GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIRS/ REPLACEMENT TO FLAME PROOF WIRING AND ASSOCIATED WORKS OF BPs HANGERS AREA AND STORES AT AIR FORCE STAION JAISALMER
2026_MES_796521_1
8501/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹40,000
Yes
30 Oct 2026
30 Oct 2026
20 Nov 2026
30 Oct 2026
18 Nov 2026
12 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully aluminium point wiring on wooden battens/through conduit (light fan, socket or power) complete with fittings such as switches, wooden batten, ceiling roses, pendants, regulators, box type tube light fittings, removing the materials from site except fittings etc which shall be reused in the work and making good the disturbed surfaces of walls/ceiling/ floors etc complete all as specified and as directed by Engineer-in-Charge | 342 | Per Point | - | - |
| 2 | M&L for flame proof point wiring with two single core FRLS-H PVC insulated & PVC unsheathed multi stranded copper conductor cable of size 1.5 Sqmm 1100 volts grade in and including ERW steel conduit of size 20 mm or Higher dia with all accessories and one single core PVC insulated & PVC sheathed multistranded FRLS-H copper cable of size 1.5 Sqmm 1100 Volts grade as earth continuity conductor connected to common earth dolly, switch board complete incuding cutting chesses on wall/ floour/ ceiling etc. & making good the disturbed surface with 1:4 cement morter all as specified for one light / fan point controlled by one 5 Amps flameprrof switch one way complete. | 20 | Per Point | - | - |
| 3 | All as per Sr item No. 2.00 herein before but with 4 sqmm for phase &neutral and 4 sqmm for earth wire for socket out let 15 Amps on independent board. | 20 | Per point | - | - |
| 4 | Supply and fixing in repair LED Light Fitting 1x20 Watt flame proof ,CMRI certified recommended for gas/vapour group of IIA &II B ,zone 1 and 2 and IP 65 Protection with die cast alluminium housing with heat resistant toughned glass with LED tube light, fixtures, driver holders ,connectors etc complete with all accesories prewired and including connecting with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. | 20 | Each | - | - |
| 5 | Supply and Fixing in repair Flameproof cum Waterproof Round type LED Flood light fitting of 80W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed | 10 | Each | - | - |
| 6 | M&L in repair switch flame proof rotory type with termination box in LM 6, 16 A, single phase 250 volts complete all as specified and directed by Engr-in-Charge.. | 20 | Each | - | - |
| 7 | M&L in repair switch flame proof switch socket & plug combained in LM 6 cable termination box in LM6, 16 A, 250 V, 2P+ earth complete all as specified and directed by Engr-in-Charge. | 20 | Each | - | - |
| 8 | S & F in repair Flame proof weather proof DB(Distribution Board) SPN 4 Way having Incoming MCB of 16A/25A 2Pole and outgoing total 02 MCBs CBs as -01 Nos.6 Amps Single Pole MCB, and 01 nos 10Amp MCB Sp all including interconnections and Bus Bar of Suitable Size with sufficient Entries for Mounting cable Gland for incomer and outgoing cables. | 1 | Each | - | - |
| 9 | S & F in repair Flame proof weather proof DB(Distribution Board) SPN 6 Way having Incoming MCB of 32A 2Pole and outgoing total 04 MCBs CBs as -6 to 32 Amps Single Pole MCB Sp all including interconnections and Bus Bar of Suitable Size with sufficient Entries for Mounting cable Gland for incomer and outgoing cables. | 1 | Each | - | - |
| 10 | S & F in repair Flame proof weather proof DB(Distribution Board) SPN 8 Way having Incoming MCB of 32A 2Pole and outgoing total 06 MCBs CBs as -2 Nos.6 Amps Single Pole MCB, 2 Nos 10A Amps MCB Sp and 02 nos 16Amp MCB Sp all including interconnections and Bus Bar of Suitable Size with sufficient Entries for Mounting cable Gland for incomer and outgoing cables. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_893400.xls
BOQ • 0.34 MB
8501Tenderdocument.pdf
Tender Documents • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .