Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹28.8 LAdmitted-Finance | L1 | Admitted-Finance |
Tender Value
₹29.5 L
EMD Value
₹58,924
Closing Date
7 Aug 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Replacement of existing defective sewage pumps and control panels
2026_PWD_296252_1
54/EE (E)/PWD EMD South West/2026-27
Open Tender
Electrical Works
Percentage
30 days
works
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹58,924
13 Aug 2026
31 Jul 2026
7 Aug 2026
31 Jul 2026
7 Aug 2026
31 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED, Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). on existing tunnel / subways upto 10 Mtr by suitable means etc. (Replacement of existing defective fittings) | |||||
| 1.01 | 100 watt | 30 | Each | 2,266 | ₹67,980 |
| 2Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||||
| 2.01 | Upto 35 sq. mm (clamped with 1mm thick saddle) | 500 | Mtr | 64 | ₹32,000 |
| 3Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 3.01 | 3 x 2.5 sq. mm | 100 | Mtr | 148 | ₹14,800 |
| 4 | Fabricating, Supply, installation, testing & commissioning of Outdoor type Feeder Pillar panel upto 300 mm deep suitable for 415 V, 3 phase ,4 wire 50 Hz AC supply system fabricated in compartmentalized & segregated design from CRCA sheet steel of 2 mm thick for frame work and 1.6 mm for covers, with 3 mm gland plates i/c cleaning & finishing complete with powder coating in approved shade, Having 4 strip aluminium bus bar of 600 Amp capacity double door with locking arrangement for protection from rain, dust, fixed on M.S. Angle iron frame work of size 50 mm x 50 mmx 6 mm and 90 cm long legs out of which 40 cm duly grounded in cement concrete, entire panel shall have a common aluminum earth bar of size 25 mm x5mm at the rear with 2 Nos. earth stud, solid connection form main bus bar to switch gear with required size of Alu. bus bar & control wiring with 1.5 sqmm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates, duly grouted in cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Stone aggrete 20 mm) and having following accessories mounted inside the cubical panel board i/c making connection, interconnection with aluminium thimbless & duly painted with one coat of red oxide & two coats of superior quality enamel paint complete etc. as required. (1 No Panel) | 1.5 | Sq.mtr | 43,189 | ₹64,783.5 |
| 5Providing & Fixing of following electrical accessorries/switches etc in the above existing panel board including making connection testing, commissioning etc. complete as reqd. | |||||
| 5.01 | 400 A, 35 KA,TPMCCB (Ics=Icu=100%) Incoming | 1 | Each | 22,644 | ₹22,644 |
| 5.02 | 200 A, 16 KA,TPMCCB (Ics=Icu=100%) Outgoing | 4 | Each | 8,111 | ₹32,444 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.68 MB
BOQ_394324.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .