Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1,364.28Admitted-Finance 232 B OKHLA INDUSTRIAL ESTATE 3 RD FLOOR PHASE III NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | L1 | Admitted-Finance | |
| 2 | L2₹1,486.24+₹121.96 (8.94%)Admitted-Finance 1 HLL BHAVAN MAHILA MANDIRAM ROAD POOJAPPURA THIRUVANANTHAPURAM KERALA 695012 | THIRUVANANTHAPURAM | KERALA | 695012 | L2 | Admitted-Finance | |
| 3 | L3₹1,627.36+₹263.08 (19.3%)Admitted-Finance 14 4 DELHI MATHURA ROAD FARIDABAD FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | L3 | Admitted-Finance | |
| 4 | L4₹2,352+₹987.72 (72.4%)Admitted-Finance A 3 MIDC RANJANGAON GANPATI SHIRUR PUNE MAHARASHTRA 412220 | PUNE | MAHARASHTRA | 412220 | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | HLL LIFECARE LIMITED L2 | Fresenius Kabi India Pvt Ltd L4 | Poly Medicure Limited L1 | Mitra Industries Pvt. Ltd. L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-( For one unit of red cell)
1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 1 unit of red cells.
2. Filters should be having the capacity of log 4 reduction (99.99%)
3. Filters should not carry any charges it should be neutrally charged.
4. Filters material should be polyester woven / non- woven.
5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell. RBC recovery should be averaging more than 90%.
6. Filters should have hard / soft housing for optical monitoring.
7. Filtration loss should not be more than 35 ml for one unit red cell.
8. Should have integrated ≥ 40 µm, micro aggregate filter.
9. Should be US FDA/ European CE Certified.
10. Filter should have air vent, to achieve transfusion with minimum loss.
11. Packing Unit – Filter should have individual packing with bulk box pack. Quantity should be in multiple of 05 units or 40 filters per box | 50,000 | 40 Filters per Box | - | 850 ₹952 Lowest | - | - |
| 2.00 | Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-(For two unit of red cell )
1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 2 units of red cells each.
2. Filters should be having the capacity of log 4 reduction (99.99%)
3. Filters should not carry any charges it should be neutrally charged.
4. Filters material should be polyester woven / non- woven.
5. Leukocytes should be consistently averaging less than 0.2*106 for two units of red cell. RBC recovery should be averaging more than 90%.
6. Filters should have hard / soft housing for optical monitoring.
7. Filtration loss should not be more than 35 ml for one unit red cell.
8. Should have integrated ≥ 40 µm, micro aggregate filter.
9. Should be US FDA/ European CE Certified. | 40,000 | 40 Filters per Box | - | 1,250 ₹1,400 Lowest | - | - |
| 3.00 | Single Blood Bags {350ml)
General Specifications Annexure- XVI and Specification in Annexure-XVII | 1,50,000 | Each Piece | 59 ₹66.08 | - | 58.91 ₹65.98 Lowest | 69 ₹77.28 |
| 4.00 | Double Blood Bags with SAGM (350ml)
General Specifications Annexure- XVI and Specification in Annexure-XVIII | 2,00,000 | Each Piece | 166 ₹185.92 | - | 160.65 ₹179.93 Lowest | 182 ₹203.84 |
| 5.00 | Double Blood Bags with SAGM (450ml)
General Specifications Annexure- XVI and Specification in Annexure-XIX | 1,50,000 | Each Piece | 166 ₹185.92 | - | 163.8 ₹183.46 Lowest | 182 ₹203.84 |
| 6.00 | Triple Blood Bags with SAGM (350ml)
General Specifications Annexure- XVI and Specification in Annexure-XX | 3,00,000 | Each Piece | 203 ₹227.36 | - | 173.25 ₹194.04 Lowest | 220 ₹246.4 |
| 7.00 | Triple Blood Bags with SAGM (450ml)
General Specifications Annexure- XVI and Specification in Annexure-XXI | 1,00,000 | Each Piece | 203 ₹227.36 | - | 182.7 ₹204.62 Lowest | 220 ₹246.4 |
| 8.00 | Quadruple Blood Bags with SAGM (350ml)
General Specifications Annexure- XVI and Specification in Annexure-XXII | 30,000 | Each Piece | 265 ₹296.8 | - | 236.25 ₹264.6 Lowest | 290 ₹324.8 |
| 9.00 | Quadruple Blood Bags with SAGM (450ml)
General Specifications Annexure- XVI and Specification in Annexure-XXIII | 20,000 | Each Piece | 265 ₹296.8 | - | 242.55 ₹271.66 Lowest | 290 ₹324.8 |
| 10.00 | VDRL Antigen (with +ve and -ve control) / RPR slide Kit | 15,06,718 | 100 Test Kits | - | - | - | - |
Tender Value
₹40.2 Cr
EMD Value
₹5 L
Closing Date
23 Apr 2024, 6:00 pmClosed
MD RMSCL
Conference Hall RMSCL, Swasthyabhawan, Tilak Marg, Jaipur
E-Bid For Rate Contract Cum Supply and Empanelment of Surgicals and Suture (Drug Items)
2024_RMSCL_387872_1
F 02 165/RMSCL/Proc/SS MD/NIB-06/2024/3439 Dated
Open Tender
Supply of Materials/Hiring of Goods
Item Wise
90 days
All DDW of Rajasthan
Manufacturing Lic, PP, MSC, NCC, GMP/WHO-GMP, Performance Statement, Turn Over, Bid Security, RISL Fee, Bid Forms Fees and All Annexure, etc.
4 documents required · 4 mandatory
₹2,360
MD RMSCL
₹5 L
Yes
RMSCL Board Room
30 Jul 2024
9 Mar 2024
24 Apr 2024
9 Mar 2024
23 Apr 2024
26 Mar 2024
19 Mar 2024
Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-( For one unit of red cell) 1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 1 unit of red cells. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.5x105 residual leucocytes for one unit of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated ≥ 40 µm, micro aggregate filter. 9. Should be US FDA/ European CE Certified. 10. Filter should have air vent, to achieve transfusion with minimum loss. 11. Packing Unit – Filter should have individual packing with bulk box pack. Quantity should be in multiple of 05 units or 40 filters per box
Specifications of Bed side Leucodepletion Filters for Blood Transfusion:-(For two unit of red cell ) 1. Filters should be able to leuco-deplete red cells form leukocyte contamination separately for 2 units of red cells each. 2. Filters should be having the capacity of log 4 reduction (99.99%) 3. Filters should not carry any charges it should be neutrally charged. 4. Filters material should be polyester woven / non- woven. 5. Leukocytes should be consistently averaging less than 0.2*106 for two units of red cell. RBC recovery should be averaging more than 90%. 6. Filters should have hard / soft housing for optical monitoring. 7. Filtration loss should not be more than 35 ml for one unit red cell. 8. Should have integrated ≥ 40 µm, micro aggregate filter. 9. Should be US FDA/ European CE Certified.
Single Blood Bags {350ml) General Specifications Annexure- XVI and Specification in Annexure-XVII
Double Blood Bags with SAGM (350ml) General Specifications Annexure- XVI and Specification in Annexure-XVIII
Double Blood Bags with SAGM (450ml) General Specifications Annexure- XVI and Specification in Annexure-XIX
Triple Blood Bags with SAGM (350ml) General Specifications Annexure- XVI and Specification in Annexure-XX
Triple Blood Bags with SAGM (450ml) General Specifications Annexure- XVI and Specification in Annexure-XXI
Quadruple Blood Bags with SAGM (350ml) General Specifications Annexure- XVI and Specification in Annexure-XXII
Quadruple Blood Bags with SAGM (450ml) General Specifications Annexure- XVI and Specification in Annexure-XXIII
VDRL Antigen (with +ve and -ve control) / RPR slide Kit
HLL LIFECARE LIMITED
Mitra Industries Pvt. Ltd.
Fresenius Kabi India Pvt Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
TENDER.pdf
Tender Documents • 2.87 MB
BOQ_691206.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .