| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.3 L+₹1.8 L (3.94%)Rejected-Finance SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹49.0 L+₹2.4 L (5.26%)Rejected-Finance GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹49.8 L+₹3.3 L (7.03%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | Rejected-Technical SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | - | Rejected-Technical Not accompanied by scanned copy of requisite DD |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
18 Nov 2024, 6:00 pmClosed
GE (SB) KARWAR
GE (SB) KARWAR
PROVISION OF AIR CONDITIONING IN MEDICAL WARD AND SURGICAL WARD AT INHS PATANJALI AND PROVISION OF AIR CONDITIONING OF SERVER ROOM AT P AND A DEPARTMENT (P 12) BUILDING AT NSRY UNDER GE (SB) KARWAR.
2024_MES_671522_2
8215/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (SB) KARWAR
AS PER NIT
7 documents required · 7 mandatory
₹500
GE (SB) KARWAR
₹94,000
Yes
20 Jan 2025
25 Oct 2024
20 Nov 2024
25 Oct 2024
18 Nov 2024
4 Nov 2024
25 Oct 2024 - 28 Oct 2024
Amount
Supply and fixing floor mounted tower AC of capacity 3.0 TR , high Energy efficiency rotary compressor, copper condensor coil , including outdoor unit stand/ support, indoor unit stand ,LCD remote, separate drainage line to nearest trap, indoor to outdoor cabling, testing complete all as specified and directed.
Supply and fixing 415 V 10 KA 'C' curve MCB of TPN 32 Amp current carrying capacity in the DB complete with connection testing and commisioning complete all as specified and directed.
Supply and fixing TPN 4 Module metal enclosure complete all as specified and directed.
Supply and fixing copper tube 3/8" as per OEM instructions complete all as specified and directed.
Supply and fixing copper tube 5/8" as per OEM instructions complete all as specified and directed.
Supply and fixing insulation for copper tube as per OEM instructions complete all as specified and directed.
Material and labour for PVC sheathed 3 core 2.5 sqmm copper cable as per OEM instructions complete all as specified and directed
Material and labour for PVC sheathed 4 core 2.5 sqmm copper cable as per OEM instructions complete all as specified and directed.
Material and labour for drain pipe 3/4" as per OEM instructions complete all as specified and directed.
Supply and Laying including jointing, testing and commissioning of 4 core 4.00 Sqmm XLPE insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade including provision of lugs, glands etc laid in trenches or fixed on wall/pole or drawn through UPVC pipe complete all as specified and directed.
Supply and Laying or fixing or passing through pipe or in cable ducts,including jointing, testing and commissioning of two run of 3.5 core 150 Sqmm XLPE insulated, armoured, heavy duty, LT UG electric cable with aluminum conductor 1100 volt grade including provision of lugs, glands etc laid in trenches or fixed on wall/pole or drawn through GI pipe complete all as specified and directed . Note - (i) Excavation & earth work, sand cushioning and PCC cover for cable protection will be measured & paid for seperately
Supply, install , testing and commissioning of busbar junction box of suitable size , Indoor type, IP-55 protection, double door,dust and vermin proof made out of 2.00 mm thick MS sheet mounting on MS angle iron 50x50x6 mm size, legs not less than 750mm height and panel board with front and back opening arrangement and locking arrangement complete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 600 amps for three phase 4 wire including the following accessories and fitted in (a) Incoming : (i) MCCB high breaking capacity 4 pole 415 volt 35/50 kA breaking capacity adjustable thermal release range 315 Amps. (ii) Digital type volt meter and amps meter with suitable capacity of CTs of ratio 350/5A , LED indicator lamp and other connected accessories all as directed by the Engineer in charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth for laying/taking out cable and getting out in soft/loose soil all as specified and directed.
Returning filling in soil including spreading leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing excavated material/soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand only will be measured & paid
Supply and lay un-reinforced pre-cast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in replacement of existing burnt bricks complete all as directed.
carrying out horizontal boring below roads / PCC hard standing /Drain by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified as directed.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed by Engr in charge.
Material and Labour for point wiring with two single core 4.0 Sq.mm size multistranded sheathed copper conductor PVC insulated cables and one single core 4.0 Sq.mm size green colour PVC insulated,multistranded copper conductor PVC cable as earth continuity conductor,1100 volts grade, complete drawn in and including rigid PVC CONDUIT and conduit accessories,confirming to IS specifications,concealed in wall/ ceiling /trusses with suitable clamps, screws etc., including 1.22 mm thick MS terminal boxes with 3 mm thick plastic laminated sheet top cover fixed with cadmium plated iron screws for mounting SOCKETS OUTLET 15 Amps multi purpose on independent board including connecting up and testing, all as specified and as directed.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and as directed.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR complete all as specified & directed.
Supply & Fix Voltage stablizer for automatic operation, single phase naturally air cooled indoor type and deisigned for input variation between 170 volts to 250 volts with out put voltage at stablized at 230 volts with accuracy of +/- 2.50% and of capacity 4 KVA complete all as specified and as directed.
Material and Labour for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, 3.5 core ,cross-sectional area 25 sq. mm complete all as specified and directed.
Supply & Fix MCB DB TPN 4 way , double door complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP of 20 Amps current rating complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp rating 415V, 10KA 'C' curve miniature circuit breaker (MCB) TPN of 63 Amps current rating complete with connection testing and commissioning complete all as specified and as directed.
Supply & Fix outdoor stand for mounting outdoor unit of split AC complete all as specified and directed.
Material and Labour for unplasticised PVC pipes of 50 mm dia fixed complete to walls, ceilings or in floors etc., with all pipe fittings such as ends, elbows, unions, tees, reducing tees, adoptors, sockets, plugs, hose clips etc. and fixing to walls etc, complete with saddles (snap clips), wall clips, hooks complete all as specified and directed.
Material and Labour for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
pk Enterprises (BID ID -3163284)
M/s Vijay Airconditioning Pvt Ltd (BID ID -3161798)
BRITE INDUSTRIES (BID ID -3162883)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .