68/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) Subroto Park Delhi Cantt
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) Subroto Park
₹43,000
Yes
29 Apr 2024
19 Feb 2024
18 Mar 2024
19 Feb 2024
16 Mar 2024
4 Mar 2024
Amount
Overhauling and servicing of split type ACs 1.5 Ton / 2.0 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the A/C from existing location, refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) washing the condensor and cooling coil complete with chemical followed with pressurized water jet complete as required and cleaning with air blower and testing complete (b) Checking / examine operation of condensor, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system (cooling) and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor (g) Checking the functional of electronic remote control unit to ensure satisfactory functioning of unit complete all as specified and as directed
All as per above item No 01 but window type AC of capacity 1.5 / 2.0 TR
Labour only to convert Split / Window AC 1.5 / 2.0 TR from cooling mode to heating mode by necessary adjustments in electrical wiring / interlocking as required in existing heating element / heat pump / reverse solenoid valve including testing the unit and necessary modification / adjustment in remote control unit for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of solinoid valve of Split type AC of Cap 1.5 / 2.0 TR including additional copper tubing of any size brazing work, pressure testing dehydraion and necessary modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and as directed by Engineer-in-charge
Supply & fixing in replacement of solinoid valve of Window type AC of Cap 1.5 / 2.0 TR including additional copper tubing of any size brazing work, pressure testing dehydraion and necessary modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and as directed by Engineer-in-charge
Supply & fix in replacement of Starting relay as per existing Make and model complete all as specified and directed.-
Supply & fix in replacement of Starting capacitor 120-150 mfd Make and model complete all as specified and directed-
Supply & fix in replacement of Starting capacitor 36-100 mfd Make and model complete all as specified and directed-
Supply & fix in replacement of Contactor single phase/3 phase for existing capacity and current rating complete all as specified and direced by Engr-in-Charge
Supply & fix in replacement of Running capacitor 3.5 to 6 mfd complete as as specified and directed
Supply & fix in replacement of Running capacitor 36 mfd complete as as specified and directed
Supply & fix in replacement of Running capacitor 45/50 mfd complete as as specified and directed
Supply & fix in replacement of Propeller fan(Aluminium) for split type AC of capacity 1.5 / 2.0 TR complete as as specified and directed
Supply & fix in replacement of Condensor fan motor of any type of Split type ACs of capacity 1.5 /2.0 TR as per existing Make and model complete all as specified and directed
Supply & fix in replacement of blower motor of any type of Split type ACs of capacity 1.5 /2.0 TR as per existing Make and model complete all as specified and directed
Supply & fix in replacement of Blower for split type AC 1.5 / 2.0 TR as per existing Make and model complete all as specified and directed
S&F in replacement compressor of capcity 2.0 TR for split type AC with washers, bolts and nuts single phase 230V 50 Hz working with filling of required gas upto 2 kg R-410A/R 32 refrigerant including brazing of respective copper tubing incl providing of extra insulated copper tubing, leak check, dehydration of the system with compressed nitrogen for leak free area complete all as specified and directed by Engineer-in-Charge. Note :- Contactor shall be provide 2 years garrantee/warranty certificate against above said items and incase compreesor get in warranty period should be replace without claiming extra cost.
S&F in replacement compressor of capcity 1.5 TR for split type AC with washers, bolts and nuts single phase 230V 50 Hz working with filling of required gas upto 2 Kg R-410A/R 32 refrigerant including brazing of respective copper tubing incl providing of extra insulated copper tubing, leak check, dehydration of the system with compressed nitrogen for leak free area complete all as specified and directed by Engineer-in-Charge. Note :- Contactor shall be provide 2 years garrantee/warranty certificate against above said items and incase compreesor get in warranty period should be replace without claiming extra cost.
Supply & charging the refrigerant gas R-32/R22/R410 to Split type AC 2.0 TR / 1.5 TR upto required level after detecting & repairing leakage by brazing, provn of extra copper tubing if required improvement of efficiency, testing on full load for satisfactory functioning complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of Copper tubing of dia 5/8" with insulation complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of Copper tubing of dia 3/8" with insulation complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of Copper tubing of dia 1/2" with insulation complete all as specified and directed by Engineer-in-charge
Supply & fixing in replacement of Copper tubing of dia 1/4" with insulation complete all as specified and directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 5/8" complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 3/8" complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 1/2" complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacement of foam insulation for copper tubing of size 1/4" complete all as specified and as directed by Engineer-in-charge
M&L for repair to cordless PCB remote control unit of split type AC of cap 1.5 TR/2.0 TR including replacement of spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed
M&L for repair to cordless PCB remote control unit of split type AC of cap 1.5 TR/2.0 TR, inverter Type including replacement of spare parts and refixing, connection of electrical control circuit, testing for satisfactory functioning complete all as specified and directed
Supply & fixing in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 amps complete all as specified and directed .
Supply and fix in replacemnt of MCB SP 6-32 amps 230 Volt c series 50 Hz Single Phase complete all as specified and directed
M&L for Dismantling,shifting of split type AC of any make & model from one location to another location and refixing the AC with gitties/fasteners, cutting wall/concrete incl arrangement of required T&P, laying of extra insulated copper tubing, positioning of condensing unit and stand, fixing of extra pvc flexible multistranded copper conductor of size 2.5 sq mm and brazing work, leak check, dehydration and topping up of refrigerant gas upto recommended level, connection of drain pipe, making good the disturbed surface including PCC and brick work and testing the unit for satisfactory functioning complete all as specified and directed
M&L for rewinding of condensor fan motor of split type AC of cap 1.5/2.0 TR including replacement of gun metal bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed by Engineer-in-charge
M&L for rewinding of blower fan motor of split type AC of cap 1.5/2.0 TR including replacement of gun metal bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed by Engineer-in-charge
S&F in replacement of unserviceable PVC insulated and PVC round sheathed with stranded coper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 2.5 sqmm 3 core complete all as specified and directed.
S&F in replacement of unserviceable PVC insulated and PVC round sheathed with stranded copper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 4.0 sqmm 3 core complete all as specified and directed by Engr -in-charge.
S&F in replacement of unserviceable PVC insulated and PVC round sheathed with stranded copper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 6.0 sqmm 3 core complete all as specified and directed by Engr -in-charge.
M&L Sub main wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistranded copper conductor cable 2 run of 4 sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors alongwith 1 run of 4 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor.
S&F in replacement low density polythylene pipes (LDPE) of pressure rating 6 kg / cm drain pipes of size 20mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge
Labour only for analyzing and rectification of fault to voltage regulators of capacity 5 KVA complete and taking down/segigating of unsv spare parts from voltage stabilizer and fixing of following items complete all as specified and directed all as directed. (Note- Parts required for repair to voltage regulators will be measured and paid separately under the items supply only)
(a) Supply only Main transformer copper wound of capacity 5 KVA as per existing make & model
(b) Supply only Buck & boost relay
(c) Supply only Time delay circuit
(d) Supply only Electronic control card as per existing
(e) Supply only Trigger transformer as per existing
(f) Supply only High/low voltage protection circuit
Supply and fixing in replacemnt of Electronic control circuit board (PCB) of outdoor/indoor unit for CFC free split type AC of capacity 1.5/2.0 TR as per existing make and model complete all as specified and as directed by Engineer-in-charge
Supply and fixing in replacemnt of Electronic control circuit board (PCB) inverter Type of outdoor unit/indoor unit for digital invertor fitted CFC free split type AC of capacity 1.5/2.0 TR as per existing make and model complete all as specified and as directed by Engineer-in-charge
M&L for carrying out leakage testing of split type air conditioner of capacity 1.5 / 2.0 TR of existing make and type, charging dehydrated Nitrogen gas upto 280 PSI in refrigerant system for a period of 24 hours for detecting leakages and repairing of tubing by brazing / welding suitably and repeating the pressure test to obtain 100% leak proof condition in the system, charging the refrigerant gas R-22 / 410-A and testing complete all as specified and directed by Engineer-in-charge
S&F in replacement of body (kit) of window type AC 1.5 TR capacity including body, condesnor coil, cooling coil, blower motor, front grill and outer cover without compressor complete all as specified and as directed by Engineer-in-charge
S&F in replacement of copper tube condesnor assembly suitable for 1.5 TR window type air conditioner of any make complete all as specified and as directed by Engineer-in-charge. Note : - Charging of Refrigerant gas shall be inclusive in quoted rate.
Supply only in replacement of remote control suitable for 1.5 / 2.0 Ton split type AC of existing make and type complete all as specified and as directed by Engineer-in-charge
Supply and installation in replacemnt of voltage stabilizer capcity 5 KVA , AC Supply 180 Volt to 240 Volt , 50Hz fixing on wall all a sspecified and directed by Engr-in-Charge
Supply and installation in replacemnt of voltage stabilizer capcity 3 KVA , AC Supply 180 Volt to 240 Volt , 50Hz fixing on wall all a sspecified and directed by Engr-in-Charge
Labour only to convert Split / Window AC 1.5 / 2.0 TR from heating mode to cooling mode by necessary adjustments in electrical wiring / interlocking as required in removing of existing heating element / heat pump / reverse solenoid valve including testing the unit and necessary modification / adjustment in remote control unit for satisfactory functioning complete all as specified and directed by Engineer-in-Charge.
Taking down the water cooler of any capacity / make / size from site, opening side covers of water cooler and overhauling / servicing of water cooler by carrying out the following works at different location complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning of storage tanks (b) Examine water tightness of stotage tank after cleaning (c) Carry out operations of stop cock, push cock, float valve etc (d) Replace washer & glands of all taps to ensure water tightness (e) Inspect over flow and remove blockage obstruction if any (f) Check and correct earth continuity of electrical items (g) Check thermostate and test its functioning (h) Inspect drain pipe and remove blockage if any (j) Check & correct all electrical wiring and its functioning (k) Testing of water coolers after repairs for satisfactory functioning complete
Taking out old unserviceable compressor of water cooler of capacity 40 / 80 to 60 / 120 litres any make / size and providing new company sealed compressor and connectig up suction and discharge copper pipe including extra copper tubing with brazing work, gas welding, pressure testing of leakage,leakage rectification, vacumising and charging of refrigerant gas R-22/ Non-CFC as applicable upto required level testing comissioning complete all as specified and as directed by Engineer-in-charge
Taking out old unserviceable compressor of water cooler of capacity 150 litres any make / size and providing new company sealed compressor and connectig up suction and discharge copper pipe including extra copper tubing with brazing work, gas welding, pressure testing of leakage,leakage rectification, vacumising and charging of refrigerant gas R-22/ Non-CFC as applicable upto required level testing comissioning complete all as specified and as directed by Engineer-in-charge
M&L in replacement of thermostate switch for water cooler of any make and capacity complete all as specified and as directed by Engineer-in-charge
M&L in replacement of overload protector suitable for compressor for water cooler of any make and capacity complete all as specified and as directed by Engineer-in-charge
M&L in replacement of starting relay kit suitable for any make and capacity of water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Condensor motor of 1/16 or 1/32 or 1/40 HP of water cooler complete all as specified and as directed by Engineer-in-charge
M&L in replacement of Condensor fan blade for 1/16 or 1/32 or 1/40 HP motor suitable for water cooler of any make and capacity complete all as specified and as directed by Engineer-in-charge
M&L in replacement of electric wiring kit suitable for existing water cooler complete all as specified and as directed by Engineer-in-charge
Taking down the desert cooler of any size comprissing of following task at different location complete all as specified and directed by Engineer-in-charge (a) Disconnecting of electric supply and taking down desert cooler from existing location and refixing after overhauling servicing with greasing oiling complete (b) Descaling brushing cleaning of bottom tank (c) Examine water leaking of storafe tank after cleaning and servicing (d) Check & Examine all items i.e Fan motor, pump, regulator, fan blades rectify defecets of minor nature (e) Testing of desert cooler after repair / servicing and fixing position complete.
S&F in replacement of Electric motor for fan 18" / 20" sweep, single phase 3 speed 100% water resistance, 100% dust proof withstand, voltage fluctuation 170 V - 270 V, rust proof totally enclosed with double ball bearing 900-1400 RPM, electric connection with copper cable of appropriate gauage including dismantling of unserviceable electric motor complete all as specified and as directed by Engineer-in-charge
Taking down including rewinding of electrical fan motor with single phase 230 Volt 900-1400 RPM for 300 CuM/Hr to 5000 Cum/Hr capacity as required at site with super enamelled copper winding wire complete all as specified and as directed by Engineer-in-charge
S&F in replacement of 15mm dia PVC pipe,600 mm length for desert cooler complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC distributor with one linlet and three outlet heavy duty complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC elbow 15mm size heavy duty complete all as specified and as directed by Engineer-in-charge
S&F in replacement of PVC / MS blade heavy duty of existing size complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Mild steel bracket for cooler fan of existing size complete all as specified and as directed by Engineer-in-charge
S&F in replacement of submersible pump 230 volts single phase suitable for desert cooler of cap 3000 CuM / Hr to 5000 CuM / Hr complete all as specified and as directed by Engineer-in-charge
S&F in replacement of wood wool pad (set of 03 Nos) heavy duty weight not less than 750 gm suitable for desert cooler of cap 3000 CuM / Hr to 5000 CuM / Hr complete all as specified and as directed by Engineer-in-charge
M&L for attending minor complaints for split AC , water cooler, refrigerator , deep freezer and desert cooler to rectify the minor defects I,e checking of electrical connections, mode of ACs , temprorry defaults all as specified and directed by Engineeer -in- Charge. Notes (a) Contractor will provide well experienced and well conversed men power including Sunday & Holidays. (b) The Refg Mech should be having 4 year experience in the trade or ITI holder in the relevant trade having proper knowledge for repairing work of Refg & AC items.(c) All T&P required for repair work shall be provided by contractor at own arrangement to trade men & helpers (d) All complaints should be attended with in 8 hours. Panelty charges for non attending complaints within 8 hours shall be decided by Engg-in-charge. The cost of man power shall be deemed to be included in the unit rate.
Supply and fixing in replacement of Rigid PVC pipes size of 50 mm dia pressure rating 10 kgf/cm2 fixing on wall by using same size of clamps and screwing on wall up to G+4 building by using ladder/crane or necessary tools and plants including neccesary Tee, color, bend, socket etc complete all as specified and directed by engr-in-Charge.
Supply and fixing in replacement of Rigid PVC pipes size of 40 mm dia pressure rating 10 kgf/cm2 fixing on wall by using same size of clamps and screwing on wall up to G+4 building by using ladder/crane or necessary tools and plants including neccesary Tee, color, bend, socket etc complete all as specified and directed by engr-in-Charge.
Supply and fixing in replacement of Rigid PVC pipes size of 20 mm dia pressure rating 10 kgf/cm2 fixing on wall by using same size of clamps and screwing on wall up to G+4 building by using ladder/crane or necessary tools and plants including neccesary Tee, color, bend, socket etc complete all as specified and directed by engr-in-Charge.
Supply and fixing in replacement of Rigid PVC pipes size of 15 mm dia pressure rating 10 kgf/cm2 fixing on wall by using same size of clamps and screwing on wall up to G+4 building by using ladder/crane or necessary tools and plants including neccesary Tee, color, bend, socket etc complete all as specified and directed by engr-in-Charge.
Supply and fixing in replacement of flexible threded from indoor unit to main line size of 15/20 mm dia pressure rating 10 kgf/cm2 fixing on wall by using same size of clamps and screwing on wall up to G+4 building by using ladder/crane or necessary tools and plants including neccesary items etc complete all as specified and directed by engr-in-Charge.
M&L for cutting of PVC/UPVC/GI pipe and inserting tee size of 50/40/20/15 as per site requirement and connection of drain pipe from indoor uint to pipe line including necessary size Tee and clamping of drain pipe with proper finishing and if required making hole by using drill machine and after done the job plastering by cement and stone aggregate, making good disturbed by white wash or existing colour complete all as specified and directed by Engr-in-Charge.
M&L for refixing of out door unit of any capacity from one floor to another floor or floor to roof top or as per site requirement disconnecting outdoor unit from existing position and refixing as per given site including gas charging upto stasifaction level and copper tubing and insulation from indoor to outdoor complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of stand for outdoor unit duly factory made, powder coated will be fixing on wall up to G+4 building and roof including nut, bolt, washers, etc by using ladder/crane or other tools and plants complete all as specified and directed by Engr-in-Charge.
M&L for drilling/cutting on wall for concealed of AC drain pipe after concealed of drain pipe making putty on wall and matching with existing colour by apply of paint or distepber as per site requirement all as specified and directed by Engr-in-Charge. Notes (a) Contractor will provide well experienced and well conversed men power including Sunday & Holidays. (b) The Refg Mech should 10th passed having 4 year experience in the trade or ITI holder in the relevant trade having proper knowledge for repairing work of Refg & AC items.(c) All T&P required for repair work shall be provided by contractor at own arrangement to trade men & helpers (d) All complaints should be attended with in 8 hours. Panelty charges for non attending complaints within 8 hours shall be decided by engg-in-charge. The cost of man power shall be deemed to be included in the unit rate.
HONEY COLLECTION
Sai Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .