Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.6 LAccepted-Finance NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-Finance Admitted | |
| 2 | L2₹36.6 L+₹1.1 L (2.96%)Accepted-Finance 6 1ST CROSS 1ST MAIN OLD POLICE STATION ROAD LAKKASANDRA BANGALORE 560 030 | BENGALURU URBAN | KARNATAKA | 560030 | L2 | Accepted-Finance Admitted | |
| 3 | L3₹37.8 L+₹2.3 L (6.34%)Accepted-Finance | L3 | Accepted-Finance Admitted |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
14 Nov 2023, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
SPECIAL REPAIR/IMPROVEMENT OF TREATMENT WING OF BLDG NO P-1 AT AFIDS AT CHAF BANGALORE
2023_MES_621592_1
8160/GE/61
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BANGLAORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹88,000
1 Dec 2023
4 Oct 2023
20 Nov 2023
4 Oct 2023
14 Nov 2023
25 Oct 2023
5 Oct 2023 - 11 Oct 2023
Amount
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
M&L for vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm light shed, in floors etc laid over and including 15mm thick screed bed or bedding layer of CM (1:4), set & jointed in neat cement slurry & pointed in white or coloured cement to match all as specified.
M&L for coloured glazed ceramic tiles 450x300x7 mm thick, on vertical surfaces such as skirting, dados and rises to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat of CM 1:4 all as specified and directed
M&L for 25 mm thick Cement concrete type B0, 1:2:4 (using 12.5 mm graded stone aggregate) in sub base of flooring
Dismantling any type wall and ceiling boards (fibre, pulp, insulation etc) or isulatio board / slabs/bankets any thickness including cover fillets all as specified and as directed.
S&F armstrong 9mm PVC laminated gypsum board false celing of 600x600 mm withprelude 24x32x300mm main tee and 24x27x1200 mm cross tee and 24x25x600 cross tee and wall angle of 19x19x300mm in false ceiling all as directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, making good disturbed surfaces and removing materials from site of work complete all as directed by the Engr-in-Charge.
M & L for Powder coated Aluminium windows of three tracks outer frame top, side sections, bottom frame(track) with guide track of size 92.5x31x1.50mm with sliding window shutters two nos with glass and one no with wire mesh(total 3 nos shutter) frame top and side bottom section with wheel track and inner locking section of size 40X18X1.5mm inculding glass 4 mm thick and aluminium wire cloth, 0.45mm nominal dia wire and average width of aperture 1.40mm complete all as specfied and dierected by Engg-IN-Charge
S & F Powder coated Aluminium Frame work for grills Deco-grill Model DG-104(10mm) making shape and riveted with rivets and fixed with suitable channel complete necessary fixing arrangements etc.,completed and directed by Engr-In-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built upstandard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief. Note : All the aluminium sections provided under this item shall be measured and converted into weight for payment with the designated unit weight mentioned in the manufactures catalouge for the corresponding aluminum sections/fittings.
S&F Anodised aluminium door shutters, aluminium section Powder Coating (minimum thickness of powder coating 50 micron) weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc complete all as specified.
Supply and fixing 12 mm prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations
S&F 5.5 mm thick sheet glass, ordinary quality, fixied with necessary glazing clips, in squares exceeding 0.5 Sqm in each panel all as specified and as directed.
S&F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
M&L for double action floor spring, hydraulically regulated, made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass and other parts made of heavy duty mild steel, complete all as specified and as directed.
S&F 10mm thick and above Toughened glass single door shutter with two Nos of steel Handle (of size 300mm long and 20mm dia) fixed with all necessary arrangement including hydraulically regulated floor spring double action type and pivot hinges all as specified and as directed by the Engr -in-Charge
Demolition of brickwork or stone /boulder masonry, built in cement mortar incl. all quoins, arches pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles etc.complete all as directed.
Demolition of cement concrete (reinforcement) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as directed.
M&L for Pre cast cement concrete block masonry with soild blocks, type C1 (1:3:6) using 20mm graded aggregate exc 10 cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubing down with water etc complete all as specified and as directed
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement morter 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Complete removal of existing treatement on wall and applying two coats of oil emulsion distemper over one coat of alkali-resistant priming paint whiting primer over and including 3mm thick wall care putty all as specified.
M&L for preparing new plastered surfaces of wall and applying two coats of oil emulsion distemper over one one coat of alkali-resistant priming paint whiting primer over and including 3mm thick wall care putty all as specified.
M&L for framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc.similar work conforming to Fe.290.Gde-E-165.all as specified and as directed by Engr-in-Charge.
Preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and directed.
S&F 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor,including dismantling of old pipe (sewage/rain water/any type) complete all as specified and as directed .
S&F 75mm bore PVC (SWR) bends any radius
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings & fixtures such as switches, ceiling rose, pendants, regulators, sockets, ceiling roses,pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified & as directed.
Taking down ceiling fans from ceiling, dismantaling blades & refixing of the same including provision of cable from ceiling rose or connector to fan all as specified and directed.
Point wiring with cable of PVC insulated FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade in and including medium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements concealed in Stone walls / brick masonary walls /ceilings / floors etc by cutting chasis in existing stone/ brick masonary, including fixing top cover /PVC /MS Modular type junction boxes fixing in Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for the following :-
One light controlled by one single pole 5 Amps switch
One Ceiling fan point controlled by one single pole 5 Amps switch
One Exhaust fan point controlled by one single pole 5 Amps switch
One 3 pin switch socket out let point 5 Amps switch on independent board
One 3 pin switch socket out let point 5 Amps switch on same board
Point wiring with cable of PVC insulated FRLS copper multistranded conductor 2.50 sqmm 1100 volts grade in and including medium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements concealed in Stone walls / brick masonary walls /ceilings / floors etc by cutting chasis in existing stone/ brick machinery, including fixing top cover /PVC /MS Modular type junction boxes fixing in Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed for the following :- NOTE : Chasis/ groove cutting shall be measured and paid separately under relevant items.
Supply and fix Modular switch , 1 Module single pole one way 10 Amps.
Supply and fix Modular switch , 1 Module single pole one way 16 Amps.
Supply and fix modular socket , 2 Module 6 Amps, 2/3 pin, 240 volts Ac 2/3 pin combined all as specified and directed at site.
Supply and fix modular socket , 2 Module 6/16 Amps, 2/3 pin, 240 volts Ac 2/3 pin combined all as specified and directed at site.
Supply and fixing of modular type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm.
Supply and fixing of modular white cover plate with frame, 1 module
Supply and fixing of modular white cover plate with frame, 2 module
Supply and fixing of modular white cover plate with frame, 3 module
Supply and fixing of modular white cover plate with frame, 4 module
Supply and fixing of modular white cover plate with frame, 6 module
Supply and fixing of modular white cover plate with frame, 8 module
Supply and fixing of metal flush box 1/2 module
Supply and fixing of metal flush box 3 module
Supply and fixing of metal flush box 4 module
Supply and fixing of metal flush box 6 module
Supply and fixing of metal flush box 8 module
Supply and fixing PVC ceiling rose 65 x 50 mm surface type with 3 terminals all as specified and directed.
Supply and fixing of Sheet metal enclosures with socket plug top & MCB, Single pole & neutral enclosure with a 2 pin & earth plug & socket complete with one single pole MCB 20 A
Supply and fix in repairs office LED Luminaires recessed type 36 watts, LED 600 x 600 mm grid ceiling incl connecting up with PVC sheathed 1.5 sqmm 2 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repairs office LED Luminaires batten type 20 watts, LED incl connecting up with PVC sheathed 1.5 sqmm 2 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in repairs office LED Luminaires batten type 10 watts, LED incl connecting up with PVC sheathed 1.5 sqmm 2 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Cutting into or through the stone walls / brick walls built in cement mortar or cement lime mortar and walls of cement concrete suitable size for housing for sunk box using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and directed.
Cutting chasis, pinning in Stone walls/ brick walls etc. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc, for concealed conduit wiring a into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 25mm dia conduit pipe using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and directed.
Supply and fix sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 4.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealed fixed in stone wall, floor or ceiling etc by cutting chasis in existing stone/ brick masonary inc 4.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC Conduit and two run of copper conductor together taken as one length for measuring unit length.
Supply and fix sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 6.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealed fixed in stone wall, floor or ceiling etc by cutting chasis in existing stone/ brick masonary inc 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC Conduit and two run of copper conductor together taken as one length for measuring unit length.
Supply and fix sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 10 sqmm in and including non-metallic rigid PVC conduit and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc by cutting chasis in existing stone/ brick masonary including 10.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC Conduit and two run of copper conductor together taken as one length for measuring unit length.
Supply and fix sub main wiring with Four single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 10.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealed fixed in stone wall, floor or ceiling etc by cutting chasis in existing stone/ brick masonary inc 10.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : Two runs of earth continuity conductor,one run of PVC Conduit and Four runs of copper conductor together taken as one length for measuring unit length.
Material and labour for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground ( earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level, connected to galvanised earth lead wire 4.00 mmdia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indiacted including testing on completion.
Earth Continuity Conductor or main earthing lead fixed to wall on batten or recess or chasis or buried in ground or drawn in conduit / pipe or fixed for earthing etc. of size 4.00 mm dia galvanised iron or steel wire all as specified and as directed.
S&F in repairs Sheet metal enclosure for DB's double door SPN, 8 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 240V, complete all as specified and directed. Including taking down old unsv from exiting place.
S&F in repairs Sheet metal enclosure for DB's double door TPN, 8 ways when MCBs to be used single pole and neutral,deep drawn with 200 Amps rated copper bus bar 415V, complete all as specified and directed. Including taking down old unsv from exiting place.
S&F in repairs MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10KA complete all as specified and directed.
S&F in repairs MCB SPN, 40 Amps, 240V, B- series with breaking capacity of 10KA complete all as specified and directed.
S&F in repairs MCB SP, 6-40 Amps, 240V, B- series with breaking capacity of 10KA complete all as specified and directed.
Supply and fix Surge protection device Type 1+2 AC single pole and neutral, 1P+N 20kA N Havells Model DHSAARAC50320 or equivalent in Indo Asian/ Legrand/L&T complete all as specified and directed.
Supply and fixing of power console consisting of 5/15 amps multiple Modular switch socket combined - 4 nos fixed in modular box with controlled by one 20 amps MCB SP including grouting in floor/ walls all as directed and as specified. Note:- For Item Sl. No 30,31,55 to 58 Chasis/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concelaed wiring shall be measured and paid separately under relevant item no 53 & 54
Sri Vijalakshmi Constructions
MSA Constructions
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .