CWE(NAVY) Chennai
Commander Works Engineer (Navy) Military Engineer Services Fort St George Rajaji Salai Chennai 600009
81457 PROVISION OF DEFICENT STP AT INS PARUNDU, RAMANAD
2025_MES_735971_3
CWE/NAVY/TVL/81457/E8 OF 2025-26
Open Tender
Miscellaneous Works
Lump-sum
360 days
RAMNAD
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
GE Tirunelveli
₹3.1 L
Yes
18 Aug 2026
18 Aug 2026
3 Sept 2026
18 Aug 2026
1 Sept 2026
25 Aug 2026
18 Aug 2026 - 20 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SCHEDULE "A" PART - I SEWAGE TREATMENT PLANTS NOTE: Schedule ‘A’ Part - I is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-7. | |||||
| 2Constructing Sewage Treatment Plant of PMF technology (Phyto Microbial Filtration) consisting of collection cum sludge holding tank (underground) , Phyto microbial filtration bed (Above ground), Filter feed tank (Underground), Treated water tank (underground) and filtrate sump, bar screen chamber and screen in existing pipe line (if necessary) with primary, secondary and tertiary treatment using RCC M-30 Grade concrete with permanent specifications etc.as detailed below, including allied units for waste disposal with all civil, electrical and mechanical works involved, and giving satisfactory hydraulic testing, commissioning necessary piping work with required Ball valves, Non return valve, multi port valve, pressure indicator, flow meter, level switch, UPVC pipe 25/50 mm dia including connection from existing septic tank to primary treatment using bar screen, settling chamber, equilising tank and consisting of following mechanical equipments and supply & installations of E&M equipments/assets, electrical panels etc complete all as shown on drawings for each STPs:- Mechanical Equipments:- (a) Raw sewage submersible pump static tank to collection tank - 01 Working + 01 Standby. Incase the sewage does not transfer by gravity. (b) Raw sewage submersible pump CT to PMF collection tank - 01 Working + 01 Standby | |||||
| 2.01 | (c) Fresh water submersible pump - 01 Working
(d) Treated water Disposal pump - 01 working
(e) Hypo dosing pump - 01 Working
(f) PMF Filtration Media - Gravels and coarse sand
(g) Pressure sand filter - 01 No
(h) Activated carbon filter - 01 No
(j) Hypo dosing tank - 01 No
(k) Bacterial culture for PMF bed - Micro Decomo
(l) Hypo dosing pump - Standard.
(m) Piping (As requried).
(n) Electrical panelling and cabling (As required).
(o) Canna Indica plant (As required).
(p) Centrifugal pump for disposing treated waste water including necessary GI pipe line 50 mm Dia for upto a distance 50 m from each STPs.
(q) Provision of 1 m wide 75 mm thick PCC plinth protection 1:3:6 using 20 mm graded aggregate over 75 mm thick hard core using broken stone and boulders (n.exc 63 mm) all around the STP tanks. | - | - | - | - |
| 2.02 | STP plant of capacity 10.00 KLD with following items. (a) Septic Tank (ST) to Collecion Tank (CT) Sewage submersible pump, non clog type -0.625 cum/Hr @ 10m - 02 Nos (1 Working +1 Standby) (b) Collection Tank (CT) to PMF (Secondary Treatment Bed) monoblock submersible pump -0.625 cum/Hr @ 10m -02 Nos (1 Working+1 Standby).
(c) Filter Feed Tank (FFT) to Treated water Tank (TWT) monoblock submersible pump -0.625 cum/Hr @ 25m -02 Nos (1 Working+1 Standby).
(d) Treated water Tank (TWT) to End use monoblock submersible -0.625 cum/Hr @ 25m -01 No (1 Working).
(e) Chlorine Dosing -0 to 1.5 LPH-01 No (1 Working) with hypo dosing tank of 100 Ltr.
(f) Pressure sand filter (0.23m dia) and activated carbon filter (0.26m dia).
(g) Pipe line with required valves between different parts of plant.
(h) Electrical connections for pumps with required starters and panel. | 2 | Each | - | - |
| 2.03 | STP plant of capacity 20.00 KLD with following items. (a) Septic Tank (ST) to Collecion Tank (CT) sewage submersible pump, non clog type -1.25 cum/Hr @ 10m-02 Nos (1 Working+1 Standby) (b) Collection Tank (CT) to PMF (Secondary Treatment Bed) monoblock submersible pump -1.25 cum/Hr @ 10m-02 Nos (1 Working+1 Standby).
(c) Filter Feed Tank (FFT) to Treated water Tank (TWT) monoblock submersible pump-1.25 cum/Hr @ 25m 02 Nos (1 Working+1 Standby).
(d) Treated water Tank (TWT) to End use monoblock submersible 1.25 cum/Hr @ 25m-01 No (1 Working).
(e) Chlorine Dosing - 0 to 1.5 LPH-01 No (1 Working) with hypo dosing tank of 100 Ltr.
(f) Pressure sand filter (0.33m dia) and activated carbon filter (0.36m dia)". (g) Piping between different parts of plant.
(h) Electrical connections for pumps with required starters and panel. | 2 | Each | - | - |
| 2.04 | STP plant of capacity 30.00 KLD with following items. (a) Septic Tank (ST) to Collecion Tank (CT) sewage submersible pump,non clog type -1.87 cum/Hr @ 10m-02 Nos (1 Working+1 Standby)
(b) Collection Tank (CT) to PMF (Secondary Treatment Bed) monoblock submersible pump -1.87 cum/Hr @10m-02 Nos (1 Working+1 Standby).
(c) Filter Feed Tank (FFT) to Treated water Tank (TWT) monoblock submersible pump -1.87 cum/Hr @ 25m 02 Nos (1 Working+1 Standby).
(d) Treated water Tank (TWT) to End use momoblock submersible -1.87 cum/Hr @ 25m -01 No (1 Working).
(e) Chlorine Dosing -0 to 1.5 LPH -01 No (1 Working) with hypo dosing tank of 100 Ltr.
(f) Pressure sand filter (0.40m dia) and activated carbon filter (0.45m dia). (g) Piping between different parts of plant.
(h) Electrical connections for pumps with required starters and panel. | 1 | Each | - | - |
| 2.05 | STP plant of capacity 40.00 KLD with following items. (a) Septic Tank (ST) to Collecion Tank (CT) sewage submersible pump, non clog type -2.5 cum/Hr @ 10m - 02 Nos (1 Working+1 Standby)
(b) Collection Tank (CT) to PMF (Secondary Treatment Bed) submersible pump -2.5 cum/Hr @ 10m-02 Nos (1 Working+1 Standby).
(c) Filter Feed Tank (FFT) to Treated water Tank (TWT) monoblock pump -2.5 cum/Hr @25m -02 Nos (1 Working+1 Standby).
(d) Treated water Tank (TWT) to End use monoblock pump -2.5 cum/Hr @ 25m -01 No (1 Working).
(e) Chlorine Dosing -0 to 1.5 LPH-01 No (1 Working) with hypo dosing tank of 100 Ltr.
(f) Pressure sand filter (0.46m dia) and activated carbon filter (0.52m dia). (g) Piping between different parts of plant.
(h) Electrical connections for pumps with required starters and panel. | 1 | Each | - | - |
| 3GENERAL SUMMARY NOTE: Schedule ‘A’ Part - II to III are prepriced by MES under Ser No. 4.00 to 5.00. Bidders shall insert their lumpsum amount in the Green coloured field under Col-7 only. | |||||
| 4 | Lumpsum price worked out by the tenderer for “EXTERNAL ELECTRIC SUPPLY ” as listed in Schedule ‘A’ Part - II | 1 | Lumpsum | 2,08,501.42 | ₹2,08,501.42 |
| 5 | Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-III | 1 | Lumpsum | 5,34,033.82 | ₹5,34,033.82 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.22 MB
81457Schedules.pdf
Additional Documents • 0.07 MB
Drawing_Sheet 1-13.pdf
Additional Documents • 0.63 MB
Drawing_Sheet 10-13.pdf
Additional Documents • 1.10 MB
Drawing_Sheet 11-13.pdf
Additional Documents • 1.09 MB
Drawing_Sheet 12-13.pdf
Additional Documents • 0.60 MB
Drawing_Sheet 13-13.pdf
Additional Documents • 0.58 MB
Drawing_Sheet 2-13.pdf
Additional Documents • 1.25 MB
Drawing_Sheet 3-13.pdf
Additional Documents • 0.87 MB
Drawing_Sheet 4-13.pdf
Additional Documents • 0.38 MB
Drawing_Sheet 5-13.pdf
Additional Documents • 0.61 MB
Drawing_Sheet 6-13.pdf
Additional Documents • 0.97 MB
Drawing_Sheet 7-13.pdf
Additional Documents • 0.61 MB
Drawing_Sheet 8-13.pdf
Additional Documents • 0.67 MB
Drawing_Sheet 9-13.pdf
Additional Documents • 0.52 MB
81457Gen.pdf
Tender Documents • 0.72 MB
81457PS.pdf
Additional Documents • 0.92 MB
RevisedDrawing.pdf
Additional Documents • 1.23 MB
BOQ_879720.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].