Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.7 LAccepted-Finance | ₹50.7 L | L1 | Accepted-Finance Lowest Rate |
| 2 | L2₹51.4 LRejected-Finance | ₹51.4 L | L2 | Rejected-Finance High Rate |
| 3 | L3₹51.9 LRejected-Finance | ₹51.9 L | L3 | Rejected-Finance High Rate |
Tender Value
₹50.0 L
EMD Value
₹99,948
Closing Date
30 Mar 2026, 5:30 pmClosed
EXECUTIVE ENGINEER, PWD, DARJEELING DIVISION
OFFICE OF THE EXECUTIVE ENGINEER, PUBLIC WORKS DIRECTORATE, DARJEELING DIVISION, 8, Hooker Road, Post Box No. 59, Darjeeling 7 34 101.
Providing roof with metal sheet and renovation of first and second floor(internal) of New Science Building of Darjeeling Govt. College in the district of Darjeeling .
2026_WBPWD_1022438_1
WBPWD/EE/DJ/eNIT 21 /2025-2026
Open Tender
CIVIL WORKS
120 days
DARJEELING
Please Refer Tender Document
4 documents required · 4 mandatory
₹99,948
26 May 2026
17 Mar 2026
2 Apr 2026
17 Mar 2026
30 Mar 2026
17 Mar 2026
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. b) Extra rate for each addl. Floor over the rate of ground floor
b) Extra rate for each addl. Floor over the rate of ground floor
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.
a) In Second floor
Carriage of Brick-bats, Boulder, Stone metal, Stone chips, Gravel, Slag metal, Shingle and similar miscellaneous materials over pucca road. (Zone - B)
Dismantling carefully wooden walling, flooring of ceiling and stacking dismantled materials as directed.
Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick
Dismantling artificial stone flooring upto 50 mm. thick by carefully chiselling without damaging the base and removing rubbish as directed within a lead of 75 m
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 25 mm. thick
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. A) Pakur
Second Floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. First Floor
Second Floor
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m First Floor
Second Floor
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification][Mode of measurement:The affected surface area of reinforcement shall be considered for payment]
Renewing worn out putty of glass panes : (a) Panes not exceeding 0.2 Sq.m
Providing and fixing partition up to ceiling height consisting of G.I. frame and required board, consisting of floor and ceiling channel 50/51 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm diameter 50 mm length or suitable anchor fastener or metal screws with nylon plugs, and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of framework by 25 mm long drywall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the framework with joints staggered to avoid through cracks. M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm × 25 mm × 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacturer’s specification and direction of the Engineer-in-Charge, all complete. (ii) 70 to 71 mm overall thickness partition using 10 mm thick high pressure steam cured non-asbestos multipurpose cement board reinforced with cellulose fibre (Density > 1250 kg/m³) manufactured through autoclaving process as per IS:14862 with suitable fibre cement screws.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar (b) 15 mm thick plaster
Extra for each additional floor over the rate for ground floor items 1 to 3 of subhead A : (a) Upto 4th floor
(ii) With 1:4 cement mortar (b) 10 mm thick plaster
Extra for each additional floor over the rate for ground floor items 1 to 3 of subhead A : (a) Upto 4th floor
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. First Floor
Second Floor
Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint.
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (a) One Coat i) Water based interior grade Acrylic Primer
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface. Two Coats
Labour for taking out steel door and window frame for repairs and re-fixing the same (or replacement by new one) including mending good damages (excluding the cost of repair of damages) and applying a protective coat of paint.
Supplying, fitting and fixing windows and ventilators with or withoutintegrated grills conforming to IS 1038-1975 and manufactured fromrolled steel sections conforming to IS 7452-1974 with non-frictionprojecting type, box type hinges, glazing clips, lugs locking bracket,handle plate etc, including hoisting in position, straightening ifrequired, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality (iv) Two coats (with any shade except white)
Wooden eaves board as per design, fitted and fixed complete: In ground floor (ii) Ornamental eaves board (Ordinary Teak) (b) 25mm thick
M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 8161969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. i) For trusses spanning up to 12.00 m for roof framework to install roof sheet
Galvanised plain sheet works (excluding supporting framework) fitted and fixed with 6 mm. dia J or L hook-bolts and nuts, sheet-bolts, limpet and bitumen washers and putty with 150 mm. end lap & 50 mm minimum side lap complete. (a) In roof: with 0.63 mm. sheets
Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof: a) With 0.5 mm thick sheet
Taking out rain water pipe
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: a) Plain Tee (ii) 110 mm. Dia.
c) Bend 87.5 degree (ii) 110 mm. Dia.
d) Shoe (ii) 110 mm. Dia.
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping) (A) 300 mm lapping each way (b) With 0.63 mm sheet
Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary). (Payment to be made on area cleared)
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. a) 3.90 metre height
Extra for additional 3.6 height
Further Shifting
b) Extra for additional 3.6 height or part thereof Further Shifting
Add GST @ 18%
Add Labour Welfare Cess @ 1%
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
5784_notification.pdf
Additional Documents • 0.61 MB
BOQ_2514021.xls
BOQ • 0.32 MB
2911ii.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid