Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹14.9 L+₹92,090 (6.60%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹15.0 L+₹1.0 L (7.32%)Rejected-Finance | L3 | Rejected-Finance Not being L1 |
Tender Value
₹14.3 L
EMD Value
₹28,600
Closing Date
31 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 Works Engrs
HQ 133 Works Engrs, PIN-914133, C/o 56 APO
PROVN OF 63 KVA TRANSFORMERS AND 50 KVA VOLTAGE STABILIZER WITH ALLIED INFRA FOR FD WKSP AT URI UNDER GE 969 EWS
2021_MES_464710_1
CWEK-43/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FD WKSP AT URI UND GE 969 EWS
Class E category b i
7 documents required · 7 mandatory
₹500
GE 969 EWS
₹28,600
HQ 133 Works Engrs
12 Nov 2021
2 Aug 2021
2 Sept 2021
2 Aug 2021
31 Aug 2021
17 Aug 2021
2 Aug 2021 - 12 Aug 2021
14 Aug 2021
60 days
Amount
Supply, installation, testing and commissioning indoor/outdoor type, pole mounted stepdown transformer, 11 KV/415 volts (at full load) AC 3 phase 50 HZ, 63 KVA capacity, core type, double copper wound, Oil immersed, naturally cooled, oil Natural Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having taping at ±2.5% & ±5% on HV side to be charged by means of hands operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measurement by resistance method after continous full load run on an ambient temp of 40 degree celsius. The transformer shall be IS-1180 marked. Make shall comprises for the following:-
Supply and Fixing Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed.
Supply, fixing, commissioning and testing Switch Air break gang operated outdoor type HT 11 KV, tripple pole, 200 Amps, air break fitting type with fixed contacts of phospherous bronze and moving contact of copper with mechanically operated rod from ground level, vertical/ horizontal mounted complete with HT insulator on and including steel frame, operating rod made out of 25mm dia GI pipe medium grade with 12 insulators with test point complete all as specified and directed.
Supply, installation, commissioning and testing voltage stabilizer fully automatic micro processor based control card of capacity 50 KVA, three phase oil cooled with Single phase prevention system, indoor type and designed for input variation between 340 V to 460 V with output voltage stabilized at 415 volt with accuracy of +/- 2.5% and speed of correction 8 V/Sec, no load loss less than 0.5%, operating temp - 15 degree to 45 degree celsius above ambient and unbalanced load complete with first filling of oil complete, all as specified and as directed including additional features as follows: a. High & low voltage cutoff system b. Change over switch to by-pass the system
Supply and erecting in vertical position steel tubular swaged pole type 410 SP-55 (11metre long) with 300mmx300mmx6mm mild steel base plate continuously welded to pole, finial taper, nut, bolts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and applying one coat of red oxide primer for the remaining portion and two coats of aluminium paint beyond 1.5M from ground level/coping and making 30cm black and white strips with two coats of super enameled paint up to 1.5M from ground level/coping complete all as specified and directed. Note:- Earth work, PCC and coping will be measured and paid for separately under respective items.
Supply , laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor 11000 volts grade of size 95 Sqmm, 3 core ISI marked complete all as specified and directed.
Supply , laying and testing cable XLPE insulated screened PVC insulated, armoured, heavey duty electric cable with aluminium conductor, 1100 volts grade, cross-sectonal area 95sq mm, 3 core, ISI marked complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened PVC insulated, armoured, heavey duty electric cable with aluminium conductor, 1100 volts grade, cross-sectonal area 70sq mm, 3.5 core, ISI marked complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated screened PVC insulated, armoured, heavey duty electric cable with aluminium conductor, 1100 volts grade, cross-sectonal area 25sq mm, 4 core, ISI marked complete all as specified and as directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm ISI marked complete all as specified and directed.
Excavation in trenches in not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches in not exceeding 1.5M wide and exceeding 1.5M but not exceeding 3 m in depth and getting out in hard/dence soil complete all as specified and directed.
Returning, filling in including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in soil complete all as specified.
Removing excavated material soil not exceeding 50m and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified.
M&L Sand cushioning to underground cables 8 cm below the cable before laying and 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I. Note :- 1. Dry fine sand of best available quality shall be used. 2. Punned thickness shall be measured and paid.
M&L Plain cement concrete 1:4:8 type D-2, (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete for poles/stays and the like, complete all as specified and directed.
M&L Plain cement concrete 1:3:6 type C-2, (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete for poles/stays and the like, complete all as specified and directed.
M&L Plain cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating and including necessary form work complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick buried directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth strip 32 x 6 mm by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel using GI including PCC (concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm) 8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part-I and specified including provision of earth wire/ strip protected by 40 mm dia medium grade GI pipe including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc and testing on complete, complete all as specified and directed Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised iron strip 32X6 mm and protection pipe of 40mm bore medium grade, GI light grade 20mm bore watering pipe.
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick buried directly in to the ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth wire 4mm dia by means of bolts, nuts thimble check nuts and washers of galvanised iron or steel using GI including PCC ( concrete chamber) 1:3:6 Type C-1 using 20 mm graded stone aggregate with fair finish of internal surface concrete, 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68 mm)8 mesh per inner inch, 80mm thick RCC Pit cover 320mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM and charcole dust and common salt all as shown in electrical plate No-3 MES SSR Part -I and specified including provision of of earth wire/ strip protected by 40 mm dia medium grade GI pipe shall be and including all excavation and earth work & connecting the earth earthing to an earthing test point/ transformer neutral/ body LT panel etc. and testing on completion, complete all as specified and directed. Note :- Quoted rate of earthing shall be deemed to included cost of 7.5 M long galvanised earth wire 4 mm dia and protection pipe of 40mm bore medium grade,GI light grade 20mm bore watering pipe.
Construction of transformer shed for transformer of capacity upto 63 KVA complete all as specified and as per Drg No CESZ/TD-1110/2011 Sheet 1/1 and 2/2 dated 01.12.11 Note : The work for transformer shed shall be completed as per detail mentioned in drawing. The contractor shall visit the office of AGE E/M, GE 969 EWS or this office in working hours for obtaining of said drawings.
Material and labour drop out fuses with insulators mounted on steel frame,for current rating upto 200 Amps 11000 volts ,complete all as specified and directed. Note: Quoted rate is includive of jumpering from cable to drop out insulator including necessary bolts etc.
S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for HT 11 KV complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed
S&F Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed
S&F Disc type insulator porcelain, vitreous 145mm high and 255mm dia ball and socket type , white, brown or green single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified and as directed
S&F ACSR conductor of (weasel) 6/1 X 2.59mm, starching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between etc complete all as specified and as directed.
M/S Khan Hussain & Co.
BINDRA ENGINEERS AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .