Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.9 LAccepted-AOC GUIJAN GAON WARD NO 3 C O RAJKHOWA HOUSE P O RANGAGORA DIST TINSUKIA ASSAM PIN 786147 | TINSUKIA | ASSAM | 786147 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹45.6 L+₹54,115 (1.20%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹46.7 L+₹1.7 L (3.80%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹47.3 L+₹2.3 L (5.05%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹47.6 L+₹2.6 L (5.67%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
22 May 2024, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
REPAIR MAINT OF POINT WIRING FIXTURES, MCB DBs TO VARIOUS OFFRS MD ACCN, CERTAIN UNITS, REPAIR REPLACEMENT OF SECURITY LIGHT TIMMER, CONNECTED ALLIED SERVICES, ROOF SHEET, FALSE CEILING, COMPUND WALL, PERIODICAL SERVICE FOR MES INSTLN AT OUTPOCKET
2024_MES_651944_1
C/8665/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹87,000
Yes
23 Jul 2024
2 May 2024
29 May 2024
2 May 2024
22 May 2024
16 May 2024
Amount
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, including unserviceable fitting such as switches, ceiling roses, pendants, regulators, sockets, etc and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable sub-main wiring any type with rigid steel conduits/PVC Conduits/PVC casing-caping complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box (sunken type) switch board fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/ceiling fan/Exhaust fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No 03 above but one 5 Amps, 3/5 pin socket outlet on the same board with other switches complete all as specified and directed.
All as per item No 03 above but for one 3 pin Switch socket combination, 5 Amps on Independent board complete all as specified and directed.
All as per item No. 03 here-in-before but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 15 Amps switch socket combination on Independent board complete all as specified and directed.
M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing PVC/modular metal box of suitable size with 3mm thick hylam sheet cover for fixing of switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 07 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No 07 above but for one 3 pin socket outlet, 5 Amps on the same board with other switches
All as per item No 07 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board. One 3 pin socket outlet, 5 Amps, independent board.
S & F switch piano, 5 Amp single pole, flush type one way 230 volts complete all as specified and as directed.
S & F Bell push, flush type, 5 Amps 230 Volts, complete all as specified and directed.
S & F Socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5A/16A, 5 in 1, 240 volts, flush type complete all as specified and directed.
S & F call bell / Buzzer, Ding Dong AC. 230 volts, single pole all as specified and directed.
S & F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and directed.
S & F lamp holder, insulated body with back plate suitable for batten fittings all as specified and directed.
S & F LED Lamp 9 Watt complete all as specified and directed by engineer in charge.
S&F Stepped type electronic fan regulator flush type 230 volt 5 speed control and connecting up and fix position , complete all as specified and as directed.
S & F 18/20 W surface and wall mounted LED batten with polycarbonate housing and integrated driver all as specified and directed.
S&F 9 W surface and wall mounted LED Battern with polycarbonate housing and intigrated complete all as specified and directed by engineer in charge.
S&F 10W,LED, Energy saving new generation bulk head luminaire with opal diffuser including lamp including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F 15 watt Recess, mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver included cutting-opening of celing any type & fixing arrangement for fitting complete all as specified and directed by Engineer-in charge.
S&F 42 watt , Recess mounted deep drawn PLANO 2X2 feet CRCA housing with higher power LED Seamless front frame with flat white hight transmission acrylic cover all as specified and directed by Engr in charge.
S&F in repairs LED wall bracket light asthetically designed with B22d & E27 lamp holder made up of polycarbonate, suitable for 9/10 including suitable LED bulb complete with all accessories including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to light fittings and taking down old light fittings of any type complete all as specified and dierected.
S&F 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having BOTTOM OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 complete all as specified and dierected.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
S & F Factory made board distribution (DB) single door in sheet steel enclosure without bus bar, SPN, 2 way, 240 Volts suitable for housing MCBs complete all as specified and directed.
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with 200 amps rated common bus bar at incomming end, SPN, 4 way, 240 Volts, suitable for housing MCBs complete all as specified and directed.
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 8 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed.
S & F Factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 12 way, 240 Volts , 200 amps suitable for housing MCBs complete all as specified and directed.
S & F factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, TPN, 4 way, 415 Volt IP-43, IK-09, suitable for fixing MCBs complete all as specified and directed.
S & F in repair MCB, 'C' Series, SPN, 240 Volts, 6 to 32 Amps, 10KA capacity complete all as specified and directed.
S & F in repair MCB, 'C' Series, SPN, 240 Volts, 40- 63 Amps, 10KA capacity complete all as specified and directed.
S & F in repair MCB, 'C' Series, SP, 240 Volts, 5 to 32 Amps, 10KA capacity complete all as specified and directed.
S & F in repair MCB, Four Pole, 415 Volts, 63 Amps, "C" series, 10 KA breaking capacity complete all as specified and directed.
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep, including taking down old unserviceable one complete all as specified and directed.
All as per item No 38 above but size 250 mm x 200 mm x 50 mm deep complete all as specified and directed.
All as per item No 38 above but size 350 mm x 300 mm x 50 mm deep complete all as specified and directed.
All as per item No 38 above but size 175 mm x 100 mm x 50 mm deep complete all as specified and directed.
All as per item No 38 above but size 100 mm x 100 mm x 50 mm deep complete all as specified and directed.
S & F in repair Switch piano, flush type, 5 Amps, single pole, one way, 240 Volts including taking down old unserviceable one complete all as specified and directed.
S & F in repair Ceiling rose, 3 Terminal, PVC/polycarbonate, isolated body including taking down old unserviceable one complete all as specified and directed.
S & F in repair lamp holder, insulated body with back plate suitable for batten fittings complete all as specified and directed.
S & F in repair Bell push, flush type, 5 Amps 230 Volts, complete all as specified and directed.
S & F in repair Call Bell Ding-Dong type, AC, 230 volts, single pole complete all as specified and directed.
S & F in repair Socket outlet, 3/5 pin , 5 Amps, flush type complete all as specified and directed.
S & F in repair Switch socket combination 2 in 1, 5 pin, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repair Switch socket combination 2 in 1, 6 pin, 6/16 Amps, flush type, 240 volts complete all as specified and directed.
S & F in repair Stepped type (five steps), electronic fan regulator, 220 volts, flush type complete all as specified and directed.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one/ dismantling complete all as specified and as directed.
S & F in repair 18/20 W surface and wall mounted LED batten with polycarbonate housing and integrated driver all as specified and directed.
S&F in repair 9 W surface and wall mounted LED Battern with polycarbonate housing and intigrated driver complete all as specified by Engr-in- Charge.
S&F in repair recess mounted deep drawn PLANO size (2 ft x 2 ft) CRCA housing with higher power 36 Watt LED Seamless front frame with flat white hight transmission acrylic cover complete all as specified and as directed.
S&F in repair 15 watt Recess, mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver included cutting-opening of celing any type & fixing arrangement for fitting complete all as specified and directed by Engineer-in charge.
S&F in repair 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having BOTTOM OPENING separate driver compartment with IP65 protection and impact resistance of IK07 including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed.
S & F in repair LED wall bracket light aesthetically designed with B22d & E27 lamp holder made up of Polycarbonate suitable for 9/10 W including suitable LED Bulb complete with all accessories internally pre-wired and including connecting up with twin core twisted flexiblecopper conductor cable with suitable size.
M & L for Sub main wiring with two runs of 6 sqmm (Nominal area) single core cable FR PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through providing (new) casing-caping of suitable size, fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, FR PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete all as specified and as directed by Engineer-in-charge. (Note : (a) PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.)
All as per item No 59 here-in-before but size of copper conductor 2 run of 4 sqmm and 1 run of 4 Sqmm for earth.
All as per item No 59 here-in-before but size of copper conductor 2 run of 10 sqmm and 1 run of 10 Sqmm for earth.
EXTERNAL ELECTRIFICATION: Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Material & Labour for common burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of suitable size available in market to cover LT underground cables, laid dry and flat abutting each other with gaps not exceeding 10mm including taking down old unserviceable bricks complete all as specified and directed.
Taking out/down old/unserviceable under ground LT cables of any size and connections including pipes etc from trenches/walls/poles of any cross sectional area and keeping serviceable materials in safe custody for reuse and unserviceable materials removing from site complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items of this schedule. (2) Excvation and earth work shall be measured and paid seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 10 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 4 core, nominal cross sectional area of main conductor 16 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI Pipe complete all as specified and as directed.
S&F in repairs 25 mm dia, rigid non metalic, PVC Conduits complete with all accessories suitable for wiring to street lights complete all as specified and as directed.
S&F for service cable, 1100 volts grade heavy duty cable with PVC insulated, stranded aluminium conductor served with an inner seathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core stranded conductor of 4 Sqmm nominal cross sectional area complete all as specified and as directed.
Taking down LED/CFL/sodium vapour/metal halide/MV lamp street light/flood light/ any other light fitting of any make and size refixing the same in position after replacement of unserviceable/defective parts like fittings , lamps , LED driver etc as required to make the fittings in smooth serviceable condition and testing complete and as directed. Note : (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of worn out cables as per existing size and type of the fitting shall be deemed to be included in the unit quoted rate of this item. (iii) Necessary climbing arrangements like scaffolding for repairing/ removing/ refixing the fittings should be included in the quoted rate.
All as per item No. 73 here-in-above but for aviation lights complete all as specified and as directed.
S&F in repairs lamp holder assembly as per existing garden light fittingwith necessary modifying the electrical connections complete all as specified and as directed.
S&F in repair for new LED street light fitting of capacity 120W, Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 2.5 Sqmm as required in existing location complete all as specified and as directed.
S&F in repair new LED street light fitting of capacity 90W, Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 2.5 Sqmm as required in existing location complete all as specified and as directed.
S&F in repair for new LED street light fitting of capacity 70W, Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 1.5 Sqmm as required in existing location complete all as specified and as directed. .
S&F in repair new LED street light fitting of capacity 60W, Street lights are aerodynamically designed for all weather conditions with excellent thermal management, made up of pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. 10 KV SPD included,Efficacy ≥110/120 LPW, including with necessary brackets /pipes/clamps & nuts& bolts for holding the street light fitting and three core copper cable of 1.5 Sqmm as required in existing location complete all as specified and as directed.
S&F in repairs integral compact wide beam high performance 200 W LED flood light luminaire with PLUTO NEO LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy ≥ 110/120LPW 10KV SPD including connecting up with 2.5 Sqmm multistranded copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and as directed.
S&F in repairs integral compact wide beam high performance 100 W LED flood light luminaire with ROVER PLUS LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy >110/120 LPW 10KV SPD to be ordered separately with built in control gear including connecting up with 2.5 Sqmm multistranded copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed.
S&F in repairs integral compact wide beam high performance 70 W LED flood light luminaire with ROVER PLUS LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy >110/120 LPW 10KV SPD to be ordered separately with built in control gear including connecting up with 2.5 Sqmm multistranded copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed.
S&F in repairs integral compact wide beam high performance 50 W LED flood light luminaire with ROVER LED floodlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. System efficacy >110/120 LPW, 10KV SPD version to be ordered separately with built in control gear including connecting up with 2.5 Sqmm multistranded Aluminium/Copper conductor cables of suitable length with fixed to pole/wall, etc and testing complete all as specified and directed.
S&F in repairs modular junction box made of SMC/FRP of size 250x200x105mm with provision of MCB SP, and connector terminal 4 pole indicating RYB Phase Colour and Neutral colour complete fixed to street light pole with suitable size of mild steel/ flat iron clamps, nuts and bolts complete all as specified and as directed.
S&F in repairs, LED post top lantern of 40 Watt MAPLE Decorative Post top for 360° indirect light with IP 65 protection. Resistant to impact and corrosion. Glare-free and better uniformity including providing and connection with 1.5Sqmm copper conductor, multistranded copper conductor cable of required length complete all as specified and as directed.
S&F in repairs 10W LED Bollard MAYA I Pressure die cast powder coated housing with PC diffuser. Efficient high output LED with IP65 protection complete all as specified and directed .
S&F in repairs street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed.
S&F for LED post top 20watts cap HERITAGE Rated LED Post Top ideal to light up parks, gardens and heritage sitewith rated voltage 240 Volts including high voltage and short circuit protection IP 65, with necessary suitable fixing accessories/arrangements complete all as specified and as directed.
S&F for time switches digital type 415 Volt Three phase of 65 Amp rating with contactor fitted inside and MCB TPN 63 A, max load of 6 KW within steel enclosure complete including connecting items complete all as specified and as directed.
Supply and fix Integral LED aviation lights comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed.
S&F for time switches digital type 240v/ single phase of 32 Amp rating with contactor fitted inside and MCB SPN 40 A, max load of 12 KW within steel enclosure complete including connecting items complete all as specified and as directed.
M&L plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed for the poles and stay.
M&L in repairs for cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pole coping including necessary form work for fair finish surfaces duly breaking the old damaged and placing a new flush box for termination inside the base complete complete all as specified and as directed.
Supply and fix in repair LED lamp 10 Watt B22 Base surge protection 2.5K,CCT 6500K complete all as specified and as directed.
Supply only PVC insulation tape of pack of 30 rolls multi colour and black of standard size and thickness 2 to 3mm complete all as specified and as directed.
S&F for LED drivers suitable for any make and type of LED street light fittings of capacity 20 to 45 watt including taking down old unserviceable driver complete all as specified and as directed.
S&F for LED drivers suitable for any make and type of LED street light fittings of capacity 60 to 120 watt including taking down old unserviceable driver complete all as specified and as directed.
S&F for LED drivers suitable for any make and type of LED Flood light fittings of capacity 50 to 150 watt including taking down old unserviceable driver complete all as specified and as directed.
S&F for LED drivers suitable for any make and type of LED Flood light fittings of capacity 200 watt including taking down old unserviceable driver complete all as specified and as directed.
M&L for scrapping the existing surfaces of the street light poles of height 7.5 metres (painting length) with emery paper, removing the dust and rust properly and applying 2 coats of aluminum paint over complete pole and stickering the pole with glow sign round the electrical pole at three places of 10cm width and numbering with paint not less than 4 letters with glow sign material at the bottom of pole and nomenclature shall be given by Engineer-in-Charge complete all as specified and as directed.
M&L for drawing a circle and writing the number in side the circle on Electric pole not less than 4 letters and nomenclature and colour of the sticker to be stickered on pole shall be given by Engineer-in-Charge complete all as specified and as directed.
S&F in repairs 50 mm bore, steel tubes, galvanised, light grade with all fittings and fixtures complete fixed to walls, ceilings, pole using suitable clamp/holder bat complete all as specified and as directed.
Taking down the service connections of the light fittings from connector/ ceiling roses/ overhead bare conductor etc of the street/ security lights , from height of approx 7mtr above ground by any means on PCC/Metal poles with all safety measures to remove the carbon deposits/ disconnected due to wind/wear & tear complete and connecting /fixing back the connections /fittings at existing place complete all as specified and as directed
Dismantling of unserviceable broken LT pole steel/RCC any size including demolition of foundation as required and making good distrub surface and keeping serviceable pole for re-use in any location complete all as specified and as directed. Note : Earth work wherever involved shall be measured and paid separately.
M & L for steel tubular swaged pole 410 SP-22 (9 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
Taking down carefully 15 meter long mast light, removing all the serviceable fittings (6/9 Nos) of 250/400 Watt for refixing after replacement of worn and unserviceable rope, chain, gear, jubli clamp etc after servicing re-installation of the complete High Mast, complete all as specified and as directed. Note: Spare parts shall be measured and paid separately.
B&R- PART Demolition of brickwork or stone/ boulder masonry, built in Cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar in (1:4) complete all as specified and as directed
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for plain cement concrete (1:3:6), type C2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position, unframed work complete all as specified and as directed.
Dismantling timber works in fillets, rail, post, rafter, purlins etc under 40 Sq.cm in section (unframed work), in any position complete all as specified and as directed.
Dismantling of structural steel work including doors, window, gates but excluding framed truss etc complete all as specified and as directed.
M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde (E-165) complete all as specified and as directed.
M&L for second class hardwood, scantlings, wrought, timber framed and fixed complete all as specified and as directed.
S&F for mild steel flat iron as in hold fast 25x6 mm confirming to Fe290 (Gde E-165) complete all as specified and directed
Dismantling posts or struts (wood, steel or RCC) any section embedded in concrete, brick work, masonry etc, including taking out embedded portion concrete, brick work, masonry work, etc and making good disturbed ground complete all as specified and as directed.
Dismantling fencing wiremesh, any type, any size complete all as specified and as directed.
S&F for mild steel angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
Supply only chain link mild steel galvanised fencing any size or type 4 mm dia galvanized wire (100x100) mm mesh made upto matress lapped wire and laid on position / fixed on poles complete all as specified and as directed.
Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed.
S&F for galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed.
M&L for mild steel round bars of Fe 290 (Gde -E-165) 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F for mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5cm long complete all as specified and as directed.
Dismantling of asbestos cement (corrugated or semi corrugated) sheets in roof coverings including ridges complete all as specified and as directed.
S&F for 6 mm thick asbestos cement sheet, corrugated, or semi corrugated sheets as in roofs, etc. and fixed with 'L' type or 'J'-type or cranked hook bolts, complete all as specified and as directed.
S&F for 6 mm thick asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheet, fixed with 'L' type or 'J' type hook or cranked hook bolt with washer complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
M&L for anodised aluminium snap grid size 605 X 605 mm frame work for false ceiling complete all as specified and as directed.
S&F for hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
M&L for 4 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws including two coats of distemper oil emulsion on surface of ceiling/boards etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall with cement mortar (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick other than fair faces of brick work or concrete surfaces of walls in cement mortar (1:4) with WPC @ 200 ml per 50 kg of cement or all as per manufacturing instruction complete all as specified and directed.
M&L for rendering 5 mm thick on ceiling in cement mortar (1:3) finished even & smooth without using extra cement complete all as specified and directed
M&L for applying two coats of distemper oil emulsion after preparation of new plastered surfaces of wall over a coat of clearcholle primar complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of cement base paint over a coat of alkali resistant priming paint including complete all as specified and directed
M&L for preparation of new plastered surface of walls etc applying two coat of oil bound distemper over a coat of clearcolle primer with 2mm thick wall care putty on wall complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new or untreated surfaces of wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over pink primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of wooden surface of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparing of old steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enameled paint complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, not exceeding 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls by washing, rubbing down and scraping of existing distempering/painted surfaces etc and applying one coat of distemper oil emulsion complete all as specified and as directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and greases spots and applying one coat of cement base paint (white or tinted) complete all as specified and as directed
M&L for PCC (1:2:4) type B1 (using 20 mm graded aggregate) as in brick or concrete wall complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick plastering in cement mortar 1:4 finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm Note :- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
Shree Trilok Electric Corporation
Bimal Trading Company
MAZUMDAR ENTERPRISE
STANDARD ELECTRIC WINDERS
FREEZCON
Construction House
M/S CHANDAN ENTERPRISE
M/S KAUSHIK ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .