Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC 204 BLOCK 1 DLF CORPORATE PARK MG ROAD HARYANA GURGAON HARYANA 122002 | GURUGRAM | HARYANA | 122002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.0 L+₹10.2 L (41.2%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical No Document Submitted |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
25 Feb 2022, 1:00 pmClosed
Director Research
Directorate of Research, RCA Campus, outside Surajpole, Udaipur
CN Analyzer
2022_MPUAT_259019_1
DOR/e-NIT/2021-22/42
Open Tender
Laboratory and scientific equipment
Item Rate
30 days
DFRS, Arjia
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Director Research, MPUAT, Udaipur
₹52,000
Yes
31 Mar 2022
14 Feb 2022
25 Feb 2022
14 Feb 2022
25 Feb 2022
14 Feb 2022
Amount
CN – Elemental Analyzer
PC Controlled Elemental Analyzer with all essential accessories for the quantitative analysis of Carbon, Hydrogen, Nitrogen and Sulfur in solid and liquid samples (Example- Soil, Plants and Biomass, Organic Manure etc.) based on Flash Combustion Technique followed by Gas Chromatographic/ Temperature Programmed Desorption (TPD) column Separation and Thermal Conductivity Detection through TCD or I`R Cells. Furnace: Single or Dual Furnace with automatic temperature control up to 1200°C. or more. Separation System: • Combustion gases in the form CO2, H2O, N2 and SO2 are separated by means of one Temperature Programmed Desorption (TPD) column. Baseline separation of C from N peak signal even with a concentration ratio of 12000:1 or better Detector: Thermal Conductivity Detector or Infra Red or Both Measuring range: 0 to 100% for all elements (C, H, N, S) with the capability of measuring at least 12 mg absolute carbon in CHNS mode and more than 40 mg in CN mode. Precision: <0.1 % or better with certified standards Accuracy: <0.1 % or better with certified standards System should have some important features such as: • Feature to use automatic oxygen dosage system for better combustion of any sample and no oxygen and consumables waste. • Automatic leak test. • Standby mode for gas, energy and time savings when instrument is not under operation. Carrier Gas: Must have the facility to use helium as carrier gas Analysis Time: CHN – Less than 8 minutes, CHNS – Less than 10 minutes and CN – Less than 5 minutes or better. Maximum Sample Mass: 0.2 mg to 1000 mg or more. Configurations: Several configurations such as CHNS, CHN and CN should be available for the determination of the target elements. Integrated Autosampler: • Integrated 100 or more position electronic autosampler with He-purged blank-free ball valve sample injection into the combustion furnace. • Pneumatic Autosampler will not be accepted Semi-Micro Balance: Elemental Analyzer should be equipped with a Semi-Micro Balance (reputed brand) of sensitivity up to 5 places i.e. 0.01 mg or more. CHNS Elemental Analyzer must be quoted with: • CHNS Analysis Kit for 1000 analysis including consumables/reagents. • One year of standard warranty. Necessary documents: - • Catalogue in original. • All technical specifications should be printed on the manufacturers catalogue/ data sheet. • Please include the list of minimum 10 users where the instrument is being used for similar application in India
JAIN CHEMICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .