| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹58.8 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L-1 | Accepted-AOC AOC | |
| 2 | L-2₹65.1 L+₹5.0 L (8.31%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L-2 | Rejected-Finance Being L-2 | |
| 3 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical Due to valid DD not uploaded | |
| 4 | Rejected-Technical 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | - | Rejected-Technical Not fulfilled eligible criteria as per NIT | |
| 5 | Rejected-Technical FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | - | Rejected-Technical Not fulfilled eligible criteria as per NIT |
Tender Value
₹63 L
EMD Value
₹1.2 L
Closing Date
28 Jun 2023, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
REPAIR AND MAINT OF TRANSFORMER, HT BREAKERS, HT CABLES, HT GOD AND HT EQPT AND E/M WATER SUPPLY INSTAL, CLEANING OF OH AND UG TANKS AND COMPRE REPAIR/ MAINT OF LT PANEL, LT UG CABLE, APFC PANEL AND ALLIED WORKS AT 31 WEU THANE UNDER GE MANKHURD
2023_MES_598131_1
8844/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹1.2 L
Yes
25 Jul 2023
24 May 2023
30 Jun 2023
24 May 2023
28 Jun 2023
14 Jun 2023
Amount
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1616B /National/Sintax
Supply and fix in repair of Cable junction box IP 66/69 "weather proof" (with knockouts for cable entry) box of size 130 x 180 x 77 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channel including providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel cat part No KF1010B /National/Sintax
S& F in replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
S& F in replacement of GI steel tubing medium grade 80 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
M & L for taking down of 400 Amp ATS having two incoming and one outgoing, including opening the cable ends and disconnecting the incoming and outgoing cables and removing the ATS, cleaning and servicing and reinstalling the ATS after carrying out necessary repairs to the ATS main controler, PCB Card, cleaning and earthing all parts and reconnecting the cables all as specified and directed by the Engineer-in-charge.
Supply & Fix in repairs 9 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3Meter with PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) including excavation and earthwork, provision of pvc pipe of size 40 mm dia in the PCC for cable entry complete all as specified and directed. The Fitting Shall Conform to Cat No - PGR0301007 of Polycab or Equivalent from Bajaj/Crompton/Havells
Supply and fix in replacement of Rectangular LED Flood Light 350 Watt with innovative thermal management, multiple optics and equipped with IP66 protection flood light fittings including drivers, pressure die cast aluminium housing, prewired complete. Make - Crompton Cat Part No -LSFO-350-CDL/60 / Havells/ Bajaj/Shakti
Supply and fixing in replacement of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder coated with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. . Make - Havells/ Crompton /Bajaj/Shakti
Supply and fixing in replacement of post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder coated with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. . Make - Havells/ Crompton /Bajaj/Shakti
S & F in replacement of LED Driver 60 Watt Suitable for street light fitting, driver complete all as specified and directed. Make : Cat no X075C070V107FNY1BO of Crompton or Equivalent from Havells /Bajaj
S & F in replacement of LED Driver 30/35 Watts Suitable for street light fitting, driver complete all as specified and directed. Make : Cat no S0DQL1-54-700-40Wof Crompton or Equivalent from Havells /Bajaj
S&F in replacement of MCCB 400 Amps 36 KA, 3 Pole including lugs,nut, bolts. washers etc and dismentling of old MCCB testing complete all as specified and directed by Engineer-in-Charge. Make : Havells/L&T/Legrand/Schneider
-Ditto- all as per item ser No 12 above but MCCB 250 Amps 36 KA, 3 Pole Make : Havells/L&T/Legrand/Schneider
-Ditto- all as per item ser No 12 above but MCCB 200 Amps 25 KA, 3 Pole Make - Havells/L&T/Legrand/Schneider
-Ditto- all as per item ser No 12 above but MCCB 100 Amps 2 KA, 3 Pole Make - Havells/L&T/Legrand/Schneider
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 6 to 16 Sqmm complete with testing till satisfaction of Engr-in-Charge.
-Ditto- all as per item No 16 here-in-before but 2/4 core 25 to 50 Sqmm size -do-
-Ditto- all as per item No 16 here-in-before but 3.5/4 core 70 to 95 Sqmm size -do-
-Ditto- all as per item No 16 here-in-before but 3.5/4 core 120 to 185 Sqmm size -do-
Supply& fixing in repairs of Chequered plate Fe 410-W(Gde-E- 250)A quality- for cable trenches, ladders including equal angle trench frames, including cutting as per requirement of site, square cut or notched (ordinary and counter sunk) forming holes, without any including providing handles complete all as specified and directed
Supply& fixing in repairs for mild steel work confirming to Fe-290, GdeE-165 in stairs/ladders including stringes, treades, landing, balusters, hand rails etc including applying two coat of paint over one coat of red oxide complete all as specified and directed.
M&L for reinforced cement concrete nominal mix M-20 (using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed. (Note - Reinforcement and form work will be measured and paid separately).
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 10 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8mm dia bars as in binders, spacers, strippus including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed.
M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished flat surfaces of concrete, complete all as specified and directed.
Dismantling old PCC Pole/ Steel Pole and Supply, Fixing and connection of hot dip galvanised octagonal poles of height 6 mtr with 130mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed stone by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified..
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid Note :- Serviceable cable cover obtained from Ser Item No 65 to 69 shall be reused.
Dismantling of PCC foundation / pole coping from ground level all as per specified.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
M&L for locating of faults of LT under ground cable XLPE upto 400 Sqmm size by using computerised / primary current injection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Notes:-(i) Excavation, earth work, sand cushioning, PCC cover etc will be measured and paid separately under relevant items of BOQ. (ii) Cable joint will be measured and paid separately. (iii) Additional length of cable required at site for jointing will be measured and paid separately.
Supply and Laying or fixing or passing through pipe, XLPE ISI marked insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 240 Sqmm 3.5 core including necessary connection and providing cable lugs as required including disconnection/taking down of existing cable complete all as specified.
-Ditto- all as per item No 36 above here-in-before but 150 Sqmm 3.5 Core -do-
-Ditto- all as per item No 36 above here-in-before but 95 Sqmm 3.5 Core -do-
-Ditto- all as per item No 36 above here-in-before but 16 Sqmm 4 Core -do-
-Ditto- all as per item No 36 above here-in-before but 10 Sqmm 4 Core -do-
M&L for Preparing surfaces of steel tubular swaged pole LT with scraping out old paint by emmery paper, caustic soda complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint base and stripping with black paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height all as directed by Engineer in Charge.
Equipment and labour for servicing of ACB including drawing/taking out from LT Panel, cleaning the Contacts, checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unsversiable spring units for proper function and carrying out ratio test by applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at site Note : The Contractor shall brought all T & P and testing equipments at his own arrangements.
Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob complete all as specified and directed.
M & L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing Capping, fuse units and cleaning and testing complete all as specified and directed.
Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating, Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system
All as per item No 46 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32 & Cat no - CS94111 of L & T or equivalent from Schnider Electric, ABB/ C&S
All as per item No 46 above but Contactor Three Pole 415 volts 40 Amps AC 3 RatingConforming to Type - MNX - 40 & Cat no - CS94190 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 46 above but Contactor Three Pole 415 volts 50 Amps AC 3 Rating Conforming to Type -MNX - 50 & Cat no ST19001 of L & T or equivalent from Schnider Electric/ABB/ C&S
All as per item No 46 above but Contactor Three Pole 415 volts 70 Amps AC 3 Rating Conforming to Type - MNX - 70 & Cat no - ST19002 of L & T or equivalent from Schnider Electric/ABB/ C&S
Supply and fix Power Capacitors of Rating 25 KVAR 415 Volt in repairs Naturally air cooled Double dielectric heavy duty, MPP type 440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified.
All as per item No 51 above but Power Capacitors of Rating 20 KVAR 415 Volt
All as per item No 51 above but Power Capacitors of Rating 15 KVAR 415 Volt
All as per item No 51 above but Power Capacitors of Rating 10 KVAR 415 Volt
All as per item No 51 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
All as per item No 51 above but Power Capacitors of Rating 5 KVAR 415 Volt
Supply and fix in repair add on Blocks suitable for Power contactors of range 25 Amps to 140 amps (MNX 25 to MNX 140 including making addition/Alternation to existing Wiring/circuit system all of Make- L&Tor equivalent from Schnider Electric/ABB/ C&S
Maint and cleaning of Sub stations inside and out side area and removing of creepers raised along with sub station including surface dressing around the sub station not less then 3 mtr from out side fencing and removing the all waste material from site and Chemical spray inside and out side area of Sub station. Note:- T & P will be arreanged by contractor at his own arrangements.
Repair & Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226/Petrol, tightening of all joints in bus bar, checking of earth and neutral voltage and make a record, replacement of u/s nuts/bolts/washers including replacement of corroded glands, lugs/ thimbles and tightening them properly all as directed by Engineer-in-charge.
Labour only for removing of creepers raised along with LT panels/feeder piller box etc surface dressing around the LT panels not less then 1.5 mtr in radius and removing the all waste material from site including supplying and spraying chemical for destruction of grass as required and complete all as directed by Engineer-in-Charge.
S & F in replacement of Voltmeter Digital type ,3 Phase Volts of size 96x96mm. Make : AE/L&T/Schenider
S & F in replacement of Ammeter Digital type of 0-400 amps capacity of size 96X96mm. Make : AE/L&T/Schenider
S & F in replacement of Phase indicating lamp neon type complete with holder assy RYB. Make : AE/L&T/Havells/Indoasian
S & F in replacement CT coils of ratio 400/5 Amps, 15 VA class -1 as per IS- 2705/92. Make : AE/L&T/Havells/Indoasian
M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well rammaing watering finishing suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top including removal of surplus soil all as directed.
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc all as Directed. Make :- POLYCAB / KEI / HAVELLS
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers and LED 36/70 watt after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LED will be measured and paid separately on respective item of Sch 'A' here-in-after].
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 150 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete all as directed. Make : Philips/Bajaj/Crompton/Benlo/Shakti
S&F in repair of building Security light fitting 30/35 Watt made up of pressure die cast aluminium body with mid power LED as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make : Philips/Bajaj/Crompton/Benlo/Shakti
M&L in repairs for 24 Hrs 240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make legrand Cat No. 412780 or equivalent of Havells L&T/Indo Asian as approved by GE
Filtration and dehydration of transformer oil using ON-LINE filtration plant to remove moisture and carbon contents to achieve dielectric strength of oil not less than 50KV in 4mm gap, Oil samples of each transformer, OCB and OFS etc are to be tested before and after filtration test, results to be recorded on a printed format and also painting the date of test on the equipment with synthetic enamel paint all as specified and directed and also including disconnecting the HT and LT cables and cleaning the bus bar surfaces and reconnecting the cables by providing copper washers, bolts, nuts etc all as specified and directed. Notes:- (i) Oil required for topping up for filtration will be measured and paid separately under respective item of BOQ . (ii) The quoted rates shall also be deemed to include for proper cleaning of the tank surfaces to make the same free from sludge etc. (iii) The qty of oil payable under this item shall be the net qty reused for filling after dehydration and filtration having dielectric strength not less than 50 KV in 4mm gap
Filtration and Dehyderten of oil of 11 KV CTPT by ON-LINE filtration plant to remove moisture and carbon contentents to acheive dielectric strength of oil not less than 50KV in 4mm gap and producing test result on records before and after filtration of each CTPT and also including servicing and painting the entire unit and reconnnecting the same all as specified and directed, Note - Oil required for topping up for filtration will be measured and paid separately under respective item of BOQ .
Material and Labour for supply and filling of Transformer insulation oil as per IS 335-1993 having die electric strength minimum 50 KV in 4mm gap for topping up in transformer, OCB, OFS etc all as specified and directed, Make: SAVITA/POWER OIL/APAR.
M&L for preparation of old painted surfaces of transformer 100 to 315 KVA capacity, 11KV-22KV/433 Volt including removing of any oil spillage and applyIing two coats of anti corrosive paint of shade as per existing, complete all as specified and directed.
M&L for preparation of old painted surfaces of transformer 400 to 630 KVA capacity , 11KV-22KV/433 Volt including removing of any oil spillage etc and applying two coats of anti corrosive paint of shade as per existing, complete all as specified and directed.
M & L for taking out unserviceable LT bushings with stud etc and replacing LT Bushings complete with and including copper/brass stud, rubber gasket, brass bolts, brass nuts, cable lugs etc for 11 KV - 22 KV/0.433 KV transformer of rating upto 315 KVA, complete all as specified and directed.
M & L for taking down/opening top cover of 11 KV - 22KV/0.433 KV transformer of rating upto 315 KVA, replacing the gasket of top cover and refixing the top cover, including testing, complete all as specified and directed.
M & L for taking out unserviceable HT bushings with stud etc and replacing HT Bushings complete with and including copper/brass stud, rubber gasket, brass bolts, brass nuts, cable lugs etc for 11 KV/0.433 KV transformer of rating upto 315 KVA complete all as specified and directed.
M & L for taking out unserviceable HT bushings with stud etc and replacing HT Bushings complete with and including copper/brass stud, rubber gasket, brass bolts, brass nuts, cable lugs etc for 22 KV/0.433 KV transformer of rating upto 315 KVA complete all as specified and directed.
M & L for taking out unserviceable LT bushings with stud etc and replacing LT Bushings complete with and including copper/ brass stud, rubber gasket, brass bolts, brass nuts, cable lugs etc for 11 KV /0.433 KV transformer of rating 400 to 630 KVA complete all as specified and directed.
M & L for taking down/opening top cover of 11 KV - 22KV/0.433 KV transformer of rating 400 to 630 KVA, replacing the gasket of top cover and refixing the top cover including testing, complete all as specified and directed.
M & L for taking out unserviceable HT bushings with stud etc and replacing HT bushings complete with and including copper/ brass stud, rubber gasket, brass bolts, brass nuts, cable lugs etc for 11 KV/0.433 KV transformer of rating 400 to 630 KVA, complete all as specified and directed.
M&L for locating faults of HT under ground cable PILCA/XLPE 11 KV/22KV upto 300 Sqmm size by using computerised / primary current injection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site. Notes:-(i) Excavation, earth work, sand cushioning, PCC cover etc will be measured and paid separately under relevant items of BOQ. (ii) Cable joint will be measured and paid separately. (iii) Additional length of cable required at site for jointing will be measured and paid separately.
M&L for High pot charges during locating faults of HT under ground cable all as directed by Engr -in- Charge
Material only for heat shrink type straight through cable jointing kit suitable for 3 Core 50- 95 sqmm 11 KV earthed XLPE cable complete with and including jointing materials, accessories and thimbles etc, complete all as specified and directed.
Material only for heat shrink type straight through cable jointing kit suitable for 3 Core 120-185 Sqmm 11 KV earthed XLPE cable complete with and including jointing materials, accessories and thimbles etc, complete all as specified and directed.
Material only for heat shrink type straight through cable jointing kit suitable for 3 Core 120-240 Sqmm 22 KV earthed XLPE cable complete with and including jointing materials, accessores and thimbles etc, complete all as specified and directed.
Supply only in repairs indoor heat shrink type end termination cable jointing kit for 11 KV (Earthed) grade cable complete with and including jointing materials, accessories and thimbles etc suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed.
Supply only in repairs indoor heat shrink type end termination cable jointing kit for 11 KV (Earthed) grade cable complete with and including jointing materials, accessories and thimbles etc suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 240 Sqmm, complete all as specified and directed.
Material only in repairs indoor Heat shrink type end termination cable jointing kit for 22 KV (earthed) grade cable complete with and including jointing materials, accessories and thimbles etc suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm, complete all as specified and directed.
Material only in repairs out door heat shrink type end termination cable jointing kit for 22 KV (earthed) grade cable complete with and including jointing materials, accessories and thimbles etc suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm, complete all as specified and directed.
Taking out existing 11 KV/22 KV grade defective cable of any type and size from the trenches and from any other locations (including taking out of cable covers, pipes etc) complete all as directed. Note: Excavation and earth work shall be measured and paid for separtely.
Supply, laying and testing in trenches, road crossing, through pipes, ducts etc, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty ) with aluminium conductor, 11000 volts grade (earthed), cross sectional area 120 Sqmm X 3 core, complete all as specified and directed.
Supply, laying and testing in trenches, road crossing, through pipes, ducts etc, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty ) with aluminium conductor, 11000 volts grade (earthed), cross sectional area 185 Sqmm X 3 core, complete all as specified and directed.
Supply, laying and testing in trenches, road crossing, through pipes, ducts etc, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cable (heavy duty ) with aluminium conductor, 22000 volts grade (earthed), cross sectional area 120 Sqmm X 3 core, complete all as specified and directed.
Supply and laying unreinforced precast factory made concrete cable cover, class HV, Type -I, flat, size 300mmx 180mm x40mm, complete all as specified and directed.
Supply & laying reinforced precast factory made concrete cable cover, class EHV, type -I with peak size 450mm x 230mm x 50mm complete all as specified and directed.
Supply & fix in replacement Silica Gel Breather with silica gel for 11 KV to 22 KV Transformer of Rating upto 630 KVA, complete all as specified and directed.
Overhauling of HT OCB 11 KV, 400 Amps, 250 MVA of Make Crompton Greaves/MEI/GEC/ Alstom installed at various locations after taking shut down from department and opening both incoming and outgoing connections, dismantling complete Circuit Breaker after detaching oil tank and draining out oil in a separate container and cleaning of oil tank throughly and carrying out the following repair work :- (i) Taking out complete parts of OCB separately viz. like ARC control pot assembly, jack ring , contact main, TULIP contact finger assembly, terminal bushing, moving contact block, fixed contact block, pick off spring assembly, moving ARC, Contact ARC, assembly of main moving contact, speed control device assembly etc and checking the same for its serviceability/ suitability for refixing, cleaning the OCB externally and internally including all parts thoroughly as per standard practice (also cleaning the male female contacts with emery papers and insulator with CRS spray and applying petrolium jelly/grease to the moving parts), reassembling complete parts of OCBs including replacement of existing unserviceable parts /components all as approved and directed. (ii) Taking out complete parts of Truck & Hoist Assembly, after removing old grease checking the same for its suitability/ serviceability and reassembling complete truck and hoist assembly after replacement of defective parts all as approved and directed including greasing and oiling the complete mechanism as per standard practice. (iii) Servicing of dependent/independent mechanism and spring charging mechanism including replacement of spares comprising of scope as under :- (a) Recommissioning including testing of HT OCB for overload setting and adjustment. (b) Recommissioning of complete Truck and Hoist assembly all as directed (iv) Checking/testing/servicing of tank assembly/barrier, solenoid machianism, trip unit assembly, BUS bar spout epoxy cast side entry cable base busing, arrangment with drawable type PT assembly of male female housing etc complete including repalcement of defective parts with new all as directed.
(v) Over hauling of HT panel of each OCB including cleaning of bus bar chamber, CT's and painting all exposed surfaces with one coat of insulation paint of same colour and replacement of control fuses, replacement of panel heater and bus bar insulators all as directed and painting Alphabet/Numbers with bold letters upto 5 cm height with black colour. (vi) Checking/repairing the auxillary wiring. (vii) Testing of relays, CT & PT units and relay settings etc. NOTES: (i) Cost of all the materials, repairs and works as specified above as well as all the other elements (except followings) to make the OCB's fully functional shall be deemed to be included in the quoted rates :- (a) Cost for supply only of the components/parts/spares catered for under item Nos 164 to 171 to the extent required and operated here-in-after.
Supply only OCB Top plate insulator Bus Bar side with current carrying parts for 11 KV OCB, Make Crompton Greaves/MEI/GEC/Alstom, capacity 400 Amps, 250 MVA rating, complete all as specified and directed.
Supply only spout insulator (Epoxy) for OCB Trolley complete with current carrying parts for 11 KV OCB, make Crompton Greaves/MEI/GEC/Alstom, capacity 400 Amps, 250 MVA rating, complete all as specified and directed.
Supply only spare of Main Contact Male suitable for R, Y, B Phase for 11 KV OCB of make Crompton Greaves/MEI/GEC/ Alstom, capacity 400 Amps, 250 MVA rating, complete all as specified and directed.
Supply only spare of Main Contact Female for R, Y, B Phase for 11 KV OCB of make Crompton Greaves/MEI/GEC/ Alstom, capacity 400 Amps, 250 MVA rating, complete all as specified and directed.
Supply only 11 KV resin cast Single core single ratio Current transformer of ration 60/5Amps class C, 15 VA burden, including carrying out testing.
Supply only PT 11 KV/110 V AC, 100 VA, suitable for existing PT of OCB/VCB.
Supply only vacuum bottle type VG 2 of 11 KV VCB trolley rating 350MVA, current rating 630 Amps & Conforming to cat no MST10SG200300NA of Schnider or Equivalent from ABB/ SIEMENS
Supply only Single phase Circuit Spout R, Y, B Phase Conforming to Cat no - MEP-39-32187 of Schnider Electric or Equivalent from ABB/SIEMENS
Supply only Single phase Bus Bar Spout for R & B Phase Conforming to Cat no - MEP-39-32185 of Schnider Electric or Equivalent from ABB/SIEMENS
Supply only Single phase Bus Bar Spout for Y Phase Conforming to Cat no - MEP-39-32186 of Schnider Electric or Equivalent from ABB/SIEMENS
Supply only Copper Flexible connections 800 Amps Capacity suitable for VG2 VCB trolley, conforming to Cat no MCU39S4126302FNof Schnider or Equivalent from ABB/Siemens
Supply only Closing coil operating on 30 Volt DC for VCB trolley conforming to Cat no ECO39SN134700FN of Schnider or Equivalent from ABB/Siemens
Supply only Trip coil operating on 30 Volt DC for VCB trolley conforming to Cat no ECO39SN133900FN of Schnider or Equivalent from ABB/Siemens
Supply only Silver plated copper Isolating contact flat type 800 Amps capacity, including mounting screws conforming to Cat no MVIK00190-01 of Schnider or Equivalent from ABB/Siemens
Supply only Insulator for Bus Bar Support, Conforming to Cat no MEP-39-37399 of Schnider or equivalent from ABB/Siemens
Supply only Drive beam conforming to cat no MSM39S0118600FN of Schnider or equivalent from ABB/Siemens
Supply only buffer for opening spring, conformin to cat no MVIJ0098-01 of Schnider, or Equivalent from ABB/Siemens
Supply only buffer for closing spring, conformin to cat no MVIJ0056-01 of Schnider, or Equivalent from ABB/Siemens
Supply only Spring charging motor with gear box, the motor shall be operating on 110 V AC supply.conformin to cat no MVIJ00157-01 of Schnider, or Equivalent from ABB/Siemens
Supply only local remote switch for vaccum circuit Breaker
Supply only Indicator lamp ,30 Volts, pin type as per sample.
Supply only Flange Tank Gasket suitable for existing size for OCB.
Supply only Earth fault and Over current relay suitable for existing VCB.
Supply only PT primary fuse for 11 KV, 3 Amp.
M&L for dismantling HT 22 KV SF6 braker Make - ABB, open the cable termination compartement, Dismantle the HT cable temination burnt spout insulator, copper termination rod, rubber bushings and CTs and replace with new spout insulator, rubber bushings, CTs and copper cable termination rod, after replacing the above components, clean the splashes over compartment, servicing the entire braker, testing the braker standard parameters and set the Earth fault and over current relay all as per existing setting, after carryout above repairs, Megerring the braker for Phase to Phase and earth to phase, earth fault values with HT Megar, clean all the splashes over compartment completely , clean all spout insulator , Rubber insulator etc, complete all as specified and directed. Note : (a) Technician to be engaged for carrying out Maintenance Shall have HT Licence (b) Prior Liaison shall be done with the supply agency for HT Power Shut Down.
M&L for dismantling HT 22 KV Fuse from fuse compartment of SF6 braker of Make - ABB, replacing with new fuse of rating IN- 16 Amps, U N -24 KV, 13 - 55 A, 11- 63 KA, including Cleaning the fuse compartment, complete fuse shall be of Cat No 1YMB531004M0003 of ABB Make. Note- a) Technician to be engaged carrying out Maintenance Shall have HT Licence. (b) Prior Liaison shall be done with the supply agency for HT Power Shut Down.
M & L for servicing IDMT relays (Two Nos over current and one No earth fault relays) fixed in 11 KV HT panels for primary and secondary injection and calibration of all the relays and setting the relay tripping timings in advance to match the outgoing load on the Incoming and outgoing feeders, complete all as specified and directed.
Supply and fix in replacement of old unserviceable battery charging unit Input - 230 VAC and Out Put 30 V DC, Maximum 10 Amps Current Out Put for charging of battery bank.
Supply and fix in replacement battery back up unit including of 2 Volt, 100 AH VRLA battery - 15, interconnection link for connecting batteries to achive 30 Volt out put. Make of Battery shall be Exide, Amaron, Amco
Material and labour for scrapping of old paint and applying two coats of Aluminium paint over a coat of Red oxide all for 22 KV two pole structure including GOD & operating rod
M&L for earthing complete with copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal ground level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I including necessary excavation and earthwork, PCC chamber, CI cover, GI protection and watering pipe, pipe 25mm bore, sight grade funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materials, complete all as specified and directed. Notes: (1). Cost for provision of 7.5 Rm Copper strip and G I protection pipe 25mm bore, light grade shall also deemed to be included in quoted rates. (2). Earth resistance of earth pit should be less than 0.5 Ohms. On testing, if the desired earth resistance is not obtained, the earthing will be redone at no extra cost. (3) Rate quoted by the tenderer shall also be deemed to include salt & Charcoal fillings upto & above 450 mm top of Copper plate.
S&F copper strip of size 20 x 3.00mm including welding, brazing and taking down of old copper strip as required at site, complete all as specified and directed.
Material and labour loose filling with graded coarse stone aggregate 40 mm for out type sub Stations not exceeding 15 Cm thick complete all as specified and directed.
Dismantling air break gang operated switches vertical/horizontal mounted incl insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc complete all as specified and directed.
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 22000 Volts grade, 50 Hz, with 9 insulator of rating upto 200 Amps complete all as specified and as directed.
Supply and fixing drop out fuse single pole mounted on insulator, 22000 Volts grade double pole steel frame of current rating 50 Amps including taking down existing DO fuse complete and removing from site complete all as specified and directed.
Supply only brass terminal plate for mounting male contact of air break switch insulator including GI nuts and bolts washers etc as required complete all as specified and directed.
Supply only male contact / female contact for air break switch
Supply only post insulator for air break switch with metal part suitable for HT 22 KV conforming to IS-5572-1972
Supply only Post insulator double stack for air break switch suitable for HT 22 KV
Supply only DO insulator suitable for 22 KV with metal part conforming to IS-5572-1972.
Supply only high conductivity copper wire mesh jumper 200 Amps rating for air break switch, 22 KV complete all as specified and directed.
Supply only dropout fuses top/bottom contact
M & L for Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11m long) conforming to IS-2713 (Part-I & II) including painting of pole with two coats of aluminum paint over a coat of red oxide primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black paint over a coat of red oxide primer upto 1.5m from bottom of the pole including numbering of poles as directed complete all as specified and directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective item)
M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
M & L for servicing (as described below) for outdoor type, HT 11 KV/433 Volt, Dry type Transformer of capacity upto 1000 KVA and carrying out the following repair work :- (a) Servicing, cleaning, inspecting and testing for proper functioning of operation. (b) Servicing of de-hummidifying of core coils assly by hot air blower. (c) Cleaning of the coils of dust & other paricles. (d) Retightening of all the tie rods & core bolts. (e) Checking gaskets for the HT/LT insulators & Replacing the same. (f) Internal touch up for the enclosures & external touch up paint.
sapana enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .