| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹36.1 L+₹2.5 L (7.29%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹37.1 L+₹3.5 L (10.3%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹37.3 L+₹3.6 L (10.8%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹37.6 L+₹4.0 L (12.0%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
7 Jul 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY , MUDFORT, SECUNDERABAD-500003
REPAIR REPLACEMENT AND MAINTENANCE OF EXTERNAL ELECTRIC LT DISTRIBUTION PANELS AND APFC PANELS AND AMF PANELS SWITCH GEAR AND SOLAR POWER PLANT , DG SET AT CDM AREA UNDER AGE EM NO-I OF GE UTILITY SECUNDERABAD
2020_MES_351468_1
GE(U)/SEC/TOKEN/14 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹94,000
Yes
23 Jul 2020
10 Jun 2020
9 Jul 2020
10 Jun 2020
7 Jul 2020
25 Jun 2020
Amount
M&L for attending, repair and rectification of external LT/HT electric supply complaints on 11000/1100 Volts grade, under ground / over head system along with necessary T & P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
Replacement of LT blown out fuse as per existing capacity in any location of upto 200 Amps.
Replacement of wornout jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Dismantling of defective insulators any size and any type from existing HT line/LT line , complete all as specified Note:- Insulators shall be measured and paid separately under respective items.
Disconnecting from over head conductor, cutting worn out portion of LT/HT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) LT/HT Jointing kits, LT XLPE Cables of any size, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the Pole coping and inserting the cable along with protection pipes.
All as per item Sl No1.06 above but from LT/HT switch gear/main switch board of any type and size including provision of suitable size of aluminum / copper cable lugs.
Dismantling of rusted/ broken over head conductor of any type and length as required at site including removing of forein objects if any from the over head lines and re-stringing by replacing rusted/damaged conductor with new conductor. Notes:- (i) ACSR conductor used for replacement will be measured and paid under respective items. (ii) quoted rate is deemed to be inclusive of trimming of tree branches up to 1.5 Mtr around the conductor.
Replacement of faulty LT switch gear of any type and size fixed in panel board pole mounted boxes on walls or any other indicated places including provision of lugs/thimbles of suitable sizes. Note: - Switch gears will be measured and paid separately under relevant items of this schedule.
Replacement of blown out DO fuse, 11 KV grade of any capacity. Notes: (i) Quoted rate is deemed to be inclusive of Fuse wire of required gauge and necessary T & P required at site. (ii) No additional payments will be admissible for replacement of fuse in same system with an hour. (iii) Set of 3 fuses will be considered as one job for payment purpose.
Dismantling of corroded/ defective cross arms of MS channel or angle setion
Dismantling of steel poles/ concrete poles of an site an location for issue of schedule of credit
Notes for Item Nos 1.01 to 1.12:- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/her for completion of day to day complaints within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify authorised rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventoy format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No I store on daily basis.
Supply only the following materials as in repairs/replacements complete all as specified and directed.
Supply of ACSR conductor of any size for LT/HT over head line connections of squirrel/weasel/Mink as per site requirement including f aluminum biding wire complete .
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade.
(Shackle type insulator, porcelain vitreous, white / brown / green, 1100 Volts grade, 75 mm height & 90 mm dia including galvanised mild steel strap of 31 x 3 mm, 12 mm dia insulator bolt, washers & nuts.
Loop type insulator porcelain vitreous white, brown or green with overall dimensions of 90 x 140 mm, clearance of hole 25.5 mm.
MCCB 63 Amps, 3 pole, 415 Volts with rapturing capacity 16 KA, adjustable thermal and fixed magnetic settings.
MCCB 63 Amps, 4 pole, 415 Volts with rapturing capacity 25 KA, adjustable thermal and fixed magnetic settings.
MCCB 100 Amps, 3pole, 415 Volts with rapturing capacity 25 KA, fixed magnetic and thermal settings.
MCCB 100 Amps, 4 pole, 415 Volts with rapturing capacity 25 KA, fixed magnetic and thermal settings.
MCCB 160 Amps, 3 pole, 415 Volts with rapturing capacity 25 KA fixed magnetic and thermal settings.
MCCB 160 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 200 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 200 Amps, 3 pole, 415 Volts with rapturing capacity 25 KA fixed magnetic and thermal settings.
MCCB 250 Amps, 3 pole, 415 Volts with rapturing capacity 25 KA fixed magnetic and thermal settings.
MCCB 250 Amps, 4 pole, 415 Volts with rapturing capacity 35 KA fixed magnetic and thermal settings.
MCCB 400 Amps, 4 pole, 415 Volts with rapturing capacity 50 KA adjustable magnetic and thermal settings. Note for Item Sl No 2.05 to2.15 : Any modification/ alteration in existing panel which is required to fixing of MCCB is deemed to be included in unit rate
Supply and fix Power contactor coil of Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS94195 or equivalent HPL/Schneider
Supply and fix Power contactor coil of Power contactor of having capacity 200 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS94196 or equivalent HPL/Schneider
Supply and fix Power contactor of having capacity 400 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS94297 or equivalent HPL/Schneider
Supply and fix Power contactor of having capacity 200 Amps 4 pole 2NO +2NC complete all as specified and directed. Make:- L&T Cat part No. CS94083 or equivalent HPL/Schneider
M&L for cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4mm dia as in repairs complete all as specified and directed.
Supply,connect testing and commissioning of cable jointing Kit for 1100 V grade cable for straight through heat shinkble joint with jointing material and accessories suitable for aluminum conductor cable of size upto 35 sqmm, 3.5 Core complete all as specified and directed.
All as per item No 08 above but suitable for aluminium conductor cable of size from 50 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core
All as per item No 08 here-in-before but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 240 Sqmm, 3.5 Core
Supply,lay, test and commissioning for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area laid in trenches / duct or fixed to wall / passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminum conductor of following sizes complete all as specified and directed :-
2 core X 10 Sqmm
4 Core X 16 Sqmm
4 Core X 25 Sqmm
4 Core X 35 Sqmm
3.5 Core X 50 Sqmm
3.5 Core X 70 Sqmm
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 185 Sqmm
3.5 Core X 240 Sqmm Note for item Nos. 11.01 to 11.10:-Excavation, earth work, sand cushioning and cable protection items etc shall be measured and paid under respective items of Schedule 'A'.
Labour only for releasing the binding of ACSR conductor of LT / HT over head line from insulator, removing the jumper, connector, service wire, UG cable and restringing the existing ACSR conductor of any size, length, span upto desired sag and fixing the existing ACSR conductor on insulators by proper binding, jumper connection etc complete all as specified and directed. Notes:- (i) Single run of conductor will be measured as one unit which is deemed to be included in the quoted unit rate. (ii) Extra aluminum conductor required for jumpers and binding purpose is deemed to be included in the quoted unit rate.
M & L for testing earthing of installations, buildings, equipment etc and treating of earthings by pouring salt water and submit results sheet to AGE E/M No-I complete all as specified and directed. Note: Contractor has to arrange necessary tools required for the job
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
All as per item No 14.00 here in before but depth above 1.5 m & below 3 m
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay reinforced precast concrete cable cover LV, Type I,flat, size 250x150x40 mm complete all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping/pedestals of poles including necessary form work complete and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
M&L for stay assembly with all accessories as shown in Electrical Plate No 1 of SSR Part I (2009) with 16 mm dia stay rod and including 7/2.24 mm size stay strand and stay clamps including dismantling old unserviceable stay assembly complete all as specified and directed. Note : Loop type insulator, excavation, earth work and concrete shall be measured and paid separately under relevant items of this schedule.
M&L for cross arms, bracing supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as directed including applying two coat of quality aluminum paint over one coat of red oxide primer and fixed over RCC Pole/ steel poles of any height complete all as specified and directed.
M & L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm center to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed.
M & L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 2 coats of aluminium paint over a coat of red oxide primer including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminum paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule
S&F in repairs surge protection of 10 KV suitable upto 100W LED light fittings suitable to operate on input voltage 440 AC, 50 Hz, complete all as specified and directed. Make: C&S / Havells/ Cromption cat part No 5RPSQ10KV/5KV-440
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 4.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 6.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay heavy duty PVC insulated multi stranded Aluminum conductor twin core of size 10.0 Sqmm, 230 volts, 50 HZ complete all as specified and directed.
Supply & lay Galvanised Iron tubing 50mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 40 X 4 mm, nut bolts and washer as per site requirement including taking down old unserviceable pipes complete all as specified and directed.
All as per item No 31 above but GI tubing 80 mm bore.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line and making good the disturbed portion so as to match existing finishing with 200mm thick PCC 1:2:4 type B1 on top and balance with excavates earth complete all as specified and directed
S&F On- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 200 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCNFO0200 or equivalent make in Havells/Legrand/IndoAsian.
S&F On- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 400 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCNFO0400 or equivalent make in Havells/Legrand/IndoAsian.
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 200Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCFFE0200 or equivalent make in Havells/Legrand/IndoAsian.
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 400 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCFFE0400 or equivalent make in Havells/Legrand/IndoAsian. .
S&F Off- load changeover switch in sheet metal enclosure with front handle operating system, powder coated, factory made of capacity 620 Amps, 4 pole SCHS type with fixing arrangement on site including removing the existing unserviceable one complete all as specified and directed. Make:- Standard Cat No ISCFFE0630 or equivalent make in Havells/Legrand/IndoAsian. .
S&F rewirable switch unit in sheet metal enlosure with powder coated, factory made of capacity 100 Amps, 4 pole with fixing arrangement on site including removing the existing unserviceable one complete all as specified and direted. Make:- Havells Cat No IHBRTE4100 or equivalent make in Havells/Legrand/Strandard .
S&F new generation energy saving and environmental friendly long life versatile pressure die cast aluminum IP66 road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper PVC insulated three core weather proof cable etc, including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Havells Cat Part No ENDURAPEARLPLUSSL90WLED757SASYTOPC or equivalent model of Philips/Wipro.
S&F new generation energy saving and environmental friendly long life versatile pressure die cast aluminum IP66 road way light fitting with high power LED as light source of capacity 70 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper PVC insulated three core weather proof cable etc, including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Havells Cat Part No ENDURAPEARLPLUSSL70WLED757SASYTOPC or equivalent model of Philips/Wipro.
S&F new generation energy saving and environmental friendly long life versatile pressure die cast aluminum IP66 road way light fitting with high power LED as light source of capacity 60 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper PVC insulated three core weather proof cable etc, including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Havells Cat Part No ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent model of Philips/Wipro.
S&F new generation energy saving and environmental friendly long life pressure die cast aluminum housing IP66 road way light fitting with high power LED as light source of capacity 45 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper conductor PVC insulated three core weather proof cable etc, including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Havells Cat No. ENDURAPEARLNEOSL45WLED757SASYTOPC or Equivelant in Wipro/ philips . Notes :- (i) Contractor has to produce LM-79/ LM-80 certificate along with purchase vouchers.
S & F in replacement of LED flood fitting of 160W pressure die cast aluminium body , IP66 on existing pole with provisioning of 2 runs of cable PVC insulated single core unsheathed 1100 volts grade 4 Sqmm multistranded with aluminium conductor from fitting to junction box complete all as specified and directed. Make :- Bajaj Cat Part No. BARFEG160W or Equivalent model of philips/havells.
S & F in replacement of LED flood fitting of 200W pressure die cast aluminium body , IP66 on existing pole with provisioning of 2 runs of cable PVC insulated single core unsheathed 1100 volts grade 4 Sqmm multistranded with aluminium conductor from fitting to junction box complete all as specified and directed. Make :- Bajaj Cat Part No. BARFEG200W or Equivalent model of philips/havells.
S & F in replacement of LED flood fitting of 350W pressure die cast aluminium body , IP66 on existing pole on existing highmast of 12/16 Mtr all as specified and directed. Make :- Bajaj Cat Part No. BARFEG350W or Equivalent model of philips/havells.
S&F in repairs post of top lantern pure polyester UV resistant power coated die cast aluminum housing with PMMA clear diffuser for uniform illumination IP66 LED as light source of capacity 20 watts with suitable drivers, 10 KVA in built surge protection etc and connecting with 2.5 sqmm copper conductor PVC insulated three core weather proof cable etc, including taking down old unserviceable gate light fitting of any type and capacity complete all as specified and directed. Make:- Wipro Cat No. LP07-251-XXX-57-CL or Equivalent in Wipro/ philips . Notes :- (i) Contractor has to produce LM-79/ LM-80 certificate along with purchase vouchers.
S&F in repairs Electronic drivers suitable for 60W LED light fittings suitable to operate on input voltage of AC 100-265 V, 50 Hz, Output DC 36 V, max 350 MA, 0.95 PF complete all as specified and directed. Make: Bajaj Cat part No. BGD 36 185 5Y or equivalent make in HPL/Havells/philips
S&F in repairs Electronic drivers suitable for 90W LED light fittings suitable to operate on input voltage of AC 100-265 V, 50 Hz, Output DC 36 V, max 350 MA, 0.95 PF complete all as specified and directed. Make: Bajaj Cat part No. BGD 36 240 5Y or equivalent make in HPL/Havells/philips
S&F in repairs Electronic drivers suitable for 200W LED light fittings suitable to operate on input voltage of AC 100-265 V, 50 Hz, Output DC 36 V, max 350 MA, 0.95 PF complete all as specified and directed. Make: Bajaj Cat part No. BRFLD 200W or equivalent make in HPL/Havells/philips
S&F in repairs Electronic drivers suitable for 350W LED light fittings suitable to operate on input voltage of AC 100-265 V, 50 Hz, Output DC 36 V, max 350 MA, 0.95 PF complete all as specified and directed. Make: Bajaj Cat part No. BRFLD 350W or equivalent make in HPL/Havells/philips
Supply and fix cable junction box thermoplastic body IP 66 , size 225mmx295mmx122mm suitable for helogen free and weather proof for out door installation with metric knockout for cable entry suitable for cable size 16-35 sqmm including clamp complete all as specified and directed. Make:- HENSEL/ Neptune or equivalent
S&F time light street light control distribution board, outdoor, pole mounted, made out of 3mm thick MS sheet duly powder coated front openable, IP 65 protection, with 2 Nos FI clamps of size 30mm x 4mm complete all as specified and directed including provision of the following accessories:- (a) Digital time switch din type, astronomical programmable every 1 min, backup 6 years, 28 memory locations, current capacity 16 Amps, with 1 changeover (1 CO), total 28 programmers - 01 No. Make:- Indo Asian Cat No TLO32ASO or equivalent make in L&T/Legrand. (b) Power contactor heavy duty 40 Amps TP - 01 No. Make: L&T/C&S/Legrand/IndoAsian. (c) MCB TP,440 Volt, 40 Amps - 01 No. (d) Connector terminal 40 Amps - 06 Nos. (e) Auto manual switch - 01 No. Make : Standard/L&T/IndoAsian.
S&F Weather proof outdoor bus bar chamber, made out of 3 mm thick MS sheet duly powder quoted comprising 4 Nos aluminium strips each of 200Amps, 60cm long duly insulated mounted on insulators including MCCB 200 Amp with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils, including taking out old unserviceable bus bar chamber complete all as specified and directed.
Supply & Fill distilled water in batteries of solar street lights of any capacity and any height all as specified and directed by Engr in charge.
S& F in replacement of old unserviceable lugs after cutting the worn out /faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminum lugs including crimping with crimping tools in the existing LT cable 3.5 core upto 25 Sqmm including necessary connection complete all as specified and directed.
All as per item No 56 above but aluminium lugs of size 35 Sq mm.
All as per item No 56 here-in-before but aluminium lugs of size 50 Sq mm.
All as per item No 56 here-in-before but aluminium lugs of size 70 Sq mm.
All as per item No 56 here-in-before but aluminium lugs of size 95 Sq mm.
All as per item No 56 here-in-before but aluminium lugs of size 120 Sq mm.
All as per item No 56 here-in-before but aluminium lugs of size 150 Sq mm.
All as per item No 56 here-in-before but aluminium lugs of size 185 Sq mm.
S&F conneting and testing MCB isolator Single pole and neutral (TPN) 440 olts of capaciyt 16 A 10 KA 50 "B" curve complete Make:- Indoasian Cat part No. 811031 or equivalent of L&T / Standard/Havells
S&F conneting and testing MCB isolator three pole and neutral (TPN) 440 olts of capaciyt 40 A 16 KA 50 "c" curve complete
S&F connecting and testing MCB isolator three pole and neutral (TPN) 440 volts of capacity 63 A 16 KA 50 "c" curve complete
M & L for digital voltmeter of range 0 to 500 volts and size 96 mm square dial including taking down old defective voltmeter complete all as specified and directed.
M & L for digital ammeter of range 0 to 500 volts and size 96 mm square dial including taking down old defective ammeter complete all as specified and directed.
Supply only LED bulb 5 Watt suitable for B-22 base holder complete all as specified and directed.
Supply only lamp holder suitable for 5 watt LED B22 type complete all as specified and directed.
Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 100 KVARs and up 8 stages installed at various locations at CDM area including carrying out complete maintenance/repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified and directed. Notes:- (i) Rate quoted by tenderer is deemed to be inclusive of checking of system fortnightly, repavement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair by expert technician and register will be maintaned for the same. (ii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system. (iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid seperatly
Supply of power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed.
All as per item No 72 above but 10 KVAR Capacitor Bank
All as per item No 72 here-in-before but 20 KVAR Capacitor Bank
All as per item No 72 here-in-before but 25 KVAR Capacitor Bank Make for item No72 to 75:- L&T CAT No LTBCH or equivalent Make in HPL/Standard/Havells /Schneider/
S&F APFC relay eta CON M series with auto-set function 3 stage including taking down old unserviceable one complete all as specified and directed. Make:- L&T Cat Part No ETACONM003R or equivalent make in Schneider/HPL/Indo Asian.
All as per item No 88 above but APFC relay with auto-set function 5 stage Make:- L&T Cat Part No ETACONM005R or equivalent make in Schneider/HPL/Indo Asian.
All as per item No 88 here-in-before but APFC relay with auto-set function 7 stage Make:- L&T Cat Part No ETACONM005R+ETACONEXP2R or equivalent make in Schneider/HPL/Indo Asian.
All as per item No 88 here-in-before but APFC relay with auto-set function 8 stage Make:- L&T Cat Part No ETACONM008R or equivalent make in Schneider/HPL/Indo Asian.
M&L for Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- (i) Engine oil shall be measured and paid separately (ii) Labour & transportation shall be arranged by contractor,quoted rate deemed to be inclusive in the unit rate. Make: KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON
Up to 35 KVA DG Set
125 KVA DG Set
200 KVA to 250 KVA DG Set
Attending the breakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and rectify the fault and give report to concern JE complete all as directed by Engr-in-charge. Note :- Spare Parts for rectify the fault is measured and paid seperately.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 125 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
M&L for Renewal/ repairs of unserviceable automatic voltage regulator (AVR) above 125KVA and upto 320 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM approved make.
M&L for Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directed by Engr- in- Charge for the following capacity DG Sets.
Up to 35 KVA DG set.
40KVA to 125 KVA DG set.
200 KVA to 250 KVA DG set.
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply of Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply of Armature coil for self starter of any make, any capacity and any model 24 Volts including testing complete all as directed by Engr-in-charge
Rewinding of field coil for self starter of 24 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engr-in-charge.
M&L for Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 12 volts and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts like bearings, carbon brushes, clutch plates etc & assembling including after repair refixing the self starter in its original position,making all connection as per DG Set OEM recomendation, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply of Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed by Engr-in-charge
Rewinding of field coil for self starter of 12 volts with fine enamelled copper conductor of same gauge with 'F' class insullation, size twins and weight with necessary insulating materials, guage of conductor suitablef any make, any capacity and any model complete all as directed by Engr-in-charge.
M&L for Disconnecting the oil cooler of capacity up to 100 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge
M&L for Disconnecting the oil cooler of capacity above 100kVA to 250KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed by Engr-in-charge
M&L for Renewal/ replacement of existing unserviceable air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed by Engr-in-charge: - Make for item No.10 to 10.04:OEM recomended.
Up to 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 250 KVA DG Set
M&L for Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical/electrical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using chemical detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers and Anti vibrating mounting(AVM) pads as required as per OEM recomendation etc., for the following DG sets all as specified and directed by Engr-in-Charge:
Upto 100 KVA DG Set
Above 100 KVA and up to 125 KVA DG Set
Above 125 KVA and up to 250 KVA DG Set
M&L for Renewal of battery cable leads of copper conductor and with brass lugs terminal, for the 12V, 150/180 /200 AH batteries to self stater as that of existing size and length complete all as directed by Engr-in-charge
S&F Automatic cut off type Battery Charger suitable for 12 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix
S&F Automatic cut off type Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix
M&L for Renewal/replacement of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- FENNER/ DUNLOP
Upto 100 KVA DG Se
above 100 KVA and up to 125 KVA DG Set
above 125 KVA and up to 250 KVA DG Set
M&L for Renewal/replacement of fan belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recomendation
Upto 100 KVA DG Set
above 100 KVA and up to 182.5 KVA DG Set
above 182.5 KVA and up to 320 KVA DG Set
M&L for Renewal/replacement of Dynamo belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- As per OEM Recomendation
Upto 100 KVA DG Set
above 100 KVA and up to 125 KVA DG Set
above 125 KVA and up to 250 KVA DG Set
M&L disconnecting & removing the unservicable DC wiring from DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & checking of electrical/electronic spares working condtion and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate.
M&L for replacement of existing unserviceable water temperature gauge with new water temperature gauge for the DG set of any description inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make
M&L for replaceemnt of existing unserviceable lubricant oil temperature gauge with new lubricant oil temperature gauge for the DG set of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make
M&L for replacement of existing unserviceable oil pressure gauge with new oil pressure gauge for the DG SET of any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make: OEM recomended make
M&L for replacement of unserviceable solenoid switch with new solenoid switch 12volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recomended
M&L for replacement of unserviceable solenoid switch with new solenoid switch 24volts for DG set of any make and any capacity inclduing making necessary electrical /mechanical connections and taking down old unserviceable one complete all as directed by Engr-in-charge. Make :- OEM recommended
S&F in repairs the following spare parts for any type/make of DG sets, as and when required by the department complete all as specified and directed. Make for item no 23 to 23.10:- OEM recommended
Starting/Ignition - key/button
Volt Meter 0-500V
Amps Meter
Frequency Meter
S.D Valve assembly
Oil safety control
Water safety control
Water separator bowl 3247715
Hour Meter
Radiator Metal Pipes
Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO
Supply and filling the new engine oil 15W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 625 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set capacity up to100 KVA capacity listed parameters including testing complete all as specified and as directed. Make :- OEM recommended
Drain out the fuel from the fuel tank of DG set of capacity 400 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat of synthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed by Engr-in-charge.
All as per item No. 112 above but upto 250 Ltrs complete all as directed by Engr-in-charge.
S&F in replacement of Rectifiers of existing Make to DG Set of 100 KVA to 250 KVA capacity with all listed parameters including testing complete all as specified and directed.
All as per item No. 113 above but capacity up to 100 KVA capacity
M &L for Removing of defective engine oil control pressure switch supply & fix new engine oil control pressure switch suitable for up to 100KVA DG set complete all as directed by Engr-in-charge.Make as per OEM Recommendation.
All as per item No. 114 above but Above 100 KVA to 250 KVA DG set
M&L disconnecting & removing the unservicable AC wiring from AMF panel of DG set of any type/any make/any model/any capacity and rewiring with the same with suitable new copper wire to existing guage wire by providing flexible pipe including making all electrical connections as per OEM recomendation for satisfactory completion of job & replacement of electrical/electronic spares and testing etc complete all as specified and directed. Note: (i) The rate quoted deemed to be inclusive of new copper wire cost in the unit rate. (ii) Electrical/Electrnoc spares shall be measured & paid separately under relevant items.
Supply only following spare parts :-
Push buttons.
AMF Panel Hooter
Earth fault relay.Make: OEM recomeded
Over load relay.Make: OEM recomeded
Over/Under voltage relay.Make: OEM recomeded
Auxilary relays 12v/6Amps Make: OEM recomeded
Single phase preventer,make:minilec/GIC
Auxiliary Relays 24Volts / 6A Make: OEM recomeded
PLC based AMF relay unit Make: OEM recomeded
Low lube oil safety switch Make: OEM recomeded
Booster Relay 24Volts / 10A Make: OEM recomeded
Battery charger 24 V /10A panel mounting type Make: OEM recomeded
Battery charger 12 V /10A panel mounting type Make: OEM recomeded
Coolant temparature sensor Make: OEM recomeded
M&L for Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.
M&L for Removing the defective charging dynamo of capacity 12 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the rewinding the damaged winding of field coils with super enameled copper wire suitable to same existing size/guage & reconnecting the same, refixing back, in original position including making all necessary electrical/mechanical connections testing and commissioning complete all as directed by Engr-in-charge.
M&L for replacement of unserviceable spares for water manifold and Radiator spares upto 35 KVA DG set for the following spares:-
Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 35 and upto 125 KVA DG set for the following spares:-
Radiator rubber hoses.
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for replacement of unserviceable spares for water manifold and Radiator spares above 125 kVA and upto 250KVA DG set for the following spare:
Radiator rubber hoses
Clamp for hump hose.
Hose clamps.
hump hose.
M&L for Inhibitor corrosion (coolant additive concentrate) required for top up (TVS Make) complete all as directed by Engr-in-charge.
Supply and topping up of acid mixture suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.
Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed by Engr-in-charge.
S&F battery brass terminal and jelly complete all as specified and directed.
M&L for Disconnecting all connection & remove the PT pump from engine and transport to OEM authorised service center and Calibration of PT pump for maximum efficiency by OEM Authorised Service center & replacement of PT Pump kit, gear gasket, etc in its original position by making all necessary connections complete whichever required under AGE E/M-II(U) AOR for smooth functioning of fllowing DG Set capacities complete all as directed by Engr-in-charge (a)
DG Set capacity up to 35KVA
DG set capacity above 35KVA to 125KVA
DG Set capacity above 125KVA to 250KVA
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity up to 35 KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for up to 35KVA capacity DG set
Supply only Barrel and Plunger for up to 35KVA capacity DG set
Supply only FIP Bearing for up to 35KVA capacity DG set
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following un serviceable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 35 KVA and upto 125 KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above above above 35 KVA and upto 125 KVA capacity DG set
Supply only Barrel and Plunger for above 35 KVA and upto 125 KVA capacity DG set
Supply only FIP Bearing for above 35 KVA and upto 125KVA capacity DG set
M&L for remove the fuel injection pump from the engine transport to an authorized service centre for service, calibration and to adjust by replacing the following unservicable worn-out spares with new appropriate make minor spares and bringing and fixing to the engine and tune up for maximum efficiency all as specified and as directed for DG set capacity above 125 KVA and upto 250KVA :- Note: Major spares required will be measured and paid seperately.
Supply only orfice for above 125 KVA and upto 250 KVA capacity DG set
Supply only Barrel and Plunger for 125 KVA and upto 250KVA capacity DG set
Supply only FIP Bearing for above 125 KVA and upto 250KVA capacity DG set
Supply and fix self starter Motor, 24 volts, Make LUCAS or its equivalent make approved by OEM of DG Set suitable for existing DG set above 82.5 KVA to 250 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge
Supply and fix self starter Motor, 12 volts, Make LUCAS or its equivalent make approved OEM of DG Set suitable for existing DG set capacity up to 82.5 KVA including making all necessary electrical/mechanical connection as per recomendation of OEM of DG Set & dismantling/taking out old unserviceable self starter Motor from existing position complete all as directed by Engr-in-charge
S&F Flexible Bellow suitable for up to 125 KVA Gen Set. Make as per OEM
S&F Flexible Bellow suitable for above 125KVA and up to 250 KVA Gen Set. Make as per OEM
M&L for Servicing of DG Set panel's ACB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, Spring charge Motor working system,checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
M&L for Servicing of DG Set panel's MCCB Breaker indoor/outdoor type of any make/model/capacity, checking of switching ON/OFF & tripping system, checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to DG Set of capacity up to 125 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.
Supply,install, test, commissioning & run the DG set's Fly-wheel Ring of Fly-wheel Assembly of existing model,size suitable to existing DG Set of capacity above 125kVA up to 250 KVA including taking down old Unserviceable complete all as directed by Engr-in-Charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity up to 125 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engr-in-charge.
Disconnect the Radiator and kept aside safely and taking down the old unserviceable water pump from the existing engine of DG set any make/model, capacity above 125KVA and up to 250 KVA supply and fixing of new water pump & kit,reassembling the same and refixing the pump to the engine of DG set, refixing Radiator and testing, including making all Electrical/mechanical connections,commissioning as per OEM recomendation complete all as directed by Engr-in-charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity 125 to 250 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply, Fix & test run the DG set after replacing Diesel feeder Pump of existing model,size suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply, Fix Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity up to 125 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
Supply, Fix Diesel benjo Hose pipes of 1.0 Meter length with both edges brass clamps of existing model suitable to DG Set of capacity above 125kVA up to 250 KVA including taking down old unserviceable complete all as directed by Engr-in-Charge.
M&L for disconnecting all electrical & mechanical connections,Dismantle the Engine (make KIRLOSKER/ CUMMINS /GREAVES/ GREAVES COTTON/ASIATIC/ RUSTON) from 100KVA to 200 KVA DG set capacities located at various location under AGE E/M-II(U) and transported to OEM Authorised service center for complete overhauling, replacing the following unservicable worn-out spares with new appropriate make minor spares & major spares (minor spares- up to Rs 2500/Each), after assembling the spares the Engine again shfted to original existing place and reassembled to alternator& radiator,AMF panel/Electrical panel board of DG set complete testing, commissioning all as per OEM recomendation and as directed by Engr-in-charge.The quoted rate inclusive of Manpower, Crane charges for transporting engine to wokshop and back after repairs Note: - (i)Major Spare parts shall be measured and paid separately.
Gear fuel Pump
Total Gakets Set
Core & cooler set
Shaft rocker arm
Oil seal
Ball Bearings set
Main Bearings set(STD)
Material and labour for repairs to Alternator of following DG Set, transporting the same to the OEM authorised service center/work shop and carrying out the repairs such as taking out the burnt out winding and rewinding the alternator with copper wire of same guage turns and weight, checking of commentator, brushes complete and refixing the same in its existing position after transporting back to the site and connecting up electric connections with suitable lugs complete and testing all as specified and directed. Note: Copper winding material will be measured and paid seperately under relevant Item
Upto 100 KVA capacity
Above 100 KVA and upto 125 KVA Capacity
Above 125 KVA and upto 250 KVA Capacity.
Supply only High conductivity copper conductor winding material including necessary insulation material as requred for complete all as specified and directed by Engr-in-Chrage
M&L taking down defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same for the following capacities including testing complete all as specified and directed.
DG Set of capacity upto 35 KVA
DG Set of capacity above 100 KVA and up to to 125 KVA
DG Set of capacity above 125 KVA and up to 250 KVA
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it out side work to workshop, complete all as specified and directed:-
DG Set of capacity 7.5 KVA To 40 KVA
DG Set of capacity above 100 KVA and up to to 125 KVA
DG Set of capacity above 125 KVA and up to 250 KVA
M & L for dismantling & disconnecting all connection of the cylinder heads from diesel engine and sent to OEM authorised Service center for calibration and repairs by replacing the spares such as Valves, Value Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for the following capacities including testing complete all as specified and directed:-
DG Set of capacity upto 40 KVA
DG Set of capacity above 100 KVA and up to to 125 KVA
DG Set of capacity above 125 KVA and up to 250 KVA
Supply&Fixing of 200/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
M&L preparation of old painted surfaces of the DG Sets of the above 25 KVA and up to 82.5 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 82.5 KVA and up to 125 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
M&L preparation of old painted surfaces of the DG Sets of the above 125 KVA and up to 250 KVA capacity including degreasing and spray painting the DG sets with one coat of synthetic enamel paint of approved colour and writing SM/MES No including painting on concrete surfaces of foundations with black paint complete all as specified and directed.
S&F in replacement of microprocessor based control unit suitable to DG set of 200 KVA to 250 KVA capacity with all listed parameters as per recomendation including testing complete all as specified and directed.
STANDARD AGENCIES
M Laxmana Rao and Sons
diesel power services (a.p)
Sri Balaji Enterprises
omsai thermax engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .