Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC BANDARAILAH MALDA | MALDA | MALDA | WEST BENGAL | L1 | Accepted-AOC Offered Lowest Rate | |
| 2 | L2₹4.0 L+₹5,377.40 (1.37%)Rejected-Finance BIBIGRAM SOUTH NEAR JALALIA GIRLS HIGH SCHOOL MALDA ENGLISHBAZAR 732101 | ENGLISHBAZAR | MALDA | WEST BENGAL | 732101 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹4.0 L+₹9,175.67 (2.34%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L3 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹8,100
Closing Date
23 May 2025, 4:30 pmClosed
Assistant Engineer-II, Malda Mechanical Division
Doulatpur PHE-Complex, Maliha, Malda,732102
supply, delivery and installation of different spare parts at VCB panel, Oil filtration at Transformer, Rectification of Backwash feeder panel other allied works at Sub-station building and High Lift Pump house of Dariapur Water Treatment Plant with
2025_PHED_840445_3
WBPHED/AE-II/MLMD/NIeT_02 of 2025-2026
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
Doulatpur PHE-Complex, Maliha, Malda, 732102
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,100
Yes
1 Aug 2025
13 May 2025
26 May 2025
13 May 2025
23 May 2025
13 May 2025
Amount
SINGLE PANEL VCB :
Supply and delivery of Tripping Circuit Fuse (6 amp. glass fuse)
Supply and delivery of Various hardware materials like High Tension Nut Bolt, Washer etc.
Supply and delivery of Tripping Coil for ESPL make 11 KV VCB Coil Voltage: 110 V DC
Supply and delivery of Closing Coil for ESPL make 11 KV VCB Coil Voltage: 110 V DC
Supply and delivery of Indicating lamp (LED) supply Green – 1 No., Blue – 1 No.
Charges for attending on Fault, Power Circuit checking, Control Circuit checking, Fault Identification, Panel checking, Trip circuit fuse replacement, Tripping coil replacement, Closing coil replacement, hardware materials fitting/fixing etc.
TRANSFORMER-2 (750 KVA, 11 / 0.433 KV)
Charges for All kinds of Gaskets& oil seal supply for HT & LT bushings, top cover, inspection cover, valve etc. of 750 KVA, 11 KV /0.433 KV Transformer
Charges for gasket changes for 750 KVA, 11 / 0.433 KV Transformer by disconnecting of all HT & LT terminals, draining transformer oil, opening of top cover, arresting of any oil leakage by changing of gasket & oil seal respectively various gasket portion like top cover, inspection cover, tap switch, conservator tank, radiators, buchholz, drain valve (As where required) & HT-LT bushing portion
Charges for Oil Filtration of transformer.
Supply and delivery and replacement of Silica Gel.
Charges for Di-Electric Strength Test (BDV Test)
Supply delivery of New Oil Transformer Oil
TRANSFORMER-3 (750 KVA, 11 / 0.433 KV)
Charges for Oil Filtration of transformer.
Supply and delivery and replacement of Silica Gel.
Charges for Di-Electric Strength Test (BDV Test)
Supply delivery of New Oil Transformer Oil
Supply delivery of 12 V Battery Make: Exide, Type: EP 42-12 Capacity: 42 Ah
Charges for Replacement of 16 Nos. 12 V battery
Laying & socketing of Cable at High Lift pump house.
Supply delivery of 240 sq. mm heavy duty Alu. Socket.
Charges for Attending on Fault, Fault Identification & rectification, Laying of 44 Mtrs.1.1 KV grade 4C, 300 sq. mm., XLPE insulated Al, Ar, Cable, 24 nos LT End Termination with Cable socketing 240/300 sq. mm. cable and DC fault rectification at HT site.
FAULT IDENTIFICATION & RECTIFICATION WORK OF BACKWASH FEEDER OF HIGH LIFT PUMP HOUSE AT DARIAPUR WTP
18.5 KW BACK WASH PUMP FEEDER- 1
Charges for Emergency basis attending on Fault, thoroughly Power & Control circuit checking, Fault Identification, Fault rectification by replacing defective MCCB from pump no-2 to pump no-1
18.5 KW BACK WASH PUMP FEEDER- 2
Charges for Emergency basis attending on Fault, thoroughly Power & Control circuit checking, Fault Identification
18.5 KW BACK WASH PUMP FEEDER- 3
Supply delivery of Power Contactor CL 45 (make- GE, 220 V)
Supply delivery of Add ON Block.
Charges for Emergency basis attending on Fault, thoroughly Power & Control circuit checking, Fault Identification, Fault rectification by Replacement of 2 nos power contactor, 5 nos NC Add-ON Block & 2 nos NO Add-ON Block.
Add GST @ 18%
Add Cess @ 1%
HANNAN BUILDERS PRIVATE LIMITED (BID ID -6410371)
DEY ENTERPRISE (BID ID -6408124)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .