Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹30.8 L+₹2.9 L (10.3%)Rejected-Finance 0 PRAGATIPUR DHARMA SARMA PATH BIRUBARI KAMRUP ASSAM 781016 | KAMRUP METRO | ASSAM | 781016 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.9 L+₹9.0 L (32.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹37.4 L+₹9.5 L (33.9%)Rejected-Finance 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹37.8 L+₹9.9 L (35.7%)Rejected-Finance AZARA THAKURIAPARA AZARA ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
9 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
REPAIR AND MAINT OF ELECTRICAL DISTRIBUTION SYSTEM AND OTHER ALLIED WORKS AT 19 WING, AF AND 14 BRD, AF UNDER GE AF BORJHAR.
2024_MES_638230_1
8398/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category b(i) having deposited Standing Security of Rs 100000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹70,000
Yes
4 Apr 2024
19 Jan 2024
16 Feb 2024
19 Jan 2024
9 Feb 2024
2 Feb 2024
Amount
Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through maually.
Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of lT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
M&L for cement concrete in foundations, filling and mass concreteType C2 1:3:6, 40mm graded aggregate all as specified and directed.
M&L for PCC as in foundation or any other works type C1 (1:3:6) (20mm graded aggregate) all as specified and directed. Note: Any form work required for PCC works are deemed to be included in this rate.
M&L rendering 10mm thick in CM 1:6 on fair faces of brick works or concrete surfaces all as specified and directed.
M&L for taking out of old/ unsv cable of any sizes or types for replacement with new one complete all as specified & directed.
M&L for relaying heavy duty LT under ground cable of any sizes and types in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surface complete all as specified & directed.
M&L for LT Cable fault detection and its rectification by using Cable fault locator machine of span length maximum 2km of cable size 95 to 400 sqmm all as specified and and directed by Engr-in-Charge. Note: Suitable excavation and jointing kit will be measured and paid seperately.
S&L in repair of UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor,1100 Volts grade,cross section area incl taking down of size 300 sq mm 3.5 core complete all as directed.
All as per above item no.12 but size 185 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 150 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 120 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 95 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 70 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 50 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 35 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 25 sqmm 3.5 core complete all as directed.
All as per above item no.12 but size 16 sqmm 4 core complete all as directed.
All as per above item no.12 but size 10 sqmm 4 core complete all as directed.
All as per above item no.12 but size 10 sqmm 2 core complete all as directed.
M&L for boring under roads or any other specified location by reqd T&P without disturbing the top surface of the road for insertion of GI Pipe of 50 to 100 mm dia etc complete all as specified and directed.
M&L for tubes 100 mm bore light grade galvanized with all fittings laid in trenches/ wall/ pole through MS flat (25X3 mm), nut, bolt & washers [ where ever reqd ] of proper sizes for protection cables complete all as specified and directed. Make : Nezone/ Bansal/ Jindal
All as per above item no.25 but bore size 80 mm complete all as directed.
All as per above item no.25 but bore size 50 mm complete all as directed.
All as per above item no.25 but bore size 40 mm complete all as directed.
M&L for replacement of cable duct cover or any other works made up of chequered plate with lifting handle (whereever reqd) including fabrication works such as cutting, welding & bent to shape and painting with two coats of black japan paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of new untreated surfaces complete all as specified and directed.
M&L angle iron / flat bar of required sizes with locking arrangements including fabrication works such as such as cutting, welding & bent to shape and painting with two coats of black japan paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of new untreated surfaces complete all as specified and directed.
M&L for fixing the aluminium terminal in cable end lugs (through corrosion inhibiting compound) of cable size 400 sqmm all as specified & directed. Note: Corrosion inhibiting compound which will be used during crimping of terminal shall be measured and paid separately.
All as per above item no-31 but for cable size 300 sqmm all as specified and directed.
All as per above item no-31 but for cable size 240 sqmm all as specified and directed.
All as per above item no-31 but for cable size 185 sqmm all as specified and directed.
All as per above item no-31 but for cable size 150 sqmm all as specified and directed.
All as per above item no-31 but for cable size 120 sqmm all as specified and directed.
All as per above item no-31 but for cable size 95 sqmm all as specified and directed.
All as per above item no-31 but for cable size 70 sqmm all as specified and directed.
All as per above item no-31 but for cable size 50 sqmm all as specified and directed.
All as per above item no-31 but for cable size 35 sqmm all as specified and directed.
All as per above item no-31 but for cable size 25 sqmm all as specified and directed.
All as per above item no-31 but for cable size 16 sqmm all as specified and directed.
All as per above item no-31 but for cable size 10 sqmm all as specified and directed.
M&L for triming the tree branches falling / touching the HT/LT overhead line in various area of AF Station Borjhar with skilled labours and cutting tools and disposed the branches to a distance not exceeding 50 mtr length complete all as specified and directed.
M&L for replacement of damage/ corroded hinges with new hinges throgh necessary gas / arc welding works complete on the outdoor feeder pillar box/ LT panel/ or any other works complete all as specified and directed.
M &L for replacement of corroded sheet metal doors of outdoor/ inddor feeder pillar box or LT panel with new CRCA sheet of 2 or 3mm thick incl painting the same with two coat of enamel paint of existing shade over a coat of red oxide primer complete incl treatment of new surfaces complete all as specified and directed.
M&L for writing letter, figures, index arrows etc not exc 30 cm in height on LT Panel or any other specified location complete all as specified and directed.
M&L for painting of LT Feeder Pillar Box/ Panel Board or any other plant or equipments by two coat of enamel paint of existing shade after treating old painted surfaces complete al as specified and directed.
M&L for cable jointing kit for 1.1KV grade for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 25 - 50 sqmm complete all as specified and directed. Make: 3M/ Raychem
All as per above item no-49 but size 70-150 sqmm all as specified and directed.
All as per above item no-49 but size 185-300 sqmm all as specified and directed.
All as per above item no-49 but size 400-500 sqmm all as specified and directed.
M&L for cable jointing kit for 1.1KV grade for outdoor straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core PVC/ XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and directed. Make: 3M/ Raychem
All as per above item no-53 but size 185-240 sqmm all as specified and directed.
All as per above item no-53 but size 300-400 sqmm all as specified and directed.
S&F On-Load Manual Change Over Switch (in sheet steel enclosure) 63 Amps 415 Volts, 4 pole after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
All as per above item no-56 but capacity 100 Amp all as specified and directed.
All as per above item no-56 but capacity 160 Amp all as specified and directed.
All as per above item no-56 but capacity 250 Amp all as specified and directed.
All as per above item no-56 but capacity 400 Amp all as specified and directed.
S&F moulded case circuit breaker 80 - 100 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
S&F moulded case circuit breaker 125 - 160 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
S&F moulded case circuit breaker 200 - 250 Amps 415 Volts (with thermal magnetic release), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
S&F moulded case circuit breaker 400 - 500 Amps 415 Volts (with thermal magnetic release), 4 pole 36 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. Make : L&T/ Siemens/ABB = 01 No
S&F Air Circuit Breaker 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps all as directed by Engr-in-Charge.
D.B ENTERPRISE
KUNDAN ENGINEERS AND BUILDERS
M/S PANKAJ SUPPLY SYNDICATE
M/s Lalowari Electricals
Purbanchal Construction Co
M/s JK Jangid and Company
Ms N D Enterpise
R. D. ENTERPRISE
M/s Bikash Das
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .