Chief Engineer
HQ CE Bhopal Zone SI lines Bhopal 462001
REPLACEMENT OF WATER PIPELINE FROM CI TO DI AT DRONACHAL BHOPAL MILITARY STATION UNDER GE DRONACHAL
2026_MES_797026_1
CEBZ/BPL/TOKEN/26 OF 2026-27
Open Tender
Civil Works
Item Rate
360 days
Bhopal
As per NIT Documents
6 documents required · 6 mandatory
₹2,000
GE Dronachal
₹3.7 L
3 Nov 2026
3 Nov 2026
3 Dec 2026
3 Nov 2026
1 Dec 2026
25 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Taking out the existing CI/DI pipe line of any class, including CI fittings with spigot and socket ends and lead joints of any class/type, for the following sizes, complete as specified and directed. Notes:- (i) While taking out the existing pipe line of any type, adequate arrangements shall be made to ensure that there is no major interruption/breakdown in the water supply. (ii) Existing SCADA-operated valves shall be properly dismantled and re-fixed without any extra cost. (iii) While taking out the existing CI/DI pipe line in the Hills Area, due care shall be exercised to avoid damage to the existing pipe/valve pedestal. Any damage caused during execution shall be made good/repaired by the contractor without any extra cost. | |||||
| 1.01 | 200 mm bore | 2,300 | RM | - | - |
| 1.02 | 200 mm bore | 5,800 | RM | - | - |
| 2Supply, laying, connecting on existing RCC/PCC plinth and testing of DI pressure pipes, ISI marked and conforming to IS 8329:2000 (Reaffirmed 2005), Class K-9, of 250 mm bore, with flanged ends on both sides suitable for “Flange Joint”, in standard working lengths, supplied with ISI-marked rubber gaskets for water service. The pipes shall be internally lined with cement mortar and externally coated with metallic zinc with a finishing layer of bituminous paint, without polyethylene sleeve, including “Flange Joint” with ISI-marked EPDM rubber gasket conforming to IS 5382:1985 (Reaffirmed 2003), having dual hardness of Type-2 (Bulb) and Type-5 (Heel), complete as specified and directed. | |||||
| 2.01 | 200 mm bore | 2,300 | RM | - | - |
| 2.02 | 250 mm bore | 3,500 | RM | - | - |
| 3 | Supply, laying, connecting on existing RCC/PCC plinth and testing of DI pressure pipes, ISI marked and conforming to IS 8329:2000 (Reaffirmed 2005), Class K-9, of 250 mm bore, with flanged ends on both sides suitable for “Flange Joint”, in standard working lengths, supplied with ISI-marked rubber gaskets for water service. The pipes shall be internally lined with cement mortar and externally coated with metallic zinc with a finishing layer of bituminous paint, without polyethylene sleeve, including “Flange Joint” with ISI-marked EPDM rubber gasket conforming to IS 5382:1985 (Reaffirmed 2003), having dual hardness of Type-2 (Bulb) and Type-5 (Heel), complete as specified and directed. | 2,300 | RM | - | - |
| 4Cutting of cast iron pipes in position for insertion of new tees , branches, etc for the following sizes complete all as specified and directed :- | |||||
| 4.01 | 200 mm bore | 5 | EACH | - | - |
| 4.02 | 250 mm bore | 5 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_894007.xls
BOQ • 7.90 MB
TENDER694.pdf
Tender Documents • 1.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .