GEMC-511687739426402
Awarded to Ramasis Energy Corporation
₹1.4 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 5KVA Online Ups Systems With 120MIN Backup | UTL-5KVA | - | 1 NOS | ₹1.4 L | 139,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.4 LQualified Make: UTL
Model: UTL-5KVA AYODHYA BYPASS ROAD BHOPAL MADHYA PRADESH 462041 | BHOPAL | MADHYA PRADESH | 462041 | Make: UTL
Model: UTL-5KVA | L1 | Qualified | |
| 2 | Disqualified Make: ACPL
Model: HFIG5000-90-12480VAH 35 A N PATH NORTH S K PURI BORING ROAD PATNA BIHAR 800013 | PATNA | BIHAR | 800013 | Make: ACPL
Model: HFIG5000-90-12480VAH | - | Disqualified | |
| 3 | Disqualified Make: AA R KEY
Model: AAR KEY 5.0 KVA 60 MINUTE ONLINE UPS MADE IN INDIA OEM BIS REGISTERED MANUFACTURE 1 PH IN PUT 1 PH OUT 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: AA R KEY
Model: AAR KEY 5.0 KVA 60 MINUTE ONLINE UPS MADE IN INDIA OEM BIS REGISTERED MANUFACTURE 1 PH IN PUT 1 PH OUT | - | Disqualified | |
| 4 | Disqualified Make: NUMERIC
Model: NUMERIC ONLINE UPS 5.0 KVA-1P/1P-60 MIN-12480 VAH-2Y-WITH Cabling 5 meters for input and out put 5 JAMUNA GANGA JAMUNA APARTMENT NR HOTEL NEST OFF C G ROAD NAVRANGPURA AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Make: NUMERIC
Model: NUMERIC ONLINE UPS 5.0 KVA-1P/1P-60 MIN-12480 VAH-2Y-WITH Cabling 5 meters for input and out put | - | Disqualified | |
| 5 | Disqualified Make: BPE
Model: BPE NIY 5KVA 12480VAH ONLINE UPS 2 YEARS AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIY 5KVA 12480VAH ONLINE UPS 2 YEARS | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Aug 2018, 5:00 pmClosed
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz
Three phase 300 V - 450V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz
3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15
30
60
90
120
180
240 Minimum VAH (VAH) 12480 12480 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without With
Without
Without trollery but with rack Warranty for battery 2 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for With With
Without 1/4 input and out put Paralleling kit for synchronising Without With
Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of Yes - 2/4 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. Will provide if required - Type Test Certificate date Will provide if required - Name of Lab Will provide if required - Address of Lab Will provide if required - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Agusthia Minj 110016
Level-5
East Block-7
Sector 1
RK Puram
New Delhi - 110066 1 15
406683
GEM/2018/B/57551
GeM Contract
Online UPS
GeM Contract
15 days
Delhi; South Delhi
PRODUCT
Awarded to Ramasis Energy Corporation
₹1.4 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| 5KVA Online Ups Systems With 120MIN Backup | UTL-5KVA | - | 1 NOS | ₹1.4 L | 139,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz | - | - | - |
| Three phase 300 V - 450V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz | - | - | - |
| 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Backup time (Minutes) 120 15 | - | - | - |
| 30 | - | - | - |
| 60 | - | - | - |
| 90 | - | - | - |
| 120 | - | - | - |
| 180 | - | - | - |
| 240 Minimum VAH (VAH) 12480 12480 Warranty for UPS (Years) 2 2 Movable trolly for Batteries Without With | - | - | - |
| Without | - | - | - |
| Without trollery but with rack Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for With With | - | - | - |
| Without 1/4 input and out put Paralleling kit for synchronising Without With | - | - | - |
| Without Installation and Commissioning Yes - CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of Yes - 2/4 (12+12) hours each 2007) Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes - Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. Will provide if required - Type Test Certificate date Will provide if required - Name of Lab Will provide if required - Address of Lab Will provide if required - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Agusthia Minj 110016 | - | - | - |
| Level-5 | - | - | - |
| East Block-7 | - | - | - |
| Sector 1 | - | - | - |
| RK Puram | - | - | - |
| New Delhi - 110066 1 15 | - | - | - |
Exempted
2 Nov 2018
31 Jul 2018
contract_GEMC-511687739426402.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_406683.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .