Execution of all types of Indoor works for installation/testing/commissioning of new Electronic Interlocking of BRND, UKR, NPRD, DTL & NGE station of SEC Railway in connection with BRND-BRH doubling work and S&T outdoor work in via duct locations (BRND-BRH section) and related S&T works for phase commissioning in BRND-BRH section .
771-BRND-UKR-NPRD-DTL
771-BRND-UKR-NPRD-DTL
Open
24 Months
Uttara Kannada, Karnataka
₹0
₹64.7 L
4 Jul 2026
4 Jul 2026
13 Jul 2026
A-Execution of Out Door Signalling work 2022023.50 Below/P
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 1 etc., including bailing out water and disposal of extra soil. (i) all soils including soft rocky area.(a) Depth 1.2 Mtr. & width 0.3 Mtr NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 1 as mentioned above till commissioned.
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning 2 etc., including bailing out water and disposal of extra soil. (i) all soils including soft rocky area.(b) Depth 1.0 Mtr. & width 0.3 Mtr. NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.2 as mentioned above till commissioned.
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting. 3 (a) Chase cutting and smoothening of inside surface of sizes 0.08 m deep and 0.17 m width at platform and cemented floor area. NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.3 as mentioned above till commissioned.
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (ii) Hard rocky area including concreting. (b) Cutting the masonary wall to the depth of 0.25m to 0.75m at the entry of room placing of flexible HDPE pipe or G.I.Pipe (including supply) of suitable size as per drawing No. RE/S&T/ALD/SK/161/81.NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.4 as mentioned above till commissioned.
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (iii) Track crossing, Road Crossing by 5 pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI/HDPE pipe .(a) HDPE pipe/DWC pipe(4 inch dia)NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.5 as mentioned above till commissioned.
Excavation of trench and clearing of roots of trees, bushes, ballast and reconditioning etc., including bailing out water and disposal of extra soil. (iii) Track crossing, Road Crossing by 6 pushing method (HDD method) at culverts/ track / pucca road crossing at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI/HDPE pipe .(b) GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters).NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.6 as mentioned above till commissioned.
Laying of Signalling Cable/Power/Quad cable / PIJF cable in the excavated trench to Drg.No:CON/SK/T/5.Transportation, supply of 'U' clamps and anchoring of cable at every 10 Mtrs with 7 'U' clamp to Drg.No:CSTE/C/Cable/81 including back filling with excavated earth and ramming of trenches after cable laying.NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no. 7 as mentioned above till commissioned.
Supply, Transportation, fabrication and fixing of Hylum sheet of 12 mm thickness as per site requirement.
Laying and Fixing of galvanised iron pipe (GI Pipe) with threaded collars (for jointing pipe) of 80 mm nominal dia Spec.No.IS-1239 medium grade, on bridges, culverts, drains including supply a n d transportation o f G I pipes a n d a l l other materials required f o r fixing t h e p i p e to 9 Drg.No.Con/SK/T/2 and drawing of Signal/Power/Quad cables inside the pipe with masonary works over the entire length of the bridge and at entry and exit of the culvert and curing for 72 hrs, drilling of holes on the pipe at 10 cm apart to be clamped 2 Mtrs apart on culvert, for the Signalling, quad, power cable.NOTE : (1) This includes guarding of cables, relaying of cables and redoing of cable jointing in case of the thefts or otherwise at contractor's own cost for item no.9 as mentioned above till commissioned.
Installation and Fixing of "E" type lock along with Welding Work .
Installation, testing and commissioning of sliding boom LC gates complete which includes casting of concrete foundation including surrounding earthwork along the foundation (Dia- 11 30 cm & depth-100 cm total ten numbers per gate), fixing and welding of channel, fixing of clamps, cutting of rail post, fixing of lock post with two numbers excavation of Pit casting of concrete foundation for "B" type foundation per gate, laying of cable for road crossing and fixing of MS plate/channel also as requirement of the site condition.
The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus case, fixing of terninals, fuse blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus c a s e a s required, testing, 12 commissioning including subsequent alterations (if required), bunching of cables, earthing o f cable, armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. (b) Steel appartus case (half) with 4 Nos. of SS foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest.NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate.
(a)Alteration/ Modifications in the existing location boxes, fixing of equipments, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same.
Excavation of earth pit, transportation, placing and fixing of earth electrode with 14 construction of cement encloser to Drg. No.CON/SK/T/9 and CON/SK/T/9A and drawal of GI wire wrapped on MS strip (35 x 6 mm) from earth electrode to all signalling equipments, including fixing and soldering of lugs at both end of the wire.
The excavation of pit, casting of concrete foundation including surrounding earthwork along the foundation, erection, installation and wiring of steel appartus case, fixing of terninals, fuse blocks, signal transformer, current transformer, filament switching unit, track battery chargers, adjustable/fixed resistances, choke coils, Fuses, Relays, E type locks , termination of cables, cable insertion, wiring to draw 110V AC therefore in the new apparatus c a s e a s required, testing, commissioning including subsequent alterations (if required), bunching of cables, earthing o f cable, 15 armours etc. Painting of the apparatus case inside and outside after clearing the surface thoroughly and first coating of anti -corrosive paint and subsequent two coatings of Alluminium paint outside and Red Oxide inside and lettering. 18 mm Hylum sheet for location box shelf and 12 mm for cable termination in location box. (a) Steel appartus case (large) to Drg.No.CON/SK/T/8 with 4 Nos. o f SS foundation bolts 20mm x 460mm to Drg.No. SA-112 A/M or latest. NOTE: - Payment can be released in a part for the above said work after completion of-(i) Foundation- 30%, (ii) Errection - 15% , (iii) Wiring, testing, painting, sand filling, plastering, earthing & writings etc - 45% , (iv) Commissioning - 10% of the rate.
Collecting, stacking with deployment of Man power, Hydra etc for Loading/ Unloading 16 and Transportation of Materials (Fresh/Released/ Unused) from (i) work site to GSD/Raipur, (ii) work site to the stotre of SSE(SIG)/CON,(iii) any store depot to any other store depot over Indian railways as decided by Railway Administation by suitable Trucks and stacking properly. Here Job unit stands for TON-KM.
Dismantling of the following: - ix) Operating cum indication Panel.
Dismantling of the following: - iv) Battery charger, Battery set etc.TLBI, DLBI and other Misc. equipments.
Dismantling of the following: - iii) Relay racks with all fittings, battery racks complete, Equipment rack complete, SM's slide.
Erection a n d commissioning o f Lifting Barrier assembly complete including boom 20 support, positive boom locking device, Emergency crank handle attechment, Timer unit to adjust the time for operating the barrier, Fixing of Hooters/Flashers on either side of gate barriers, 1 (one) control panel, weather proof painting, lettering, Neccessary MS weight for balancing the booms, etc.
Excavation & casting of foundation for stop post.
Excavation & casting of pedestal foundation for left/right hand boom of lifting barriers.
(c) Installation of retro reflective signal/shunt signal enameled number legend board.
Installation of signal posts for Multiple Aspect Colour Light Signals complete with signal units, bases, LED unit, fixing and wiring of current transformers of LED units, ladders & other fittings, excavation of pit, casting of cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of the signal/signal post with necessary earthed screen 24 protection arrangement, including drawing of cable through signal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply and fixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light Signal Post drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. (ii) 3 ASPECT/4 ASPECT
nstallation of signal posts for Multiple Aspect Colour Light Signals complete with signal units, bases, LED unit, fixing and wiring of current transformers of LED units, ladders & other 25 fittings, excavation of pit, casting of cement concrete foundations with necessary water outlets, erection and fixing of complete fittings of the signal/signal post with necessary earthed screen protection arrangement, including drawing of cable through signal posts, termination of cables, wiring, testing and commissioning, two coat painting and lettering, supply and fixing of speed boards if required for the following:- NOTE:- The foundation for Multiple Aspect Colour Light Signal Post drg. No. Con/SK/T/12 and and the foundation bolts shall be of sizes 24 mm x 915 mm to Drg. No. SA- 116A/M and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA- 110A/M ( 4 nos. for each) with two nuts and two washers each per bolt. (i) 2 ASPECT
(b) Supply o f retro reflective signal/shunt signal enameled number legend board of size- 300mm X 200mm X 3mm (minimum) made u p of alluminium composite - 4 panel (ACP) with white back ground and alphabets/numbers in black along with fixing clamps.
(a) Supply & Erection alongwith casting of foundation of Stop board /Sighting board/SLB/BSLB/legend board as per approved drawings.
Installation, testing and commissioning of Position Light shunt signal (Independent), posts complete with lamps/LED lamps, LED units, Bases and other fittings, excavation of pit, casting o f cement concrete foundation, fixing o f complete fittings o f signal, L E D lamps, current regulator 28 including foundation bolts, washers, nuts, termination of cables, wiring, painting and lettering as required. NOTE:- The foundation for position light shunt signal Drg. No. Con/SK/T/13 and bolts for each foundation for above shall be of size 20 mm x 305 mm to Drg. No. SA-110A/M ( 4 nos. for each) with two nuts and two washers each per bolt.Note: Payment can be released in a part for the above said works after completion of-(i) Foundation- 30%,(ii) Errection - 15%, (iii) Wiring, testing, painting,sand filling, plastering, earthing & writings etc - 45%, (iv) Commissioning - 10% of the rate.
Fixing, cable drawing and termination, wiring, painting, lettering, testing and commissioning of Junction type Route indicator complete along with lamp/LED unit.(i) 1/2 Way
Fixing, cable drawing and termination, wiring, painting, lettering, testing and commissioning of Junction type Route indicator complete along with lamp/LED unit.(ii) 3/4 Way. Above/
B-SUPPLY OF FERROUS MATERIALS 997590.00 Below/P
Relay Rack for 'Q' Series Relay as per Drg. No: SK/DRG/OL/SER/192 SH 2/2. The relay racks must be powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.
Composite Relay Rack as per drg.No.SK/DRG/OL/SER/192- SH1/2.The relay racks must be powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.
Cable termination racks as per Drg. No:SK/DRG/OL/SER/197. The relay racks must be powder coated of stone grey colour. Inspection by Rep. of Railway Engineer.
Wiring ladder of 25x25x3mm. Aluminum angle and 20x3mm.flat, 2 Mtr. Inspection by Rep. of Railway Engineer.
Negative Bus bar16 way 18 ". Inspection by Rep. of Railway Engineer.
Earth Electrodes to Drg. No: Con/SK/8/3/84. Inspection by RITES.
Pad Locks of godrej make model Nav-tal - 6 Levers - Long Shackle (3 keys) or latest. Inspection by Rep. of Railway Engineer.
Supply of following material, Inspection by Rep. of Railway Engineer. (a) 2 conductor through terminal block, 1000 Volt Ac, 125 AMP, suitable for conductor of size : 10,16 & 25 sq mm, wago model No. 285 135 Grey colour; make wago or similar. (10 sq mm, 16 sq mm, 25 sq mm).
Supply of following material, Inspection by Rep. of Railway Engineer. (b) Adjacent Jumper for above TB, WAGO PNo. 285.435
Supply of following material, Inspection by Rep. of Railway Engineer. (g) Operating tools with partially insulated shaft, P No. 210-721.
Supply of following material, Inspection by Rep. of Railway Engineer. (a) 2 conductor through terminal block, 1000 Volt Ac, 232 AMP, suitable for conductor of size : 70 sq mm, wago model No. 285 195 Grey colour. make wago or similar.
Supply of following material, Inspection by Rep. of Railway Engineer. (f) Allen Key WRENCH with partially insulated shaft, P No. 285 -172. Above/
Location survey of cable route and preparation of tentative and final cable route plan as per approved format in the section including supply of final route plan after the cables are laid and commissioned indicating clearly the exact position of the cable, joints and other critical items with reference to OHE mast & other fixed point, etc. in 12( twelve) Nos. hard bound copies on white bond paper of maximum A-3 size (well documented and bound with plastic covers).B46
Excavation of trenches of following depth and width at the bottom of the trench 2 including clearing of roots bushes etc. for all types of soils including morrum, hard soil mixed with boulders etc. This work include back filling the trench, ramming, consolidation of soil as well as disposal of extra soil after cable is placed in the trench. After mansoon the route is to be attended for back filling the rain cuts, wash out of soils where ever found. i) Depth 1.2 Mtr. & Width 0.3 Mtr.
Excavation of trenches of following depth and width at the bottom of the trench 3 including clearing of roots bushes etc. for all types of soils including morrum, hard soil mixed with boulders etc. This work include back filling the trench, ramming, consolidation of soil as well as disposal of extra soil after cable is placed in the trench. After mansoon the route is to be attended for back filling the rain cuts, wash out of soils where ever found. ii) Depth 1.0 Mtr. & Width 0.3Mtr.
Excavation of trenches including clearing of roots o f trees etc. i n hard/rocky soil by 4 chiseling up to a depth of minimum 0.6 Mtr. and width 0.3 Mtr. at the bottom, supply and placing RCC hume pipe section as per drawing on sieved soil of 30mm over cable / HDPE pipe and concreting through - out the length upto a layer of 75mm. Then back filling the trench and then ramming of soil .
Cutting the chase upto a depth of minimum 500 mm.and smoothening of inside surface in concrete and beds of rocks, cable laying/ placing HDPE pipe & concreting upto the ground level.
Laying and Fixing of galvanised iron pipe (GI Pipe) with threaded collars (for jointing pipe) of 80 mm nominal dia Spec.No.IS-1239 medium grade, on bridges, culverts, drains including 6 supply and transportation of GI pipes and all other materials required for fixing the pipe to Drg.No.Con/SK/T/2 and drawing of Signal/Power/Quad cables inside the pipe with masonary works over the entire length of the bridge and at entry and exit of the culvert and curing for 72 hrs, drilling of holes on the pipe at 10 cm apart to be clamped 2 Mtrs apart on culvert, for the Signalling, quad, power cable.
Laying of RCC pipe including supply of required quantity at site with collars (for 7 jointing pipe) 150mm nominal dia to Spec.No:IS-458 in excavated trench (at bridges, culverts, roads, under railway track, Platform crossing, level crossing gate etc.) and drawing of HDPE pipe/ Power cable/ Quad cables/Jelly filled cables , etc. through pipe.
Track crossing, Road Crossing by pushing method (HDD method) at culverts/ Railway track / pucca road/Kuchha road at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI/HDPE pipe. (a) HDPE pipe/DWC pipe(4 inch dia)
Track crossing, Road Crossing by pushing method (HDD method) at culverts/ Railway 9 track / pucca road/Kuchha road at a depth not less than 1 meter with reference to bottom of rail/road surface including supply of GI/HDPE pipe. (b) GI pipe with 76 mm dia, Spec. No. -1239 medium grade (for the length of pushing more than 05 meters).
Transportation including loading/unloading of HDPE pipe from the stores of railway to the work site, laying of the same (with 4 mm nylon rope pre-inserted inside the HDPE pipe) in excavated trench/already laid GI/RCC pipes/tubes, jointing, levelling and end sealing the pipes.
Transportation, loading/unloading of OFC from the stores of railway to the work site with care, pushing/pulling OFC through the HDPE pipes, sealing of the duct by sealling /caps plugs. 11 The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. This also includes testing of cable drums in the store premises before transportation and submissions of results thereof. Empty cable drums to be returned by the contractor. The cable drums with unused cable at site to be returned by the contractor to the stores depot of SSE/Tele/Con/BSP.
Laying of Quad Cable, PIJF cable of different sizes, power cable of different size in the excavated trench, inside GI,RCC and HDPE pipes. This includes loading/unloading & transportation of 12 cables from the stores of railway as per the availability.Wherever several cables o f different categories have t o b e laid i n t h e same trench/path, t h e provision of seperation of various cable should be as advised by the site incharge of the Railway. Empty cable drums to be returned by the contractor.The cable drums with unused cable at site to be returned by the contracrtor from site to Stores depot Bilaspur.
Supply, Installation and commissioning of Surge & Lightning protection arrangement 13 in the cable huts for all the equipments including all the circuits derived from MUX at the stations and Ring Earth (Six Earth pits). Each earth shall be as per RDSO Specification no.RDSO/SPN/197/ 2008 (drawings enclosed)
Installation and commissioning of Fibre Distribution Frame.
Fixing o f concrete cable route marker a t 5 0 meter(approx) a n d a t diversion point 15 including supply & transportation o f cable route marker a t site. Detail size & fixing of cable route marker should be followed as per drawing no. SDO/Cable laying/020. Marker should be written as "RLY TELE"(both side).
Cutting the masonary wall to the depth of 0.25m to 0.75m at the entry of room 16 placing of flexible HDPE pipe or G.I.Pipe (including suppply) of suitable size as per instructions of Railway site in charge and repairing of masonary wall and cement plastering after the cable is taken inside the flexible HDPE pipe/G.I.Pipe with clamps as per drawing No. RE/S&T/ALD/SK/161/81.
Transportation, installation o f optical fibre joint closure and splicing o f Optical fibre cable (2 x 24 fibres) and testing, Optical fibre cable splicing shall be done in the presence of Railway's representative. O n l y j o i n t closure s h a l l issued b y t h e Railway. A l l other tools/test 17 equipments required shall be arranged by the Contractor. This also includes excavation of earth for construction of masonary pit of bricks (inside complete plastered), the inner size of pit 1.2m x 1.2m (depth 0.75m) in all types of soils for keeping cable coils at the location of OFC joints, filling the pit with sand after jointing of cables, ramming and covering with RCC slab as per Drg. and instructions of site incharge of Railway.
Transportation, installation of Optical Fibre termination box and splicing of Optic 18 Fibre Cable (24 fibre) inside the termination box with provision of taking out fibre of OFC as required. This includes supply of installation accesories (as required) as detailed in technical specification and advised by Railway's Engineer-at-site.This also includes End to End testing of all fibres of the optical fibre cable terminated between cable hut to cable hut of each station.
Transportation & Execution of following kinds of joints on Quad Cable using 19 thermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling and ramming after jointing. (a) Derivation/ transformer joints with V.F. Transformers and derivation joint for L.C.Gate & Pump House on Quad/jelly filled Telecom Cable.
Transportation & Execution of following kinds of joints on Quad Cable using thermoshrink jointing kit. This also includes excavation of cable joint pit of size 1.2m x 1.2m x 1.0m in all types of soil for jointing of copper cables, back filling and ramming after jointing. (b) straight through joint on Quad cable/10-20-50 pairs PIJF Cable
Transportation and fixing of following types of C.T.Box and termination of cable as per details of jointing schedule approved by the Railway Engineers. 20 pair C.T.Box (wago type)
Provision o f Earthing protection arrangement a s p e r R DSO drawing n o . TC A 565 (Adv.). All the materials including earth electrodes required for the work to be supplied by the contractor.
Supply transportation, fixing, wiring, termination of cable, erection of rail post of size 2.8mtrs including foundation of post in cement concreate (1:2:4) as per the direction of the site Engineer incharge of Railway, testing and commissioning of six pin emergency socket box complete cast iron make as per Drg. No. SE/T/50/76. This include transportation of rail posts (provided by the 23 Railway) from Bilaspur o r any place i n the section t o work site, fixing of 40 mm dia G.I.Pipe and emergency socket box. Cast iron emergency socket box with complete fittings are to be first supplied to the stores of SSE/T-W/BSP and then collected from there for execution. Supply of U-bolt for fixing emergency socket, cutting of Rails to the size and welding of G.I.Pipe on the rail post will be done by the Contractor. This work includes painting of rail posts with black and white paints after two times primer coating. Note :- 10 Nos of emergency sockets with complete fittings including Cast iron box to be supplied extra as spare within the same cost.
Transportation, Wiring and installation of magneto telephone at L.C.Gate/pump house or the places as advised by the site incharge.This includes supply and fixing of Telephone rack of approved design by the contractor.
Dismantaling of unused/old emergency socket post approximate dimention Height - 1.25 mtr * cross section- 1 5 c m x 1 5 cm (drg enclosed) a n d transportation f r o m s i t e t o GSD 25 store/Raipur, which includes excavation of soil/ concrete to a depth o f 1 5 c m from the surface and back filling and ramming after cutting the post.This is required to avoid projection of remain of post over the ground level.The contractor must ensure, that rail post shall be cut below the normal ground surface area.
Supply and fixing of PVC casing caping 25mm x 25mm size for indoor wiring. This includes drawal of wires in the casing caping and termination of wire at end point. The work should be carried out as per the instruction of Railway site Engineer.
Transportation, installation, testing & commissioning of 4W way station equipment 27 DTMF type and way station 4W control telephone including termination of the electric wires, battery wires, switch board cable on the equipment. The termination shall be done using eyelets of required size. The way station equipments shall be fixed over the wall on board of approved design. Board and all the materials required for fixing and termination to be supplied by the contractor.
Transportation, installation and commissioning of 12V. Power supply unit for telecom 28 installations at wayside stations on wall mounting stand of approved design including termination of Power supply cable all other materials required for fixing and termination to be supplied by the contractor.
Transportation, Installation & commissioning o f SDH ADM, Primary D/I MUX with all accessories and power supply, racks, runway ladder etc. in cable huts including wiring of all the equipments u p t o C.T. Box install f o r Outdoor/ Derivation cables a s p e r the requirement at each 29 station. Note:- The work involves fixing of 19" rack,Installation & wiring of equipment connecting to 4 8 V. b u s b a r including supply o f a l l wires and connectors. The equipment shall be mounted in shelves of standard 19" racks. All 21 E1 streams shall be suitably terminated on Digital Distribution Frame. All the wiring shall be done in accordance with wiring instructions given in as per Annexure- VII . Above/
D-Supply of Telecom materials 6922034.00 Below/P
Supply of Optical fibre joint closure for straight through joint with modification for 24 fibre OFC as per Specification. No. RDSO/SPN/TC/68/2013 (with latest amendment) complete with all accessories (sealing with mechanical clamp facility) make Raychem or similar. Inspection by Rep. of Railway Engineer.
Supply of Optical fibre termination box for 2 x 24 fibre armoured cable complete with all accessories with the fixing arrangement to accommodate all the fibres a s per specification No. IRS:TC:81-2000 (with latest amendment). Inspection by Rep. of Railway Engineer.
Supply of Universal thermoshrink jointing kit for derivation/ transformer joint for Jelly filled Six quad cable conforming to RDSO Spec.No :IRS-TC-77/2006(Rev.1) (With latest amendment). Inspection by Rep. of Railway Engineer.
Supply of VF Tapping Transformer 1120:470 (rack mountable) as per specification No. IRS- TC-22/76(With latest amendment). Inspection by Rep. of Railway Engineer
Supply of permenantly lubricated HDPE pipe with outer dia 50mm, inner dia - 42mm 5 thickness - 4mm with suitable couplers, plugs, end caps etc. as per technical specification No. G/CDS-08/01 Dec. 1999. Supply to be made in length of 500 mtrs with + /-10% tolerance. Inspection by Rep. of Railway Engineer (Green Colour- 4Km & orange colour 5 Km.)
Supply of 4 wire Way-station Control Equipment DTMF type as per IRS Spec. No. : TC 60/2007(with latest amendment) including way station control telephone as per RDSO spec. no.IRS TC 38-97(latest amendment). Inspection by Rep. of Railway Engineer.
Supply of 12 V. Power supply unit for Telecom. Installation for way-side equipment in 7 25 KV Electrified area suitable for 6 equipment of DTMF type as per IRS Spec. No : TC 72-97(with latest amendment) including 12V, 7AH maintenance free battery. Inspection by Rep. of Railway Engineer.
Supply of one quad VF trasformer assembly 2T for quad cable (470 : 1120) for derivation joints to specification No. IRS-TC-76/2000 (With latest amendment). Inspection by Rep. of Railway Engineer.
Supply of loose tube fibre pigtail with FC/PC connector at one end each of 8 Mtrs. Length as per TEC Specification No. G/OFJ-01/03 JUN 99 (With latest amendment). Inspection by Rep. of Railway Engineer.
Supply of following type of Wago Make Terminal block(with lever type disconnection & reconnection facility) duly fitted in C.T. box of approved quality, suitable for termination of 0.9mm wire. Inspection by Rep. of Railway Engineer. (b) 20 Pair
Supply of following types of twisted pair PVC switch board cable, conductor of size 0.6mm. dia annealed copper conforming to IRS-TC-24/91 or ITD 1138. Inspection by Rep. of Railway Engineer. (a) 5 pair
Supply of following types of twisted pair PVC switch board cable, conductor of size 0.6mm. dia annealed copper conforming to IRS-TC-24/91 or ITD 1138. Inspection by Rep. of Railway Engineer. (b)10 pair
Supply of following types of twisted pair PVC switch board cable, conductor of size 0.6mm. dia annealed copper conforming to IRS-TC-24/91 or ITD 1138. Inspection by Rep. of Railway Engineer. (c) 20 pair .
Supply of programmable Primary Digital Drop Insert Multiplexer complete with all accessories from RDSO approved vendor as per RDSO specification IRS TC 68-12 (with latest amendment) including connectors and cables required for installation including 100 pair Krone type 14 MDF. Each channel card shall have minimum four channels per card. The single sub rack shall be capable of being equipped up to min. 60 Channels without additional power supply unit. Specification as per Annexure I. The MUX shall be wired & equipped for 30 channels, with following circuits:- 16 Nos. VF 2W/4W E & M circuits, 8 nos. of 2 wire FXO circuits, 6 Nos. 2W.Subs/Hotline circuits along with ringer card., compatible to existing PUNCOM make MUX. Inspection by RDSO.
(i) Motorola VHF Mobile Synthesized Trans-receiver, Model-GM-339, 146 t o 174 MHz frequency range 16 programmable channels, 25 watt RF power out put maximum 2/5 KHz channel 15 specing compact palm microphone, Cable and hang u p clip, non locking mounting bracket power cable, limited accessory connectors front facing internal speaker operators handbook mini UHF Male to Female adaptor (Antenna) is not included.. Inspection by Rep. of Railway Engineer (ii) 1/4 wave VHF rooftop mount mobile whip Antenna with mounting bracket 30 Mtr cable and mini UHF connector. (iii) 3 DB gain VHF roof top mount mobile whip Antenna with mounting bracket 30 Mtr. Cable and mini UHF connector.
Supply of managed expandable rack type STM-4, equipped STM-1, ADM S1.1, as per technical Specification n o . T E C G R N O. GR/SDH-10/02 March 0 5 (with latest amendment) w ith 2 Nos.STM-1 aggregate Optical interface upgradable to STM-4, 21 E1s, and minimum 8 Nos. of 10/100 base T Ethernet port, Orderwire, Power supply unit, subrack, DDF, Installation materials, manuals 16 and other accessories . The equipment should be TEC/BSNL/RDSO approved .The equipment should be fully wired for its ultimate capacity and provide redundency for Power supply and Synchronisation. It shall be possible to use the full capacity of the equipment by adding additional tributary cards. The upgradation of STM-1 to STM-4 shall be without change of a n y internal hardware o f t h e STM equipment. T h e S T M equipment shall h a v e in-built L2 switch f o r Ethernet ports. M a k e -Tejas, compatible to existing STM System in the section. Inspection by RDSO.
Supply of covered 19" racks (2200MM(H)X600MM(W)X600MM(D).) complete with all 17 fittings for housing the sub-rack SDH ADMs & PD MUXs( as per instsruction of railway ) fully wired including P o w e r S u p p l y Distribution system, r a c k exhaust fan(48vdc) a n d o t h e r installation accessories for installation. Note : It should have door on both sides with locking arrangement. (Make: APW or RITTAL or similar) Inspection by Rep. of Railway Engineer.
Supply of UTP CAT 6 Cable (Roll is 305 Mtr). Make Amp or Molex. Inspection by Rep. of Railway Engineer.
Supply of 4 8 Volt,200 AH maintenance fre e VRLA batteries duly charged as per specification no.IRS:S-93/96A (with latest amendment). Inspection by RDSO.
Supply of Fibre Distribution Frame (24 Fibre) as per RDSO specification No. 81-2000 (Part-D) (with latest amendment) including 24 Nos. FCPC adopter. Inspection by Rep. of Railway Engineer. Above/
E-Supply & Installation of new Electronic Interlocking System 177409550.00 Below/P
Design, manufacture and supply of Electronic Interlocking (EI) system complete as per RDSO specification no. RDSO/SPN/192/2005 with latest amendment,and special conditions of contract mainly consisting of Central processing equipment, Interfacing Equipment/ Relays as per RE requirements and hot standby with Dual VDU [two nos. of industrial grade high resolution VDUs (65" or higher size-4K) conforming to SIL-II certification for operator console at central location, Interfacing Relays, Interconnecting cables and jumper wires, three nos. of Maintenance Terminals (PC & VDU as maintenance console-65" or higher size-4K(Industry standard PC) along with laser printer at central & end goomties locations housing for EI Equipments and Relay Racks, Fixture, Class 'A' protection at each EI room/goomty, mounting arrangements and accessories necessary to make the EI system functional,Tentative SIP is enclosed for station. This provision of hot-standby arrangement must have the supply, installation and commissioning of associated cards for the above arrangement as required with supply & installation of supporting software and drives etc. Also Optical Fiber link with loop back (Protecion ring) between center to end goomties. (Detail connectivity of EI's through OFC between center to end goomty is enclosed). Embedded industrial grade fan less PCs should be of rugged and reliable type like MOXA series V 2406A, Kontron MPCX28R, MEN BC50M or latest with compact flash drives in non-AC and in normal environment to be used. Minimum requirment of Embedded PC for EI shall be as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 (General requirement is enclosed in Annexure 'A'). The optical fiber connectivity with fiber management and diagnostic analysis system shall be provided to connect EI with SM room PC terminal. All interface relays for EI shall be supplied by Railways. Supply of essential spares (10% of main equipment module against the no.-1.). Supply and installation of one PC based work station for data input and configuration, simulation and functional testing, diagnostic & trouble shooting and commissioning of EI System. Instruments and Tool Kits required for rouble shooting and repair of hardware and software. KAVACH Ready interface to be incorporated with EI system. More than 100 Routes(Darritola)
Installation, wiring, Programming, testing (FAT & SAT) a n d commissioning o f EI equipment supplied as per item no.1 above including transportation from consignee depot to site as 2 per original manufacturer's specifications & RDSO specification STE/E/TAN/3012 dt 28.4.2014 or latest and provision of NMS for OFC as per TAN no/STS/E/TAN/3012 under supervision o f OEM's Engineer / authorised representative. This also cover the necessary equipments required to make EI system compatible with datalogger against supplied by tenderer in the instant tender.
Supply of completion drawings and documents of 02 sets as per special condition of contract. (Drawings to be drawn & checked by IRSE/IRSTILO License holder and name/ designation/License number should be mentioned in each sheet of drawing.)
Training of Railway personnel in installation, commissioning, testing, trouble shooting, repairing, modification & alteration in EI system, including supply of hard copies of course module, etc. at site and OEM's manufacturing/production premises. Per
Design, manufacture and supply of Electronic Interlocking (EI) system complete as per RDSO specification no. RDSO/SPN/192/2005 with latest amendment,and special conditions of contract mainly consisting of Central processing equipment, Interfacing Equipment/ Relays as per RE requirements and hot standby with Dual VDU [two nos. of industrial grade high resolution VDUs (65" or higher size-4K) conforming to SIL-II certification for operator console at central location, Interfacing Relays, Interconnecting cables and jumper wires, One nos. of Maintenance Terminals (PC & VDU as maintenance console-65" or higher size-4K(Industry standard PC) along with laser printer at central & end goomties locations housing for EI Equipments and Relay Racks, Fixture, Class 'A' protection at each EI room/goomty, mounting arrangements and accessories necessary to make the EI system functional,Tentative SIP is enclosed for station. This provision of hot-standby arrangement must have the supply, installation and commissioning of associated cards for the above 5 arrangement as required with supply & installation of supporting software and drives etc. Also Optical Fiber link with loop back (Protecion ring) between center to end goomties. (Detail connectivity of EI's through OFC between center to end goomty is enclosed). Embedded industrial grade fan less PCs should be of rugged and reliable type like MOXA series V 2406A, Kontron MPCX28R, MEN BC50M or latest with compact flash drives in non-AC and in normal environment to be used. Minimum requirment of Embedded PC for EI shall be as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 (General requirement is enclosed in Annexure 'A'). The optical fiber connectivity with fiber management and diagnostic analysis system shall be provided to connect EI with SM room PC terminal. All interface relays for EI shall be supplied by Railways. Supply of essential spares (10% of main equipment module against the no.-1.). Supply and installation of one PC based work station for data input and configuration, simulation and functional testing, diagnostic & trouble shooting and commissioning of EI System. Instruments and Tool Kits required for rouble shooting and repair of hardware and software. KAVACH Ready interface to be incorporated with EI system. Less than 100 Routes(Boridand) Per
Design, manufacture and supply of Electronic Interlocking (EI) system complete as per RDSO specification no. RDSO/SPN/192/2005 with latest amendment,and special conditions of contract mainly consisting of Central processing equipment, Interfacing Equipment/ Relays as per RE requirements and hot standby with Dual VDU [two nos. of industrial grade high resolution VDUs (65" or higher size-4K) conforming to SIL-II certification for operator console at central location, Interfacing Relays, Interconnecting cables and jumper wires, One nos. of Maintenance Terminals (PC & VDU as maintenance console-65" or higher size-4K(Industry standard PC) along with laser printer at central & end goomties locations housing for EI Equipments and Relay Racks, Fixture, Class 'A' protection at each EI room/goomty, mounting arrangements and accessories necessary to make the EI system functional,Tentative SIP is enclosed for station. This provision of hot-standby arrangement 6 must have the supply, installation and commissioning of associated cards for the above arrangement as required with supply & installation of supporting software and drives etc. Also Optical Fiber link with loop back (Protecion ring) between center to end goomties. (Detail connectivity of EI's through OFC between center to end goomty is enclosed). Embedded industrial grade fan less PCs should be of rugged and reliable type like MOXA series V 2406A, Kontron MPCX28R, MEN BC50M or latest with compact flash drives in non-AC and in normal environment to be used. Minimum requirment of Embedded PC for EI shall be as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 (General requirement is enclosed in Annexure 'A'). The optical fiber connectivity with fiber management and diagnostic analysis system shall be provided to connect EI with SM room PC terminal. All interface relays for EI shall be supplied by Railways. Supply of essential spares (10% of main equipment module against the no.-1.). Supply and installation of one PC based work station for data input and configuration, simulation and functional testing, diagnostic & trouble shooting and commissioning of EI System. Instruments and Tool Kits required for rouble shooting and repair of hardware and software. KAVACH Ready interface to be incorporated with EI system. Less than 100 Routes(Nagpur road) Per
Design, manufacture and supply of Electronic Interlocking (EI) system complete as per RDSO specification no. RDSO/SPN/192/2005 with latest amendment,and special conditions of contract mainly consisting of Central processing equipment, Interfacing Equipment/ Relays as per RE requirements and hot standby with Dual VDU [two nos. of industrial grade high resolution VDUs (65" or higher size-4K) conforming to SIL-II certification for operator console at central location, Interfacing Relays, Interconnecting cables and jumper wires, One nos. of Maintenance Terminals (PC & VDU as maintenance console-65" or higher size-4K(Industry standard PC) along with laser printer at central & end goomties locations housing for EI Equipments and Relay Racks, Fixture, Class 'A' protection at each EI room/goomty, mounting arrangements and accessories necessary to make the EI system functional,Tentative SIP is enclosed for station. This provision of hot-standby arrangement 7 must have the supply, installation and commissioning of associated cards for the above arrangement as required with supply & installation of supporting software and drives etc. Also Optical Fiber link with loop back (Protecion ring) between center to end goomties. (Detail connectivity of EI's through OFC between center to end goomty is enclosed). Embedded industrial grade fan less PCs should be of rugged and reliable type like MOXA series V 2406A, Kontron MPCX28R, MEN BC50M or latest with compact flash drives in non-AC and in normal environment to be used. Minimum requirment of Embedded PC for EI shall be as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 (General requirement is enclosed in Annexure 'A'). The optical fiber connectivity with fiber management and diagnostic analysis system shall be provided to connect EI with SM room PC terminal. All interface relays for EI shall be supplied by Railways. Supply of essential spares (10% of main equipment module against the no.-1.). Supply and installation of one PC based work station for data input and configuration, simulation and functional testing, diagnostic & trouble shooting and commissioning of EI System. Instruments and Tool Kits required for rouble shooting and repair of hardware and software. KAVACH Ready interface to be incorporated with EI system. Less than 100 Routes(Nagar) Per
Design, manufacture and supply of Electronic Interlocking (EI) system complete as per RDSO specification no. RDSO/SPN/192/2005 with latest amendment,and special conditions of contract mainly consisting of Central processing equipment, Interfacing Equipment/ Relays as per RE requirements and hot standby with Dual VDU [two nos. of industrial grade high resolution VDUs (65" 8 or higher size-4K) conforming to SIL-II certification for operator console at central location, Interfacing Relays, Interconnecting cables and jumper wires, One nos. of Maintenance Terminals (PC & VDU as maintenance console-65" or higher size-4K(Industry standard PC) along with laser printer at central & end goomties locations housing for EI Equipments and Relay Racks, Fixture, Class 'A' protection at each EI room/goomty, mounting arrangements and accessories necessary to make the EI system functional,Tentative SIP is enclosed for station. This provision of hot-standby arrangement must have the supply, installation and commissioning of associated cards for the above arrangement as required with supply & installation of supporting software and drives etc. Also Optical Fiber link with loop back (Protecion ring) between center to end goomties. (Detail connectivity of EI's through OFC between center to end goomty is enclosed). Embedded industrial grade fan less PCs should be of rugged and reliable type like MOXA series V 2406A, Kontron MPCX28R, MEN BC50M or latest with compact flash drives in non-AC and in normal environment to be used. Minimum requirment of Embedded PC for EI shall be as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 (General requirement is enclosed in Annexure 'A'). The optical fiber connectivity with fiber management and diagnostic analysis system shall be provided to connect EI with SM room PC terminal. All interface relays for EI shall be supplied by Railways. Supply of essential spares (10% of main equipment module against the no.-1.). Supply and installation of one PC based work station for data input and configuration, simulation and functional testing, diagnostic & trouble shooting and commissioning of EI System. Instruments and Tool Kits required for rouble shooting and repair of hardware and software. KAVACH Ready interface to be incorporated with EI system. Less than 100 Routes(Udalkachhar) Above/
A1-Execution of Indoor Signalling work 4606985.00 Below/P
Q-series/Composite Relay Racks and cable termination racks (New). NOTE: Payment 1 can be released in a part for the above said work after completion of- (i) Errection- 15%, (ii) Wiring, testing, painting,earthing & writings etc - 75% , (iii)Commissioning of Relay rack/Composite rack/CTR- 10% of Schedule rate.
Alteration of existing Q-series/Composite Relay Racks and cable termination 2 racks.NOTE: Payment can be released in a part for the above said work after completion of-(i) Errection- 15%,(ii) Wiring, testing, painting,earthing & writings etc - 75% ,(iii)Commissioning of Relay rack/Composite rack/CTR- 10% of Schedule rate.
Installation and wiring of Rotary key transmitters/KLCR on teak wood board enclosed 3 inside a suitable box with front transparent check cover with locking arrangement. This includes 3/4" thick teak wood boards, transparent sheet for box, locking arrangement. 2 nos.of locks for box and 1 No. lock for front transparent sheet.
Modification/Alteration of Data Logger/RTU Digital Input, validatory & yard simulation in both end station of IBS as per directive of Railway Representative.
Installation, cable termination, on the terminals fixed inside the block counter cup 5 board to be made by the contractor as per the advice of the Railway engineer at site. Wiring, painting, lettering, testing and attending to faults therein and commssioning of double line Block instrucment working (in pair), on block counter cup-board along with fixing of block bell equipment and filter units as per the instrucions of the Railways' representative.
Installation, cable termination, wiring, testing & commissioning of Integrated power 6 supply panel as per approved power supply diagram and specification. The contactor has to supply arrangements at central relay room, goomties on original tracing paper of size 60cm.x42cm. with 8 computer prints in the format supplied by railways.
Installation, wiring as per approved wiring diagram, testing and commissioning of control panel (operation cum indication panel) complete with termination of cable, painting and lettering as required. Cable termination in MS rack with ¾th inch thick sal wood strips including fabrication thereof as per requirement of the Railway. Fixing of cable with MS clamps, fixing of terminal block, M.S. wiring ladder with insulated M.S. strips from relay room to panel room, painting and lettering, filling sand under control panel rest table, cable duct, covering the open space around the control panel rest table with bricks lining, masonry work and plastering the same with cement required.
Installation testing and commissioning of DATA LOGGER as per RDSO's Specn. 8 including networking and central monitoring along with installation of remote monitoring software and hardware. The contractor is also required to list out the no. of analog & digital inputs for wiring & operation of the datalogger by taking approval of the Rly. for those inputs. This includes training to 4 staffs at site.
Installation testing and commissioning of Disitilled water plant/Demineralised plant.
Alteration Modification, cable termination, wiring, testing & commissioning of existing 10 Integrated power supply panel as per approved power supply diagram and specification. The contactor has to supply arrangements at central relay room, goomties on original tracing paper of size 60cm.x42cm. with 8 computer prints in the format supplied by railways.
Maintenance of the installation under competent supervisor of contractor.
Installation, cable termination, wiring, testing of magneto telephones.
Installation, cable termination, testing and commissioning of 10/20/50 Pair CT Boxes.
Provision o f simulation arrangement(Track a n d Point simulation board a s w ell as signal lamp simulation board) and its complete wirinig ; arrangement of free home, advance starters, IBS etc as may be required with block working with required temporary relay wiring for controlling the train movement in NI - period with the provision of temporary miniature operation cum indication 14 panel board; deputation of fitter round the clock in NI - period for assisting simulation testing for all the routes as per approved RCC by the Railway officials ; mobilization of additional man power for attending to the Pre - NI block and commissioning of the station within prescribed time limit of NI - period as decided by Railway officials; deputation of staff (one fitter & one helper) at the station for attending to the packing and reallignment of point and crossing etc, in connection with P. Way block for a period of 30 days beyond the commissioning date.
Wiring of door detection Proximity switch to the tag block of dataloggers/RTU (This 15 includes provision of casing and capping and other wiring accessories, excluding 16/0.2 wire which will be supplied by Railways). This includes incorporation of this contact in datalogger simulation & datalogger report.
Installation, testing of door contacts and validation and proximity switch data through Dataloggers/RTU. This includes incorporation of this contact in datalogger simulation & datalogger report
Development of door 'close and open' software logics module & its implementation. Above/
A2-Signalling Design & Drawing 2300390.00 Below/P
Design, Preparation & checking of documents and Circuit diagram and drawings. a) 1 Design and development of Route Control Chart (RCC) in size B(A3) as per SEM. (Drawings to be drawn & checked by IRSE/IRSTILO License holder and name/ designation/License number should be mentioned in each sheet of drawing).
Design, Preparation & checking of documents and Circuit diagram and drawings. b) Design and development of Front Plate Diagram (FPD) conventional/Dual VDU FPD in size W(A1) as per SEM. (Drawings to be drawn & checked by IRSE/IRSTILO License holder and name/ designation/License number should be mentioned in each sheet of drawing).
Design, Preparation & checking of documents and Circuit diagram and drawings. c) 3 Design and development of Station working rule Diagram (SWRD) based on SIP of station in size U(A3) as per SEM. (Drawings to be drawn & checked by IRSE/IRSTILO License holder and name/ designation/License number should be mentioned in each sheet of drawing).
Design, Preparation & checking of documents and Circuit diagram and drawings. e) 4 Design and development of Circuit Diagram/Logic in size B(A3) as per SEM sheet including contact analysis. (Drawings to be drawn & checked by IRSE/IRSTILO License holder and name/ designation/License number should be mentioned in each sheet of drawing).
Design, Preparation & checking of documents and Circuit diagram and drawings. f) 5 Other Signalling Drawing in size U(A3) as per SEM sheet i.e.wiring in location box etc. (Drawings to be drawn & checked by IRSE/IRSTILO License holder and name/ designation/License number should be mentioned in each sheet of drawing).
Design, Preparation & checking of documents and Circuit diagram and drawings. g) Maintenance Register as per Requirement.
Design, Preparation & checking of documents and Circuit diagram and drawings. h) Miniature diagram in size B(A3).
Design, Preparation & checking of documents and Circuit diagram and drawings. i) Photocopy of various drawing in A3 size paper single side. Above/
B2-Supply of Signalling materials 10461138.00 Below/P
(i) Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by RDSO. (a) 7/0.75 mm dia. (Red & Black) (50% each.
(i) Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by RDSO. (b) 3/0.75 mm dia. (Red & Black) (50% each).
(i) Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by RDSO. (c) 16/0.2 mm dia. (80% grey & 20% yellow).
(i) Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by RDSO. (d). Indoor cable as per IRS-S-76/89 with latest ammendment. 60x0.6 mm dia.
(i) Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by RDSO. (e). Indoor cable as per IRS-S-76/89 with latest ammendment. 40x0.6 mm dia.
(ii) Cable PVC insulated single core unsheathed with plain annealed copper conductor 6 as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (a) 1x 1.5 Sq mm flexible wire (Red-45%, Black-45% & Green-10%).
(ii) Cable PVC insulated single core unsheathed with plain annealed copper conductor as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (b) 1x 2.5 Sq mm flexible wire (Red-15%, Black-50%, Green- 20%, blue-7.5% & Yellow- 7.5 %).
(ii) Cable PVC insulated single core unsheathed with plain annealed copper conductor 8 as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (c) 1x 4.0 sq mm flexible wire (Red-45%, Black-45% & Green-10%).
(ii) Cable PVC insulated single core unsheathed with plain annealed copper conductor 9 as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (d) Multi strand ISI copper cable (10 Sq.mm) (Red-45%, Black-45% & Green-10%).
(ii) Cable PVC insulated single core unsheathed with plain annealed copper conductor 10 as per the colour coding scheme of Railways. Spec. no: IRS-S-76/89 with latest ammendment. Inspection by Rep. of Railway Engineer. (e) Multi strand ISI copper cable (16 Sq.mm) (Red-45%, Black-45% & Green-10%).
2 Core Screened (sheilded ) cable size 16/0.20 mm (0.5 sq. mm. Whole) 650 volt grade as per specification No. IS 694/77 with jacket, make Empire or similar.
Supply of rotary CAM swith 4 NO/4NC . Current capacity 6 Amps DC type, -4TD46B, make- KAYCEE or similar. Inspection by Rep. of Railway Engineer.
Installation of above rotary CAM swith 4 NO/4NC .
Electric Key Transmitter (RKT) single Drg. No. : SA -22601(Adv.) Alt.4 with ward No. 2 to 9, spec. no: IRS-S - 21/2001 with latest amendment. Inspection by RDSO.
Supply of Universal thermoshrink jointing kit for derivation/ transformer joint for Jelly filled Six quad cable conforming to RDSO Spec.No :IRS-TC-77/2006(Rev.1) (With latest amendment). Inspection by Rep. of Railway Engineer.
(a) Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no: IRS-S- 78/92 with latest amendment if any. Inspection by RDSO. (i) 1 Amp fuse catridge.
(a) Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no: IRS-S- 78/92 with latest amendment if any. Inspection by RDSO. (ii) 02 Amp fuse catridge.
(a) Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no: IRS-S- 78/92 with latest amendment if any. Inspection by RDSO. (iii) 04 Amp fuse catridge.
(a) Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no: IRS-S- 78/92 with latest amendment if any. Inspection by RDSO. (iv) 06 Amp fuse catridge.
(a) Non-deteriorating type low voltage electric fuse for Railway signalling, rated voltage 240 V AC/DC fuse with cylindrical cap without indication size :14x 51 mm. Spec. no: IRS-S- 78/92 with latest amendment if any. Inspection by RDSO. (v) 16 Amp fuse catridge.
(b) Fuse Block for above fuse catridge, Spec. no: IRS-S-75/2006(rev-2) with latest amendment if any. Inspection by RDSO.
(c)Polymeric Positive Temperature co-efficient device self- restoring type 2/4 Amps, 16 V DC with soldering of 16/0.2 copper wire leads and crimping of copper pin type lugs suitable for Railway signal and Telecom applications. Technical details (i) Holding current- 6Amps, (ii) Max Fault current rating- 100 Amps, (iii) Trip current- 10.2 Amps, (iv) Max time to trip time- 3.3 sec. (v) Max power dissipation - 2.8 watt, (vi) Max resistance= 0.028 ohms, (vii) Minimum resistance= 0.01 ohms, (viii) Max. Voltage rating= 16 VDC. Inspection by Rep. of Railway Engineer (Each 50%).
ARA terminal for Signalling Installation with PBT materials. Inspection by RDSO. 6- Way (ARA terminal) Drg No.SA-23756 Alt3, Specn No. IRS-S-75/2006 (Rev.-2) with latest amd.
Wago / phoneix terminal blocks (Part no.280-874). 4 conductor disconnect terminal block. Inspection by Rep. CSTE/CON/BSP. It includes : (i) 4 conductor disconnect terminal block for test and measurement; 0.08 mm.sq.- 2.5mm.sq., Center marking with slot test for test plug dia 2mm/0.079 In and dia 2.3mm/0.091 in; Carrier rail din 35: front-entry; with knife disconnect large 24 cage clampconnection, grey. (ii) End and intermediate plate, 2.5 Mm/0.394 in wide carrier rail din 35, grey (Wago part no. 249-117)-1700 No. (iii) Screw end stop for carrier rail.-1700 No. (iv) steel carrier rail;35 X 7.5 mm, 1 mm /0.039 in thick; unslotted (Part no. 210-229/PW11-0000).- 200 No. (v) WSB quick marking system; horizontal; 1 ... 10 (10x); for width 5-17.5 Mm; 10 strips of 10 marker per strip (100) per card; consecutive numbers white (Part no. 209 - 502S).- 200 No.(vi) Adjacent jumper nominal current 24A; Insulated Grey.-100 No.
Key Lock 'E' type with key Drg.No.SA-3376/M. Alt-2. Spec.No.IRS-S-30/64 different ward. Inspection by Rep. of Railway Engineer.
Key Lock Relay working with 24 V DC Non ACI type 4F/4B, Spec. no. IRS: S-23, IRS:S- 34 & IRS: S-46. Inspection by RDSO.
Block Bell equipment complete as per Drg. No. TCA-15080 (Adv) Alt-1 & specn. No. IRS-TC-44/88 with latest amendment. Inspection by Rep. of Railway Engineer.
Filter unit as per Drg. No. TCA-20080 & Specn No.IRS: S68/89 with latest amendment. Inspection by RDSO.
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer. (a) Chair Model PCH-5001T(Revolving) or latest. Make: Godrej.
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer. (b) Table of Godrej make. Model No. WT 718 + ERU or latest.
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer. (c) Wooden stool height 2 feet.
Supply of the following furnitures for SM / relay room. Inspection by Rep. of Railway Engineer. (d) 2 drawer filling cabinet STVFXDM 2086 or latest. Make: Godrej.
Block Instrument Double Line, Lock & Block, 3-pos complete with Telephone, 33 condencer, Induction Coil etc with arrengement for commutator Handle Lock. As per Drawing No. SA-22781(adv) Alt-1. Spec No.IRS-S-22-91 and IRS-S- 23.2 Nos with circular gong as per Dwawing No. SA-22912. Inspection by RDSO.
Supply of clip on meter AC/DC with carrying case make Fluke or similar with standard accessories along with engineering and operating manual. Inspection by Rep. of Railway Engineer.
Supply of disitilled water plant/Demineralised palnt of (10-50-100 liter per hour) make Laptech/shivam or indicated by Railways. Inspection by Rep. of Railway Engineer.
20 pair CT Box. Inspection by Rep. of Railway Engineer.
Flasher & Hooter for LC gates (1 set shall comprise for 1 level crossing). Inspection by Rep. of Railway Engineer. Above/
B3-Supply of Electrical & Electronics materials 34776769.00 Below/P
Relay, Non-AC Immune, plug-in type, Style "QN1", Neutral line, 2 4 V D C 12F.4B 1 contacts, front a n d back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:930, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABCDE. Inspection by RDSO.
Relay, Non-AC Immune, plug-in type, Style "QN1', Neutral line, 24V DC 8F.8B 2 contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:930, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABCDF. Inspection by RDSO.
Relay, AC Immune, plug-in type, Style "QNAI', Neutral line, 24V DC 12F.4B contacts, 3 front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABDFH . Inspection by RDSO.
Relay, AC Immune, plug-in type, Style "QNAI'', Neutral line, 24V DC 8F.8B contacts, 4 front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23.The interlocking code for this unit shall be ABDGH. Inspection by RDSO.
Relay AC immune Plug in type Style 'QNNA1, twin neutral line, 24VDC 6F/2B contacts 5 each for LH and RH, front and back contact metal to carbon , complete with plug board, retaining clips and connectors conforming to BRS:960,IRS:S 60, IRS:S 34 & IRS:S 23. Interlocking code of this unit shall be CDEHX. Inspection by RDSO.
Relay AC immune Plug in type Style 'QNNA1', twin neutral line, 24VDC 4F/4B contacts 6 each for LH and RH, front and back contact metal to carbon , complete with plug board, retaining clips and connectors conforming to BRS:960,IRS:S 60, IRS:S 34 & IRS:S 23. Interlocking code of this unit shall be ACDHJ. Inspection by RDSO.
Relay Plug in type Style 'QL1', Magnetically latched neutral line, 24VDC 11F/4B 7 contacts each, front and back contact metal to carbon , complete with plug board, retaining clips and connectors conforming to BRS:935A, IRS:S 34 & IRS:S 23. Interlocking code of this unit shall be ABDEG. Inspection by RDSO.
Relay, AC Immune, plug-in type, Style 'QSPA1', Neutral line, slow to pickup, 24V DC, 8 8F.4B contacts, front and back contacts metal to carbon, complete with plug board, retaining clip & connectors conforming to BRS:933A, IRS:S 60, IRS:S 34 & IRS:S 23. The interlocking code for this unit shall be ABDEJ. Inspection by RDSO.
Relay Non- AC Immune, Plug in type, style 'QNN1', twin neutral line, 24V DC, 4F/4B 9 contacts, each for LH & RH, front & back contacts metal to carbon, complete with plug board, retaining clips and connectors, conforming to BRS: 960, IRS: S 34 & IRS : S23. The interlocking code for this unit shall be ACEHJ. Inspection by RDSO.
Relay Non- AC Immune, Plug in type, style 'QNN1', twin neutral line, 24V DC, 6F/2B 10 contacts, each for LH & RH, front & back contacts metal t o carbon, complete w ith plug board, retaining clips and connectors, conforming to BRS: 960, IRS: S 34 & IRS : S23.The interlocking code for this unit shall be ACDEK. Inspection by RDSO.
Universal relay, plug in type, style AC/LED all aspects AC lamp proving relay unit with 11 in built current transformer type, slow release neutral line relay 4F/4B contacts, front a n d back contacts metal to carbon, shall be suitable for working in series with the 110AC LED signal lamp rated at 15W conforming to RDSO specn. no. BRS:941A , STS/E/RELAYS/AC LIT/LED Signal/09-2002, Amdt-1 with latest. Inspection by RDSO.
Relay, A C Immune, plug-in type, Style "QNA1K", Neutral line, 2 4 V D C 1000 ohms 12 6F.6B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 & RDSO Spec. no. STS/E/Relay/UEA(PI). The interlocking code for this unit shall be CDEKY. Inspection by RDSO.
Relay AC Immune, plug in type, STYLE QBAT, DC Biased track, 9 Ohms, 2F-2B, 13 Contacts, front and back contacts metal to carbon complete with plug -board, retaining clip and connectors conforming to RDSO/SPN/84-88, IRS:S 34 & IRSS:23. The interlocking code for for this unit shall be ABEJX. Inspection by RDSO.
Relay Flasher, (Anuvidyuat make or Similar) Electronic solid state input 24V. DC at 40/60 flashes per minute.Specification No.RDSO/SPN/173/2002. Inspection by Rep. of Railway Engineer.
Timer Relay Fail safe type of electronic time delay device - 24 Volt DC (Anuvidyuat 15 make or similar) for Rly. Signalling as per Spec. No. IRS:S-61/2000 with latest amendment. The interlocking code pin for this unit shall be AFGKY. (with a time setting of 120 seconds). Inspection by RDSO.
Relay DC Polarised 3-Position 77 Ohm. 1N/1R contacts metal to metal, centre biased armature. IRS:S-31-80,(Rev) IRS:S:34 & IRS:S:23. Inspection by RDSO.
Electronic Magneto telephone desk type to Specn No.IRS-TC-79/2000. Inspection by Rep. of Railway Engineer.
(a) Supply of datalogger system for Railway S&T installation as per RDSO specification no. IRS:S-99/2006 (ammedent - 3) or latest with -(i) Digital Input 512, Analog Input 64. Inspection by RDSO.
(i) Installation, wiring, testing and commissioning of Digital Input 512, Analog Input 64 datalogger system as per RDSO specification no. IRS:S-99/2006 (ammedent - 3 ) o r latest including 19 networking a n d central monitoring along w i t h installation of remote monitoring software and hardware. The contractor is also required to list out the no. of analog & digital inputs for wiring & operation of the datalogger by taking approval of the Rly. for those inputs. This includes training to 4 staffs at site.
Supply of datalogger system for Railway S&T installation as per RDSO specification no. IRS:S-99/2006 (ammedent - 3) or latest with - Digital Input 1024, Analog Input 64. Inspection by RDSO.
Installation, wiring, testing and commissioning of Digital Input 1024, Analog Input 64 datalogger system as per RDSO specification no. IRS:S-99/2006 (ammedent - 3 ) o r latest including 21 networking a n d central monitoring along w i t h installation of remote monitoring software and hardware. The contractor is also required to list out the no. of analog & digital inputs for wiring & operation of the datalogger by taking approval of the Rly. for those inputs. This includes training to 4 staff at site.
Supply of External leased line modem as per RDSO specition no. IRS:S-99/2006 amadt-3 or latest.. Inspection by RDSO. 1028577.0
(a) Supply of block proving with Digital Axle Counter as per RDSO spec. no. IRS: S - 105/2012 or latest using UFSBI & Block panel for single line operation. Inspection by RDSO. Note:- 23 The above consisting of following :- For Single line (1)Universal fail safe block interface as per RDSO Specn no.RDSO/SPN/147/2005(Latest ammendments)- 2 nos. (2)SM's Panel (RDSO/S/32019 tentative- 2 nos. (3)Relay Rack with locking and sealing arrangement duly wired(as per RDSO/S/32020 -tentative)- 2 nos. (4) Relays:- QN1- 44 nos.,QNA1-12 nos. QL1- 4 nos. Timer- 2 nos. (5) Block Telephone- 2 nos.
(b) Transportation, Installation, testing and commissioning of block proving with DAC using UFSBI & Block panel complete set as mentioned above.
(c) Supply of Automatic Media changeover of UFSBI working on redundant channels for data transmission on OFC/ Quad. Inspection by Rep. of Railway Engineer.
Supply of Modem compatible with existing UFSBI system(for secondary/back up media) along with class D /Type III SPD for communication line(2 wire Tx & 2 wire Rx) to UFSBI for different surges. Make:- OBO Betterman/ CITEL or similar. Inspection by Rep. of Railway Engineer.
Installation, testing and commissioning of Automatic Media changeover Modern for use with secondary/back up media.
(A)Earthing and bonding system as per RDSO Spec. No. RDSO/SPN/197/2008, RDSO Drg. No. SDO/RDSO/E&B/001 dt. 19.09.08 and RDSO Drg. N o . SDO/RDSO/E&B/002 d t . 19.09.08. Earthing and bonding system for Relay Room , IPS Room ,SPD Box, Operator panel in SM's room, signalling equipments in Station building, Block circuit, SSDAC,etc. Inspection by RDSO. Supply of 28 permanent maintance, (i) 17 mm diameter and minimum 3 m long Copper Bonded Steel Rod - 1 Nos, (ii) GEM- 25 lb - 3 Bags, (iii) 25*6*150 mm Cu Bus Bar- 2 No, (iv) Cu lugs and nut bolt 2 nos, (v) Supply for Connection between Earthpits and MEBB It includes 35 sq mm multi-strand pvc insulated single core Cu cable (15 mtr Lump Sum). (vi) Supply for Internal connection from MEBB To SEBB and to other equipments.(50 mtr Lump Sum).It includes 16 sq mm and 10 sq mm multi strand pvc insulated single core Cu cable.
(B) Installation, testing and commissioning of Permanent and Maintenance Free Earth 29 pits. Installation charges : Earthpit (1 Set) It includes,(i) Civil works related to earth pit digging, PMF earth pit installation,,backfilling and chamber making. (ii) Materials for chamber including Chamber Cover.
(a) Supply of protocol converter to suit with the dataloggers of the station. Inspection by Rep. of Railway Engineer
(b) Installation and wiring of protocol converter to suit with the dataloggers of the station .
Control Panel f o r M i d section interlocked L C Gate/IBS(operation-cum indication console Domino type)/ Siding motor operated point operation pannel /Non Interlocking pannel to RDSO Spec. No. 36/87 size of each domino will be 54+10mm X 34+7mm. 25% panel LEDs, all type 32 of dominos and buttons assemblies compleate as spare to be supplied. This includes cable termination MS rack with 3/4" thick wood strips including fabrication thereof as per the requirement of the Rly. terminations of cables, fix of terminal blocks, terminals, painting and lettering as required. Inspection by Rep. of Railway Engineer. Note:- MS angle/flat, teak wood, bolts & nuts, screws, shelves etc. required as above shall be supplied by the contractor.
Supply o f D o o r Proximity switches a l o n g w i t h 2 w a y r i g i d connector f o r wire termination between proximity switches and Datalogger Tag blocks as per specs. Inspection by Rep. of Railway Engineer.
Supply of Tool Kit for Multi Section Digital Axle Counter. Inspection by Rep. of Railway Engineer. (a) Fluke 289 or latest Digital multimeter of for MSDAC system with Probe set = One no. (b) Torque wrenches 25-135 N/Mtr (c) Set of Spanners Screw driver and soldering iron suitable for MSDAC. (d) Dummy wheel (e) Marking Jig (f) Adapter Card (g) DAC EC Card Puller (h) Micro procceser based portable data analyser for down loading Event logger data for analysis and report generation for Digital Axle counter Model with (a) CPO-Intel Centrino Duo Moblie Technology with Intel Core 2 DUO Processor T 7200 or better 2 GHz, 4 MB L2 Cache of better. (b) Mother Board- Intel 945 GM/PM 34 Chipest. (c) Operating system- Preload with Vista Bussiness and free open Software.(d) Proccesar/Memory/System Bus- 667 MHz FSB or better,(e) Main Memory- DDR2-667 MHz (f) optical Drive-Intenal 8XDVD+/- RW Combination D r i v e (SuperMulti ) w i t h dual layer write and read capabilities o r better w ith software, (g) Graphics Accelerator - Intel (R) Media Accelerator-950 Graphics:Upto 224 MB shared system memory, resolution 2048 X 1536, (h) Display- 15.4" TFT WXGA Display (1280 X 800 resolution) (i) Interfaces-IEEE 1394 integrated port (10/100/1000); 4* USB PORT + 1* Powered USB (D-Bay), 1 * serial port RJ45 Ethernate port,RJ11 Morden port; external VGA port;Video: 15-pin moniter connector, Componet Video & Audio jacks;Built in Microphone;Bluetooth 2.0, (j) Wireless LAN - Intel (r) PRO /Wireless 3945.Network Connection 802.11 a/g Wi-Fi enabled., (k) Modem Internal 56 kbps or better,
Relay , Non-AC Immune, plug-in type, style "QS3", Neutral line, tractive armature, 12 35 V DC , 1000 ohm 4F.4B contacts, front contacts metal to carbon and back contacts metal / carbon, complete with plug board, retaining clip & connectors conforming to BRS: 930A, IRS: S 34 & IRS: S 23. The interlocking code pin for this unit shall be CDEKX. Inspection by RDSO.
Supply of VF tapping termination transformer to specification IRS-TC-22/76 for 470:1120, Inspection by Rep. of Railway Engineer.
(a) Supply of fuse indication cum monitoring and automatic changeover system as per 37 RDSO specification no. RDSO/SPN/209/2012 Rev. 0 or latest. The system shall be supplied along with all standby fuses placed in the system. In addition to it, spare quantity of 100% fuses of each type shall also be supplied along with the system. Inspection by RDSO. For 32 fuses per set (Upto 4 Amps):-
(b) Transportation, installation, testing & commissioning of fuse indication cum monitoring and automatic changeover system as mentioned above.
(a) Supply of Earth Leakage Detector (12 nos. channel) as per RDSO specification no. 39 RDSO/SPN/256/2002 or latest having 6 digit counter, 12 Channel bus bar voltage of 110 V / 60 V / 12 V in AC DC measurement in 19" sub rack along with insulation resistance meter, remote indication & buzzer in ASM room at station of Bilaspur/Raipur/Nagpur Division. The tenderer should submit three years warranty certificate along with supply of material. Inspection by RDSO.
(b) Transportation, installation, testing & commissioning of Earth Leakage Detector as mentioned above.
Supply Fire Alarm System of Microprocessor based intelligent, addressable, modular, 1 loop (minimum 125 detector/devices per loop- expandable to 2 loops) Fire Alarm Control Panel with LCD display with 320 Character with soft keys for displaying alarm, events and operating functions, Day/ Night operation function, Remote maintenance service feature etc. The panel should be multi- protocol ie able to support at least 2 additional different makes of addressable detectors. The panel 41 should have minimum two relay outputs & 1 Monitored Sounder Output. It should have provision to be connected to repeater panels in future. The panel shall capable to operate on 240 volts AC power supply, automatic battery charger, 24 volts, sealed lead acid maintenance free batteries sufficient for 2 4 hours normal working and then be capable of operating the system for 30 minutes during emergency condition as per detailed specifications complete as required. Panel Should Be VdS/UL/FM/EN/LPCB Certified as per RDSO Specification No. RDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by RDSO. Annexure: E
Supply of Analogue Addressable Multisensor Detector with multiple sensitivity( 42 adjustable at site) levels , programmable for timed automatic sensitivity selection with base, and other accessories as required and Detectors shall be dS/UL/FM/EN/LPCB listed. The Detectors shall comply to the RDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by RDSO.
Supply of Manual call points, Push type & resettable with key, with In-built isolator. Shall be VdS/UL/FM/EN/LPCB compliant and shall comply to the RDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by RDSO.
Supply of Output Module which will provide potential free (NO/NC) contact to existing 44 Data Logger. Complying to the RDSO/SPN/217/2025 Ver-3.1 or latest. Note:- The contractor will provide potential free contact for goomty and Relay Room only. The connectivity with existing data logger will be done by Railway. Inspection by RDSO.
Supply of Hooter cum Strobe complying to the RDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by RDSO.
Supply of i s o l a t o r d e v i c e s f o r e v e r y 2 0 d e t e c t o r s , c o m p l y i n g t o the RDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by RDSO.
Installation, Testing and commissioning of all above items as per requirement at site. The work will execute as per instruction of representative of Railway Engineer.
Supply of 2C 1.5 sq mm twisted shielded armoured copper cable. Inspection by Rep. of Railway Engineer.
Electrically operated lifting barrier complete as per RDSO SPN no. 208/2012 Ver-2 with 49 latest Amendment, operating voltage 110V AC,without hand generator, length of the boom is 9.76 meter / 32 feet . Inspection by RDSO.Note:- Spare shall also be supplied as per RDSO specifications (rates for them are included above).
Supply of Remote terminal unit with 128 digital & 16 analog inputs with modem as per RDSO spec. no - IRS-S- 99/2006 or latest. Inspection by Rep. of RDSO.
Installation, Wiring, Testing and commissioning of Remote terminal unit with 128 digital & 16 analog inputs with modem as per RDSO spec. no - IRS-S- 99/2006 or latest.
Supply of fault analysis software for RTUs.The work to be executed as per directives of the Repr. of CSTE/Con. Inspection by Rep. of Railway Engineer. Above/
NS1-Non-SOR(SUPPLY & EXECUTION OF SIGNALLING & TELECOM
Supply of PVC flexible cable Multistrand wire Copper conductors cross section 25 Sq.mm x 1Core as per RDSO specification No. IRS:76/89 with latest Amendment if any Inspection by Rep. of Railway Engineer. (RED AND BLACK 50% EACH).
Supply of Digital Insulation Tester, Voltage-Multirange (100/250/500/1000VDC), Insulation Resistance: 10KOhms to 999MOhms Make: RISHABH or similar. Inspection by representative of Railway Engineer.
Supply of SMPS based battery chargers for telecom use 48 volts, 25 Amps in n+2 3 configuration modules of 25 Amps each with automatic switching between the modules as per RDSO Specification no. RDSO/SPN/TL/23/99/V4 (with latest amendment) along with two potential free contacts for monitoring AC/DC failure through EMS . Amaraja or Statcon make. Inspection by RDSO.
Supply of maintenance console (PC & printer) with one set of table and chair for datalogger/RTU for online tracking and monitoring of station position as per "annexure B " enclosed. Inspection by Rep. of Railway Engineer.
Relay, AC Immune, plug-in type, Style 'QTA2 realy; DC Neutral track relay, 9 ohm, 5 2F.1B contacts, front and back contacts metal to carbon, complete with plug-board, retaining clip and connectors conforming to BRS:939A,BRS:966 (Appendix F2), IRS:S 34 & IRS:S 23. Inspection by RDSO.
Goods, Supply of Integrated smoke and heat detector tester with smoke chamber cleaning features SHT-001, containing following accessories -sensor unit-1, Battery rod-1, Injector-1, mist liquid-1, charger-1, connect rod-4. Specifications as per annexure attached. 1261656.0
Supply, Installation and commissioning of Block proving by Axle Counter [BPAC] using block panel and UFSBI for Double line operation as per RDSO Spec. No: IRS- 105/2012 [VER.0] with latest version and amdt. Inspection by RDSO.Each set consisting of the following: 1. Universal fail 7 safe block interface complete with all accessories as per RDSO Spec No: IRS- S104/212[VER.0] with latest version & Amdt-Qty-02 Nos. 2. Block Panel complete with all accessories as per RDSO Drg. No. RDSO/S/32017[latest amdts] Qty -02 Nos. 3. Relay Rack duly wired with due locking and sealing arrangement as per RDSO Drg. No. RDSO/S/32018 including relays for each Relay Rack [QN1-19 No's, QNA1-07 No's, QL1-02 Nos, and Timers -01No]-Qty 2 Nos. 4. Block Telephone with accessories as per RDSO specificaton.
Transportation, Installation, testing and commissioning of block proving with DAC using UFSBI & Block panel complete set as mentioned above.
Supply of Automatic Media changeover of UFSBI working on redundant channels for data transmission on OFC/ Quad. Inspection by Rep. of Railway Engineer.
Supply of Modem compatible with existing UFSBI system (for secondary/back up media) along with class D /Type III SPD for communication line (2 wire Tx & 2 wire Rx) to UFSBI for different surges. Make:- OBO Betterman/ CITEL or similar. Inspection by Rep. of Railway Engineer.
Installation, testing and commissioning of Automatic Media changeover Modem for use with secondary/back up media.
Allied Products &Accessories. (iv)Supply of Smart Earth Monitoring Systemwhich can offer realtime monitoring ofresistance remotely.The system shall allowcontinuous andimmediate surveillanceof resistance levels,providing valuable alertinsights andinformation data fromvarious locations, inreal time without theneed for physicalpresence.Inspection-RITES.
Auto changeover panel for colour light signalling supply of 63 Amp as per RDSO specn. PI/SPC/PSI/CLS/0021 including 'A' & 'C' sheet no. 1. Matrix make or similar Inspection by Rep. Of Railway Engineer.
Installation, cable termination, wiring, testing and commissioning of Auto Changeover panel.
Supply of 65" UHD LED display as per Technical specification on Annexure "G". Make: Panasonic, Hyundai, Sony or Samsung. Inspection by representative of CSTE/Con/BSP.
Supply of HP OmniStudio X All-in-One 32"-c0015 in Desktop PC model or latest
Supply of Brother MFC-T4500DW A3 Inkjet color printer model or similar. 1425086.0
Supply of GNSS based cable route tracer kit with receiver with built in mount for GNSS receiver, 12W or higher power transmitter with >= 130V Voltage boost, suitable for detecting & mapping underground cables with accuracy up to 2 5 cm, with current direction up/down arrows. 18 Supply shall include locating receiver with RTK receiver powered by locator receiver, transmitter, compatible dual Bluetooth android phone, mobile application pre-installed in android device with 5 years subscription & PC database software access for direct map generation & download including depth data, 5 years subscription for GNSS correction service & standard accessories, per specification attached. Make/Model: Rycom Pathfinder PLDL Route locator with Trimble DA2 GNSS receiver or similar. Detailed specification as per Annexure-II. Inspection by RITES.
Supply of Fire Extinguisher CO2 type (capacity minimum 4.5Kg. Or more ) with IS marked complying to the specification No. RDSO/SPN/217/2018 Ver.2.0 or latest. Insp. By Rep. from CSTE/Con/BSP.
Earthing and bonding system as per RDSO Spec. No. RDSO/SPN/197/2017 Ver.1 , RDSO Drg. No.RSDO/RDSO/E&B/001 dt. 19.09.08 and RDSO Drg. No. SDO/RDSO/E&B/002 dt. 19.09.08. Earthing and bonding system for OFC room/FP/SSP etc. Inspection by RDSO. (a) Supply of "Permanent and Maintenance Free Earth pits materials".1 Set PMF earth pit consisting of:- (i) 17 mm diameter and minimum 3 m long Copper Bonded Steel Rod- 3 Nos. (ii) GEM- 25 lb- 9 Bags (iii) 25*6*200 mm Cu bus bar ( At Electrode) - 3 No. (iv) 25*6*300 mm Cu Bus Bar ( MEBB) - 1 No (v) 20 25*6*150 mm Cu Bus Bar (SEBB) - 3 Nos . (b) Supply for Interconnection of earthpits Copper Earth Tape of 25 x 2 mm (lump Sum 10 meter) (c) Supply for Connection between Earthpits and MEBB It includes 35 sq mm multi-strand pvc insulated single core Cu cable (15 mtr Lump Sum). (d) Supply for Internal connection from MEBB To SEBB and to other equipments.(50 mtr Lump Sum). It includes 16 sq mm and 10 sq mm pvc insulated single core Cu cable. (e) Cad weld Joints ( Exo thermic welding):- (i) For interconnection between earth pits - 3 Nos LS), (ii) Joint between Cu tape & electrode- 1 No LS, (iii) Connection between electrode to MEBB - 4 Nos LS, (iv) Between MEBB TO SEBB - 6 Nos LS, (f) Supply of fixing accessories as Cu lugs & steel nuts -bolts. 50 Nos. LS.
Installation, testing and commissioning of Permanent and Maintenance Free Earth pits .(For Copper Bonded Steel Rod- 3 Nos). Installation charges : Earthpit (1 Set) It includes, (i) Civil 21 works related to earth pit digging, PMF earth pit installation,,backfilling and chamber making. (ii) Mateials for chamber including Chamber Cover. (iii) Drilling and fixing of MEBB & SEBB (iv) Installation for interconnection:- It includes civil work for 2 ft. depth x 1 ft.width trench digging and backfilling with GEM & Black soil. ( 10 mtr lump sum).
Supply of Class A protection as per RDSO Drg. Circulated vide letter no. STS/L/SSI/CA/US&S dated 26.07.2011 or Latest.
Supply of ferrules of different colour, printing termination details / Functions in 23 different colours as per Railway specification and installation in Relay room, Location Box and Power board etc, at various stations and LC gates as per instruction of Engg. in charge. All materials required for the work shall be supplied by the contractor.
Supply of Earthing arrangement for EI system 'as per RDSO drawing for earthing & Bonding scheme for EI as per RDSO TAN no. STS/E/TAN/3006 VER_3.1 DATED. 25.06.2025 or Latest.'Inspection by RDSO. Here Job unit stands for Locations.
Supply of GUI software to monitor health of detector and other devices. The software 25 shall be accessible over TCP/IP. IT shall also be able to indicate in the device whenever the detector or the device would require to be Services as per RDSO/SPN/217/2025 Ver-3.1 or latest Inspection by RDSO.
Installation, wiring, testing and commissioning of Automatic Media changeover Modem for use with secondary/back up media.
Installation, wiring, testing and commissioning of "Universal fail Safe Block Interface" to interface suitable for IBS, Direction panel etc.
Supply of Dual redudent arrangement of UFSBI electronics for exchange of vital relay 28 state exchange pertaining to IB signalling, etc. The system comparises of following sub systems: (a) Supply of electronics for UFSBI interface as per IRS spec. no. IRS:S-104/2012 ver. 0 (latest ammendement). Inspection by RDSO.
Supply of Dual redudent arrangement of UFSBI electronics for exchange of vital relay 29 state exchange pertaining to IB signalling, etc. The system comparises of following sub systems: (b) Supply of Automatic Media changeover of modem working on redudent channels for data transmission on OFC/Quad. Inspection by RDSO.
Supply of Dual redudent arrangement of UFSBI electronics for exchange of vital relay 30 state exchange pertaining to IB signalling, etc. The system comparises of following sub systems: (c) Supply of Modem for UFSBI (for use of secondary media OFC/Quad). Railway shall define Secondary media before placing of order. Inspection by representative of CSTE/Con/BSP.
Supply of Dual redudent arrangement of UFSBI electronics for exchange of vital relay state exchange pertaining to IB signalling, etc. The system comparises of following sub systems: (d) 31 Supply of Pre wired 36-U floor mounting MS cabinet suited to fit 2 sets of UFSBI electronics with Siemens grey/smoke grey powder coated(rust proof and long life), tinted 3-4 mm thick tinted acrylic/polycarbonate/glass sheet fitted on front door and metal back door, with double lock and bottom cable entery facility, suitable for fitting one pair of each items (a, b & c) above Inspection by representative of CSTE/Con/BSP.
Multistrand 35 sq mm wire signal core cable Red/Black/green IS 694 (25% red, 25% black & 50% green)Inspection by representative of CSTE/Con/BSP.
PVC Insulated Multicore copper cable as per IRS S76/89 -60 core*1 mm Dia. Inspection by RDSO.
Relay AC Immune, Plug-in type, Style - QBCA1 DC biased point contractor, 24V DC, 34 2F(HD)-4B contacts. Front contacts(heavy dudty) and Back contacts metal to carbon, complete with plug board, retaining clip and connectors with latest amendment conforming to BRS: 943, IRS: S 34 & IRS: S 23. The interlocking code for this unit shall be BCEJK. Inspection by RDSO.
Supply of 24F fully loaded FMS to suit EI system (Complete with 24 nos. 0db adaptor and 24 nos. 1m length Pigtails and 6 nos. 1m Pigtail on spare. All are "SC" type connectors). Inspection by Rep. of Railway Engineer.
Supply, transportation, installation, testing and commissioning of Media Converter Make:- MROTEK (FCAT01)/ZYXEL with one 100 Mbps fiber port (SC Connector duplex) supporting 36 single mode fiber driving distance up to 15 Kms and one 10/100 Mbps Ethernet port, unit supplied with built AC 230V AC power supply; Unit to support link fault pass through feature for fiber cuts to be prograted to copper port through dip swithch control feature. Inspection: Representative of CSTE/Con/BSP.
Supply of L-2 POE 24 LAN manageable switch 10/100/1000 base with 02 SFP Port loaded. (Detailspecification attached in Annexure-L).MaterialInspection by Consignee/Rep. of CSTE/Con.
Installation, Testing & Commissioning of L-2 POE 24 LAN manageable switch 10/100/1000 base with 02 SFP Port loaded. The work is to be executed as per the instruction of Railway Engineer.
Supply of loose tube Optical fiber jumper(patch chord) with SC-SC connector to suit EI system.Length of optical fiber jumper (Patch chord) shall be as per site requirement. Inspection by Rep. of Railway Engineer.
Table of Godrej make, Model No. ARISTO/IMPRESS Main Desk with ERU + Pedestal (1800 * 900 *750) or latest. Inspection by representative of railway engineer.
Multistrand 16 sq mm wire signal core cable green IS 694. Inspection by representative of CSTE/Con/BSP.
Transportation, Installation, wiring and commissioning of 48V, 200 AH VRLA battery bank and battery charger at each OFC installations, distribution of AC supply to the charger including 42 Supply of wiring materials, commissioning of AC&DC Power Supply Distribution system including earthing protection arrangement and wiring of Battery Chargers & batteries etc as per manufacturer's instructions and railway's directives. It includes supply of battery rack of approved design, as per site requirement.
Spare card suitable for PUNCOM Mux 2MB programmable Primary Digital Drop Insert MUX Model VMux 100 as per RDSO specification no. IRS-TC-68/2012 or latest. Inspection by RDSO. (c) 2W/4W E&M VF I/f card(4 Circuit/Card).
Spare card suitable for PUNCOM Mux 2MB programmable Primary Digital Drop Insert MUX Model VMux 100 as per RDSO specification no. IRS-TC-68/2012 or latest. Inspection by RDSO. (e) Subscriber I/f card (FXS) (4 Circuit/Card).
Supply of PVC insulated-3/0.7 mm screened twin core copper wire overall PVC jacketing , make:- vmark , usha, techno flex, poly flex or similar. Inspection by representative of CSTE/Con/BSP.
250Watts Audio Amplifire Model SSA- 250DP Ahuja or Similar. Inspection by Rep. of Railway Engineer.
Supply of PA Horn Speaker Make Ahuja AMH-402T or Similar as per Following Spec. 47 Input Power 40W RMS: Power: Power taps: 40/20/10/5W on 100V. Impedence 250/500/1K/2K: Freq. Resp: 120-16000 Hz, SPL at 1 KHZ 98db/40w/1m: 114db/40w/1m: dim W370/H250xD300 mm: AVS (UV protected): Wt 6.5 Kg. Inspection by representative of CSTE/Con/BSP
Supply of cordless Microphone, Make:-Ahuja/Bose/Studiomaster. Inspection by Rep. of CSTE/Con/BSP.
Description:- Supply of 12V 65AH SMF VRLA battery make Exide,Amron or Duracell Inspection by Rep. of Railway Engineer
Supply of E1- Ethernet Interface converter along with 100fx x 4 ports. Make: D Link, Team Engineer or Similar. Material Inspection by Consignee.
Supply, transportation ,instalation ,testing and commisioning of 2Mbps LAN Extender 51 with all accessories 10/100 base t. ports RJ-45 Auto MBI-X, Auto negotiate 10/100 Mbps,RJ-11 Port,Extendering Distance Upto5.5 Kms as per RDSO Draft specification no. RDSO/SPN/TC/82/2013 Rev.1.0 or latest with complete accessories. Make-DAX,D-LINK, MROTEK alongwith three years warranty from the date of supply. Inspection by Representative of CSTE/Con/BSP.
Supply of Optical Power meter(wave length, 1310 nm &1550 nm user selectable ,measering range +3dbm to -60dbm, as per techenical spec. no. GR/OPM 01/03.Jan 5.(Type B) or latest specification. inspected by representative of CSTE/Con/BSP.
Supply of Mini-Optical Time Domain Reflectometer (Type-II) as per latest TEC specification no. G/OTD/02-02 April 2005 (with latest amendment). Make:Yokogawa/Acterna. Inspection by RDSO.
Multistrand 10 sq mm wire signal core cable green IS 694. Inspection by representative of CSTE/Con/BSP.
Compound Bag 11.5kg. Inspection by representative of CSTE/Con/BSP. Here Job stand for Bag.
Provision of double bonding wire by drilling suitable holes as directed by site Engineer with contractor's materials such as channel pin, GI wire & other misc. Items as required at site.
Disconnection of track lead wire & double bonding wire during Engg. track renewal/ Machine work and reconnection of the same after completion of Engg. work.
Stainless steel stand for Visual Display Unit for Electronic Interlocking. Inspection by Rep. of CSTE/CON/BSP.
S u p p l y of workspace make new modular control desk or similar for 2 monitors(minimum 54 " or higher size), 2 operators and 1 module will be provided for storage make in SLAT system with side drawer. (i) Desktop made of 12 mm ASS + 25 MM MDF with properties like - high scratch resistances, seamiess joint, flammbillity class A, non-porous, (ii) structure- powder 59 coated alluminium sturty structure and extreme side aesthetic legs, (iii) shutter- 18 mm MDF, (iv) proper cooling aggregement for CPU cabinet, (v) side out CPU tray, (vi) ergonomic design considering proper leg space, (vii) all electrical components as shown in drawing, other details shall be executed as advised by Railway representative. (A tentative sketch is enclosed at annexure-F, however actual drawing shall be supplied as per site requirement.) Inspection by Rep. of CSTE/CON/BSP.
Transportation, installation & commissioning of workspace make new modular control desk.
Supply, Installation, Testing & commissioning of Resettable Analogue Type Linear Heat Sensing (LHS) Cable complying to RRDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by representative of railway engineer.
Supply, Installation, Testing & commissioning of Resettable Analogue Type Linear Heat Sensing(LHS) Cable Interface Module with all accessories for single strech complying to RDSO/SPN/217/2025 Ver-3.1 or latest. Inspection by RDSO.
Supply, Installation, Testing & Commissioning of Aspiration Type Smoke Detector as per RDSO specification RDSO SPN/217/2021 ver.3.0 or latest. This should be compatible with existing RDSO type fire alarmto be installed at station.
CPVC Pipe as per RDSO specification RDSO SPN/217/2021 ver.2.0 or latest. Square
Supply and fixing of flex printing for different type of plan etc.(star flex, high quality with board) or as advised by Railway's Representative. Inspection by Rep. of CSTE/CON/BSP.
Supply, installation testing commisssioing of 2X1.5 sqmm Fire survival flexible/Un- 66 armoured cable. Un-armoured cables should meet fire performance test under simultaneous action of Flame, water stress and impacts on single sample at 950°C for minimum 2 hours, certified by UL or FM or Vds or LPCB or BRE Global or any recognized lab by Government of India and shall comply to RDSO/SPN/217/2025 ver 3.1 or latest.Inspection by RDSO.
Air TerminationNetwork. (vii) Supply of Universal Connector for making straight, Tee & Cross joint of 8mm AluminiumConductor to 8 mm dia Aluminium conductoron parapet wall, roofand vertical facade ofmasonery / glass /metallicwork.Inspection- RITES.
Down Conductor. (iii)Supply of Test Clampto disconnect the downconductor from 68 theearth terminationnetwork for regularchecks of the earthtermination resistancevalue which shall be ofStainless steel andsuitable for connecting8 mm aluminium roundconductor to 25x2mmCopper conductor (withenclosure). It shallmeet the requirementsof IEC 62561-2.Inspection- RITES.
Earth TerminationNetwork. (ii) Supply of 25x2mm Copper Strip laid at below the ground, as Required and as per specification and code of practice.Inspection- RITES "
Earth TerminationNetwork. (iii)Supply of UL Listed WeldingMaterial for 2DT Exothermic joint Between 25 x 2mm Horizontally laid Copper Strip to 25 x2mm Horizontally laidCopper Strip.Inspection- RITES.
Earth TerminationNetwork. (iv) Supply of UL Listed WeldingMaterial for Straight Exothermic joint Between 25 x 2 mm Horizontally laid Copper Strip to 25 x2mm Horizontally laid Copper Strip.Inspection- RITES.
Earth TerminationNetwork. (v) Supply ofUL Listed WeldingMaterial for Exothermic T joint Between 25 x2mm Horizontally laidCopper Strip to 200 x25 x 6mm Copper BusBar. Inspection- RITES.
Surge ProtectionDevice. (i) SupplyInstallation,commissioning of ClassC SPD 110 V 73 AC,pluggable, withmechanical indicationand potential freecontacts, The supplied SPDs Shall have certification (CERTIFICATEATTACHED) of IECStandard-- National/International Labs likeCE/KEMA/EAC/UL/NABLor any other accredited test lab Inspection.Inspection- RITES.
Surge ProtectionDevice. (ii) SupplyInstallation,commissioning of Class C SPD 110 V 74 DC,pluggable, withmechanical indicationand potential freecontacts, The supplied SPDs Shall havecertification(CERTIFICATEATTACHED) of IECStandard-- National/International Labs likeCE/KEMA/EAC/UL/NABLor any other accreditedtest lab Inspection .Inspection- RITES.
Surge ProtectionDevice. (v) SupplyInstallation,commissioning of ClassC SPD 12V 75 DC,pluggable, withmechanical indicationand potential freecontacts, The suppliedSPDs Shall havecertification(CERTIFICATEATTACHED) of IECStandard-- National/International Labs like CE/KEMA/EAC/UL/NABLor any other accreditedtest lab Inspection .Inspection- RITES.
Surge ProtectionDevice. (vi) SupplyInstallation,commissioning of ClassC SPD 24V 76 DC,pluggable, withmechanical indicationand potential freecontacts, The suppliedSPDs Shall havecertification(CERTIFICATEATTACHED) of IECStandard-- National/International Labs likeCE/KEMA/EAC/UL/NABLor any other accreditedtest lab Inspection .Inspection- RITES.
Surge ProtectionDevice. (vii) SupplyInstallation,commissioning of ClassD SPD 12V 77 datalineSPD , pluggable, withmechanical indicationand potential freecontacts, The suppliedSPDs Shall havecertification(CERTIFICATEATTACHED) of IECStandard-- National/International Labs likeCE/KEMA/EAC/UL/NABLor any other accreditedtest lab Inspection .Inspection- RITES.
Allied Products &Accessories. (i) Supplyof Surge ProtectiveDevice (SPD) LifeTester, 78 designed for on-site testing of SurgeProtection devices. Itallows checking andindicating the healthstatus of GDT/MOVBased SPD of voltagerange up to 1000V. Itshall indicate the statusof SPD by measuringits electricalparameters.Inspection-RITES.
Allied Products &Accessories. (ii) Supply& Installation of Remote monitoring of SPD through aCentralized Monitoring System with followingfeatures: 1. Easyremote monitoring ofthe health of SPD's in ablock section at singlelocation.Inspection-RITES.
Allied Products &Accessories. (iii)Supply & Installation of Isolating spark Gap forlightning equi-potentialbonding of differentearth grids accordingto IEC 62561 part-3 at100kA impulse current,IP 68, fire retardantenclosure.Inspection-RITES. Above/
NS2-Non SOR(Supply of Cables, IPS, SSDAC/MSDAC, 6QD-ERS, Auto-SAT
Supply of Microcontroller based Quad Cable Conductor's Earth Resistance Sensing 1 Unit, for 24 nos. conductors with metering facility for one conductor at a time Inspection authority RITES.
Installation of Microcontroller based Quad Cable Conductor's Earth Resistance Sensing Unit for 24 nos. conductors with metering facility for one conductor at a time. 1350000.0
Performing of SAT at station with the installation of Simulation Panel/IO Controller with the provision of MUX/DEMUX interface equipments from single centralised location for station having up to 2 Goomties and one Central EI, all IO simulation panel wiring will be done by the agency to make the system. ready & functional for complete SAT testing. System shall be deployed till 3 commissiong of the station for a period not more than 30 days after completion of SAT. The final SAT reports shall be checked & signed by the representatives of OEM holding IRSTE / IRSTELO License. Once the SAT is taken up, it shall be completed in one go without any discontinuty. All kind of validation test of the Input Out put Bits for ensuring correct testing to be done by the agency. Responsible site engineer is to be deputed during SAT testing at Site to facilitate and to operate the Equipments and generation of documents records etc.[Payment pecentage: (a). On completion of RCC and Miscellenious Testing: 80% and (b). On commissining: 20%] 1399288.0
INTEGRATED POWER SUPPLY (IPS) major Integrated Power Supply for Distributed EI in 3rd/4th line auto section in RE area as per RDSO Specification No. RDSO/SPN/165/2012(Ver.3.01) 4 with latest amendment, with low maintenance secondary cell (110,200AHx2) as per specification no. IRS: S-88/2004, with latest amendment, without wooden stand for battery. Capacity of different modules and secondary cell should be as per attached IPS Drawing (SECR typical IPS Drawing 38/14 Alt-A). Supervision, Installation and commissioning as per RDSO guidelines letter No. STS/E/IPS/Gen, dt. 01.04.2008.Inspection by RDSO. SUPPLY to store of SSE/Signal/Con/Store/BSP 1013066.0
Supply of Mini IntegratedPower supply (Mini IPS)as per SECR Drg. No.Typical 5 diagram/55/16(Drawing enclosed) forworking of auto signalingin the RE area as perRDSO specification No.RDSO/SPN/165/2012(Ver.3.0) or latest with lowmaintenance secondarycell (110V,120AH) x2 sets as per Specs. No. IRS-S-88/2004 with the latestamendment withelectrolyte, surgeprotection Device (inseparate wall mountableSPD Box) along withspares and toolkit as perRDSO specification.Inspection by RDSO.
Transportation, Installation, configuration, testing and commissioning of mini IPS with different modules and charging of batteries & its installation.
Supply of MSDAC complete system (As per annex-A) with all accessories consisting of 7 complete indoor and outdoor equipment including remote diagnostic and monitoring system as per RDSO Specification no. RDSO/SPN/176/2013 Ver. 3 with the latest amendment/ revision of required Track Sections for yard as standby of DC track circuit in station /Block section in either side of Anuppur station. (As per approved SIP):Inspection by RDSO. Here Job unit stands for DP
Design, Transportation, Installation, testing and commissioning of MSDAC complete system (As per annexure A) with all accessories consisting of complete indoor and outdoor 8 equipment including remote diagnostic and monitoring system as per RDSO Specification no. RDSO/SPN/176/2013 Ver. 3 with the latest amendment/revision of required Track Sections for entire yard as standby of DC track circuit in station /Block section in either side of Anuppur station. Here Job unit stands for DP Above/
Modification/Alteration in existing yard El (Electronic Interlocking) as per latest RDSO guidelines/TAN/SECR guidlines &practices as per approved SIP and circuit diagrams. It includes: Design and modification in existing IFC, ALC etc. of Elsystem, modification in the VDU (Video Display Unit), LCP(Local Control panel), CCIP (Control cum Indication Panel)interface, Maintenance terminal, Relay rack wiring, wiring & modification of Data Logger, connecting new racks to earthing& bonding. All the required materials (Interface cards/relays/wiring material/connectors/fuses/communication devices,power supply modules, material for earth connection etc.) shall be provided by the contractor. The work also includes thesupply of modified Selection table, Interface Circuits, logic circuit, VDU/LCP/CCIP diagram etc. It also includes the carrying out all necessory testings i.e., FAT, SAT (if applicable) etc. jointly with Railways and satisfactory commissioning. Allplans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 02 sets of papercopies anlog with tracing paper to be supplied. Calculation of routes will be done as per Annex-A. (a) Alterations involving modification in up to 10 routes.
Modification/Alteration in existing yard El (Electronic Interlocking) as per latest RDSO guidelines/TAN/SECR guidlines &practices as per approved SIP and circuit diagrams. It includes: Design and modification in existing IFC, ALC etc. of Elsystem, modification in the VDU (Video Display Unit), LCP(Local Control panel), CCIP (Control cum Indication Panel)interface, Maintenance terminal, Relay rack wiring, wiring & modification of Data Logger, connecting new racks to earthing& bonding. 2 All the required materials (Interface cards/relays/wiring material/connectors/fuses/communication devices,power supply modules, material for earth connection etc.) shall be provided by the contractor. The work also includes thesupply of modified Selection table, Interface Circuits, logic circuit, VDU/LCP/CCIP diagram etc. It also includes the carrying out all necessory testings i.e., FAT, SAT (if applicable) etc. jointly with Railways and satisfactory commissioning. Allplans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 02 sets of papercopies anlog with tracing paper to be supplied. Calculation of routes will be done as per Annex-A. (b) Alteration above 10 routes in addition to item 1 above.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022uptocorrectionslipXIFinal26.06.2026.pdf
ATTACHMENT
procedureofdigginginvicnityofcable.pdf
ATTACHMENT
scc771.pdf
ATTACHMENT
1.BORIDANDSIPVERSION01.pdf
ATTACHMENT
1.UDALKACHARSIPVERSION05.pdf
ATTACHMENT
1.DARRITOLASIPVERSION01.pdf
ATTACHMENT