Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC Contract Awarded | |
| 2 | L2₹46.0 L+₹4.5 L (10.9%)Rejected-Finance | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹46.7 L+₹5.2 L (12.4%)Rejected-Finance MOHAMMADPUR CHAIL KAUSHAMBI UTTAR PRADESH 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L3 | Rejected-Finance Other than L1 bidder | |
| 4 | Rejected-Technical 80 G HIMMATGANJ PRAYAGRAJ U P PIN 211016 | PRAYAGRAJ | UTTAR PRADESH | 211016 | - | Rejected-Technical Rejected as not fulfilling the NIT Criteria | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected as not fulfilling the NIT Criteria |
| Sl No | Description | Qty | Unit | HARSH ASSOCIETES L3 | Technological Associates L1 | DINESH ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth, for foundation etc n.exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and directed. | 78.4 | Cum | 360 ₹28,224 | 300 ₹23,520 Lowest | 360 ₹28,224 |
| 2.00 | Description same all as per Item No 1.00 here in above for each additional 1.5m or part thereof in depth beyond the first 1.5 mtr complete all as specified and directed. | 1.2 | Cum | 425 ₹510 | 400 ₹480 Lowest | 415 ₹498 |
| 3.00 | Excavation in post holes in soft/loose soil ( or similar holes) each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance n.exc 50 M complete all as specified. | 2 | Each | 140 ₹280 Lowest | 150 ₹300 | 155 ₹310 |
| 4.00 | M&L for Cement concrete 1:4:8 Type D-2 using 40 mm graded stone aggrgate in foundations, filling and mass concrete complete all as specified and directed. | 25.01 | Cum | 3,850 ₹96,288.5 | 3,800 ₹95,038 Lowest | 3,850 ₹96,288.5 |
| 5.00 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facing, dressed stone work and precast concrete articles etc complete all as specified and directed | 12.42 | Cum | 560 ₹6,955.2 | 550 ₹6,831 Lowest | 560 ₹6,955.2 |
| 6.00 | M&L for brick work with sub class-B old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. | 40.67 | Cum | 4,400 ₹1,78,948 | 4,000 ₹1,62,680 Lowest | 4,250 ₹1,72,847.5 |
| 7.00 | M&L for brick work with sub class- B old size bricks (except bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Note: bricks obtained from demolition shall be used. | 4.83 | Cum | 1,280 ₹6,182.4 | 1,250 ₹6,037.5 Lowest | 1,300 ₹6,279 |
| 8.00 | M&L for Reinforced Cement concrete (Nominal Mix) type B-1 using 20 mm graded aggregate as in Slabs supported on walls, canopies, deck slabs and in shelves and the like complete all as specified and directed. | 5.24 | Cum | 7,800 ₹40,872 | 7,500 ₹39,300 Lowest | 7,850 ₹41,134 |
| 9.00 | M&L for Reinforced Cement concrete (Nominal Mix) type B-1 using 20 mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. | 5.49 | Cum | 7,800 ₹42,822 | 7,500 ₹41,175 Lowest | 7,850 ₹43,096.5 |
| 10.00 | Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete complete all as specified and directed. | 110.28 | Sqm | 360 ₹39,700.8 | 350 ₹38,598 Lowest | 360 ₹39,700.8 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
10 Dec 2025, 6:00 pmClosed
GE WEST PRAYAGRAJ
Garrison Engineer (West), New Canttt, Prayagraj-211001
ADDITION/ALTERATION CUM SPECIAL REPAIR TO PENSIONER WAITING AREA OF RECEPTION BUILDING AT PCDA (PENSION), PROVISION OF 01 TOILET BLOCK CONSISTING OF 04 X TOILET WITH COMPLETE FITTING/FIXTURE FOR PATIENT NEAR PAED OPD AT MIL HOSP PRAYAGRAJ AND PROVN
2025_MES_732935_2
8861/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT PRAYAGRAJ
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE WEST PRAYAGRAJ
₹99,000
Yes
7 Mar 2026
26 Nov 2025
17 Dec 2025
26 Nov 2025
10 Dec 2025
3 Dec 2025
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth, for foundation etc n.exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out soft/loose soil complete all as specified and directed.
Description same all as per Item No 1.00 here in above for each additional 1.5m or part thereof in depth beyond the first 1.5 mtr complete all as specified and directed.
Excavation in post holes in soft/loose soil ( or similar holes) each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance n.exc 50 M complete all as specified.
M&L for Cement concrete 1:4:8 Type D-2 using 40 mm graded stone aggrgate in foundations, filling and mass concrete complete all as specified and directed.
Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facing, dressed stone work and precast concrete articles etc complete all as specified and directed
M&L for brick work with sub class-B old size bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class- B old size bricks (except bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. Note: bricks obtained from demolition shall be used.
M&L for Reinforced Cement concrete (Nominal Mix) type B-1 using 20 mm graded aggregate as in Slabs supported on walls, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for Reinforced Cement concrete (Nominal Mix) type B-1 using 20 mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C-2, using 40mm graded crushed stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttrresses, columns, pillars, boundry pillars and posts (including, caps and bases) complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm depth complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Removing excavated material exc. 250m but n exc 500 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for ooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Description same all as per item No. 16 here in above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for 40 mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregate mixed with liquid WPC as per manufacturer instructions over Polythene film, 200 micron thick, over a coat of blown bitumen of grade 85/25 (VG-40)@ 1.50 kg per square metre and blinding with clean dry sand @ 0.80 Kg/Sqm complete all as specified and directed. Note: Liquid WPC shall be measured and paid seperatly.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surface finished even and smooth without using extra cement mixed with liquid WPC as per manufacturer instructions complete all as specified and directed. Note: Liquid WPC shall be measured and paid seperatly.
Supply only liquid Water proofing compound (ISI Marked) complete all as specified and directed.
Taking down cement or cement lime plaster any description from walls/ceiling etc including racking out joints, hacking for key & scrubbing down with water including removing of debries out side of MOD land complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick/concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and directed.
M&L for Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
Dismantling of stone slab and tiles laid bedded and pointed of any description or thickness in floors, aprons etc complete all as specified and directed.
S&F for heavy duty exterior finish designer pavement tiles, coloured, superior quality, 300x300x10mm thick as in floors/ pavement etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F for glazed ceramic tiles, coloured First/superior quality 300x450x6 to 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match as in vertical surface including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engr-in-charge.
S&F vitrified tiles, light shade 8 to 9mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F for vitrified tiles, light shade, 8 to 9mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in vertical surfaces such as Dado/Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick screed bed in CM 1:3 complete all as specified and directed.
M&L for Granite 14-16 mm thick (of any type) work (table rubbed and polilshed) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white ecment (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified.
M&L for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof padding, in leveling course, benching, mud stops etc, complete all as specified and directed
S&F in repair 4mm thick E-boards tiles false ceiling with powder coated GI snap grid frame work including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type B0/Cement mortar 1:3 complete all as specified and directed including all necessary drilling and necessary arrangement to fix electrical items as under:- (a) 25x25x1.6 mm thick GI angle powder coated duly plugged @ 600mm centre to centre along perimeter of wall. (b) 25x25x1.5 mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders with adjustable clamps and dash free fasteners plugging in RCC slab placed @ 600mm centre to centre from perimeter of wall. (c) Fixing of 4 mm thick E-boards tiles of size 595 mm x 595 mm of approved texture and finished complete with two coats of oil emulsion distemper on ceiling. NOTE: The complete ceiling work shall be done as per manufactures instruction and as directed.
M&L for 1 mm thick wall care putty on external and internal wall over newly plastered surfaces complete all as specified and directed.
M&L for preparing old painted surfaces of steel of any description not otherwise described, surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing new plasterd surfaces of wall and applying two or more coats of Acrylic Smooth exterior paint of required shade applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre /10 sqm complete all as specified and directed.
M&L for two coats of oil bound distemper over chalk whiting on newly plastered surface of wall and cornices including preparation of surfaces complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide Zinc chrome primer complete all as specified and directed.
Dismantling boarding aluminium partition, any type ,size and in position and removing to store complete all as specified and directed.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 X 100 mm single rebated comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F for Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note : stainless steel butt hinges and necessary S S screws shall be paid separately.
Supply and fixing /fabrication kitchen cabinet & wardrobe/ cupboard made out of 16 to 18 mm thick coloured PVC board laminated sheet complete all as specified and directed. Make : Rajshree or equivalent all as specified and approved by Accepting Officer.
Supply and fixing /fabrication kitchen cabinet & wardrobe/ cupboard made out of 16 to 18 mm thick plain PVC sheet complete all as specified and directed. Make : Rajshree or equivalent all as specified and approved by Accepting Officer.
S&F for magnetic catches with steel body 'H' type fixed to shutter complete all as specified and directed.
S&F for continues (piano) hinges, mild steel, bright finish width of flap (when open) 30mm complete all as specified and directed.
S&F for brass Locks for cupboard, grade I, size 50 mm, 2 levers with necessary accessories complete all as specifed and directed.
S&F for channel 18/20 inch length extruded Stainless Steel over rollers for kitchen of approved make complete all as specified and directed.
S&F for powder coated aluminium partition, fixed type without sash bar, aluminium section of 63.50 x 38.10 mm weighing not less than 0.75 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws , 4 mm thick tinted glass /APP board etc. complete all as specified and directed.
S&F for Aluminum powder coated grill of size 75x75x4 mm thick for windows, incl joining cleat, anodised aluminium strip beading, necessary screws complete all as specified and directed.
S&F for Anodised aluminium frame for doors, windows, ventilators including joining cleat for fixing etc complete all as specified and directed.
S&F for Brass Mortice Lock, 4-6 Lever fixed to aluminium doors complete all as specified and directed.
S&F for aluminium (Die cast) body Door closer hydraulically regulated, designation No. 2,universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg complete all as specified and directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box with stainless steel cover fixed to Aluminium doors complete all as specified and directed.
S&F for 125 mm long, 12 mm dia SS Dash fasteners for door frames etc incl necessary drilling etc complete all as specified and directed.
S&F for 250mm long SS, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections suitable for use with pad lock complete all as specified and directed.
S&F for 125 mm size SS butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F for 150mm size SS handle, fabricated type, fixed with screws complete all as specified and directed.
S&F for 100mm size SS handle, fabricated type, fixed with screws complete all as specified and directed.
S&F for 200mm size SS tower bolt, fabricated type, fixed with screws complete all as specified and directed.
S&F for Rubber door seal 32mm wide with Aluminium strip of size 19mm wide fixed with machine steel screw with washer, complete all as specified and directed.
S&F for SS door stopper double 75mm long having rubber bush 25mm dia fixed to door shutter with steel screw complete all as specified.
S&F for 15mm bore Steel water tubing 'medium grade', galvanised with all fittings like elbow, tee, socket, bend etc and fixed to wall, ceiling or laid in floor complete all as specified and directed.
Cutting chases in brick work, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing or concealed conduit wiring, etc., and making good, (cutting not exc 10cm girth) complete all as specified and directed
S&F for 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, , laid in trenches or in floors complete all as specified and directed.
S&F for 75mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, , laid in trenches or in floors complete all as specified and directed.
S&F for PVC (SWR) floor trap plain with SS grating any radius suitable for 75mm bore PVC pipe jointed with solvent complete all as specified and directed.
S&F for fancy type bib taps long body cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed.
S&F for brass chromium plated waste coupling for S.S Sink with rubber washer plug etc complete all as specified and directed.
S&F for stainless steel sink, made out of 1.00 mm thick stainless steel sheet conforming to AISI 304 with plug, washers, wastes, cast iron cantilever brackets, connecting union with bowl internal size 550 mm x 400mm x 250 mm complete all as specified and directed.
Supply only 32/40mm bore PTMT waste pipe of best quality,600mm long for wash basin and sink etc complete all as specified and directed.
S&F for Aluminium composite panel sheet 3mm thick (plain, coloured, spl colour/textured as directed) fixed with necessary alumium tube of size 25 mm x38 mm x 1.5 mm with required silicon & screw as in ceiling, columns etc in vertical surfaces complete all as specified and directed.
S&F for SS Steel letters having text height of 45 cm of adequate thickness and fixing on reuired height incl all necessary screws, fasteners etc complete all as specified and directed.
S&F for mild steel work with angle iron, flat iron, channel etc. as in post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (For securing wire mesh etc) including all necessary drilling, bolting or riveting etc, and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for Cutting holes of superficial area n exc 150 sq cm into or through brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed.
Treating ends of posts, backs of chowkats, etc area tarred exc 0.1 sq. m but n exc 0.5 sq. m each complete all as specified & directed.
S&F concertina coil 600 mm dia (stretched position) hot dip galvanised including "U" and "C" clip, having 50 Nos of spirals in 8 mtr stretch length and composed of reinforced punched razor ribbon sides of cold rolled low carbon steel fixing of the "Y" of trapezoidal shaped angle iron brackets placed at 2.5 to 3 meter apart complete all as specified, shown in drawings and as directed. The barbs should have 180 degree straightness, razor edge cut with following specifications :- (i) Concertina coil confirming to IS-513, IS-4454 (Part-1) and IS-12753 (ii) Clips-18 SWG GI (iii) Wire dia-2.60 mm (iv) Razor blade tape length-20 mm (minimum) (v) Razor blade tape width- 14 mm (minimum) vi) Razor blade thickness- 0.50 mm (vii) Clips per round of circle-05 Nos (viii) Zinc coating- 230 to 240 GSM heavy coating hot dip (ix) Tensile strength-1620 N/ Sqmm (minimum) Note : (a) Horizontal razor wire and angle iron supports will be measured and paid separately under relevant items of Sch 'A'/ BOQ. (b) Measurement will be made for stretched length.
S&F hot dip galvanised razor wire fencing with 2.60 mm dia centre core wire having barbs of length 20mm (minimum), width 14mm (minimum) and thickness 50mm razor strip on swan neck angle iron and fixing with antirust clamps on angle iron post including all fittings like fastener clips, steel leg rings etc as shown in drawing complete all as specified and directed. The barbs should have 180 degree straightness, razor edge cut with following specifications :- (i) Razor wire confirming to IS-513, IS 4454 Part-I and IS-12753 (ii) Zink coating- 230 to 240 GSM heavy coating hot dip. (iii) Tensile strength- 1620 N/Sqmm (minimum) Note : Each line of wire will be measured for payment purpose.
Surface dressing n. exc. 15 cm deep in soft / loose soil and getting out exceeding 50 Mtr in soil complete all as specified & directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed .
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in chajjas, shelves etc and the like, complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in plinth protection finished even and smooth without using extra cement including necessary formwork and cutting of joints complete all as specified & directed.
Use and waste formwork to sides of foundation including rough finished surfaces of concrete complete all as specified and directed
Use and waste formwork to sides of column including rough finished surfaces of concrete complete all as specified and directed
Use and waste formwork to sides of slab including rough finished surfaces of concrete complete all as specified & directed.
Use and waste formwork to sides of Chajja including rough finished surfaces of concrete complete all as specified & directed.
Use and waste formwork to edges of rough finished surface of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete
M&L for Brick work with fly ash old size bricks, straight or curved on plan to any radius in built in cement mortar 1:6 complete all as specified & directed.
M&L for half brick thick wall fly ash bricks (old size), straight or curved on plan to any radius, built in cement mortar 1:4 complete all as specified and as directed
M&L for 5 mm thick rendering in cement mortar (1:3), finished even and fair without using extra cement on brick or concrete surfaces of ceiling complete all as specified and directed.
M&L for 10mm thick plaster in (1:4) cement mortar on green concrete surfaces of roof with WPC. Note : WPC should be measured and paid separately)
M&L for hardcore of gauge n exc. 63 mm,of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B-1 (using 20mm graded crushed stone agg) in floor complete all as specified & directed.
S&F solid PVC door frame of size 50mm x 95mm made out of 5mm single side prelam PVC sheet reinforced with MS tube in opening as per specification and shown in drg in SSR Part -II 2010
S&F for Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded prelam PVC Sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing.
S&F for stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed.
S&F for stainless steel handle 200mm long complete fixed with steel screws complete all as specified & directed.
S&F for 100mm size stainless steel butt hinges complete all as specified and directed.
S&F for rotational moulded,multilayer HDPE water storage tank of 1000 ltrs capacity (Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia PTMT float valve epoxy coated Aluminium rod with high density plastic float ball (of minium weight 210 gms) etc complete all as specified and as directed.
S&F for vitreous china wash down water closet pan pedestal pattern white including connection in drain and in flushing pipe complete including 'P' or 'S' trap complete all as specified & directed.
S&F for Plastic water closet seat cover white closed pattern with flat bottom and cover with MS Chromium plated hinge twice ISI marked as approved.
S&F for vitreous china urinal, half stall type (flat back), of size 635x395x420mm, white, with grating and union for discharge pipe (excluding flushing cistern) including 32mm dia PTMT coupling and waste pipe, CP spreader providing and fixing plugs, bedding urinal against wall in CM 1:2, complete all as specified and directed.
S&F for two way bib tap with flange 15mm bore, fancy type, quarter turn, cast copper alloy, chromium plated with long shank and cup screwed down, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F for 15mm dia health faucet ABS body with 08mm dia , 01 mtr long flexible tube & wall hook complete all as specified & directed.
S&F for CP toilet paper holder fixed to walls with chromium plated brass screws complete all as specified & directed.
S&F for stainless steel railing of quality 304 any size and design complete all as specified and directed
S&F for GI tubing medium grade 20mm dia with all fittings, cutting, threading and fixing to walls or fixing in concealed walls or in floors etc. and making good the surfaces matching to existing surfaces of walls/floor complete all as specified & directed.
S&F for 20mm dia Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
S&F for 15mm bore angle valve CP wall with quarter turn flange, brass chromium plated fancy type complete all as specified and directed.
S&F for 10 litre capacity PVC low level cistern ‘ white’ with inlet, float valve including bracket with 32mm dia PVC pipe 600 mm long complete all as specified & directed.
S&F for PVC connection 450mm long and15 mm dia with brass fly nut at both ends complete all as specified & directed.
S&F for vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on MS bracket including cutting for and pinning in ends of brackets or erecting stand including fixing of 32mm CP waste coupling, 32mm waste pipe, waste fitting,pipe and union complete all as specified and directed.
S&F for CP bottle trap (with internal partition 32 mm Size with 300 mm & 190 mm long wall connection pipe and wll flange complete all as specified and directed.
S&F for 5mm thick looking mirror with bevelled edges including suitable SS studs complete all as specified and directed
S&F for fancy type Pillar tap 15mm bore, cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F for Tubular towel rail of brass chromium plated, 20 mm dia, 'D' type, 60 cm long between flanges complete all as specified & directed.
S&F for PVC (SWR) 110mm bore bend, any radius complete all as specified & directed.
S&F for PVC (SWR) junction single (single T), equal or unequal, 110 mm bore, provided with access door complete all as specified & directed.
M&L for joint free non skid, ceramic “coloured” tiles 7 to 8 mm thick area of each tile of size 300mm x 300mm in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified & directed.
M&L for Providing and laying 12-15 mm thick factory made heavy duty designer endura floor tiles size not less than 400x400mm with approved colour, design and pattern as in footpath, parks, lawns etc of required strength, jointed and pointed in neat cement slurry and pigments in floors including 15mm thick screed bed in CM 1:4 complete all as specified and directed
Supply & applying High build elastomeric waterproofing coating based on pure, hydrophobic polyurethane, cold applied of spray / brush applied, SmartCare PU Magnum membrane with an elongation of 550% and tensile strength of 2.5 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, no leakage upto 7 bars of water pressure as per DIN 1048, shore A Hardness of min. 45 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare PU Magnum or approved equivalent in two coats with a consumption of 1.5 Kg per SQM on a primed surface with SmartCare Primer and a 40 GSM geo textile cloth sandwiched in between, etc, complete as per Manufacturer's specifications
M&L for brick work with fly ash brick built in cement mortar (1:4) straight or curved on plan exc 6m mean radius for man holes complete all as specified.
M&L for concrete bed to drain pipes in PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate including packing under and haunching against the sides of pipes after are laid in step and tested for 150 mm bore sewer line complete all as specified & directed. Note: (excavation and earth work for sewer pipe line measured and paid separately)
M&L in repair 150 mm dia Reinforced concrete pipes, class NP3, laid and jointed complete all as specified & directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) in surface channels and drain complete all as specified and directed at site.
M&L for pre cast RCC type B-1 (1:2:4) using 20mm graded stone aggregate for cover slab of manhole complete all as specified and shown on drgs and slab set in cm (1:4) including necessary form work complete all as specified & directed.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for Point wiring complete in modular switch, socket with 1.5 Sq mm (nominal area) PVC insulated flame retardent low smoke un-sheathed and multicore copper conductor cable with colour code ISI marked in and including PVC concealed conduit ISI marked and conduit fittings for one light point/fan point/engagement light controlled by one switch including PVC insulated 1.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable Anodized sunken box as per manufacture design and plate for modular of switch , socket etc with grid plate, crown with captive screws complete all as specified & directed. Note : Rate is inclusive of Cutting/chases of wall/floor/ceiling.
Description same all as per Item No 140 here in above but one three pin switch socket outlet 5 Amps on the independant board complete all as specified and directed.
Description same all as per Item No 140 here in above but wiring with 2.5 sq.mm multistranded cable and earth wire with copper conductor of size 2.5 sq.mm for 15 amps power point complete all as specified & directed.
S&F in replacment of modular switch 1 way, 5/6 amps, 230V AC, one way complete all as specified & directed.
S&F in replacment of modular socket out let 2-in-1, 3 pin, 5/6 amp flush type 2 module complete all as specified & directed.
S&F in replacment of modular Switch out let 2-in-1, 3 pin, 15/16 amp flush type 2 module complete all as specified & directed.
S&F in replacment of modular socket out let 2-in-1, 3 pin, 5 /16 amp flush type 2 module complete all as specified & directed.
S&F for Ceiling rose, surface bakelite 2 to 3 terminal, 240 volts, 5 Amps ISI Marked complete all as specified & directed.
Supply and fix Wall mounting fan 230V of size 450mm 2000 RPM , 95 CMM Smooth oscillation & running with pull controlled high speed motor for higher air delivary and Airodynamically designed balanced heavy duty PP blades self regulator mounting on wall/surface with wall hook /clamps fixed with proper screws/nuts washers etc and connecting up with 5A switch socket outlet point as per user requirement complete all as specified & directed.
M&L for energy saver LED battan fitting 20 watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting complete all as specified & directed. Make : Philips Essential SmartBright BN170C LED20S-6500 PSU L120 or equivalent makes as approved by GE
Supply and fixing in replacement of 36 W LED,6500K 2'x2' Panel Ultra slim recess mounted LED module with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling applications complete all as specified & directed by Engr-in-Charge. Make -Philips Cat part No: Full glow RC380B LED36S-6500 G6 L60W60 PSU OD S1 or equivalent makes as approved by GE
S&F in Replacement of double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with suitable rating bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified & directed. Make Legrand/C&S /HAVELLS equivelant makes approved by GE
S&F for sheet metal enclosure TPNL MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCBs & MCCB 125 Amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified & directed. Make : Legrand or equivalent makes as approved by GE
Supply and fix in replacement MCCB 125 Amps fixed thermal fixed magnetic setting, 415 volts, 10KA, complete all as specified and directed. Make: Legrand/C&S/Havells or equivalent makes as approved by GE
S&F in replacement of MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating complete all as specified & directed. Make Legrand /Havells/C&S or equivelant makes approved by GE
S&F in replacement of MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40/63 Amps complete all as specified & directed. Make Legrand/Havells/ C&S or equivelant makes approved by GE
Supply and install air cooled split type Air conditioner electric driven single phase 50 HZ,with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star inverter rating and EER 3.2.of capacity as 1.5 Ton complete by indoor unit on wall of room and out door unit out side exposed to open space on surface with suitable foundation or wall with proper fixer including insulating all the refriferent piping complete all as specified and directed for Pensioner waiting area of Reception Building. Make: LG/Voltas /Bluestar or equivelant makes approved by GE
S&F in replacement of Voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230 V 50Hz with accuracy of ± 2.5% and of capacity 5.0 KVA. Make : Blue star/Vinitec/V-guard or equivelent approved makes.
S&F in replacement of Three pin metalic plug & socket 20A outlet for SP/DP MCB and 2 pole and Earth Metal enclsoure complete all as specified & directed. Make : Havells Cat part no DHDPUSN020/DHDPUDP020 or equivelent make approved by GE
S&F in replacement of High power LED Security light fitting 24 watt 5000 k, IP>66 , IK>07 grey powder coated die cast aluminium housing , inbuilt energy efficent surge protected electronic driver, with all connected accessories complete all as specified & directed. Make: Philips, Cat No : BRP330 LED24 CW R5N PC PSU S1 V1 or equivalent makes as approved by GE
S&F in replacement GI pipe 40/50 mm bore, light grade, 1.50 metres long, bent to shape required as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts complete all as specified and as directed.
M&L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including suitable size non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire connected to common earth dolly complete all as specified and directed.
M&L for sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in PVC conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified & directed. Make of wire: Polycab/RR cable/Finolex or equivelant makes approved by GE
Supply & laying or fixing or laid in trench/ducts/through pipes/in floors/under roads/under hard standing/along poles and testing cross linked polytehylene (XLPE) LT cable XLPE insulated, PVC inner sheathed, bedded, galvanised steel strip or wire armoured heavy duty 1100 V grade with stranded aluminium conductor having cross sectional area 35 Sqmm 3.5 core and conforming to IS-7098(Part-I-1988 & as per latest amendments) complete all as specified & directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
M&L for point wiring with concealed in wall 1.5 sqmm (nominal area) FRLSH PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade of appropriate size concealed in wall and modular sunken box, cover plate/frame any module as required at site with all accessories as specified including 1.5 Sqmm FRLSH PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dolly for 5 Amps socket indepent board, 5 Amp same board and fan / light / exjaust fan/ bell point controlled by one switch and single conduit shall be used for each circuit complete all as specified & directed. Note :- 1. Cost of PVC conduit, with connected item to be included in the quoted rate. 2. M&L for cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate. 3. Modular metal box, cover plate & frame for any module to be included in the quoted rate.
Description same all as per item No. 165 here-in- before but for 3 pin 15 Amps switch socket n on independent board with 4 sq mm copper cable including 4 Sqmm FR PVC insulated unsheathed multistranded copper earth conductor to common earth complete all as specified & directed.
S&F for modular switch 1 way, 6 amps, 230V AC, one way complete all as specified & directed.
S&F for modular socket out let 2-in-1, 3 pin, 6 amp flush type 2 module complete all as specified & directed.
S&F for Exhaust fan 300 mm sweep AC single phase 230 V Metallic steel body Range complete with lades, frames, and louvers including required length and size of copper stranded conductor for connection from ceiling rose to connector of fan with provn of making hole in wall complete with grouting of nuts, bolts and washers and all other accessories required for fixing of fan including testing on completion complete all as specified & directed.
S&F for MCB single pole & neutral 40 to 63 amp, 240 volts, 'B' series, 10 KA breaking capacity & connection in DB complete all as specified and directed.
S&F for MCB single pole 6 to 32 Amp amp, 240 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with dim rail earth and neutral bar complete all as specified & directed.
Supply and fixing indoor luminare decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 20 W incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
S&F in replacement of existing worn out LED mirror light fitting 10 watt mirror type with high output with opal diffuser 230 V AC decorative type with driver holder and LED lamp including connecting with three core flrxible copper conductor cable of suitable size complete all as specified by Engr-in-charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as spd and directed.
M&L for 40 mm dia GI tubing light grade with all necessary fittings laid in trenches, fixed to walls/ poles/ under road/ floor etc for cable protection, complete all as specified and directed.
M&L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.
Supply and laying of well burnt bricks, sub class 'B' laid flat in trenches for protection of cable complete all as specified and directed.
Supply and fixing LED Bldg Security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including bracket for light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete.
Cutting existing steel tubing for alternation or addition and screwing existing steel tubing for alteration or addition lengthening screw on pipe to form connector of size 40/50 mm dia.
M&L for steel water tubing medium grade galvanised with new fitting laid in trenches for the 40 mm size complete all as specified and directed.
M&L for steel water tubing medium grade galvanised with new fitting laid in trenches for the 25mm size complete all as specified and directed.
S&F for gun metal globe or gate valve 40mm bore pipe with iron wheel head screwed both ends for iron pipe as fixed in repairs complete including dismantling unserviceable one complete all as specified & directed.
S&F for ceiling fan 1200mm sweep, 240 V AC, energy efficient BEE 5 star rating BLDC with 3 Blade and connecting with twin core PVC insulated multi stranded flexible copper conductor wire from ceiling rose to fan of length not less than 1 mtr with down rod as site requirement, fan connector/ fan hook for necessary required fixing arrangement complete all as specified & directed. Note: Copper wire and down rod include this item.
Supply, Fixing & testing Geyser electric water heater,storage type steel body with heating element upto 2KW,BEE 5 star rated ,25 Ltr capacity with all accessories such as safety valve, thermostate,NRV, PVC connection pipe heavy duty hot water supply (wired)-01 No and inlet cold water pipe complete of size 600mm length-01 No incl grouting of suitable anchor nuts, bolts not lessthan 10mm dia and 100mm long as per site requirement and all other accessories for fixing of geyser electrically, plumbing complete all as specified and directed.
S&F for Angle Stop Valve fancy type screwed down, high pressur, chromium plated with long shank and cup (concealed type) screwed both ends for iron pipes or for unions, 15 mm dia of pipe complete all as specified and directed.
S&F for Bib Tap, cast copper alloy with fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity complete all as specified & directed.
S&F for Switch piano flush type, 5 amps, 230V AC,single pole, one way complete all as specified & directed.
M&L for submain wiring with two single core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in concealed PVC conduit 20mm dia/PVC casing capping as per site requirement in wall surface for sub main connection including 6 sqmm FRLS PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified and directed. Note : Two single core 6.0 sqmm copper conductor, one run PVC conduit and one run of 6.0 Sqmm earth wire shall be considered and measured as one unit.
S&F in replacment of factory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42), suitable for mounting MCBs confirming to IS-13032, IS-8623, BS-5484 with suitable rating bus bar ,SP&N 4 ways ,220 volts complete all as specified and directed. Note : MCB/ shall be measured and paid seperatly under respective item of this schedule
S&F in replacment of 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
Schedule of Credit (MINUS) Rs. 25,013.00 B/F from Serial Page No. ____ [Note : Details of items for schedule of credit is given on Srl Page No. ___] This amount shall be automatically deducted to arrive at tendered sum
DINESH ELECTRICALS (BID ID -3493430)
HARSH ASSOCIETES (BID ID -3489411)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
BOQ_830452.xls
BOQ • 0.42 MB
TenderDocus8861_2.pdf
Tender Documents • 0.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .