| 1 | L1₹82.3 LAccepted-AOC C 223 MIANWALI COLONY GURUGRAM 122 001 HARYANA | GURUGRAM | GURUGRAM | HARYANA | 122001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹86.7 L+₹4.4 L (5.31%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L2 | Rejected-Finance Being not lowest tenderer | |
| 3 | L3₹1.0 Cr+₹20.8 L (25.3%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹78.9 L
EMD Value
₹1.4 L
Closing Date
18 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER TUGHLAKABAD
HQ COMMANDER WORKS ENGINEER Air Force Station, Tughlakabad PO-Sangam Vihar New Delhi - 110080
PROVISION OF UG SUMPS AND ALLIED ITEMS/FACILITY FOR STORAGE AND SUPPLY OF WATER RECEIVED FROM GURGAON MUNICIPAL DEVELOPMENT AUTHORITY (GMDA) AT ASP UNDER GE(AF) GURGAON NO.1
2023_MES_594477_2
CWE/TKD/GUR/TOKEN-06 OF 2023-24
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE (AF) Gurgaon No.1
As per NIT conditions
8 documents required · 8 mandatory
₹1,000
GE (AF) GURGAON NO.1
₹1.4 L
Yes
30 Aug 2023
22 Jun 2023
20 Jul 2023
22 Jun 2023
18 Jul 2023
29 Jun 2023
Amount
Sch 'A' Part-I Bldg Work (B/R Work)
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal outside the MoD land complete all as specified and directed.
M&L cleaning and sterilization of inside of the RCC UG sump having capacity 50000.00 gallon through bacteriological treatment by using TERBAC G10, TERBAC 065/E-in-C's branch approved chemichal as recommended by Engr-in-charge including suitable steging/scafolding multi stage of cleaning are as under follows:- (a) First stage is to drain the water by using high capacity pump of dewatering system. (b) Second satge is cleaning all the stage formation inside the tank by using TERBAC G10 a laboratory tested branded chemical/ E-in-C's branch approved chemichal as recommended by Engr-in-charge (c) Third stage is scrubbing the walls and floor with mechnised scrubber and fresh water cleaning high speed jet pump (Rotary & Flat) to remove all scaling algae and formed perticles on internal surfaces of the tank completly. (d) Fourth stage (first bactria screening is sterilization by using TERBAC G 10, laboratory certified branded helogen compound E-in-C's branch approved chemichal as recommended by Engr-in-charge.
(e) Fifth stage is cleaning the floor of water tank by heavy duty industrial vacuum cleaners and sludge sucker having maximum 1200 watt with suitable heavy duty rugged motor to free any foreign and loose particles of any nature duty UV radiation which shall have 360 degree sterilization within the rank to kill all suspended bacteria (The radiation shall be portable and effective of drinking water tanks for dimension of floating and suspended bacteria) (f) Sixth stage is the second bacterial screening is sterilization by using ultra violet ray ejector covering 360 degree with in the tank and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilizes the floor, roof and wall of the water tank/UG sump by using laboratory certified branded strong oxidation agent TERBAC 65 of M/S Ray’s clean tech or equivalent any non toxic bio-degradable eco-friendly anti-bacterial agent.
Certified by a Govt. approved laboratory to disinfect the UG sump from all harmful pathogens. (h) Cleaning of external and internal surfaces, lid wall of the tank, structure free from all scales and other particles any algae, hives and any type of vegetation of any other unwanted matters, scrapping of old paint and painting with two coats of cement based water proof apex paint complete all as directed. (j) A Board of appropriate size and colour as directed by Engr-in-Charge and of non degradable materials with printed details as under:- (k) (i) CA No (ii) Name of Applicant (iii) Name of the contractor (iv) Columns for date of cleaning and expiry date will be written or painted on the sticker by permanent marking ink. (l) Testing of water sample of OHT/UG sump each before as well as after cleaning which before as well as after cleaning which is to be including of following tests: bacterial, biological, chemical and hardness test, through a NABL certified laboratory.
Note: (i) All required safety equipments (Gumboot, helmets, safety belts, safety fogless, torch light etc.) and necessary insurance for safety of working staff to execute the work is responsibility of the contractor. (i) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangement and the amount quoted for that is deemed to be inclusive in the unit rate and electricity/diesel shall not be provided by the MES. (iii) Contractor will not be allowed more than one day to do the work inside of the each OH Tank /UG Sump to prevent interruption of water supply to the users. (iv) Photographic evidence of all stage wise work shall be kept on record duly signed by Engineer-in-Charge and contractor. (v) Contractor shall submit all the purchase vouchers of chemicals used in this item before claiming of payment in RARs and final bill.
Material and labour for exposing the existing reinforcement bars fully in the repairs area and remove all loose scale and corrosion deposits and paint the exposed area of bar with anti rust paint and protective epoxy coating complete all as specified and directed. Note- The rate for Scaffolding and other tools deemed to be inclusive in the unit rate
M & L 15 mm thick rendering in CM (1:3) on vertical surfaces of brick walls finished even and smooth with using extra cement with water proofing compound mixing as per manufacturer instructions complete all as specified and directed. (WPC will be measured and paid separately)
Taking down cement plaster including raking out joints hacking for key and scrubbing down with water complete all as specified and directed.
M & L 15 mm thick rendering in CM (1:4) on vertical surfaces of brick walls or concrete surface finished even and smooth without using extra cement with using water proofing compound mixing as per manufacturer instructions complete all as specified and directed. (WPC will be measured and paid separately)
M & L 10 mm thick rendering in CM (1:3) on vertical surfaces of brick walls finished even and smooth without using extra cement complete all as specified and directed.
Supply of integral water proofing compound complete all as specified and directed.
M & L for rendering 5 mm thick on ceiling on fair faces of concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces and applying two coats of cement base paint over coat of chack primer on walls,facia and chajja complete all as specified and directed.
M & L preparation of new wood surfaces and applying two coats of sythetic enamel paint over a coat of wood primer complete all as specified and directed.
M & L preparation of new steel surfaces and applying two coats of sythetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coat of Oil Bound distemper of approved tint, over a coat of 3mm thick wall care putty complete all as specified and directed.
M&L for preparation of old plastered surface of ceiling and applying Two coat of white wash complete all as specified and directed.
M&L preparing old distempered surfaces of wall by complete removal of existing treatment and applying two coat of Oil emulsion distemper over 3mm thick wall putty complete all as specified and as directed.
M&L for preparation old treated surface by complete removal of existing treatment of wall and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each complete all as specified and as directed.
S& F Pressed door steel frames of size 165 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate hold fast, etc, (thickness of sheet shall be 1.25mm) and filling the pressed steel door frame with PCC 1:3:6 type C1 and making good the wall with plaster in CM 1:6 complete all as specified and as directed.
S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with if one face is covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.
Providing and fixing 150 mm long aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
S&F 200 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (Bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Providing and fixing 250 mm long aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and directed.
Supply and fix Solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet & edges will be painted to match with prelam sheet, reinforced with M.S. square tube and fixing in opening as per standard engineering practice complete all as specified and directed.
S & F for 30 mm thick factory made solid panel PVC door shutter confirming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications complete all as specified and directed.
Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches, pillars etc., complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks,straight or curved on plan exc 6m mean radius built in CM1:6 complete all as specified and directed
M&L Hard core of guage exc 63 mm but n.exc 100mm deposited spread and levelled in layers n.exc 15cm thick watered and rolled/ rammed to a true surfaces of broken stone boulders complete all as specified and directed.
M & L for 75 mm thick PCC 1:3:6 type C2 as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick,spread, levelled and rammed including watering well ramming complete all as specified and directed.
M&L for 25mm thick Cement Concrete type B-1, 1:2:4 (using 20mm graded crushed stone aggregate) for floor complete all as specified and as directed.
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to (Fe 410-W (Gde E-250) quality B) complete all as specified and as directed.
M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; will ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe410-0 or Fe 310-0 complete all as specified and as directed.
S & F Structural steel work with Fe-410-W(Gde-E-250) quality-A as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
M&L Cement concrete type B-0 1:2:4, (using 12.5mm graded crushed stone aggregate) , in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and as directed.
M&L for design mix concrete M-30 grade (using 20mm garded crushed stone aggregate), in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and as directed.
Dismantling existing water tanks Exc 250 ltr and nexc 500 ltr capacity and removing outside MoD land complete all as specified and as directed.
S & F ISI Marked 500 ltrs Rotational moulded polyethylene water storage tanks three layer (cylindrical vertical with closed top) hoisted and fixed in position including Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and Tank adaptor GI 20mm dia complete all as per specified and directed.
Taking down or up any size bore galvanised iron tubing and connection including cleaning for refixing or removal to store complete all as specified and directed.
S & F GI tubing 15 mm dia medium grade with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified and directed.
S & F GI tubing 20 mm dia medium grade with all fitting and fixed to walls & ceilings or laid in floors, complete all as specified and directed.
S & Fin repair vitreous China squatting pan of Orrissa pattern of approved make of size 630 mm X 450 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe incl cement concrete concrete bedding and connection to anti syphonage pipe etc including CI 'P' trap dia 100 mm complete all as specified .
S & F in repair 15 mm chromium plated cast copper alloy bib taps with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S & F in repair PVC low level flushing cistern of 10 ltr capacity inclusive of MS brackets of suitable size and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and as directed.
Dismantling floor hearth or wall tiles including cement mortar (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
S&F Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as dierected.
S&F Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) as in vertical surfaces area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, set and jointed in neat cement slurry and pointed in colour cement as in floor over and including 10mm rendering in cement mortar 1:4 complete all as specified and as dierected.
M & L Glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick over 10 mm thick plastering in CM 1:4 set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as dierected.
M&L for 25mm thick pre-painted chequered cement concrete tiles of size 20cmx20cm set and jointed in neat cement slurry with grey cement and pigment over and including 20mm thick screed bed in cement mortar 1:6 as in path, over & including 75mm thick Cement concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate) complete all as specified and directed. Note: The contractor shall submit test report of manufacturer for sample approval. The contractor shall produce purchase vouchers before claiming payment.
Removing existing roof treatment and preparing surfaces to the entire satisfaction of Engr-in Charge /GE including taking down existing plaster,cleaning of all foreign material such as grass roots dust etc and roughening the concrete surfaces by wire brushes and washing down to remove dust etc . flushing at junction of parapets complete and removing the same from MoD land complete all as specified and as directed. .
M&L 40 mm thick Cement concrete type B-0, 1:2:4 (using 12.50mm graded crushed stone aggregate) as in floor/Roof in proper slope including waterproofing compound including finshing cement concrete using extra cement complete all as specified and as directed..
M&L for Applying evenly a priming/tack coat with bituminous primer at 4 kg per 10 sq meters complete all as specified and as directed.
M & L for APP based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified and as directed.
M&L for preparation of surfaceand and applying two coat of Aluminium Paint over APP membrane , over 10cm in width or girth, not otherwise described complete all as specified and as directed.
Sch 'A' Part -II : Bldg Work (E/M Work)
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked concealed and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire complete all as specified and as directed. (The rate for works includes cutting and making good disturbed surfaces deemed to included in quated rate):
(a) One light point controlled by one way modular switch complete all as specified and directed.
(b) One ceiling/mounted fan point controlled by one way modular switch all as specified and directed.
(c) One exhaust/Ventilation fan point controlled by one way modular switch all as specified and directed.
(d) One 3 pin modular socket outlet 5 amps on the same board with the other switches, with cable 1.5 Sqmm size complete all as specified and directed.
(d) One 3 pin modular socket outlet 5 amps on independent board with the other switches, with cable 1.5 Sqmm size complete all as specified and directed.
All as per the item No 57 above but with copper conductor cable for 3pin socket outlet,15 Amps independent board with cable 4 sqmm size and 4 sqmm earth continuity conductor, complete all as specified and as directed.
M&L sub main wiring along with earth wire with the following sizes of 2x6 Sqmm and 1x6 Sqmm as earth continuity conductor and connected to earth dolly, PVC insulated single core multi stranded copper conductor cable drawn into and incl PVC conduit of adequate width and length with all accessories and fiiting like bends, elbow etc complete all as specified and directed.
Supply and fixing ceiling rose surface Bakelite 65 x 50mm, 3 terminal complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply & fix modular switch 1way 6A,1 module complete all as specified and as directed.
Supply & Fix modular Socket, 6A-2/3 Pin combined 2 module complete all as specified and as directed.
Supply & Fix modular switch socket combination outlet 3 pin, 5 Amp flash type complete all as specified as and directed.
Supply & fix switch socket combination 16A, 6Pin, 3Module independent complete all as specified and as directed.
Supply and fix modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
S&F Modular metal flush box 6 module complete all as specified and as directed.
S&F Modular metal flush box 4 module complete all as specified and as directed.
S&F White cover plate with frame, 4 module complete all as specified and as directed.
S&F White cover plate with frame, 6 module complete all as specified and as directed.
Supply and fixing 72W LED Street Light fully made of pressure die cast aluminium having rated efficacy at system level (not chip level) >120 lumens/Watt, life of fixture is not less than 50000 hrs @ L-70 lumen maintenance, CCT up to 5700K - 6500K, CRI minimum 70, PF >= 0.95, THD < 10% and an operating voltage range of 140 to 270V, internal surge protection > 4KV. The fixture should comply with the other parameters as per IS10322.. The Street light should be of Al pressure die cast construction & with PC Moulded LENS. The housing must be IP66 protected all as specified and directe.
Supply and fix sheet metal enclosures for double door DB's when MCBs to be used Single pole & neutral 06 way with 200 Amps rated bus bar complete all specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all specified and directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of SPN 40 to 63 Amp and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead with 4mm dia with protection pipe 15mm GI Light grade PIpe by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 3 including earth work funnel with watering arrangement, wire mesh, GI pipe 20mm internal dia light grade buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 and RCC chamber cover in 1:2:4 type B1 of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways wih MS Hooks of 10mm MS Bar including of returning, filling in and removal of surplus soil to a distance not exc 50 m as specified and directed by Engr-in-charge including testing on completion complete all as specified and as directed.. Note: The strip/wire upto 7.5mtr included in the quoted rate.
Sch 'A' Part -III: External Water Supply
M& L for making connection in water main supply line 600mm DI to 150mm DI using specials by manual and mechanical means as per site condition, lifting & shifting of items using crane, Dewatering by 5/10/20HP pumps, welding gas cutting concrete breaker and all other charges including GPRS survey before digging as per site condition complete in all respect with satisfaction complete all as specified and as directed.
M &L for fixing of 600mm MS clamp 10mm thick 600mm wide alongwith ferrule of size 150mm, rubber tyton ring of 150mm dia, 150mm DI pipe welded on clamp with flange of 150mm DI on one side complete in all respect as per specified and directed.
Supply , installation , testing and commisioning of flow meter with electromagenetic sensing head mounted on the end of support rod or fixed in-line electromagnetic having IP-68 class of protection for sensor +-0.5% error limit with 4G RTU with internet facility for real time data transmission to GMDA cloud server/ICCC including its online connection to BIS, CEI/IEC 61010-1:2001-2 with power backup of minimum 24 hrs so as to avoid loss of data transfer complete in all respect as per satisfaction complete all as specified and as directed. Make : ISOIL, Iotaflow,Adept and George Fischer
Supply installation, testing, commissioning of mechanical flow meter 150mm CI flanged type of reputed make conforming to ISO: 4064/1 specification complete and fixed in series with electromagnetic flow meter in connection line in all respect as per directed and specified .
Material and labour for lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron(DI) ISI marked K-9 grade,150mm(6") dia S&S pipes as per IS : 8329-2000(amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS :5382-1985(excluding special accessories) complete all as specified and directed.
Material and labour for lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron(DI) ISI marked K-9 grade,100mm(4") dia S&S pipes as per IS : 8329-2000(amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS :5382-1985(excluding special accessories) complete all as specified and directed.
M&L for fixing in position and jointing at all level/ depth DI Standard Specials plain/flanged/socketed confriming to IS -9523-2000 with rubber ring (EPDM/SBR) joints such asTee, bends,tapers, caps etc, within trenches in DI Pipe line of 150mm dia complete all as specified and directed.
M&L for fixing in position and jointing at all level/ depth DI Standard Specials plain/flanged/socketed confriming to IS -9523-2000 with rubber ring (EPDM/SBR) joints such asTee, bends,tapers, caps etc, within trenches in DI Pipe line of 100mm dia complete all as specified and directed.
M& L for road cutting for laying of pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified and directed .
Supply and fix Valves, Sluice, flanged of class 1.6 PN,150 mm (6”) dia Rising spindle type, Suitable for clear water upto 45° C and 5000 ppm turbidity other fluids with maximum pressure/Temperature conditions within the scope of IS:14846 complete all as specified and directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN,100 mm (4”) dia Rising spindle type, Suitable for clear water upto 45° C and 5000 ppm turbidity other fluids with maximum pressure/Temperature conditions within the scope of IS:14846 complete all as specified and directed.
S&F Air Release Valve Double Orifice Flanged IS14845 DK Type,PN1.6,Body & Cowl :Cast Iron,Balls :- Wood Seat ,Ring :-Nat Rubber of 100 mm (4") complete all as specified and directed.
Supply and fix Non Return Valves of class 1.6 PN,100 mm (4”) dia , Flanged Ends to IS 1538, Design Standard IS 5312 – 1, Seating design – Swing Type, Renewable Seat with Premium Quality Rubber Flap,Bolted Cover complete all as specified and directed.
Supply and fix Foot Valve Flanged end, swing type conforming to IS 4038, 150 mm (6”) dia complete all as specified and directed.
Supply and fix Strainer flanged Y type conforming to IS, size 150 mm (6”) dia complete all as specified and directed.
Supply and fix Strainer flanged Y type conforming to IS, size 100 mm (4”) dia complete all as specified and directed.
M&L for connection of DI Pipe in existing distribution system of 250/150/100mm Dia DI pipe including cutting, brazing and making flanged joint complete all as specified and directed.
Supply, installation and commissioning of 20 HP Monoblock centrifugal pumping set having brass impeller and CI motor body, 3000RPM speed , three Phase , operating voltage of 350-440, Freq-50Hz, head range: 17- 78mtr, having suction size: 100mm of electric driven all as specified and directed by Engr-in-Charge. Make: Crompton/KSB/Kirloskar Note : Foundation for installation of Pump is as per OEM of Pump instructions and is included in the quoted rate..
Excavating in trenches n exc. 1.5 m wide and n. exc 1.5 m in depth, foundation etc for shafts, well, cesspits , manholes, pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft soil complete all as specified and directed.
Material and labour for Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing excavated material n.exc 50 M and depositing where directed at a level n.exc 1.5 M above starting point complete all as specified and directed.
Material and labour for construction of brick masonary Valve chamber of size, 900mmx900mmx900mm(internal)suitable for housing sluice valve/gate valve etc with plain cement concrete 1:4:8 type D-2, using 40mm graded stone aggregates for foundation, 100mm thick with 150mm alround offset from external face of wall, brick work in cement motor 1:6, 230mm thick, rendering 15mm thick in cement motor1:4, inside complete and outside 150mm below ground level, coping with plain cement concrete 1:2:4 using 20mm graded stone aggregate, type B-1, including provision of MS Sheet cover 3.15mm thick fixed to MS angle iron frame 40x40x6mm embedded in PCC(1:2:4) concrete with suitable hinges and locking arrangements, including two coats of synthetic enamel paint over a coat of red oxide primer, including necessary excavation and earth work in any type of soil etc all as specified and directed.
Supply, Installation , Testing and Commissioning ultrasonic type water level sensor with 24 VDC 10amps Power supply for level sensor for enclosure for underground tank suitable for up to 6 meter water level depth of U/G sump, microprocessor based ultrasonic level transmitter capable of monitoring short or medium range of non-contact ultrasonic level measurements of liquids with one analog output (isolated 4-20mA), two digital control TTL output and RS485 MODBUS RTU communication protocol. the system must be with dead band of less than 0.6 meter, IP66 protection, accuracy of 0.25% of F.S. capable for working in ambient temperature of 0 degree centigrade to 75 degree centigrade, non- condensing at 25 degree centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50HZ power supply OLED display type vertical type mounting on top of OHTs the level sensor shall be shounted in a power coated MS enclosure with lockable front. Make: ITPC(IPCDLLMS)/KRATOS/US CampBell
Supply, Installation , Testing and Commissioning ultrasonic type water level sensor with 24 VDC 10amps Power supply for level sensor for enclosure for Over Head Tank having Process control remote display with Rs 485 MODBUS RTU Micro-controller based process control remote display (Display size 1.8") acts as controller cum process transmitter. the instrument with inputs like 0-20ma/4-20mA and it also has retransmission output 4-20 mA and 2 relay control relay and RS485 MODBUS RTU, Main (auxiliary supply) : 230vAC-50HZ, ndisplay value : -199to 9999, output (analog) : 4-20mA isolated (optical), control relay : one pair normally open potential free contact : @ 5Aat 240vAC, I/P : 0-20mA, operatng temp. : 0 dec. -50dec, overall size : 92x192x220 mm (HWD), panel cutout : 90x184mm (HxW). The process control display to be installed in a wall mounted enclosure of ABS/powder coated MS/polycarbonate. Make: ITPC(IPCDLLMS)/KRATOS/US CampBell
Supplying , installing , testing and commissioning High Pressure single head chemical dosing system. Power input 230V, 50hz, 40SPM, 1/30 fractional horse power, Pressure 5kg/Sqcm, Max output 6.5ltr/hr with accessories like lead tubing, connecting ferrule, check valves etc required for functioning of system alongwith the accessories mentioned complete all as specified and directed. Accessories:- 1) Preparation Tank of net capacity 170 ltrs FRP Dosing Tank dia 650 x net height 375 + conical 300mm, Gross height with stand 1000mm consisting of water inlet line, outlet with Y strainer, Drain, Overflow, Conical bottom of sludge deposition, pot hole with cover, level gauge. 2) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller; 3) Service tank of net capacity 100 ltrs of FRP dosing tank TOP dia 540mm x bottom dia 480mm x height 575mm consisting of water inlet line. Dosing pump inlet arrangement, Drain Overflow, Level Gauge, Inspection Port 4) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller.
Sch 'A'- Part-IV: External Electric Supply
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3½ core complete all as specified and directed.
Supply, laying & testing PVC Insulated and PVC Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Flexible Cables for Voltage Grade 1100 Volts conforming to IS: 694:2010 of size 3 Core, 4 Sq mm complete all as specified and directed
Excavating in trenches n exc. 1.5 m wide and n. exc 1.5 m in depth, foundation etc for shafts, well, cesspits , manholes, pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft soil complete all as specified and directed by Engineer-in-Charge.
Material and labour for Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material n.exc 50 M and depositing where directed at a level n.exc 1.5 M above starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed . Note : 18 cm thick only will be considered for payment purpose.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed.
Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. Shall be dust and vermin proof, protection class (IP-42) and made of 2.00 mm thick CRCA Sheet & suitable frame work/ support made out of 40 x 40 x 5 mm MS, front opening type with space for cable entry from back side of the panel, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. The scope of work also comprising of the following:-
The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-60439 withstand strenght should be 50kArms for 1.0 Sec with intial peak of 105kA 4. CPRI Certification IEC-60439 Rated current for short circuit not less than 4000 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED
S & F Earth continuity conductor or main earthing lead of for 32 x 6 mm dia galvanised iron fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. all as specified and directed by Engr-in-charge
Supply and fixing of GI pipe 40mm light Grade for LTCable in trenches for safety of cable complete or for earthing GI Strips 32 x 6 mm complete all as specified and directed.
M& L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip of 32 x 6 mm with GI Pipe 40mm Light grade for protection by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 3 including earth work funnel with watering arrangement, wire mesh, GI pipe 20mm internal dia light grade buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 and RCC chamber cover in 1:2:4 type B1 of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways wih MS Hooks of 10mm MS Bar including of returning, filling in and removal of surplus soil to a distance not exc 50 m as specified and directed by Engr-in-charge including testing on completion. Note: The strip/wire upto 7.5mtr included in the quoted rate.
Sch 'A' Part -V : Schedule of Credit
Saini Enterprises
J.P. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .