Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPT | |
| 2 | L2₹23.6 L+₹72,651.50 (3.18%)Rejected-AOC | L2 | Rejected-AOC REJECT | |
| 3 | L3₹23.9 L+₹1.0 L (4.43%)Rejected-AOC | L3 | Rejected-AOC REJECT | |
| 4 | L4₹24.0 L+₹1.1 L (4.99%)Rejected-AOC COIMBATORE | L4 | Rejected-AOC REJECT | |
| 5 | L5₹24.7 L+₹1.9 L (8.10%)Rejected-AOC PASUMALAITHANGAL GINGEE VILUPPURAM | L5 | Rejected-AOC REJECT |
Tender Value
₹30 L
EMD Value
₹30,000
Closing Date
23 Nov 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner, Coimbatore Corporation
Coimbatore Corporation, Main Office, Big bazaar street, Town hall, Coimbatore-1
Maintenance and repair works to the Corporation higher secondary school at Ranganathapuram in ward no.67, Central zone.
2023_MAWS_387301_7
e74/2023 SFC school
Open Tender
Civil Works
Works
150 days
COIMBATORE
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹30,000
26 Apr 2024
10 Nov 2023
24 Nov 2023
10 Nov 2023
23 Nov 2023
10 Nov 2023
Amount
Dismantling the existing damaged Brick or stone in cement mortar walls under 3 mtr height as per the departmental officer etc.,complete.
Dismantling the Exist damaged Weathering Course and Pressed tiles as per the direction of Departmental officers etc. completed.
Dismantling The Floor Finish and dadooing walls in cement mortar with mosaic tiles,Glazed Tiles, Clay Tiles. Cuddapah Slabas per the instruction of Departmental officers etc., Complete
Earth work excavation foundation in all soils and sub soils including softdisintegrated rock and soft rock to the fulldepth as may be directed except in hard rockrequiring blasting, including necessary string,strutting, shuttering,bailing or pumping outsub soil water, removal of slush wherevernecessary and also including refilling thesidesof foundations with excavated soil in layers of15cm, thick well rammed and consolidateddepositing thesurplus earth within ghtecompound in places shown by the departmental officers with all leads and liftsand clearing and levelling the site etc.
Cement concrete of mix 1:4:8 (one cement fours and and eight couse aggregate) using hard broken granite stone jelly of 40 mmgauge for foundation levelling course, including shuttering, dewatering wherever necessary and laid complete complying with standard specifications and drawings and as directed by the departmental Engineers including all cost curing etc., complete I layers of not more than 15cm thick & conveyance of materials laying curing etc., complete.
Supplying and erecting centering for side and soffits including necessary supports and strutting upto 3.29m high for plane surfaces such as side slabs of RCC boxing and similar vertical RCC slabs, FACIA, Drop etc., in all floor with all cross bracing using mild steel sheets of size of 90cm X 60cm and BG 10 stiffened with welded mild steel angles of size 25X25X3mm for boardinglaid over country wood joists of size 10cm x 6.5cm spaced at about 90cm C/C and supported by casurina props of 10cm to 13cm dia spaced at 75cm C/C etc., completed as directed. Sl.No.123B Part-II
Cement concrete of mix 1:2:4(one cement, two and and four couse aggregate) using hard broken granite stone jelly of 200 mmgauge for foundation levelling course, including shuttering, dewatering wherever necessary and laid complete complying with standard specifications and drawings and as directed by the departmental Engineers including all cost curing etc., complete.
Supplying, fabricating and placing in position TMT/CTD rods for all RCC works including cost of steel and binding wire also in all floors complete complying with standard specification
Supplying and erecting CENTERING for sides and sofits including supports and strutting up to 3.29 m high for plane surfaces such as RCC SLABS, with all cross bracings using mild steel sheets of size 90cm X 60cm and BG 10 stiffened with welded mild steel angles of size 25mm * 25mm * 3mm for boarding laid over country wood joists of size 10cm X 6.50cm spaced at about 90cm centre to centre and supported by Casuarinas props of 10cm to 13cm dia spaced at 75cm centre to centre etc., complete and as directed.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers -
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification -
Paving the floor with polished Shahabad stones slab of size below 600 X 600mmX20mm thick machine cut edges over the existing bed of concrete with cement mortar 1:3 (one cement and three sand) to 20mm thick in all floors over white cement slurly layer of 3mm thick over this laid in situ and pointed with white cement neatly and fixed in position so as to make perfectly smooth and shining to the alignment including cutting the shahabad to size with machine cutting, polishing using different grade of corborandum stone, oxalic acid, tin oxide etc., and including hire charges or polishing machinery etc., completed.
Supplying and Laying Hydraulic Pressed Paver Block Providing and laying of 63 mm thick high strength of 9 Hydraulic Pressed Paver Block in size of minimum compressive strength of 40 N/mm2 In uniform shape of approved make to be laid in flurring bone pattern with stone dust cushion below the uniform shap of approved non skitting surface in the top and the rate including leveling the base perpareation of pavers as sub base, stone dust cushion 150 mm thick laying out of pavement cut the pieces to fix the edge vibring the paversl sweeping transporting loading unloading of laying paver block as per the standard specifications
plastering with cement mortar 1:3 mix 12mm thick in all floor as directed by the departmental Engineers.etc.Complete
plastering with cement mortar 1:5 mix 12mm thick in all floor as directed by the departmental Engineers.
Painting with first quality emulsion paint two coats including through cleaning, scrapping, removal of dust and including necessary plaster of paris putty works wherever required etc., completed.
Painting with enamel paint old coats over base coat for old iron works using good quality and approved colour etc. completed.
Painting with green paint two coats over base coat for old Board works using good quality and approved colour etc. completed.
Supply and run of 2 of 4 sq mm(56/.3) PVC insulated SC unsheathed Cu.Conductor of 1100 v Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch and making good of the concealed portion with suitable colour for PVC concealed light / fan Point (for electronic regulator) (5 points per coil) SD-21
Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories in flush with wall with 150mm x100mm x 75mm MS switch box with 3mm thick hylum sheet cover for 5A 3pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed plug point. SD-38
Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe concealed in wall and ceiling with MS accessories in flush with wall with 150mm x 100mm x 75mm MS switch box concealed type with 3mm thick hylum sheet cover for 15A 3 pin flush type non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire and rnaking good of the concealed portion for concealed power plug point.SD-40
Supply and fixing of WT bulk head fitting with guard suitable for 11W CFL lamp with CFL incuding all cost etc complete SD-83
18 W LED Tubelight for T8 Fitting Single side (15- e)
Supply and fixing of 1200 mm (48”) AC ceiling fan complete with energy efficient fan of 28 W Regulator with 0.3 m down rod on existing clamp approved brand and good quality as per the departmental officers instruction etc.,Complete (SD 108)
Earthling as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangemen using charcoal, common salt, G.I.reducer, check nuts etc., and masonry work and providing RCC cover slab 38mm thick for the Brick masonry including cost of steel and fabrication of reinforcement etc., complete in all respects as directed by the departmental officers (SD 233)
supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with 1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting .
Supply and run of 2 of 6 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') bent at both ends with necessary angle iron up right and end supports for mains
.Supply and delivery of borewell submersible pumpset 2.0 HP with vertical type with all accessories with latest FS8034 in general for the following duty conditions the pumpset should have diagonally balanced bronze impler and stainless shaft for motor and pump and directly coupled to a suitable capacity continuous rated three phase fifty cycles 22/440 volts AC supply motor should be as per ISI with upto date amendment. The starter winding should be made from high conductivity PVC insulated 3 core flat copper cable of suitable size of work.
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
M. DHANDAPANI
BRINDAVAN AGENCY
S RAJATHI
R SELVARAJ
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .