Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹47.6 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹55.1 L+₹7.5 L (15.7%)Rejected-Finance | 2 | Rejected-Finance being not lowest | |
| 3 | 3₹59.3 L+₹11.7 L (24.5%)Rejected-Finance | 3 | Rejected-Finance being not lowest | |
| 4 | 4₹60.8 L+₹13.2 L (27.6%)Rejected-Finance | 4 | Rejected-Finance being not lowest | |
| 5 | 5₹61.0 L+₹13.4 L (28.1%)Rejected-Finance | 5 | Rejected-Finance being not lowest |
Tender Value
₹62.6 L
EMD Value
₹1.2 L
Closing Date
9 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF GWALIOR
CWE AF GWALIOR
B AND R MISC REPAIRS TO CERTAIN BLDGS AND STRUCTURES IN TECH AREA AT AF STN GWALIOR
2022_MES_566461_1
85040
Open Tender
Civil Works
Item Rate
180 days
Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) TECH AREA GWALIOR
₹1.2 L
Yes
14 Feb 2023
1 Dec 2022
11 Jan 2023
1 Dec 2022
9 Jan 2023
2 Jan 2023
Amount
M&L for removing old existing rubbish/battered/useless mixture of the binding materials such as cement / Lime and fine aggregate (<4.5mm retained on IS Sieve), loose/unsound weaken mixture of binding materials such as cement / Lime and coarse Aggregate (>4.5mm retained on IS Sieve), fine Aggregate of any description and in any position from existing external/internal surfaces of RC components or any surface having average profundity of 15mm (Approx height 10m from natural ground level) by hand tool that has a long metal blade with a sharp edge at the end, chisel and hammer or using robust pneumatic chisel hand tools and removal beyond MoD land including cutting of all edges, making square shoulders of the aperture, coarsen the smooth surfaces, curettage /removing of all deterioted/decayed loose surface and applying one coat of mixture of two monomer unsaturated liquid hydrocarbon and gaseous hydrocarbon and polymesrized them to get the high polymer dispersion emulsion successfully bonded to cement mortar, to improve adhesion to concrete, better durability, reduced shrinkage and increased flexibility and resistant to emulsification in damp condition modified Ensuring no porosity in new/old surface, temperatures between +5°C and +35°C, Resist to penetration of CO2 4.600 micron characteristic compressive strength (N/sqmm) at 3days strength - 11.5 (N/sqmm ) and at 28 days - 25.30N/sqmm on dilapidated girders or reinforcement encased in concrete complete all as specified and directed by Engr-in-charge. Note- this item shall be undertaken by the authorised rep of manufacturer.
M&L for passivating protective matrix anti-corrosive cementitious protective coatings on corroded visible steel forming a continuous film not less than 1000 micron of Single component for steel reinforcements, preparing the surface to receive the cementitious repair mortars in appropriate proportion (as per manufacturer's instructions) including preparing the surface to match with the existing surface complete all as specified and directed by Engr-in-charge. Note- This item shall be undertaken by the authorised rep of manufacturer.
M&L for preparing the surface to receive the epoxy grout mortar including providing necessary proportions and applying 20mm thick chloride free shear thinning fibre reinforced polymer modified, impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar, alkali resistant synthetic fibres for exceptional resistance against cracking including fixing welded MS wire cloth with corrosion inhibiting additive, primer mucis for providing and applying Passivating protective matrix anticorrosive cementitious protective coatings on exposed corroded reinforcement forming a continuous film not less than 1000 micron of Single component. Repair mortar in the ratio of 0.33:1:4 mixed with cement and fine aggregate(<4.5mm retained on IS Sieve) water based lignosulphonates concrete bonding agent water less than 15% confirms to IS 2645-2003 having specific gravity 1 to 1.2 as per IS 2645-2003 & hydrolysis resistant primer cement modifier, provides excellent bond to concrete, Improves tensile and flexural properties of mortar, Versatile having specific gravity of 1.02 to be applied on surface before application for mixture of cement and fine aggregate complete all as specified and directed by Engineer-in-charge. Note- This item shall be undertaken by the authorised rep of manufacturer.
M&L for resistance to aggressive agents like atmospheric gases, carbon dioxide, chloride ions, sulphates, oxygen and water, cracks, UV rays and rain, efflorescence and lime blooming by using two coats of water based Alicyclic & protect surface to carbon dioxide and adorning coating contains special glass fibres to maintain anti cracking properties for concrete/ Masonary, apply Acrylic emulsion Sealer Coat chemical Make of - Thermax/Torchtar Ltd./Ooms Polymer/Fosroc / Redwop Ltd. chemco system chemicals as approved by GE having High performance Water Based aliphatic protective coating to concrete & masonary surface new or old, after proper surface Preparation, cleaning of dust, dirt, etc. System should comprise of water based acrylic polymer primer coating on prepared surface at 260-280 microns DFT (Density Function Theory) and at 200 microns WFT ( Water Function Theory) using suitable brush or roller, overcoating time @ 30°C shall be 8 hours complete all as specified and directed by Engineer-in- Charge . Note- This item shall be undertaken by the authorised rep of manufacturer
M&L for shear thinning fibre reinforced polymer modified , impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar 15mm thick with alkali resistant synthetic fibres for exceptional resistance cracking complies ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/sqmm, tensile strength @ 7days (ASTM C 307)> 3 N/sqmm, compressive strength of 35MPa at 7 day and 45MPa at 28 days, at the outer or inner RC surface mixed with shear thinning fibre reinforced polymer modified repair mortar in the ratio 1:4 and mixed with hydrolysis resistant primer cement modifier, provides excellent bond to concrete, Improves tensile and flexural properties of mortar, Versatile having specific gravity of 1.02 not less than 2% by weight of cement and as per manufactures instructions for external or internal surface of any brick or stone wall or concrete surface, etc. Top surfaces of the plaster shall be finished even and smooth with using extra cement with chemical component complete all as specified and as directed. Note- This item shall be undertaken by the authorised rep. of manufacturer.
M&L for profundity of 15 mm and 18 mm dia expel dust, etc by vacuum cleaner and blowers, providing and fixing of heavy grade HSN 7307 GIP perforated nipple 15 mm dia, 50 mm long @ 1.0 Mtr C/C in both direction and injection cement slurry blended with and including using integral water proofing compound for cement based concrete and mortar, Chemical Confirms to IS 2645-2003 having specific gravity 1.1-1.2, chloride content Nil as per IS 2645-2003 & using plasticised expanding grout admixture cementitious admixture and hydrolysis resistant primer cement modifier providing excellent bond to concrete, improves tensile and flexural properties of mortar, Versatile and using water based lignosulphonates concrete bonding agent chemical reduces the water demand for required workability and minimise segregation and bleeding, minimize permeability and increase the waterproofing properties of concrete and mortars through nipple and closing ends nipple epoxy putty/silica jelly after injecting the chemicals mixed with cement slurry complete all as specified and directed by engineer in charge. Note:- This item shall be undertaken by the authorized rep of manufacture.
M&L for applying hydrolysis resistant primer cement modifier, providing excellent bond to concrete and water based lignosulphonates concrete bonding agent chemical flexible, two components acrylic modified elastomeric water proofing coating with corrosion protection and elastomeric water proofing protective membrane for positive and negative water pressure on RC inner or outer wall surface etc. complies to ASTM D4541 ASTM C836, DIN 1.048p 5 ASTC D412 having Tensile strength > 0.4 MPa, Elongation > 20%, Cleaning, mixing using slow speed electric drill and application of 2 coats modified elastomeric water proofing coating over a coat of hydrolysis resistant primer cement modifier and water based lignosulphonates concrete bonding agent chemical for internal and external surface of RCC, Top of the Surface shall be furnished even and smoother with extra cement including all finishing the surface of match with the existing surface complete all as specified and directed by Engineer-in-Charge. Note- This item shall be undertaken by the authorised rep of manufacturer.
M&L for plasticized expanding cementitious grout admixture, low permeability and long term durability, high fluidity with low water/cement ratio, mending to cracks and existing deterioted surface of RC roofs slabs, RC and similar work up to any height from normal ground level by structural strengthening with application of dual shrinkage compensating non shrink free flow plasticized expanding cementitious grout admixture complete all as specified and directed by Engr-in-charge. Note- This item shall be undertaken by the authorised rep. of manufacturer. .
M&L for applying 20mm thick metallic aggregates compound which is Corrosion resistant , Non Shrinkable, Rheoplastic, High strength cementitious with 1:4 cement mortar mixed on external or internal surface of RCC inner or outer wall surface etc. having compressive strength as BS- 4551 and strength (ASTM C 109) - 65 MPa@ 28 days, Tensile strength 2.0N/ sqmm @ 28 days, Young's modulus -25 kN/sqmm(ASTM D469). Before pouring apply granolithic E-Resin based solvent free concrete bonding agent/EP in accurate proportion with complete homogenesity having mix density of 1.45 to 1.5 kg/litre, Compressive strength (BS 6319 pt.2)-55 MPa at 7 days, Flextural strength (BS 6319 pt.3)-10 MPa at 7 days, Tensile strength(BS 6319 pt . 7)-15MPa at 7 days, Bond strength(ASTM C 881)-02 N/sqmm at 7 days, pouring by using of suitable arrangement as required using pumping device for uniform flow to ensuring proper bond between the metallic aggregates (Mixed density @27 degree Centigrade), pressure restrain plastic expansion shall be approx. 0.004N/sqmm and existing concrete substrate etc. complete including all tools and tackles as directed by Engr-in-charge. Note- This item shall be undertaken by the authorised rep of manufacturer.
Perforation in RC using twist & rotating mechanical cutting tool for Fastening to concrete for chemical anchoring having a Rapid strength gain, Vibration resistant, Corrosion resistant of reinforcement on existing RC Component with Hilti HIT-HY70 BS 5080 or equivalent as approved by GE, typically attains a compressive strength in excess of 20N/sqmm @ 3 hours and an ultimate compressive strength of 70N/sqmm in 7 days as per BS 6319 Part 2 : 1983, maximum hole depth 75mm, steel bar 12mm dia and drill bit size14mm with polyster resin based anchoring material for H/V/Large annular applications or post installed bars or in accordance with bar thickness complete all as specified and directed by Engr-in-charge. Note- this item shall be undertaken by the authorised rep. of manufacturer.
M&L for applying two coats of single component cementious water proofing membrane for holding the quality of negative hydrostatic pressure on new/old prepared surface, elasticity moduus at 28 days shall be 14000-16000 N/sqmm, adhesion to substrate at 1 day - 0.6N/sqmm and at 28 days - 1.3 N/sqmm , compressive strength at 1 day - 12N/Sqmm and at 28 days -36N/Sqmm, flexural strength at 1 day - 3.6 N/Sqmm and at 28 days - 8.2N/Sqmm, Coating to be applied after proper surface preparation to remove loose dust, dirt etc. cleaning and mixing by using slow speed electric drill complete all as per specification and as directed. Note- this item shall be undertaken by the authorised rep. of manufacturer.
M&L on dilapidated girders or reinforcement encased in concrete for providing and applying alkaline based Anti-oxidizing compound for steel structure conforming to ASTM D 1748-10(2015) after cleaning loose scale or oxidized chips from bars .The material to be applied on the rusted metal using brush. Allow it to react for 16 to 24 hrs, pH Value : Alkaline (9.5 - 10) and afterwards wire brushing the surface. Clean with dry cloth before application of protective coating etc. complete all as specified and directed by Engr-in-charge. Note- this item shall be undertaken by the authorised rep of manufacturer
Taking down the old serviceable and rusted supporting structure panel from any Height of OHT (Over Head Tank) of any type, in any position and fixing suitably designed new supporting structure on the roof of Over Head Tank and fixing new staircase made of mild steel supports including thickness 4mm angle and width 1.5 inch MS pipe 25mm dia nuts and bolts etc. completed all as specified and directed by the Engineer-in-Charge
M&L for preparing new surface of steel over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge.
M&L for preparing new surface of steel, n.exc 10cm in width or girth applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge.
M&L for providing adequate moisture, temperature and time to allow the surface to achieve the desired properties for its intended use by using viscosity alkali reactive wax based compound in which liquid substance that is added as a surface coating on repaired concrete surface. These compounds shall be used to reduce the loss of water or heat in order to create ideal conditions that are favourable to the increase in the strength of concrete complies with the internationally recognised ASTM C309-90 standards typically within the range of 200 to 285 ml/sqm, SG - 1.02 including all tools and tackles. complete all as specified and directed by Engr-in-charge. Note- This item shall be undertaken by the authorised rep. of manufacturer.
M&L for MS TMT bars 12 mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9 mm dia complete all as specified and directed by Engineer in Charge.
M&L for Shear thinning agents in RC/ walls/ ceiling/ columns/ beams/floor/bricks cracks after opening up in “V” groove manner covering the area of 300mm from central line of crack with the depth of 8 mm complete with three components compound graded filler, E-Resins and Shear thinning agents with adjustable consistency by varying the filler component epoxy resin based complete all as specified and directed by Engineer in Charge. Note-This item shall be undertaken by the authorized rep. of manufacturer.
M&L for complete removal of existing treatment and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and applying two coats of cement base paint on wall over a coat of primer complete all as specified and directed by Engr-in-charge.
Notes:- (a) The work shall be executed by authorised representative/ applicator of manufacturer of water prrofing compounds. Contractor shall submit certificate/MoU to GE before commencement of work. (b) Material shall be tested (minimum three tests specimen from the single lot) before approval and after receipt of each consignment before incorporation in the work, from any Govt recognised lab, approved by GE at cost of contractor. (c) The material brought during the execution shall be checked with sample of material tested and approved by the GE for quality assurance before incorporated in the work. The Chemical shall be one of the make as given in BOQ and list of Make as approved by GE. (d) The material as incorporated in the work shall be procured directly from manufacturer or their authorized representative as mentioned in BOQ. An undertaking for being a authorized representative of the manufacturer along with supporting documents shall be submitted by the supplier. Material for incorporation in work shall be allowed only after production of purchase voucher/invoice from the manufacturer/documents pertaining to authorised dealership in original and test certificate from the manufacturer. The brand shall be got approved in writing from the GE. Application, Preparation of mix and method of mixing shall be as per manufacturer's instructions. Contractor will submit the 50% quantity of Chemical in the sealed container in the office of Engr-in-Charge before starting the work alongwith original purchase voucher of the material. Engr-in-Charge will keep the empty container of full quantity of the chemical in his custody till one year from the date of completion of work. (e) The Contractor shall give Guarantee for structural repair of tank for a period of 10 (Ten) years from the certified date of completion. Similarly the Contractor shall take warranty of structural repair for next 10 years of the work immediately after executions/ completion of work from the authorised Applicator. (f) Adoption of necessary safety arrangement like belts, ropes, helmets, netting etc which are required for safety of working including fixing of steel pipe scaffolding (Telescoping or otherwise) including steel sheet lining or steel plate stiffener with steel angle and cradles including hoisting and lowering as required with and including all kind of fixing arrangement suitable for over head tank of any shape or type for 50000 gallons to 100000 gallons capacity fixed all around OHT and below bottom dome to carry out necessary repair/ replacement work at any height shall be mandatory deemed to be inclusive in quoted rates and nothing extra will be entertained on this account. (f) All demolished material obtained from dismantling/demolition items shall be deposited at place shown by Engr-in-charge properly spread and levelled and site to be cleaned to the entire satisfaction of Engr-in-charge otherwise penal recovery to a sum of Rs. 10000.00 be deducted from dues without any prior intimation.
Neeraj construction company
m/s vikash Engineers
M/s Manish Contractor
M/s Sagar Construction
M/s Ratan Lal Jain and Co.
M/s Raghav Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .