Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.5 LAccepted-AOC AT PO TALCHER TOWN PS TALCHER DIST ANGUL ODISHA | L-1 | Accepted-AOC AWARDED AS PER NIT | |
| 2 | L-2₹3.7 L+₹14,837.32 (4.20%)Rejected-Finance AT PO KUKUDULA PO TALCHER RLY STATION DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | L-2 | Rejected-Finance THE BIDDER IS NOT L-1 | |
| 3 | L-3₹3.9 L+₹31,738.46 (8.98%)Rejected-Finance AT REMUAN PO HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L-3 | Rejected-Finance THE BIDDER IS NOT L-1 |
Tender Value
₹5.3 L
EMD Value
₹6,700
Closing Date
16 Sept 2022, 5:00 pmClosed
SO EnM LINGARAJ AREA
OFFICE OF THE GENERAL MANAGER, LINGARAJ AREA AT/PO- DEULBERA COLLIERY, DIST- ANGUL, ODISHA, 759102
Wiring works of non-residential buildings of Rest shelter and Canteen rooms that are being renovated near Main Time Office area premises of Lingaraj OCP, Lingaraj Area
2022_MCL_255411_1
GM/LA/SO/EnM/e-Ten/22-23/21 DT-05.09.22
Open Tender
Miscellaneous Works
Item Rate
40 days
LINGARAJ OCP
AS PER NIT
4 documents required · 4 mandatory
₹6,700
29 Oct 2022
5 Sept 2022
19 Sept 2022
6 Sept 2022
16 Sept 2022
6 Sept 2022
6 Sept 2022 - 9 Sept 2022
Amount
Supply & fixing following Modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (6 amps switch).
Supply & fixing following Modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (6 amps 3 pin socket).
Supply & fixing following Modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (16 amps switch).
Supply & fixing following Modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (16 amps 6 pin socket).
Supply & fixing brass batten/ angle holder including connection etc as required.
Supply & fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply & fixing following Modular fan regulator as required.
Supply of LED Tube Light fitting etc as required.
Installation,testing and commissioning of pre wired, LED Tube light fitting of all types, complete with all accessories etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply of 18 Watt Slim Pannel LED Light fitting etc as required.
Installation,testing and commissioning of pre wired, squire LED panel light fitting of all types, complete with all accessories etc. directly on ceilingl, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supply of ceilling Fan 1200mm sweep etc as required.
Installation,testing and commissioning of Ceilling fan 1200mm sweep etc. as required.
Supply of Exhaust Fan 300mm sweep etc as required.
Supply of Exhaust Fan 450mm sweep etc as required.
Installation of exhaust fan / wall fan in the existing opening, incluiding making good the damage, connection,testing,commissioning etc. as required. Upto 450mm sweep
Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required . 20mm.
Supply & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 1 x 1.5 sq.mm.
Supply & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 1.5 sq.mm.
Supply & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 2.5 sq.mm.
Supply & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 4 sq.mm.
Supply & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required. 2 x 6 sq.mm.
Supply & fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1/2 module. (75MM X 75MM)
Supply & fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4 module.(125 X 75MM)
Supply & fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 module.(200MM X 75MM)
Supply & fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 module.(125MM X125MM)
Supply & fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 12 module.(200MM X 150MM)
Providing & fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as requir. 200 Amp ICTP
Supply & fixing 20amps,240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP,MCB, in sheet steel encloseure , on surface or in recess, with chain metal cover for the socket out let and complete with connection ,testing and commissioning etc as rerquired.
Supply & fixing 6 amps to 32 amps rating ,240/415 volts, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supply & fixing 6 amps to 32 amps rating ,240/415 volts, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supply & fixing following way, single pole and neutral, sheet stee, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.( But without MCB/RCCB/Isolator)-8 way,SPN single door
Earthing with G.I. earth pipe 2.5 Mtr long, 40mm dia., including accessories and providing masonary enclosure with cover palte having locking arrangement and watering pipe etc. with charcoal /cock and salt etc., as required.
Supply of wall fan 400mm sweep etc as required.
Total impact of GST for the purpose of CTC
R K ENGINEERING
SWASTIK ELECTRICAL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_264073.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .