Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-Finance Lowest | |
| 2 | L2₹26.2 L+₹2.4 L (10.1%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹37.0 L+₹13.2 L (55.7%)Rejected-Finance 86 TOLLYGUNGE CIRCULAR ROAD KOLKATA WEST BENGAL 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance 3rd Lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Insufficient Documents Submitted | |
| 5 | Rejected-Technical | - | Rejected-Technical Insufficient Documents Submitted |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
3 Jun 2022, 5:00 pmClosed
Office of the EE KED Writers Buildings
New Building Erstwhile CGA Office 1st. Floor Writers Buildings Kolkata 700 001
SITC of Ductable Split Air Conditioning system including allied Electrical Installation Work for the Agricultural Department at 1st floor of Jessop Building under Writers Buildings Electrical Section VI PWD Phase I SITC of AC MAC
2022_WBPWD_381213_1
WBPWD/EE-KED/e-NIQ-02/2022-23
Open Tender
A/C ORG
Item Rate
30 days
Jessop Building
Please refer Tender documents.
6 documents required · 6 mandatory
₹58,000
Yes
Kolkata Electrical Division Writers Buildings
17 Jun 2022
19 May 2022
6 Jun 2022
19 May 2022
3 Jun 2022
25 May 2022
23 May 2022
Amount
Supply & Delivery of Ceiling Mounted Ductable DX type Air Conditioning Unit with 198000 btu/hr Cooling capacity, 6600 CFM Air Flow, with 2/3 Nos.Scroll compressor, 400V/3 PH/50 Hz Microprocessor based Controler of 16.5/17.0TR nominal capacity with R-410A/R407C Refrigerant. (Make-Hitachi/O-General /Carrier/Voltas/Daikin).
Installation, Testing & Commissioning of the above Air Conditioning systems with all necessary accessiores for hanging Indoor & Outdoor Units For 16.5/17.0 TR Ductable Units.
S&F of Copper refrigeration pipe line for liquid and suction line with hard drawn copper piping with supports & Brackets Cu. Pipes Suction line dia 15.88 mm.
Cu.HD Pipes Suction line dia 22.2 mm with 13mm thick nitrile insulation.
Supply and fixing of necessary electrical arrangements of Air Conditioning Units, PVC insulated FRLS grade Copper cable for connection betweeen indoor and outdoor units, 1.1 KV grade. 3 core x 2.5 mm² (Make- Polycab/ Haavells/KEI/RR/Reputed ISI make).
4 core x 2.5 mm² (Make- Polycab/ Haavells /KEI / RR/ Reputed ISI make).
Supply & fixing of dia UPVC drain pipes with all necessary hanging arrangements & 9mm Heat Retardant Thermal insulutaion. Dia 32mm
Dia 25mm
SITC of Site Fabricated G.I Sheet Metal Square Air Duct complete with Angle, Fastner, supports, dampers etc. as per specifications & site requirement. For 24 SWG
For 22 SWG
Supply and fixing Heat Retardant Open cell Class'O' 9mm thk Nitrile Rubber insulation inside Supply Air duct.
Supply and fixing Heat Retardant closed cell Class'O' 9mm thk Nitrile Rubber insulation with AI Foil Faced Outside Supply Air duct.
Supply & Fixing of Liner type AI Powder Coated Continuous Grill with VCD for Supply Air.
Supply & Fixing of Liner type AI Powder Coated Continuous Grill without VCD for Return Air.
Supply and Fixing of Fresh air Volume Control Damper.
Supplying & fixing of Return Air Diffusers without VCD
Supply & Fixing of Fusiable Link Fire Damper,Galvanized Steel Sheet with 125 GSM Zink Coated, Certified by CBRI ( U-555, 1995),with minimum fire rating not less than 120 min, must be Fusiable Link Spring with 74°C Temerature rating Ul Listed
Supply and Fixing of Motorized Volume Control Damper.
Civil Work like- Wall Cutting, Wall finishing painting etc for this job as required as per direction of EIC.
Schafolding & lifting, Shifting of Ac maching IDU, ODU.
Providing and fixing fire retardant nonporous double layer flexible connection between IDUand duct.
Supply & fixing of 25 mm thick Nitrile rubber Accoustic insulation UNDER-DECK complete with all accessory as required.[Make: Armacell/K-flex/A-flex] as per direction EIC.
SITC of heavy duty anti vibrational pad to protect the system from any kind of unwanted vibration.
Supply & Fixing of Fresh Air Damper with Bird Screen as per direction of E.I.C (Make:Primier/Air Kolkata/Air Primier/AFI).
Supplying, fabrication & fixing 4 Nos. M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making Base Frame table type for installation of Exhaust Cabinet incl. drilling 2 nos holes in each channel. fabricated with 4 Nos.Baricated the same for maintenance horizontal angle of 50 mm x 50 mm x 6 mm Inscl Platform as per direction of E.I.C.. Area of Platform 9mtr x 1.8mtr for Placing the Exhaust Units including scaffolding charges.
Supply & Fixing of IDU & Duct Covered with 3mm thick ACP Board (Make:Aludecor/Protap Bond) Coplete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Chrages for Trap door with ACP Board (Make:Aludecor/Protap Bond)Coplete with linkages, levers, fittings, supports, all accessories for IDU Maintenance make with ACP Board as per direction of E.I.C.
NATIONAL AIRCON
Lyric International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .