| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC | L1 | Accepted-AOC Found lowest, reasonable | |
| 2 | L2₹18.7 L+₹3.1 L (19.8%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹19.5 L+₹3.8 L (24.5%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L3 | Rejected-Finance In order but L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to Un-enlisted in MES and also not having enlistment criteria for appropriate class in MES |
Tender Value
Refer Docs
EMD Value
₹47,980
Closing Date
4 Sept 2024, 6:00 pmClosed
GE (U) Meerut Cantt
Roorkee Road Meerut Cantt
REPAIR/REPLACEMENT/ MAINT OF SUMMER /WINTER APPLIANCES UNDER AGE E/M (ES) AT GE(U) E/M MEERUT CANTT
2024_MES_663646_1
8610/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please prefer tender documents
11 documents required · 11 mandatory
₹500
GE (U) Meerut Cantt
₹47,980
Yes
6 Feb 2025
3 Jul 2024
11 Sept 2024
3 Jul 2024
4 Sept 2024
17 Jul 2024
Amount
WATER COOLERS:- M&L for Cleaning of water cooler tank with Potassium permanganet solution after removing all dust, mud particles complete all as specified.
M&L for Repairing the water cooler storage tank of stainless steel or any other metal by providing welding, brazing/soldering and making the tank leakage proof complete all as specified and directed.
M&L for renewal of sealed unit Compressor for 40/80 to 120/180 ltr capacity including taking out old us compresssor with necessary brazing work to make the system leak proof complete all as specified and directed. (Note: Refrigerant gas supplied and charged shall be measured and paid separately) Make :- Kirloskar AHR. 13/ TECUMSEH 4445, AW 1000
M&L for charging of Refrigerant Gas R12/R22/R410A/R 134 in the sealed system of window/Split type Air conditioners 1.5/2 Ton capacity water cooler, refrigerator and deep freezer of any capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing , vacuuming the system and charging gas in required quantity complete all as specified and directed. Note: If the recharged refrigerent gas is leaked within one month of running of machine, the contractor shall recharge gas including replacement of copper capilary tube without any extra cost to department.
M&L for Replacement of relay set consisting overload protector suitable for water cooler compressor any capacity for Kirloskar/ Tecumseh compressor complete all as specified and directed.
M&L for Replacement of condenser fan motor single phase, with blade,1/3.5 HP to 1/10 HP capacity including moutning clamps, bushes, nuts, bolts and washers of water cooler complete all as specified and directed.
M&L for Replacement of Liquid line filter for water cooler of any capacity all as specified and directed.
M&L for Replacement of thermostat for water cooler all as directed by Engineer-in-Charge.
M&L for Replacement of Brass CP push cock 15mm bore with brass flex nipple complete all as specified.
M&L for Replacement of 32 mm bore PVC flexible pipe complete all as specified and directed.
DEEP FREEZER:- M&L for Replacement of harmertically sealed unit Compressor of 320/500 litres capacity DEEP FREEZER of duly including necessary brazing work to make the system leak proof including taking out oul us compresssor complete all as specified and directed. Make:- LG/Videocon/Blue star/Carrier Note:-Rate of refrigerant Gas charge paid separately in relevent item.
M&L for Servicing /Cleaning of Deep freezer with Potassium permanganet solution after removing all dust, mud particles complete all as specified.
REFRIGERATOR:- M&L for Replacement of hermertically sealed unit Compressor of 315/320 litres capacity Refrigerator duly including necessary brazing work to make the system leak proof including taking out oul us compresssor complete all as specified and directed. (Note: Refrigerant gas supplied and charged shall be measured and paid separately) Make :- LG, Videocon, Voltas, Whirlpool
M&L for Replacement of hermertically sealed unit Compressor of 165/185 litres capacity Refrigerator duly including necessary brazing work to make the system leak proof, including taking out oul us compresssor complete all as specified and directed. (Note: Refrigerant gas supplied and charged shall be measured and paid separately). Make :- LG, Videocon, Voltas, Whirlpool
M&L for Renewal of Liquid line filter for refrigerator of any capacity all as specified and directed.
S&F for Replacement PVC bottle guard suitable for 165 to 310 Ltr complete all as specified and directed.
S&F in replacement chilled tray plastic for suitable for any make/ any model/ any capacity refrigerator complete all as specified and directed.
S&F for renewal timer switch for suitable for rafrigerator any make/any model/any size complete all as specified and directed.
S&F for Replacement of starting relay, open type for refrigerator of any capacity complete all as specified and directed.
M&L for Replacement of over load protector for refrigerator of any capacity all as specified and directed.
M&L for Replacement of thermostat with knob defrost type/ non defrost type for refrigerator all as directed.
M&L for Replacement of freezer cabinet with door comprising spring suitable for any capacity refrigerator complete all as specified and directed.
M&L for Replacement of condensing coil of any capacity refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as specified and directed. Note: Refrigerant gas supplied and charged shall be measured and paid separately).
DESERT COOLER:- M&L for Replacement of defective burnt exhaust kit fan motor of 1/1.5 HP, any sweep and of any make and transporting to contactor's workshop, opening of motor taking out rotor and cutting out the burnt winding and cleaning the slots and rewinding of the same with the existing size of super enameled aluminium winding wire including insulation varnishing, greasing, reassembling testing and fixing in position all as directed.
S&F for Replacement of kit fan motor, single phase, 230 volt AC, 1/3 HP, complete with blade arm 20" sweep size, fixing lungs, nuts, bolts and washers suitable for desert cooler all as specified and directed. Make :- Polar/ Khaitan/ Bajaj
S&F for Replacement of submersible mini water lifting pump, single phase, 230 volt AC, 50 HZ, 1/40 HP ( 18 watts approx), of 5 meter head all as specified and directed.
M&L for Spray painting of desert cooler body of any size internally and externally after scrapping out the existing paint with one coat of synthetic enamel paint on outer surfaces and one coat of anticorrosive paint on inner surfaces all as directed by EIC
M&L for Replacement of Front grill of Desert cooler of any size of suitable guage complete as directed
M&L for Renewal of wood wool pad suitable for desert cooler all as directed
S&F for Replacement of PVC pipe 15mm dia, medium quality for desert cooler all as directed.
M&L for Renewal of desert cooler body of size 1Mx1Mx1.2M, suitable for 450 mm/500 mm sweep exhaust fan /kit, made out of 18gauge PGI sheet and side panels duly filled with Khas khas including painting the inner surafces with one coat of anticorrosive paint and outer surfaces with two coats of synthetic enamel paint over a coat of primer, deassembling the fan, pump and its connected fittings, grills, regulator and cable etc.from wornout body and fixing the same in renewed Cooler Body complete all as specified and directe.
M&L for Renewal of desert cooler side panels of desert cooler, made out of 22 gauge PGI sheet and side panels duly filled with Khas including painting the inner surafces with one coat of anticorrosive paint and outer surfaces with two coats of synthetic enamel paint over a coat of primer to match with the Body of desert cooler complete all as specified and directe.
VOLTAGE STABILIZER:- M&L for Rewinding of main power transformer of 4 to 5 KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing including indicator bulb suitable for Voltage stabilizer complete all as specified and directed.
M&L for Rewinding of main power transformer of 0.5 to 3KVA capacity Voltage stabilizer , with suitable size of supper enamelled copper wire and fixing & testing complete all as specified and directed.
M&L for Renewal of cut off relay suitable for 0.5 to 5 KVA capacity Voltage stabilizer complete all as specified and directed.
S&F for Renewal of High/ low cut off with time delay circuit suitable for 0.5 to 5 KVA capacity Voltage stabilizer complete all as specified and directed.
S&F for Replacement of Printed circuit Board (PCB) suitable for 0.5 to 5 KVA capacity Voltage stabilizer complete all as specified and directed.
S&F for Replacement of Trigger Transformers suitable for 0.5 to 5 KVA capacity Voltage stabilizer complete all as specified and directed.
S&F for Replacement of single phase Voltmeter AC, 230 Volts for Voltage stabilizer complete all as specified and directed.
S&F for Replacementof 4 to 5 kVA automatic line Voltage stabilizer, single phase, naturally air cooled, wall mounted, indoor type Copper coil type, designed to give output voltage 225V +1.1% at input range between 140 to 280 Volts, with digitally displayed features, high and low cut of range voltage and time relay of 2 to 3 minutes on initial startcomplete all as specified and directed.
GEYSERS:- M & L Dismantling and removing the existing 25/50 Litre Geysers of any type, any make, from various lacations of GE (U) Meerut area after disconnecting the water connection, electric connection for repair/ replacement of defective parts, opening the geyser assembly and descalling with hydrochloride solution fixing of geyser assembly, cleaning up inner tank including repair of rubber seal, ring nuts, bolts, washers GI bottom cover and other connected works, pressure testing, refixing at it's original location, connecting complete all as directed (new spares followed below shall be measured and paid seperately, minor spares and consumables like screws, washers, cleaning agents, consumables etc. is deemed to be included in the quoted rate) for the following:-
S & Fixing only in repairs indicating lamp unit round / rectangular type, suitable for any type, any make geyser, standard quality, AC, 240V, Red or Green, connecting complete all as specified and directed.
S & Fixing only in repairs fusible plug made out of brass with internal or external threading suitable for any type, any make geyser of capacity 25 / 50 Ltrs complete all as specified and directed.
S/F in repairs Inner assembly for 25/50 litre geysers with heat resistant rubber ring washer incl nuts, bolts, clamps, suitable for any type, any make Geyser, ISI marked, complete all as specified and directed.
S & Fixing for 25/50 litre geysers repairs inner tank made out of heavy duty steel sheet, ISI Marked, suitable for any type, any make geyser, for the following capacities complete all as directed and specified.
S & Fixing only in repairs Metallic Outer cover including bottom and top cover fabricated out of 24 gauge MS sheet duly painted suitable for any type, any make geyser complete all as directed and specified.
M&L for repairs to any type, any make geyser metallic inner tank, arresting the leakage by welding, brazing etc, pressure testing after repairs, complete all as directed and specified.
M&L for filling the glass wool between outer cover and inner tank of any type, any make geyser, 50/25 litres capacity,complete all as specified and directed.
M&L for Preparing the surface of any type, any make geyser, remove the existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint with synthetic enamel white paint over a coat of red oxide primer, including writing the MES Nos. complete all as specified and directed.
M&L for Fabricate and fix, GI bottom cover / inspection plate, suitable for any type, any make geyser, 2 mm thick, split type, duly painted with 2 coats synthetic enamel paint over a priming coat of metallic primer to match with the existing colour complete all as directed.
M&L for replacement of bottom main terminal, synthetic gasket, fixing clamps suitable for any type, any make geyser complete all as specified and directed.
M & L for making hole in wall, Grouting 4 No's Rag bolts of size 125mm long x 12mm dia in PCC on wall including suitable nuts and washers for fixing / hanging geysers, complete all as specified and directed.
S/F in repairs Heating element 2.0 KW suitable for any type, any make geyser, 240V, AC, ISI Marked, with heat resistant rubber washer, for the following capacity, connecting complete all as directed. Make :- Theta/ Daspass/ Power Pack.
S/F in repairs Thermostat control unit suitable for any type, any make 25 / 50 Ltrs capacity geyser, 30-90 degree rating, 240V, AC, ISI Marked, connecting complete all as directed. Make :- Elcon/ TTE/ Power Pack.
S/F non-return valve, made out of brass 15mm bore, ISI marked, complete all as directed.
S/F PVC sheathed,PVC insulated multi stranded copper conductor, 3 core, flexible cable, 1100 V grade, 2.5 Sqmm, AC, connecting complete all as directed. Make :- Prayag/ Bharat/ Ajay.
S/F Angle cock / valve, cast copper alloy, chromium plated, screwed down, high pressure, 15 mm with CP cup all as directed.
S/F Bib Tap, hot water, cast copper alloy, chromium plated, screwed down, high pressure, 15 mm with CP cup all as directed.
S/F low density polyethlyne pipe 16 mm dia (outer), 600mm long suitable for Hot/Cold water application complete with threaded union, teflone washers on both sides to suit 15 mm dia fittings. Complete all specified and directed.
S/F in repair for plug top 3 pin 15 Amps capacity complete all as specified and directed .
Supply only Zebra fastner of size 12x100 mm complete all as specified and directed .
S/F in repair SPN metallic enclosure with a two pin and earth plug and socket with one MCB SP 25 Amps all as directed.
Fixing only Water heater storage type (Geyser) Including material & labour for Installation of Geyser of 25/50 ltrs capacity complete all as specified and directed.( Item will be issued by MES Department)
Split and window AC:- M&L for servicing of split/ window AC complete unit by means of electric blower & water under pressure, cleaning & washing of cooling /condencing coil by soap solution or recommended chemical, oiling & greasing of moving parts such as blower motor etc complete of any capacity all as specified and directed.
M&L for Converting the connection of existing AC ( window / Split ) type from cooling system to heating system of the existing AC by using necessary items/ equipments/ toggle switch, Reverse valve etc. from window/ Split type capacity complete all as specified and directed. Note:- Refrigerent gas filled shall be measured separately
Supply and fixing in replacement of new compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection complete including taking out oul us compresssor for 1.5 ton Window type/split Air conditioners complete all as specified and directed. Make :- Tecumesh/ Kirloskar/ Carrier/ Bluestar/ LG.
All as per above but of capacity 2 ton complete all as specified and directed. Make :- Tecumesh/ Kirloskar/ Carrier/ Bluesta/ LG.
M&L for replacement of filter drier and capillary tube in the sealed system of window/Split type Air conditioners 1.5/2 Ton capacity all as specified.
S&F (in repairs) Suction copper pipe line heavy duty 1/4" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5/2 TR capacity all as specified and directed
S&F (in repairs) Suction copper pipe line heavy duty 1/2" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5/2 TR capacity all as specified and directed
S&F (in repairs) Discharge copper pipe line heavy duty 3/8" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5/2 TR capacity all as specified and directed
S&F (in repairs) Discharge copper pipe line heavy duty 5/8" dia with puff insulation and flair nuts from indoor to outdoor unit of split AC 1.5/2 TR capacity all as specified and directed
S & F Condensor fan motor 1/5 HP split AC 1.5/2 TR complete all as specified and directed.
S&F in repair split AC of capacity 1.5 / 2 TR Blower motor 1/3 HP for indoor unit split type AC suitable for any Make / any model as per site requirement complete all as specified and directed.
S&F Condensor fan metallic blade suitable for split/ window AC of any capacity complete all as specified and directed.
S&F blower fan PVC type suitable for split/ window AC of any capacity complete all as specified and directed
S&F Running capacitor 36/ 45 mfd suitable for split/ window AC of any capacity. Make:- EPCOS/Havells/TESLA.
S&F Thermostate suitable for split/ window AC of any capacity complete all as specified and directed.
S&F plastic / juite Air filter suitable for split/ window AC of any capacity.
S&F Cooling coil assembly suitable for split/ window AC any make / any model as per site requirement including taking out old us coil complete all as specified and directed.
S & F Condensor coil assembly suitable for split/ window AC any make / any model as per site requirement including taking out old us coil complete all as specified and directed.
S & F Front grill plastic type as per sample complete all as specified and directed.
S & F Capacitor 6 mfd Make : EPCOS/Havells/TESLA.
M&L sheathed, insulated multi stranded copper conductor Copper wire 3 core 4 sqmm 415 volt complete all as specified and directed.
Supply and fix in replacement of electronic circuit plate (PCB) including necessary repairs to electronic circuit for remote operation suitable for 1.5 / 2.0 ton split type / Window AC HOT/COLD of any make or any capacity.
Supply and fix in replacement of remote suitable for 1.5 / 2.0 ton split type / Window type AC of suitable any make
Supply and fix in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC. Make:SIEMENS/L&T
Labour for shifting of split AC 1.5, 2 ton capacity one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of New location indoor/outdoor unit complete with Gas charging tested on full load on site requirement. (Note: Refrigerant gas supplied and charged shall be measured and paid separately)
M&L for replacement with new indoor unit of capacity 1.5 ton Hot/Cold with cooling coil, blower motor complete with all accessorie complete all as specified and directed.
M&L for replacement with new outdoor unit of capacity 1.5 ton Hot/Cold with condensor coil, blower motor 1/6 HP, single phase, including fixing in old serviceable compressor and connection of copper tubing suction / discharge complete all as specified and directed.
M&L for replacement with new indoor unit of capacity 2.0 ton Hot/Cold with cooling coil, blower motor complete with all accessories complete all as specified and directed.
M&L for replacement with new outdoor unit of capacity 2.0 ton Hot/Cold with condensor coil, blower motor 1/6 HP, single phase, including fixing in old serviceable compressor and connection of copper tubing suction / discharge complete all as specified and directed.
Solar Water Heater:-Taking down the Solar Water Heater from the site after disconnecting the water connection, electric connection, opening the solar water heater assembly and descalling with hydrochloride solution fixing of Solar water heater assembly, Dismantling solar panel, any Make or type by removing the glass panel carefully and refixing it cleaning dust, cleaning the water collector tubes and aluminium foil including descaling the existing hot water storage tank of any capacity and replacement of rock wool including repair of brass flange, ring nuts, bolts, washers and other connected works preparation of steel surface of water by rubbing with emery paper, painting the surface by spray painting with one coat of synthetic enamel paint of approved make without damaging other parts / wiring of the machine and refixing the same in its original position of electric back up with thermostat, making cold / hot water connection GI pipes as required to make the system functional and connecting up with hot concealed water pipe line for following capacity :- Note :- Spares and accessories will be measured and paid seperately.
200 Ltrs capacity Solar water heater
300 Ltrs capacity Solar water heater
500 Ltrs capacity Solar water heater
S&F in rapair Rotational Moulded polythene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltrs complete all as specified ISI Marked. Make: Syntex.
Taking down of old flexible rubber pipe and Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S&F BALL VALVE of size 20 mm
S/F in repair GI tubing medium grade with all fittings and fixed to walls/ceiling/floor or laid in trenches of 15 mm bore size all as specified and directed.
All as per above but for 20 mm bore size.
S/F in repair of hot water piping insulation with two layers of glass wool 25 MM thick covered with chicken wire mesh 24 Gauge and over all covering with aluminium sheet of 28 gauge all as directed.
S/F in repair gun metal or globe or gate valves 20 mm dia with iron wheel scewed both ends all as directed.
S/F in repair Float valve 20 / 25mm dia high pressure with polythene float valve and fly nut complete screwed all as specified.
S/F in repair flat plate collector consisting of transparent cover, riser tube, absober plate, header tube complete all as directed of Make : Tata power Solar/V-Guard
S/F in replacement glass panel rubber beeding of approved quality for solar plate/tubes, complete all as directed.
S/F in replacement heating element of 3 KW, B.S.P threaded with thermostat pocket and metal cap all as per existing one complete as directed.
S/F in replacement of thermostat size 6/11' long, suitable for Solar Water Heater of any capacity all as directed.
Supply and fixing MCB, SP, AC, 240 volts "C" series capacity of 06 to 32Amps, 10kA and making connections complete all as specified & directed.
Supply & fixingI solator, DP (Double Pole), AC, 240 volts, B series capacity 32 Amps and making connections complete all as specified & directed.
Material and labour for sub main wiring with 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed.
Material and labour for sub main wiring with 04 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC concealed conduit of 25 mm dia, medium grade with all conduit accessories / fittings, brass screws, washers etc and connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing incl taking down old u/s submain wiring complete all as specified & directed.
(d) Exhaust Fan Ceiling Fan & Exhaust fan :-M&L for servicing, repair and replacement of unserviceable parts at E/M yard including opening of fan body, cleaning, separating serviceable parts for reuse / refix same after repairing and replacing defecive parts witth new one (new spares shall be measured and paid seperately, minor spares and consumables like MS screws, 2 way connector, rubber/ reel, insulator,condenser holder, ms nuts bolts, washers, grease is deemed to be included in the quoated rate reassembling, greasing, including taking out and refixing original position complete all as specified and directed.
Ceiling Fan 1200/1400mm Sweep of any make or model
Wall / Cabin Fan 400 / 450mm Sweep of any make or model
Exhaust Fan 250/ 300mm Sweep of any make or model
Exhaust Fan 380/450mm Sweep of any make or model
M & L for rewinding the fans of any make, any model, at MH Complaint Cell, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc, replacement of body screws, testing and commissioning on full load for 4 hrs continuous running all as directed for the following:-
Ceiling Fan 1200mm/1400 Sweep of any make or model
Wall / Cabin Fan 400 / 450mm Sweep of any make or model
Exhaust fresh air fan 200/250 mm Sweep of any make or model
Exhaust Fan 300/450 mm Sweep of any make or model
M & L for Preparing the surface, remove the existing painting by scraping, cleaning, filling the cavities and applying 2 coats of spray paint of synthetic enamel white / Brown paint over a coat of red oxide primer, including writing the MES Nos. all as directed for the following:-
Ceiling Fan 1200mm/1400mm Sweep of any make or model
Exhaust Fan 200mm/250mm Sweep of any make or model
Exhaust Fan 380mm/450mm Sweep of any make or model
S/F, Condensor / Capacitor, 240V, AC, suitable for fans all as directed for the following:-
S/F, Ball bearing made out of high carbon steel, equivalent to the original, 6201/6202/6203/6204/NF-8/6205, suitable for any type, any make, any size fans all as directed. Make: SKF / NBC / FAG .
S/F, GM Bush bearing, equivalent to the original, X-I, X-2, X-3, X-4, suitable for any type, any make, any size, fan all as directed.
S/F, Nickel plated mild steel clamps, rubber reel insulator Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size all as directed.
S/F, Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size all as directed.
All as per above but 600mm long
All as per above but 900mm long
All as per above but 1800mm long
S/F, Fan canopy with tightening screw/check nut, made out of PVC, suitable for ceiling fans any type, any make, any size all as directed.
S&F Clutch for ceiling fan made out of GI heavy both end threaded as per sample suitable for 1200 /1400 mm sweep ceiling fan
S&F Magnetic ring of ceiling fans for any type,any make or model all as directed.
S/F, Fan blades made out of 1.2mm thick Aluminium alloy and MS screws duly balanced & spray painted with White or Brown colour, Set of three, suitable for ceiling fans of any type, any make all as directed for the following:-(a) 1200mm/1400mm Sweep
S/F, Fan blades made out of Acrylic / PVC alloy and MS screws duly balance suitable for 450mm wall / cabin fans of any type, any make, all as directed.
S/F, Fan blades made out of thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for Exhaust fans of any type, any make all as directed for the following:-(a) 300mm Sweep
(b) 380mm Sweep
(c) 450mm Sweep
S/F, Fan blades made out of thick Aluminium alloy and MS screws duly balanced & spray painted with approved colour, suitable for 600mm Air Circulator fan of any type, any make all as directed.
Supply & fixing in repair base plate for wall mounting fan any type/ size as per existing size of fan all as specified and directed
Supply & fixing in repair regulator for wall mounting fan any type/ size as per existing size of fan all as specified and directed
Supply & fixing in repair protection cover (jali) complete front and back for wall mounting fan any type/ size as per existing size of fan all as specified and directed
S&F in repairs, Wall fan, 450mm sweep, AC,230V incl T/D old u/s one and depositing to MES store complete all as specified and directed.
S&F in reapirs, PVC fresh air fan, 250mm sweep with louvers, AC, 230V incl T/D old u/s one and depositing to MES complete all as specified and directed.
M&L for making opening in the wall for fixing exhaust fan upto 250mm /200mm, including plastering work & making good the surfaces as directed.
Walk-in-Cooler :- Supply and fixing in replacement of new compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection complete all as directed for 5 Ton indoor type Walk-in-cooler including taking out old us compressore complete all as specified and directed Make : Kirloskar/Tecumsch
M&L for Taking down of walkin-cooler 2.5/5 Ton capacity ton capacity and cleaning / serving of walkin-cooer, overhauling of blower motor replacement of worn out parts, preparation of body for painting one coat of black paint inner side and one coat synthatic enameled paint on the outer cover of walkin-cooler and making of SM/MES No and testing of full load of under relevent item of schedule 'A' and reinstallation at site. Note : Worn out parts shall be measured & paid seperately.
S&F in repair walkin-cooler capacity 5 TR (a) Blower motor 1/6 HP with base / rubber bush for walk-in - cooler all as complete specified and directed. Make AUE / GE Suitable for any make / model
All as per above but Blower motor 1/3 HP for indoor unit split type AC suitable for any Make / any model as per site requirement for walk-in - cooler all as complete specified and directed.
S & F Starting capacitor 70 mfd for walk-in - cooler all as complete specified and directed. make : EPCOS/Havells/TESLA.
S & F Controller/PCB Card Any make / any model for walk-in - cooler all as complete specified and directed.
S & F Inlet sensor for indoor
S & F Sensor for room/outlet/midlet
Renewal of Bimetal overload relay suitable for , Direct Mounting on ML Contactors, (Directly Operated) range up to 32 Amps to match with the existing for walk-in - cooler all as complete specified and directed.
High pressure and low pressure control (HP&LP) switch for F-22 for walk-in - cooler all as complete specified and directed.
AIRCOM (BID ID -3077531)
SIYA ASSOCIATES (BID ID -3071799)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .