Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
25 Jun 2026, 12:00 pm4d left
Similar tender results from the same govt authority in the past 3 years.
SE AK Singh
Superintending Engineer E/M Circle, P.W.D. Kanpur
Electrification work of record room, meeting hall and toilet on the first floor of Assistant Divisional Transport Office, Lalitpur.
2026_CEEMP_1159061_1
975C/06C-EMC/26-27, Dated-27-05-2026
Open Tender
Electrical Works
270 days
Jhansi
Please refer Tender documents.
4 documents required · 4 mandatory
₹766
Electrical/Mechanical Division PWD Jhansi
₹1.1 L
Jhansi
10 Jun 2026
10 Jun 2026
25 Jun 2026
10 Jun 2026
25 Jun 2026
10 Jun 2026
17 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only.
I/C- 200A / 415V MCCB - 1No.
O/C- 63A MCCB - 3Nos. , 32A MCCB-3No. | 1 | Nos. | 2,67,297 | ₹2,67,297 |
| 2 | Wiring for Light and Street Light point Point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group C) | 57 | Each | 1,247 | ₹71,079 |
| 3 | Wiring for Fan and Fresh air Point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Group C) | 19 | Each | 1,247 | ₹23,693 |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings)
(For Plug Point and Aquaguard)((2 No. for TV)(2 No. for Computer) | 20 | Each | 399 | ₹7,980 |
| 5 | Supplying and drawing 1 x 1.5 sq. mm size of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (For Inverter Wiring) | 60 | Mtr | 37 | ₹2,220 |
| 6 | Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 25 A modular socket outlet with 25 A modular SP MCB C curve including connections painting etc. as required. (AC & Geyser) | 4 | Nos. | 591 | ₹2,364 |
| 7 | Supply and Fixing of suitable size GI box with modular plate and cover in front of surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required. (PP) | 6 | Nos. | 482 | ₹2,892 |
| 8 | Supply and Fixing of 4 way (4+12), Double Door, Horizontal type three pole and neutral, sheet steel, MCB Distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator). | 1 | Nos. | 3,205 | ₹3,205 |
| 9 | S/F of 63Amp Four Pole MCB (10KA), C curve
Make-Havells or equivalent | 1 | Nos. | 2,093 | ₹2,093 |
| 10 | Supplying and fixing of 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | 3 | Nos. | 2,102 | ₹6,306 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_2172297.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid