Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹11.3 LAccepted-Finance 8 TOWNSHEND ROAD KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | 1st | Accepted-Finance 1st lowest bidder | |
| 2 | 2nd₹11.8 L+₹51,900 (4.58%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | 2nd | Rejected-Finance 2nd lowest bidder | |
| 3 | 3rd₹11.9 L+₹56,300 (4.97%)Rejected-Finance | 3rd | Rejected-Finance 3rd lowest bidder |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
6 Apr 2024, 6:00 pmClosed
SUPERINTENDING ENGINEER (P.W.D)
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Urgent Repairing/ Rectification work due to breakdown of 2nos. 22TR, 2nos. 11.5TR (Make- VOLTAS) Ductable unit with AHU for proposed 24 beded hybrid CCU at Kharagpur Sub-Divisional Hospital, Paschim Medinipur.
2024_WBPWD_687762_1
WBPWD/SE/SWEC/NIQ117/2023-24
Open Tender
ELECTRICAL WORKS M/R
Item Rate
7 days
PASCHIM MEDINIPUR
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
OFFICE OF THE SUPERINTENDING ENGINEER,SWEC
6 Dec 2024
25 Mar 2024
8 Apr 2024
25 Mar 2024
6 Apr 2024
28 Mar 2024
28 Mar 2024
Amount
Leack Detection & Rectification of 5.5TRx12Nos Capacitor based air colled condensing unit eco friendly refrigerent, thermostatic expansion valve,scroll compressor arrangement for operation with DX type AHU & sutable for operation on 415+/-10% Volt, 50Hz, 3Phase AC supply, with protection of cranckcase heater, HP/LP cutouts,thermostats, power & control contracts for evaporator fans, condenser fan, compressors and matching condensing unit, isolator switch for condenser unit.
a) Vacumizing the whole system first by ussing double stage vacum pump.
b) Nitrogen filling in the cupper pipe line for detacting leackages.
c) By Brazing leackage rectification.
Supply and Installation of Filter Driers.
Supply And Installation of thermostatc expansion valve.
R407C Refrigerent Charging in the system.
Replacement of Voltas make Outdoor control PCB which can compact with the DX type AHU Control panel. (If required)
Replacement of scroll compressor for voltas make ductable unit(If required)
Supply & Installation of 2HP TEFC, 3phase motor should be compactability with VOLTAS unit for AHU capacity 4200-4400CFM or higher.
Rectification of AHU service door for air leakage problem.
Supply & Installation of Voltas make Control circuit moduler for comunicating betwen DX type AHU & Voltas make Outdoor Unit which can work with VFD contol system with timmer or without timmer setting.
Supply & Installation of Voltas make Corded Remote Control for temperature control.
Rectification of Electrical Conection of AHU control panel.
Replacement of Pre Filter in the section AHU Plenum chamber.
Rectification of mouth Connection in AHU Plenumm chamber.
Rectification of HITACHI make Split unit of model no-RMOG322HEDO.
CARRION AIR COOLING
NAYEE DISHA PROJECTS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .