Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹28.0 L+₹45,641.10 (1.66%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 BID | |
| 3 | L3₹28.1 L+₹56,817.50 (2.07%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 BID | |
| 4 | L4₹28.8 L+₹1.3 L (4.81%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 BID | |
| 5 | L5₹31.6 L+₹4.1 L (14.9%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 BID |
| Sl No | Description | Qty | Unit | Srinivasa Consructions L10 | omsai thermax engineers L6 | L and S ENTERPRISES L7 | SUN LIGHT HOUSE L3 | MS ENTERPRISES L9 | Srinivash Engineers L2 | M/s. A&T Enterprises L8 | DPS sales and services india L11 | sree venkateswara enterprises L5 | SRI SAI RAM ENTERPRISES L4 | vvcenterprises L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair/ maintenance, excluding major spares but including regular maintenance of the Automatic Power factor correction panel capacity up to 100 KVARs and up 8 stages installed at various locations at garden cell area including carrying out complete maintenance/ repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/ MCCBs for isolation (with all the accessories) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/ new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. | 6 | EACH JOB | 2,300 ₹13,800 | 1,800 ₹10,800 Lowest | 6,300 ₹37,800 | 5,000 ₹30,000 | 1,867 ₹11,202 | 4,500 ₹27,000 | 7,020 ₹42,120 | 5,000 ₹30,000 | 12,500 ₹75,000 | 6,000 ₹36,000 | 2,500 ₹15,000 |
| 1.01Note for item No. 1.00 above:- (i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, replacement of defective control wiring, small part such as Push button, lugs any auxiliary contact, auto selector switch etc and necessary servicing repair by expert technician and register will be maintained for the same. (ii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, control CT, MCBs/ MCCB and fixing/ installing/ testing and commissioning the complete system. (iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/ MCCB shall be measured and paid separately | ||||||||||||||
| 2.00 | Supply only power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. | 7 | EACH | 1,250 ₹8,750 | 1,135 ₹7,945 | 1,260 ₹8,820 | 1,000 ₹7,000 Lowest | 2,877 ₹20,139 | 1,450 ₹10,150 | 1,320 ₹9,240 | 2,000 ₹14,000 | 10,000 ₹70,000 | 1,100 ₹7,700 | 1,200 ₹8,400 |
| 3.00 | All as per item No 2.00 above but 10 KVAR Capacitor Bank | 6 | EACH | 2,500 ₹15,000 | 2,250 ₹13,500 | 2,520 ₹15,120 | 2,000 ₹12,000 Lowest | 4,357 ₹26,142 | 2,200 ₹13,200 | 2,340 ₹14,040 | 3,500 ₹21,000 | 12,000 ₹72,000 | 2,100 ₹12,600 | 2,400 ₹14,400 |
| 4.00 | All as per item No 2.00 here-in-before but 15 KVAR Capacitor Bank | 5 | EACH | 3,750 ₹18,750 | 3,330 ₹16,650 Lowest | 5,040 ₹25,200 | 4,000 ₹20,000 | 5,647 ₹28,235 | 3,400 ₹17,000 | 4,545 ₹22,725 | 5,000 ₹25,000 | 13,000 ₹65,000 | 3,500 ₹17,500 | 3,500 ₹17,500 |
| 5.00 | All as per item No 2.00 here-in-before but 20 KVAR Capacitor Bank | 5 | EACH | 5,000 ₹25,000 | 4,500 ₹22,500 Lowest | 6,300 ₹31,500 | 5,000 ₹25,000 | 9,767 ₹48,835 | 4,500 ₹22,500 Lowest | 5,670 ₹28,350 | 6,500 ₹32,500 | 14,000 ₹70,000 | 4,500 ₹22,500 Lowest | 4,500 ₹22,500 Lowest |
| 6.00 | All as per item No 2.00 here-in-before but 25 KVAR Capacitor Bank | 3 | EACH | 6,250 ₹18,750 | 4,140 ₹12,420 | 1,710 ₹5,130 | 6,000 ₹18,000 | 11,227 ₹33,681 | 5,000 ₹15,000 | 1,530 ₹4,590 | 8,000 ₹24,000 | 14,500 ₹43,500 | 1,200 ₹3,600 Lowest | 5,500 ₹16,500 |
| 7.00 | S&F in replacement of old U/ s APFC relay etaCON M series with auto-set function 5 stage including taking down old unserviceable one complete all as specified and directed. | 2 | EACH | 12,000 ₹24,000 | 9,900 ₹19,800 | 13,500 ₹27,000 | 8,000 ₹16,000 | 8,667 ₹17,334 | 2,900 ₹5,800 Lowest | 12,600 ₹25,200 | 8,000 ₹16,000 | 4,500 ₹9,000 | 11,000 ₹22,000 | 10,500 ₹21,000 |
| 8.00 | All as per item No 7.00 here-in-before but APFC relay with auto-set function 7 stage | 2 | EACH | 13,000 ₹26,000 | 11,700 ₹23,400 | 14,400 ₹28,800 | 10,000 ₹20,000 | 9,987 ₹19,974 | 2,000 ₹4,000 Lowest | 13,500 ₹27,000 | 11,000 ₹22,000 | 5,000 ₹10,000 | 11,000 ₹22,000 | 13,500 ₹27,000 |
| 9.00 | All as per item No 7.00 here-in-before but APFC relay with auto-set function 8 stage | 2 | EACH | 15,000 ₹30,000 | 12,600 ₹25,200 | 14,400 ₹28,800 | 11,000 ₹22,000 | 11,227 ₹22,454 | 2,900 ₹5,800 Lowest | 13,500 ₹27,000 | 15,000 ₹30,000 | 6,000 ₹12,000 | 11,000 ₹22,000 | 18,500 ₹37,000 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jul 2025, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
REPAIR / RENEWAL OF CAPACITOR PANEL, CONTROL PANEL, CAPACITOR BANK, EARTHING LT PANEL, RELAY ASSOCIATED SWITCH GEAR AND ALLIED WORKS AT ZONE II B AND II C UNDER AGE EM II OF GE (U) SECUNDERABAD
2025_MES_718514_1
GE (U)/SEC/TOKEN/23 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
All as per Tender Documents
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹80,000
Yes
6 Oct 2025
4 Jul 2025
1 Aug 2025
4 Jul 2025
25 Jul 2025
18 Jul 2025
Amount
Repair/ maintenance, excluding major spares but including regular maintenance of the Automatic Power factor correction panel capacity up to 100 KVARs and up 8 stages installed at various locations at garden cell area including carrying out complete maintenance/ repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/ MCCBs for isolation (with all the accessories) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/ new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed.
Supply only power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed.
All as per item No 2.00 above but 10 KVAR Capacitor Bank
All as per item No 2.00 here-in-before but 15 KVAR Capacitor Bank
All as per item No 2.00 here-in-before but 20 KVAR Capacitor Bank
All as per item No 2.00 here-in-before but 25 KVAR Capacitor Bank
S&F in replacement of old U/ s APFC relay etaCON M series with auto-set function 5 stage including taking down old unserviceable one complete all as specified and directed.
All as per item No 7.00 here-in-before but APFC relay with auto-set function 7 stage
All as per item No 7.00 here-in-before but APFC relay with auto-set function 8 stage
Supply and fixing in replacement steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified.
S&F in replacement PVC insulated unsheathed/ sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/ 1990 with latest amendments ISI including disconnecting/ taking out existing unsv/ damaged old service cable complete all as specified and directed.
All as per item No 11.00 above but of size 6 Sqmm complete all as specified and directed.
S&F in replacement hot press moulded SMC junction/ terminal box of size with internal dimensions of 300 x 200 x 1055 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed.
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/ drain/ floor/ pole including necessary clamps 40x4mm all as specified and directed by Engr-in-Charge.
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and directed by Engr-in-Charge.
Supply and laying GI tubing light grade of size 80 mm for cable protection on road/ drain/ floor/ pole including necessary clamps all as specified and directed by Engr-in-Charge.
S&F in replacement LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F in replacement LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F in replacement LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm.
S&F in replacement Off-Load changeover switch along with sheet steel enclosure, AC 21 (Side Handle), 4 pole of capacity 400 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
S&F in replacement Off-Load changeover switch along with sheet steel enclosure, AC 21 (Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
S&F in replacement Off-Load changeover switch along with sheet steel enclosure, AC 23 (Side Handle), 4 pole of capacity 100 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
S&F in replacement Off-Load changeover switch along with sheet steel enclosure, AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed.
Supply only of aluminium cable lugs of following sizes :-
16 to 25 Sqmm Size
35 to 50 Sqmm Size
70 to 95 Sqmm Size
120 to 150 Sqmm Size
185 to 240 Sqmm Size.
S&F in replacement MCCB box FACTORY FABRICATED Powder coated Suitable for fixing at WALL including two set of clamps comprising with the following i) MCCB 63 Amps 25 KA FP WITH BOTH SIDE SPREADER LINK all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB box FACTORY FABRICATED Powder coated Suitable for fixing at WALL including two set of clamps comprising with the following i) MCCB 100 Amps 25 KA FP WITH BOTH SIDE SPREADER LINK all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB box FACTORY FABRICATED Powder coated Suitable for fixing at WALL including two set of clamps comprising with the following i) MCCB 125 Amps 25 KA FP WITH BOTH SIDE SPREADER LINK all as specified and directed by Engr-in-Charge.
Supply and fix on wall with necessary arrangements busbar chamber 100 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powder coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
Supply and fix on wall with necessary arrangements busbar chamber 200 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powder coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
Dismantling of damage / broken coping of PCC/ steel pole of any size and and removing the debris from site complete all as specified and directed
Supply and fixing in replacement lantern of dia 60cm for fixing of flood light, cap type to be fixed on the top of 9m SP-31/ 11m SP-55 steel pole, made of MS pipe medium grade dia greater than the top dia of the pole of length 0.35M supported by MS flat iron of size 50 X 6mm- 8Nos including two coat of aluminium painting over a coat of red oxide primer complete all as directed.
Dismantling LT steel tubular pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Supply and fix locally available gate / garden light best quality metal Silver / metal black Decorative Exterior of size not less than 300 mm X220 mm with and including LED bulb 9 watt suitable for outdoor installation and suitable for fixing in 40/ 50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Supply and fix locally available gate / garden light best quality Black Colour steel shade with fiber glass outdoor Gate lamp of size not less than 360mm X 250mm with and including LED bulb 9 watt suitable for outdoor installation and suitable for fixing in 40/ 50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Material and labour for Taking down UNSV LED Lights and removing Carbon from its connector joints incl replacement of Connecting wire with new PVC sheathed weatherproof single core cable for electrical connection and refixing the fitting after repair to its original/ New location or as directed by Engr-in-charge.(connecting wire will be measured and paid separately only)
Supply and fix locally available Acrylic glob light best quality clear with and including LED bulb 9 watt of 200 mm dia complete suitable for fixing in 40/ 50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Supply and fix locally available Acrylic glob light best quality clear with and including LED bulb 9 watt of 300 mm dia complete suitable for fixing in 40/ 50 mm dia GI pipe including necessary connections complete all as specified and directed including taking down old one .
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 1.50 sq mm including 20mm dia HDPE pipe conduit of dia 20 mm medium grade exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including HDPE pipe 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings. (USED FOR GARDEN LIGHT CONNECTION, EXCAVATION , RETUNING FILLIING ETC WILL BE MEASURED AND PAID SEPARATELY.
Supply, fixing, connecting and testing decorative LED Bollard light with opal diffuser and aluminium reflector of 9/ 12 watt LED including nut, bolts, washers, clamps etc as in repair complete all as specified and directed.
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 1.5 sqmm as required for connection of light fittings .
Excavation in post holes (or similar holes) each n exc 0.50 cum getting out In hard / dense soil returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm complete all as specified and directed
M&L for framed works in posts and struts in fencing including cutting tops to shape as directed drilling holes notching for wire etc flat iron fillets ( for securing wire mesh etc ) including all necessary drilling bolting or riveting etc and similar work conforming to FE-290 Gde E-165 including dismantling of old fencing complete all as specified and directed.
M&L for cleaning AND painting LT panel boards of any size thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt / rust carefully and applying two coats of synthetic enamel paint OVER A COAR OD RED OXIDE PRIMER COMPLETE all as specified and directed.
Supply, Installation, test and Commissioning factory fabricated, outdoor type, LT FEEDER PILLAR BOX made out of 3.15 mm thick CRCA Sheet of with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, , suitable for 440 Volt 3 Phase 4 Wire System , including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete with internal connection with suitable size of cable , cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 400amps - 04 Nos, in 3 phase and half neutral fashion supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. (b) MCCB 200 amps, 415 volt, 16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar as IN COMING - 01 Nos
M&L in replacement of Multi function energy meter with Supply, Test and commissioning of 3 Phase 4 wire Maximum demand controller of accuracy class 0.5 suitable to monitor, recording and controlling of Maximum demand including provision for fixing in existing enclosure or by provision of suitable enclosure complete all as specified and as directed. The MD Controller shall be equipped with following features:- Monitoring - Max demand profile during a billing cycle. Demand peaks with date & time can be identified in the meter . The events can be studied and related with the min/ max load events such as starting of Large pumps/ AC Plants etc., and helps to decide on switching/ staggering of loads etc. Control - MD Controller should enables user to program the threshold values of max demand and initiate ALARM/ CUT-OFF when the Forecast Demand/ Present Demand/ Max Demand surpasses the threshold values, so ad to enable the system from not exceeding the sanctioned demand and avoid causing a trip or paying huge penalty.
Item No. 48.00 Contd... Additional Load - Shall be able to decide to transfer the exact quantum of load from EB to DG or vice versa for economic power. High Low Event Recording for V, A, Hz, VA, W, VAr, PF Protection of 3 phase system against single phasing, low & high voltage, over load, highly lagging and leading PF, Hz etc. Navigator can trap such events for future reference. Identify, record unbalance voltage, currents and helps the user to identify the root cause. Unbalance over-burdens the electrical system and affects in the form of over loading of cables, motors and switchgear. PF Management : Lower the Avg PF higher the system inefficiency. The Digital output features shall initiate alarm when the Avg PF crosses the user programmed threshold values (Lead/ Lag). Switch Gear (ACB or MCCB) required Shunt trip coil (230VAC) to trip the same when demand crossed the thresh hold value. Note: Rates for Provision & fixing in the existing panel/ with suitable enclosure is deemed to be included in the quoted rates. No extra payment will be done on this account. Make : Elmeausre/ L&T or equivalent.
M&L for control wiring including defining logic for MD Controller for Item No 89 above from Switchgear Relaying/ Trip circuit with suitable interposing relay or trip contacts with suitable size of multi core copper control wiring to monitor, alert, controlling MD by provision of hooter for alerting the duty operator in case of exceeding MD for the designed threshold values. Note: 1. Contractor should inspect the site before quoting the tender. Control wiring system any No of runs and Length suitable for MD controller shall be done by the Rep of OEM of MD Controller and shall study the loading pattern and design the control system complete including the features of controller. After finishing the job OEM rep shall submit the test report by mentioning all set parameters. Note 2: Any defect/ damage to the MD controller shall be attended in 24 hrs till DLP. Failing the penalty/ excess demand charges if any paid by department to TSEB shall be reimbursed by the contractor.
S&F in replacement in replacement florescent tape of yellow/ red colour around the LT/ HT pole along the road side
M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose.
Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.
Taking down old unsv Street light / flood light fittings in any position of any capacity for Repair by replacement of unsv spares ( SPD / Driver / Mcpcb etc ) and re-fixing the same in existing location. Note:- Spares for repair of street light fittings will be measured and paid under respective items.
Notes for Item Nos 51.01 to 51.03 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/ her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabad and the same shall be submitted to E/M No II store on daily basis.
M&L in replacement for ACSR conductor, steel reinforced for LT over head lines on poles including stretching tightening of poles insulator with binding wire of suitable size with insulator/ stretching of ACSR conductor including disconnecting/ taking out old existing unsv ACSR conductors complete all as specified and directed.
M&L in replacement for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed.
M&L in replacement for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/ taking out old existing unsv insulators complete all as specified and directed.
S&F in replacement in replacement Stay assembly comprising of 7/ 10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/ mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/ bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, up to 50m including disconnecting/ taking out old existing unsv stay assembly complete all as specified and directed.
S&F in replacement in replacement of Galvanised steel wire (GI) 4mm dia including disconnecting/ taking out old existing unsv GI wire complete all as specified and directed.
M/ L in replacement for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/ taking out old existing unsv cross arms complete all as specified and directed.
Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/ IS:13947-II) in existing LT Panel box/ Feeder Pillar boxes (KIOSK), in MCCB DBs of capacity 630 Amps, 4 Pole, 36 KA, 415 Volt including disconnecting/ taking out existing old unsv/ burned MCCB complete all as specified and directed.
All as per item No 58.00 here in before but of capacity 315-400 Amps, 4 pole, 35 KA
All as per item No 58.00 here in before but of capacity 250 Amps, 4 pole, 25 KA
All as per item No 58.00 here in before but of capacity 200 Amps, 4 pole, 25 KA
All as per item No 58.00 here in before but of capacity 160 Amps, 4 pole, 16KA
All as per item No 58.00 here in before but of capacity 125 Amps, 4 pole, 16 KA
All as per item No 58.00 here in before but of capacity 100 Amps, 4 pole, 16 KA
All as per item No 58.00 here in before but of capacity 63 Amps, 4 pole, 16 KA
Supply and replace contactor single pole 20/ 25/ 32 amps in street light timer box coil operating voltage 230 volt complete all as specified and directed .
Supply and replace contactor single pole 40/ 63 amps in street light timer box coil operating voltage 230 volt complete all as specified and directed .
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LT UG cable of size 50 Sqmm, 3.5 Core complete all as specified and directed.
All as per item No 70.00 above but suitable for aluminium conductor cable of size of 95 Sqmm, 3.5 Core
All as per item No 70.00 above but suitable for aluminium conductor cable of size of 120 sqmm, 3.5 Core
All as per item No 70.00 above but suitable for aluminium conductor cable of size of 240 Sqmm, 3.5 Core
Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and directed.
All as per item No 74.00 above but suitable for aluminium conductor cable of size of 95 Sqmm, 3.5 Core
All as per item No 74.00 above but suitable for aluminium conductor cable of size of 120 sqmm, 3.5 Core
All as per item No 74.00 above but suitable for aluminium conductor cable of size of 240 Sqmm, 3.5 Core
Supply and lay in trenches/ fixed to walls/ poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item No 78.00 above but 2 Core 10 Sqmm
All as per item No 78.00 above but 4 Core 16 Sqmm
All as per item No 78.00 above but 4.0 Core 25 Sqmm
All as per item No 78.00 above but 3.5 Core 35 Sqmm
All as per item No 78.00 above but 3.5 Core 50 Sqmm
All as per item No 78.00 above but 3.5 Core 70 Sqmm
All as per item No 78.00 above but 3.5 Core 95 Sqmm
All as per item No 78.00 above but 3.5 Core 120 Sqmm
All as per item No 78.00 above but 3.5 Core 150 Sqmm
All as per item No 78.00 above but 3.5 Core 185 Sqmm
All as per item No 78.00 above but 3.5 Core 240 Sqmm
All as per item No 78.00 above but 3.5 Core 300 Sqmm
Taking out and Relaying of LT cable of size 10sq mm to 50 Sqmm 2/ 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevant Item)
Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevant Item)
Taking out and Relaying of LT cable of size 185 sq mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by Engr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevant Item)
Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) ( in replacement of steel/ PCC pole ) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Restreching/ Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and pruning of tree complete all as specified and directed. Notes: (i) The distance between pole to pole in one span (contains 2/ 4/ 6 runs) i.e. one span will only be considered for payment purpose. (ii) No Extra conductor will be measured for binding to insulators / jumpering etc.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/ Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
All as per item No 96.00 above but depth exc 1.5 mtr but not exc 3 mtr.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Spreading riddled earth (after preparation of excavated earth) in Cable duct for cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness 18 CM (6.25 Cm below cable and 11.75 cm above cable) will be measured for payment purpose. The earth removed during excavation to be used as riddled earth after crushing and sieving. Quoted rate inclusive of all arrangement as mentioned.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 210 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before), complete all as directed.
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all as specified and directed by Engr-in-Charge.
M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed
M&L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed
Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
M&L for road crossing/ drain crossing by adopting trench less tunnelling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunnelling, excavation in any type of soils including hard rock, HDPE / GI pipe medium duty of size 100 mm dia in any length including jointing materials to carry LT UG cables of size up to 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities complete all as specified and as directed. NOTE ; PIPE WILL BE MEASURED AND PAID SEPARATELY UNDER RELIVENT ITEMS
M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate, 20mm thick and earth pit cover made out of RCC 1:2:4 type B1 cover reinforced with 8mm dia MS deformed bars @ 100mm centre to centre both ways with hook made out of 8mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M&L repair/ maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed.
M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including thoroughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamel base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia) and two meter length, The electrode should be of galvanised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Crystalline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg Backfill compound to provide maximum contact between the electrode and Back Fill Compound. The earthing pit cover should be factory built ( size TOP- 10 Inch, Bottom -13 Inch, Height 10.25 Inch ) made of heavy duty Polypropylene complete all as specified and directed.
S&F in replacement galvanised steel strip 32X6 mm with saddles and fixing screws on porcelain insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/ wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Trimming/ pruning and removing of tree branches or any other foreign objects from HT/ LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way / 4 way/ 6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job.
Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/ around 2/ 4 Pole structure/ along the boundary fencing and removing rubbish from the site of work complete all as specified and directed.
S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete, lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, fixing to wall/ pole, complete all as specified and directed.
All as per item No 117.00 above but 70/ 72 watts.
All as per item No 117.00 above but 60 watts.
S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 120 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/ pole complete all as specified and directed.
All as per item No 120.00 above but 120 watt.
All as per item No 120.00 above but 150 watts.
All as per item No 120.00 above but 200 watts.
Srinivash Engineers (BID ID -3363874)
SUN LIGHT HOUSE (BID ID -3371614)
SRI SAI RAM ENTERPRISES (BID ID -3370733)
sree venkateswara enterprises (BID ID -3369293)
omsai thermax engineers (BID ID -3371102)
L and S ENTERPRISES (BID ID -3371508)
M/s. A&T Enterprises (BID ID -3370637)
MS ENTERPRISES (BID ID -3371678)
Srinivasa Consructions (BID ID -3370616)
DPS sales and services india (BID ID -3370212)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .