Superintending Engineer
A 37 hydel colony Kavinagar Ghaziabad
RMU related work at 33/11 KV sub-stations under EDD Modinagar and Muradnagar.
2024_PVVNL_985571_1
T-32/2024-25/EDC/GZB
Open Tender
Electrical Works
Item Rate
365 days
Superintending Engineer EDC GZB
Please refer tender document
2 documents required · 2 mandatory
₹3,540
Superintending Engineer
₹86,000
16 Jan 2025
20 Dec 2024
8 Jan 2025
20 Dec 2024
8 Jan 2025
20 Dec 2024
Amount
For the work of RMU (Installation work EDD-Modinagar, EDD-Muradnagar) at various site Under Business Plan Scheme 2024-25 Part-2 in the Area of EE, EDD-Modinagar, and EE EDD-Muradnagar Ghaziabad.
Carriage of 11 KV 3X185 sqmm. XLPE Cable from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11 KV 3X185 sqmm. Cable Box O/D from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Providing Complete Construction of Plinth Standard Quality suitable for RING MAIN UNIT at various site complete in all respect as per RESPO norm.
Supply & fixing Complete Installation 12kv 630 Amps 21KA for 3 Sec. SF6 , BIL 28 KV/75 KV peak, extensible, outdoor duty 3-way, fully motorised and manually operated Ring Mains Unit originally manufactured by OEM in its factory only, comprising of 02 load break switch and 01 vaccum circuit breaker consisting of copper busbar in SF6 insulated tank with a provision electromechanical interlock to avoid accidental closure of earthing switch even when cable is in live condition. RMU should be Type Tested for Internal arc of 21 KA for 1 Sec with AFLR classification and gas to be from rear bottom of the switchgear away from the operator to ensure safety of the operating personnel. Suitable Ct 200-50/1 A with microprocessor based numerical over current relay (IDMTL + Inst.) for Protection to be provided with VCB Feeder with right angle boot for termination Kits. All the necessary wirings and Dummy panel/space for FRTU to be given along with RMU for future compatibility with SCADA system (Supply of FRTU is not in scope). Battery, Charger etc. for Motorised Operation of RMU to be provided. The scope is including Plinth/ Angle iron Stand as per OEM design complete in all respect as per the direction of Engineer incharge. Complete RMU and its accessories should be suitable for altitude of 100 mtrs above Sea Level. (Makes: ABB/Siemens/Eaton/Schneider or authorized by UPPCL) at various site complete in all respect as per RESPO norm.
Providing & Fixing Complete Installation Water Level Earthing at various site complete in all respect as per RESPO norm.
Cable Laying 3x185 sqmm by trunchless method with HDPE Pipe with Road restoration charges at various site complete in all respect as per RESPO norm.
Cable Laying 3x185 sqmm at various site complete in all respect as per RESPO norm.
Providing & Fixing Complete Installation GI Pipe 6" Dia at various site complete in all respect as per RESPO norm.
Fixing Complete Installation Cable Box 11 kv 3x185 XLPE O/D at various site complete in all respect as per RESPO norms.
Supply & Fixing Complete Installation Allumenium Crimping Lug at various site complete in all respect as per RESPO norm.
Supply & Fixing Complete Installation Nut & Bolt at various site complete in all respect as per RESPO norm.
JRA Power Gen LLP (BID ID -4837551)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .