Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.6 LAccepted-AOC | ₹38.6 L | 1 | Accepted-AOC Lowest Bidder |
| 2 | 2₹39.4 L+₹77,193.91 (2.00%)Rejected-Finance | ₹39.4 L+₹77,193.91 (2.00%) | 2 | Rejected-Finance 2nd Lowest Bidder |
Tender Value
₹38.6 L
EMD Value
₹77,500
Closing Date
21 Jan 2026, 2:00 pmClosed
EEE EWD Dumka
Dumka
S/R to E.I. in Administrative, Workshopand Provision of 3 phase industrial wiring for machine in I.T.I. at Pakur.
2026_ENRGY_109013_5
Energy/EWD/Dumka/25/2025-26
Open Tender
Electrical Works
Percentage
30 days
Dumka
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
₹77,500
6 Jun 2026
15 Jan 2026
22 Jan 2026
15 Jan 2026
21 Jan 2026
16 Jan 2026
Wiring for light point/fan point/exhaust fan point/call bell point, with 1.5 sq.mm FR PVC insulated copper conductor single core in surface/recessed PVC conduit, piano type switch,phenolic laminated sheet with suitable size PVC/MS box etc as required
c) Group
Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing etc as required.
Wiring for circuit/ submain wiring along with earh wire with the following sizes of FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit as required
a) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire (For light circuit)
b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire ( Computer board wiring)
c) 2 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire (For light submain & computer board submain)
d) 2 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire (for power submain)
e) 2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire ( For LED highway light wiring)
f) 1 x 1.5 sq mm (Inverter wiring)
Supplying and fixing suitable size GI/PVC box of 75 mm x 75 mm x 50 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch. connection, painting etc. as required (For light plugs to be used in non residential buildings )
Supplying and fixing suitable size GI/PVC box of 121 mm x 173mm x 48mm/(6" x 8") (nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch. connection, painting etc. as required
S/F a compact unit made of 8 "*10" PVC box with phenolic laminated sheet cover in front fixed with 3 nos of 5 amps piano type switch and socket, and one nos of 15 amp switch and socket well connected with suitable wire, earthing etc. as reqd. name as computer board.
a) 8" x 6"PVC box - I Nos @ 187.00-187.00
b) 5 Amp switches - 2 Nos @ 32.00 = 64.00
c) 5 Amp socket -2 Nos @ 43.00 = 86.00
d)15 Amp s.s combined 1 Nos @ 112.00 - 112.00
Total 449.00
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
a) 2 way single door (controling for DP MCB DB)
b) 4 way single door ( +54 Nos for Machine)
c) 6 way single door
d) 8 way single door
e) 12 way single door
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 KA, “B” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required.
a) 40 amp DP MCB
b) 63 amp DP MCB
c) 32 amp TPN MCB
S/F PVC/G.I box on surface / recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
72 mm x 146mm x 48mm deep/ (4" x 7") (For 2 WAY MCB DB)
170 mm x 221mm x 48mm deep/ (8" x 10") 22 nos for MCB DP + 4 nos for highway light board)
S/F 2 pin 5 amp. Ceiling rose on the existing junction box etc. as required .
Supplying and fixing Batten / Angle holder including connection etc as required .
Supplying and fixing of following piano type switch / socket on the existing switch box / cover including connections etc. as required.
a) Electonic ste fan regulator Delux
b) 5/6 amps, one way switch ( Controling for highway light)
c) 3 pin 5/6 amps, socket outlet
S.I.T.C of following rating surface mounted LED tube light fitting suitable for 230V 50Hz, single phase supply etc. complete as required.
a) 20/22W LED Tube light
S/F 9/10Watt LED Bulb
S/F 15/16Watt LED Bulb
S/F 80/90W suspended type industrial COB LED highbay light with aluminium die cast heat sink. (For workshop)
S.I.T.C of follwing size ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required.
a) 1200mm (48") Ceiling Fan
S.I.T.C of following rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required
a) 90/100W LED Campus light
Supplying and Laying XLPE indulated PVC sheathed, armoured cable working voltage upto and including 1100 volts. IS:7098, (part-1) of following size
a) 6 sq mm 2 core (For campus light)
b) 10 sq mm 4 core (For motor & Machine)
c) 25 sq mm 3.5 core (From administrative building main panel to sub panel)
c) 25 sq mm 3.5 core (From workshop main panel to sub panel for light distribution)
d) 50 sq mm 3.5 core ( for main panel to sub panel 1 to)
e) 240 sq mm 3.5 core (From transfomer to main panel)
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 185 sq mm but not exceeding 400 sq mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 35 sq. mm to 95 sq mm (clamped with 20mmx3mm GI Tape)
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm in the existing RCC/HUME/STONEWARE/METAL pipe as required.
Supplying and fixing cable junction box without MCB (Make- sintex/hensel or equivalent.
Making 250 mm. clear wide brick drain with cemeant mortar 1:6 with 250 mm. depth 125 mm apron with one brick flat soling plaster CM 1:3 with punning sand filling but excluding earth work in brick drain all complete etc as reqd.
Dismentaling of cement concrete grade M-158 M20 by mannual men with all lift and load.
S/F/F M.S. 40 x 40 x 4 mm IS 2062 Grade A M.S. Angle hoisting steps welded with 6mm dia and 75 mm long M.S. rods anchorage fited in concrote steps at this time of cutting including taxes all complete as per direction of E.I.
Making slab for drain of thickness 4" and width 0.5 mtr with 10 mm rod quantity of 10 mm rod per mtr slab 8 mtr @ 62 kg mtr = 4.96 kg (a) providing RCC M 200 (1:1.5:3) nominal mix per mtr slab 0.1 mtr x 0.5mtr x lmtr 0.05 M3+ carage charge @4%
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Supply and laying 8 SWG copper wire machine body earthing connection
6sq.mm. aluminium lugs
10sq.mm. aluminium lugs
25sq.mm. aluminium lugs
50sq.mm. aluminium lugs
120sq.mm. aluminium lugs
240sq.mm. aluminium lugs
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting/fixing /connection & transportation up to work site, labour charge etc all complete.
100 amps, MCCB 16 KA fixed thermal setting 1 Nos.
LED Indecator lamp R/Y/B/G 3 Nos.
25 mm x5 mm x copper Strip (1.15 kg/mtr) = 8 kg
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting/fixing /connection & transportation up to work site, labour charge etc all complete.
125 amps, MCCB 16 KA fixed thermal setting 1 Nos.
LED Indecator lamp R/Y/B/G 3 Nos.
25 mm x5 mm x copper Strip (1.15 kg/mtr) = 10 kg
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting/fixing /connection & transportation up to work site, labour charge etc all complete. (For main cubical panel workshop)
315 amp MCCB 35 KA, fixed thermal setting = 1 Nos.
150/160 amps, 35 KA, fixed thermal setting = 1 Nos.
125 amps, 16 KA, fixed thermal setting = 6 Nos.
100 amps. 16 KA, fixed thermal setting = 4 Nos.
320 amps, 4 pole changeover switch = 1 Nes.
Digital Volt Mir. (0-500Volt)- 3 phase class 0.5 - 2 Nos.
Digital AMP Mtr. (0-500AMP)-3 phase class 0.5-2 Nos.
LED Indecator lam RY/B/G=6 Nos.
C.T. Coil of C.T. Ratio 300/5 = 6 Nos.
50mm x 5mm copper strips (2.30 kg/mtr) = 22 kg
25mm x 5mth. copper strips (1.15 kg/mtr) = 61 kg
Fabrication and installation of cubical panel with following accessories made of 16 SWG M.S sheet painted with one coat steel primer and two coat power spray painting with approved shade making PCC plinth and foundation including fitting/fixing /connection & transportation up to work site, labour charge etc all complete. (For main cubical panel for administrative building)
150/160 amps. 35KA, fixed thermal setting = 1 nos
100 amps. 16 KA. fixed thermal setting = 4 Nos.
Digital Volt Mtr. (0-500Volt)- 3 phase class 0.5 = 1 Nos.
Digital AMP Mtr. (0-500AMP)- 3 phase class 0.5 = 1 Nos.
LED Indecator lam R/Y/B/G =3 Nos.
C.T. Coil of C.T. Ratio 300/5 = 3 Nos.
25mm x 5mm copper strips (1.15 kg/mtr) 26 kg
Add Labour Cess@1%
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
F2.pdf
Tender Documents • 0.27 MB
BOQ_147276.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .