Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹40.7 L+₹3.9 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Being Higher Bidder | |
| 3 | L3₹44.9 L+₹8.1 L (21.9%)Rejected-Finance RAJEEV NAGAR KUTIA GHUSIYANA KHARIKA TELIBAGH LUCKNOW | LUCKNOW | LUCKNOW | UTTAR PRADESH | L3 | Rejected-Finance Being Higher Bidder |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
23 Mar 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF LT RING MAIN BY PROVIDING LT UG CABLE AND CONNECTED ITEMS AT KB ROAD AND HM MARG, 01 X LADY TOILET/WASHROOM IN OFFICE COMPLEX OF AGE E/M EXT (ELECT) AND RETROFIT EMISSION CONTROL DEVICE (RECD) FOR 01X125 KVA DG SET UNDER GE E/M LUCKNOW
2023_MES_580378_2
GE/EM/LKO/EXT(ELECT)/T-70 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹86,000
Yes
30 Mar 2023
2 Mar 2023
25 Mar 2023
2 Mar 2023
23 Mar 2023
6 Mar 2023
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil, complete all as specified and directed.
All as per item No 2 above but exceeding 1.5m but not exceeding 3 m in depth for foundation and getting out in soft/loose soil.
Returning filling in including spreading levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundation /sub base of floor, filling and mass concrete, complete all as specified and directed.
S&F Mild stee bars (TMT bars) 10 mm dia and over as in reinforcement cut to length, bent to shape required including cranking hooking ends and binding with mild steel wire [annealed] not less than 0.9 mm dia or scruing with clips, complete all as specified and directed.
All as per item No 7 above but 8mm dia
All as per item No 7 above but 8 to 10mm dia in stirrups
M&L for RCC M-25 using 20 mm graded stone aggregate as in foundation, plinth beam etc complete all as specified and directed.
M&L for RCC M-25 using 20 mm graded stone aggregate as in roof slab, shelves, balcony etc complete all as specified and directed.
M&L for RCC M-25 using 20 mm graded stone aggregate as in beams, cantilevers, lintel over 1.5m span etc complete all as specified and directed.
M&L for RCC M-25 using 20 mm graded stone aggregate as in chajjas etc complete all as specified and directed.
M&L for RCC M-25 using 20 mm graded stone aggregate as in columns, pillars, piers etc complete all as specified and directed.
M&L for brick work with fly ash bricks as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L for brick work with fly ash bricks as per IS 12894 -2002 straight or curved on plan exc 6 m mean radius in half brick work built in cement mortar 1:4, complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work/ concrete surfaces in cement mortar 1:6 finished fair, even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of concrete surfaces as in ceiling in cement mortar 1:3 finished fair, even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on fair faces of concrete surfaces as in cement mortar 1:3 finished fair, even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in two layers, 10mm as rendering coat and 5mm as setting coat with water proofing compound on brick work/ concrete on fair surfaces surfaces in cement mortar 1:4, finishing the surface fair, even and smooth without using extra cement complete all as specified and directed.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth on wall/ceiling surfaces, complete all as specified and directed.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work over wall/ceiling surfaces, complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
M&L for formwork to soffits of suspended slabs, such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick [Horizontal or sloping] for rough finished flat faces complete all as specified and directed.
M&L for formwork to sides of pillars, posts, piers and columns (polygonal/ circular) for fair finished flat surfaces etc complete all as specified and directed.
M&L for formwork to sides & soffits floor or roof beam for fair finished flat surfaces etc complete all as specified and directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc flat rough finished surface complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas & similar items for rough finished flat surfaces etc complete all as specified and directed.
M&L for broken bricks for hardcore of gauge nexc 63 mm, deposited, spread and levelled in layers nexc 15 cm thick watered and rammed to true surface, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floor, complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 typeC-2 (using 40 mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement, complete all as specified and directed.
S&F tubes 15 mm bore "medium grade" with and including fittings & fixed complete to wall and ceilings or laid in floor complete all as specified and directed.
S&F tubes 20 mm bore "medium grade" with and including fittings & fixed complete to wall and ceilings or laid in floor complete all as specified and directed.
S&F tubes 20 mm bore "medium grade" with and including fittings & fixed complete to wall and ceilings or laid in floor including taking down complete all as specified and directed.
M & L for 40mm bore Tubes, 'medium grade' galvanised, with and including fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
M&L for joint free Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 x 300 x 7 mm [thick] set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 10mm thick rendering in CM 1:3, complete all as specified and directed.
M&L 15mm thick screed plaster on RCC slab in CM 1:4 using water proofing compound @ 3% by weight of cement or as per manufacturer instruction, complete all as specified and directed.
Supply only integral water proofing compound powder conforming to IS specification, complete all as specified and directed.
M&L for water proofing treatment on roof surfaces in the following manner:- (a) The surfaces shall be painted with hot bitumen grade 30/40 confirming to IS-73 @ 1.20 kg/sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 litr/sqm (b) Supply & laying 3mm thick APP water proofing membrane reinforced with non woven polyster matt laid using butane torch by torch on application with a side lap of 10cm & 15cm end lap weinghing not less than 3 kg/sqm including two coat of aluminium paint on top surface
M&L applying one coat of aluminium paints over new or previously untreated steel surface of any description, over 10cm in width or girth,not otherwise described including preparation complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt I. capacity of tank 500 litres complete all as specified and directed.
S&F Ball brass valves, high pressure, with polythene float & steel rod & fly nut complete, screwed for iron pipe or brass ferrule and fixed 20 mm bore pipe, complete all as specified and directed.
S & F 20mm dia gun metal or gate valve with ironwheel head screwed both for iron pipe and fixed, complete all as specified and directed.
S&F vitreous china Europeon Water Closet (one piece) of specified make with flushing cistern & white seat cover complete all as specified and directed.
S&F for CP angle cock (two way) complete all as specified and directed.
S&F for health faucet, chromium plated rising spray with wall brackets with 1.5m long metallic flexible tube with 15 mm dia fixed in repair complete all as specified and directed.
S&F for Automatic Soap dispensor complete all as specified and directed.
S&F white Toilet paper holder of stainless steel (specified make) fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S & F PVC connection 15mm size with PTMT nut of length 450mm, complete all as specified and directed.
S & F stop cock one way (Angle valve) 15mm dia chromium plated cast copper alloy screw down pipe pressure with crutch or butterfly handle scrwed both ends for iron pipe or union, complete all as specified and directed.
M & L for Thin rim table top basin, Shape- rectangular of size 485mm x 395mmx150 mm with complete necessary fixing arrangements. The basin shall be provided on granite slab, complete all as specified and directed. (Note :- Granite slab will be measured and paid seperately)
S & F 15mm dia pillar taps fancy type cast copper alloy chromium plated ,screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts screwed for iron pipe (bore of pipe 15mm), complete all as specified and directed.
S & F 100 mm dia grating doom of PTMT (min weight 20 gm each), complete all as specified and directed.
S&F looking mirror 600x450 mm consisting of 4 mm thick glass mounted on 4 mm thick plywood and providing decorative type wooden beading with varnish finish complete all as specified and directed.
S & F chromium plated soap tray fixed with rawl plugs complete all as specified and directed.
S& F for Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
S& F Brass Chromium plated shower roses 125mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F bib taps for 15 mm bore pipe cast copper alloy chromium plated fancy type with crutch or butterfly handle,screwed down, screwed for iron pipe and fixed, complete all as specified and directed.
S &F 110mm bore (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or in floors/fix to wall, complete all as specified and directed.
All as per item No 60 above but dia of 75mm
M&L (SWR) 75mm dia floor trap plain with grating including jointing with solvent cement, complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (single Tee) equal or unequal with access door, complete all as specified and directed.
All as per item No 63 above but dia of 75mm
S &F 110mm bore (SWR) pipe single socketed in any length with rubber ring joints,fixed to walls, complete all as specified and directed.
All as per item No 65 above but dia of 75mm
S&F 110mm bore PVC (SWR) vent cowl, complete all as specified and directed.
S&F 110mm bore PVC (SWR) bend of any radius, complete all as specified and directed.
All as per item No 68 above but dia of 75mm
S&F in PVC (SWR) 125/110 mm gully trap with grating including jointing with solvent cement, complete all as specified and directed.
M&L for 40mm thick DPC using PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate with Liquid water proofing compound including mixed 3% by weight of cement or as per manufacturer instruction necessary formwork, complete all as specified and directed.
M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, shelves, parapet etc including necessary form work complete all as specified and directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for two coats of synthetic enamel paint over red oxide primer coating including preparation of newly steel surfaces of any description, not otherwise described, over 10cm width or girth etc complete all as specified and directed.
M & L for 32mm dia Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed.
S & F for powder coated aluminium extruded sections (conforming to IS) (minimum thickness of powder coating 50 micron) three track sliding window shutter with frames comprising series-C (20mm) , duly fitted with neoprene beading, glazing clipss, locking devices, heat absorbing glass 4.8mm thickness (in 2 shutters) and with SS wire cloth of 0.46mm nominal dia of wire and average width of aperature 1.4mm (in one shutter) complete all as specified and directed.
M&L for powder coated aluminium ventilator fixed with refletive type glass, aluminium section weighting 0.55 kg/m including necessary joining cleats, glazing clips rubber neospeprene at bottom panel and top panel with wire cloth of 0.46mm nominal dia of wire and average with of aperature 1.4mm complete all as specified and directed.
M& L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed.
S&F for chromium plated long body mounted type pillar tap complete all as specified and directed.
M & L for Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc, complete all as specified and directed.
S & F for Sheet glass, 4.8mm thick ordinary quality frosted on one side and glazing fixed in wall with SS screw of any shape and size exc 0.5 sq. m in each complete all as specified and directed.
M&L for precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in manhole covers set in CM (1:4) with plain and fair faces of slab including necessary form work (Note: Reinforement slabs be measured and paid for separately), complete all as specified and directed.
M&L for sand cusioning bed to double wall black coloured corrugated HDPE pipe including paking under and sides of pipe after they are laid in slope and tested sewer pipe line complete all as specified and directed.
Providing supplying and laying of class SN8 structured all polyethelen piping systems (Pipe ith online/ofline couple and elatomeric ealing ring) with non smooth exterrnal Annular corruqated and smooth internal surface (Double wall) for non pressure undergroud sewerage & Drainage application conforming to IS:16098:2013 including all materials, labours T&P required for proper completion of work for sewer network, complete all as specified and directed (To collection of sewage) (a) 150 mm internal diameter pipe
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet rainforced with MS squire tube in opening all as per site requirement, complete all as specified and directed.
S&F factory made solid PVC molded door shutter, 28 to 30mm thick (Stiles), with 2,4, or 6 raised panel design with 2 mm thick moulded PVC sheeet on the front face & 2mm plain colour PVC sheet on back face with particle board core all as per site reqirement, complete all as specified and directed.
S&F brass barrel tower bolts with cast bolts and fixed 1.50 mm length, complete all as specified and directed.
S&F aluminium alloy, anodised sliding door bolts with hasp, stapple (bolt type) and fixing clips of seat, cast or extruded sections and fixing bolts and sliding bolts of extruded sections are cast allum alloy and fixed of 150mm length, complete all as specified and directed.
S&F butt hinges 100 mm length med weight, cold rolled miled steel and fixed all as per site requirement, complete all as specified and directed.
M & L for One light/fan/ bell point controlled by one, one way switch concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed.
All as per item No 90 above but One 3 pin 5 Amp socket outlet on the same board with other switches.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and directed.
S&F switch socket 6A - 2/3 pin combined piano type, complete all as specified and directed.
S&F Lamp holder insulated body with back plate for batten fitting complete all as specified and directed.
M&L Ceiling rose surface bakelite 65x50mm, three terminals complete all as specified and directed.
M&L for Sub main wiring with two runs of 10 Sqmm single core FRLS PVC insulated but in unsheathed multi stranded copper conductor cable 1100 volts grade drawn through and including of 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 6.0 Sqmm PVC insulated copper conductor earth continuity wire complete all as specified and directed.
S&F Factory made, sheet metal distribution boards, double door protection class IP-42 suitable for mounting MCB/ MCCB, confirming to IS-13032, IS-8623, BS-5484 r of the SP&SPN 4 ways complete all as specified and directed.
S&F MCB 10 KA confirming to IS-8828 : 1996, IEC-898 : 1995 rupturing capacity of the under mentioned type and rating SP 5 to 32 Amps, complete all as specified and directed.
S&F MCB 10 KA confirming to IS-8828 : 1996, IEC-898 : 1995 rupturing capacity of the under mentioned type and rating SPN 32 to 63 Amps, complete all as specified and directed.
M&L Earthing complete with galvanized steel plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground earth pit not less than 2.25 meter deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanized wire 25x 4 mm GI strip by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 15mm dia GI light grade protection pipe from test point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame with louvers, complete all as specified and directed.
Supply and Fix LED lamp 10 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) including dismentling taking out unsv CFL/LED Bulb, complete all as specified and directed.
S&F Bronze gate valve for 20 mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778 : 1984, fixed as in repair including dismentling taking down old unserviceable one complete all as specified and directed.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
M&L laying well burnt brick work with fly ash bricks as per IS 12894-2002, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified and directed.
M&L for demolition /cutting of road/ path/hardstading/ concrete in floor, etc for laying of cable complete all as specified and directed.
Material and labour for PCC 1:2:4 type B-2 using 40 mm graded stone aggregates for filling of cutting of roads/path/hardstanding etc complete all as specified and directed.
Boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 80 mm bore and making good both ends complete all as specified and directed.
Supplying and Fixing Mild steel galvanized tubes light grade ISI marked 80 mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain/floor etc complete all as specified and directed.
Supplying and laying or fixing, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade, cross sectional area 185 Sqmm , 3.5 core complete all as specified laid in trenches/ laid under floor or fixed naked with walls/ on poles/ in ducts /in GI pipes etc. with and including MS clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under resective items of schedule
Supply, installing, testing and commissioning factory made , tested , CPRI approved powder coated LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 50x50x6mm thick MS angle iron frame work, the cubical have bottom channel of size 75x40mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :- (a) Incoming :- (i) On load change over switch open execution type , 400 Amps , 4 pole , 415 volt , 50 Hz-01 No (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
All as per item No 111 above but comprising with following:- (a) Incoming :- (i) On load change over switch open execution type , 630 Amps , 4 pole , 415 volt , 50 Hz-01 No (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 600/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 1200 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion, complete all as specified and directed.
M&L horizontal boring and inserting casing pipe with fittings with material HDPE of pressure rating 6 kg/cm² along road and under pavements/ hard standing/ road /canals /streams crossing in all types of soil at prescribed depth (in no case the depth of boring be less than 1.7 m from the road surface) up to 200 meters of drilling longitudinal or 3 to 4 roads crossing should be possible, for passing of LT cable of size 185 sqmm including all civil works & reinstatement as per BMP standards complete all as specified and directed. Note : if any damages to existing services such as OFC/gas pipe line/electric cable etc shall be repaired immediatelly by the contactor. Rate quoted above deemed to be includinguded.
Supplying, installation, commissioning and testing of Retrofit Emission Control Device (RECD) of 125 KVA Diesel Generator Set of Make - Crompton Greaves/Kisloskar/Cummins/Catterpillar. The device should have approval of one of the five CPCB recoginsed labs complete all as specified and directed.
VIDYA TRADERS
NAVJYOTI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .