Executive Engineer (E )BM-II
BM-II (E ) Division, Gyan Mandir Office, Tees January Lane, New Delhi - 110011
Supply, Replacement, Testing, and Commissioning of Ductable type Air Conditioning Plant at Palika Health Complex, Dharam Marg under BM-II(E) division, New Delhi
2026_NDMC_297101_1
43/EE (BM-II) E/26-27
Open Tender
Electrical Works
Percentage
30 days
Palika Health Complex, Dharam Marg under BM-II(E)
As per NIT
2 documents required · 2 mandatory
₹0
₹75,600
27 Aug 2026
17 Aug 2026
27 Aug 2026
17 Aug 2026
27 Aug 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of existing 03 nos 7.5 TR and 01 nos 5.5 TR outdoor ductable unit from periphery with the help of heavy labour by dismantling the copper connection from the existing AHU, bring it down & Supply Installation testing and Commissioning of 8.5 TR Air-Cooled floor mounted ductable type DX units based on eco-friendly refrigerant R410A complete with scroll compressor icroprocessor based control panel, remote and all associated ancillaries including lifting, shifting of unit from ground floor to terrace etc along with pressure testing vacuuming etc complete as per site requirement. Make: Hitachi/Mitsubishi/O-General Gurantee/Warranty - 02 Years | 4 | Each | 4,30,000 | ₹17,20,000 |
| 2 | Topping of R-410A gas for 4 Nos 8.5 TR outdoor units as per site requirements | 40 | Kg. | 1,400 | ₹56,000 |
| 3 | Copper Refrigerant Piping with Insulation Supply ,Installation, Testing & Commissioning of high pressure copper refrigerant piping suitable for 11 TR ductable unit of following size as required and duly insulated with 13mm thick closed cell elastomeric nitrile rubber insulation in tubing form including cutting of floor/wall as in where required and Complete as per site requirement
(i) 25.4 mm dia/19 mm thick insulation | 110 | Mtr. | 3,200 | ₹3,52,000 |
| 3.01 | (ii) 12.7 mm dia/19 mm thick insulation | 110 | Mtr. | 2,400 | ₹2,64,000 |
| 4 | SITC of Condensate Drain Piping Ø 25 mm dia | 90 | Each | 249 | ₹22,410 |
| 5 | Dismantling the existing worn out/rusted ducts and existing XLPE 13mm insulation at various places with the help of cutting machine/grinder, removing the same from site and supplying, fabrication , testing commissioning of 0.8mm thick GI sheet duct sheet (metal rectangular ducting) complete with neoprene rubber gaskets. elbows,vanes, hangers. supports etc. complete at site including pasting of high grade 13mm XLPE matsheet inside on the existing new duct with the help of good quality fevicol/sticking material as per satisfaction of site engineer | 80 | Sq. Mtr. | 3,100 | ₹2,48,000 |
| 6 | Dismantling of existing XLPE 13mm insulation on various ducts at Ground Floor Palika Health Complex, Dharam MArg with with the help of cutting machine /grinder at various height levels with the help of long ladders , cleaning the duct by scrubbing brushes, making it smooth and pasting of high grade 13mm XLPE mat sheet on the existing new duct with the help of good quality fevicol/sticking material to protect it complete job as per satisfaction of site engineer. | 120 | Sq. Mtr. | 700 | ₹84,000 |
| 7 | Providing, installing, testing, and commissioning of a factory-fabricated Air Handling Unit (AHU) of 3600 CFMcapacity, suitable for use in a centralized air conditioning system as with mentioned in item no 1 in this schedule of
work. The AHU shall be of double-skin construction with PUF insulation (minimum 25 mm thick panels) having thermal conductivity not exceeding 0.022 W/mK. The outer casing shall be made of 0.6 mm pre-coated galvanized steel and the inner casing of 0.5 mm plain galvanized steel. The unit shall be complete with a highefficiency cooling coil made of copper tubes and aluminium fins, suitable for chilled water or refrigerant operation, with an SS-304 drain pan duly sloped for proper drainage. It shall include a DIDW (Double Inlet Double Width) centrifugal fan, statically and dynamically balanced, either belt-driven or direct driven, mounted on vibration isolators with flexible duct connections. The AHU shall be equipped with a high-efficiency motor (IE2/IE3 grade), suitable for 415V, 3-phase, 50 Hz power supply. A filter section with EU-4/G4 grade washable synthetic pre-filters shall be provided along with filter mounting frames. The unit shall also include gasketed hinged access doors, a heavy-duty galvanized steel base frame for floor-mounted installation, and be capable of delivering an air volume of 3600 CFM (±5%) at an external static pressure as per site requirement. The AHU shall be supplied with all necessary accessories including vibration isolators, drain piping, and control panel interface. The complete unit shall be of make as suitable with the item mentioned in item no 01, factory-tested, and installed in accordance with standard engineering practices, and commissioned to the full satisfaction of the Engineer-in- Charge. Make: Alfawave, Hitachi | 4 | Each | 1,47,000 | ₹5,88,000 |
| 8 | Supplying and laying of 1.1 kV grade copper conductor armoured cable of the following size for communication between indoor & outdoor units on surface/ cable try/ existing pipe/along with the copper refrigerant pipes, complete, etc., as required (Make: Polycab, Havells, Finolex) 6c x 1.5 sqmm | 100 | Mtr. | 258 | ₹25,800 |
| 9 | Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. | 45 | Sq. Mtr. | 5,000 | ₹2,25,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.18 MB
BOQ_395734.xls
BOQ • 0.30 MB
datechange.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].