| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.4 L+₹80,051 (6.89%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹12.6 L+₹1.0 L (8.64%)Rejected-AOC | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹13.9 L+₹2.3 L (19.5%)Rejected-AOC | L4 | Rejected-AOC Not lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
REPAIR MAINTENANCE OF VARIOUS COMPONENTS OF LT OVERHEAD UG NETWORK SYSTEM AND CONNECTED ITEMS AT RMS DHOLPUR UNDER GE BHARATPUR
2020_MES_365936_1
8962/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
RMS Dholpur
Class E category b(I)
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹30,000
Yes
14 Oct 2020
1 Aug 2020
29 Aug 2020
1 Aug 2020
27 Aug 2020
14 Aug 2020
60 days
Amount
M&L for attending, repair and rectification of external LT electric supply compliants on 1100 Volts grade, under ground / over head system alongwith necessary T & P, safety devices as per site requirement for the following type of compliants complete all as specified and directed:- (a) Replacement of wornout jumpers, jointing and tightening with new ACSR conductor .tightening of loose jumpers, rectifying minor faults on LT OH line whenever breakdown occurs, Stringing of/reconnection of broken ACSR conductors, Note:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
(b) Disconnecting U/S connection/terminals of cables from over head conductor, cutting worn outU/S portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same with bininding conductor to restore electric supply. Notes:- (i) LT Jointing kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the Pole coping and inserting the cable along with protection pipes.
(c) Disconnecting faulty/Unserviceable connections of LT cables from MCCB/MCB of LT Panel/DB box , cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables replacement of warn out aluminium lugs including crimping with crimping tools and cable gland from under ground loop line and rejoining the same to restore electric supply. Notes:- (i) Aluminium lugs if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive pattiy item such as insulation tap . (iii) Earth work for loop opening and returniing filling will be included in the quotated rate
Disconnecting the electric connection during fault of O/H LT Line feeder whenever breakdown occurs, clearing fallen tree from O/H Line and Stringing of/reconnection of broken ACSR conductors of O/H Line, Tightening of nuts and bolts of LT insulators if found loose during fault and attending all kind of LT breakdown by deploying suitable Trademen all as specified and as directed by Engineer-in-Charge. Note: Ladder, safety equipment such as gloves, boot, helmet, hanging belt, tools and vehicle shall be arranged by the contractor during breakdown. Note:- (a) Clearing of Fault in one feeder of Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose.
Trimming/prunning and removing of tree branches or any other forein objects from LT /HT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. Notes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. (ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. (iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering and stringing the ACSR conductor etc.
Supply only Alluminium lugs of following sizes (a) 10 sqmm
Supply only pin type reducer Alluminium lugs of following sizes (a) 10 sqmm
Supply only cable gland Double Compression Armoured Weather Brass Cable Glands for following sizes (a) Overall diameter 23mm to 26 mm
Overall diameter 30mm to 33mm
Overall diameter 37 mm to 41 mm
Overall diameter 46 mm to 52 mm
S & F in repairs, LT overhead line PVC separator with accessories viz clamps, screws and locking arrangement for fixing on four conductors system (for 4 wire) complete all as specified and directed.
S & F in repairs, LT overhead line PVC separator with accessories viz clamps, screws and locking arrangement for fixing on two conductors system (for 2 wire) complete all as specified and directed.
Restringing of LT/HT over head line single ACSR conductor of OH line comprising of any size of conductor aluminium/copper/GI after opening binding wire from insulators and replace binding wire and achieved permissible sag limit of over head line conductor complete all as directed and specified. Note- (i) Restringing of line measure one conductor of 3/4 wire OH line . (ii)Rate quoted by the contractor shall be deemed to include for cutting/trimming of tree branches wherever touching the over headline around one metre clear of over head line and removing trimmed branches as directed. Nothing extra shall be paid on this account..
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, and getting out in soft/disintegrated layer complete all specified/directed
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed
Supply and laying of unburnt Sub class B Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length all as specified and as directed by Engineer-in-Charge.
M &L local river sand for bedding and sand cushioning of all HT/LT UG cable all as specified and directed by Engr-in-Charge
M&L for PCC (1:3:6) type C1 using 20mm grade stone aggregate in foundation and mass concrete including necessary form work complete all as specified.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate in coping of existing/new poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and directed.
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Taking out of LT UG cable disconnecting from switch gears, LT poles, pulling out from trenches and walls etc complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 70 Sqmm 3.5core all as specified and directed by Engineer in Charge.
-ditto- as per Ser No-21 here-in-before but of size 50 sqmm x 3.5 core
-ditto- as per Ser No-21 here-in-before but of size 35 sqmmx 3.5 core
-ditto- as per Ser No-21 here-in-before but of size 25 sqmmx 4 core
Supply, laying and testing cable XLPE insulated, screened PVC bedded, galvanised steel stripped or wire armoured electric cable heavy duty with stranded aluminium conductor , 1100Volts grade of size 16 Sqmm 4 core all as specified and directed by Engineer in Charge.
M&L for dismantling of old UNSV ACSR conductors and jumpering any size and type of 2 to 6 run from poles any size and type all as specified and directed.
M&L for stringing ACSR conductor LT Over Head line in Kesarbagh old & new campus and Gundrai feeder 2 to 6 runs of weasel/Mink with permissible sag as per IS rules etc all as specified and directed by Engineer in Charge.
Dismantling of corroded out and broken Cross arms, bracings , nuts bolts, channels and clamping devices etc any size and capacity
M&L for cross arms, bracings, supports, clamps and back plates etc fabricated from structural steel section incl nuts bolts and washers, welding, bending, cold or hot, drilling holes for bolts, in any shape all as specified and directed by Engineer in Charge
Dismantling of old UNSV insulators any size and type all as specified and as directed.
M&L insulator shackle type porcelaine vitreous white/green or brown in colour incl one MS galvanised spindle , iron washers and iron nut bolts of size 100mm hieght , 115mm dia, section of straps 31 x 05mm, for 1100 volts grade all as specified and directed by Engineer in Charge. Make:Jaypuria
M&L insulator pin type porcelaine vitreous white/green or brown in colour incl one MS galvanised spindle , iron washers and iron nut bolts of size 100mm hieght , 65mm dia for 1100 volts grade all as specified and directed by Engineer in Charge. Make: Jaypuria
Supply and lay GI tubing light grade for using in road crossings, poles etc. where ever directed of size 50mm bore all as specified and directed by Engineer in Charge.
Supply and lay GI tubing light grade for using in road crossings, poles etc. where ever directed of size 40mm bore all as specified and directed by Engineer in Charge.
Supply and fixing mild steel galvanised stay assembly set complete comprising of 16 mm dia, 400mm long stay bow, 2150mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including Loop type insulator of vitreous porcelain, small size with overall dimensions 65x90mm, clearance of hole 16mm, all as shown in electrical plate No.1 of MES Schedule part-I 1991 complete including dismantling and taking out old damaged stay complete all as directed NOTE : Excavation & earth work and concrete shall be measured and paid separately under relevant items of this schedule.
M&L for cutting of bituminous road of any type and thick for the width of cut 15cm and depth of cut 30cm for inserting GI pipe 40mm, by using grinder or cutter & refilling the hard core materials and well finishing packed with 100mm thick layer of 1:3:6 ratio PCC cement concrete all as specified and as directed by Engineer-in-Charge
Taking out old U/S LT panel board any size and type from site after dismantling all kind of connections, terminations, cables, lugs, mounting bolts etc and removing from site all as specified and as directed by Engineer-in-Charge.
Design Fabricating supply and errecting connecting and testing totally enclosed LT cubicle panel board 3 Phase 4 wire system outdoor type front and back opening type, ,separate compartment for each control gear,cable alley, provision of knock out type plates for various sizes of cable in and out , incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15 mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour,built in industrial type locking arrangement on front and back ,and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip BusBar for connecting MCCBs ,Panel mounted on Anle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 45 CM below ground level and 15 Cm above ground level and consisting the folowing:- (a) Incoming :- (i)MCCB 4 pole TPN, 400Amps , 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Make Havells/L&T/ABB - 01Nos. (ii) Alluminium Bus bar chamber 4 pole 600 Amp- 1set (iii) Digital Amp meter 0-400Amp with CT- 1set (iv Digital volt meter 0-500 V -1nos (b) Outgoing (i) MCCB 4pole 200Amps capacity, 36KA - 01 No. (ii)MCCB 4 pole, 100Amps capacity, 25KA breaking capacity, 415V- 04 No. (iii) MCCBs 4 pole, 63Amps capacity, 16 KA breaking capacity, 415V - 1Nos Note: space of out going MCCB 1 Nos to be provide and panel mounted on 2' height pcc platform
Taking out feeder pillar box of any size and type from site after dismantling all kind of connections, terminations, cables, lugs, mounting bolts etc and removing from site all as specified and as directed by Engineer-in-Charge.
Supply and Install outdoor type LT feeder pillar box cubical type enclosure size 800mm x 600mm x 300mm, self standing, duly powder coated, front openable Made outof MS sheet ,3.15 mm thick , factory made, with 4 x 400Amp aluminium bus bar for outgoing provided with 4 x branch connection by using nuts and bolts and lugs, comprising the following in incloming: (a) MCCB 4 pole TPN, 160Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Make Havells - 01No. (b) Busbar 4 pole 400 Amp - 1 set
MCCB 4 pole TPN, 200Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 4 pole TPN, 400 Amps capacity, 36KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 3 pole TP, 63 /50Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 3 pole TP,100Amps capacity, 16KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCCB 3 pole TP,200Amps capacity, 25KA breaking capacity, 415V,adjustable thermal & fixed magnetic setting, Ics = 50% of Icu,
MCB TPN 63 Amp 10 KA
M&L for preparation of external surfaces of steel tubular poles / rail pole of height up to 9.5 Mtr above the ground/coping by rubbing sand paper and cleaning, applying two coats of aluminium paint and providing 5 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" wide, complete all as specified and directed.
M&L for preparation of surfaces including painting of RCC poles height up to 9 Mtr of any height with one primer coat and one finishing coat with cement base paint including providing 5 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" widecomplete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in singnal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15cm size.
M&L for preparation of old painted surfaces of LT panel boards and Feeder pillar boxes by using sand papers and applying one coat of synthetic enameled paint through spray gun by arranging compressor at site with adequate power generating set complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00mm dia by means of nuts, bolts, check nuts & washers made of galvanized iron or steel and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1 pre-cast MS sheet cover 30cmx30cmx3.15mm thick with one handle for lifting made out of 8mm dia MS bar, watering pipe 20mm bore galvanized iron pipe (medium grade) with MS funnel for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/dense soil complete all other accessories as shown on electrical plate No 3 of MES Sch Pt-I all as specified and directed.
S&F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts with suitable drivers and included 10KV SPD etc and connecting with 4.0 sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall / pole with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to Pole/Wall in any position with flat iron clamps of size 50 x 6mm including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make:- Crompton Cat Part NoLSTP-60-CDL-Mor equivalent model of Philips/Bajaj/Havells.
Taking out old U/S and corroded out metalic junction box any size and type from pole all as specified and as directed by Engineer-in-Charge
Supply, install, test and commissioning factory made THERMOPLASTIC CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 205 x 255 x 112 mm depth with cable entry size of 10-25 sqmm with 4 pole terminal capacity 100A each, glands including with flat iron clamps of size 30 x 6mm, nuts and bolts. Make Hansel Cat part No:KF 2525 G or equivalent make in /FIBOX(SOLID PC 2528 13G)
S&F cable PVC insulated aluminium conductor of size 6 sqmm, Two core, cut to length all as required at site with thimbles of appropriate size, drawn into conduit/pipe fixed to wall or pole for connection of energy meters to DB etc complete all as specified and directed.
Dismantling and taking down of capacity 45w/ 60w/90w/120W existing street/security LED light fittings for repair/replacement of burnt/worn out assy/ surge protector and refix the same after repair/replacement complete all as directed by Engineer-in-charge.
Supply onlyLED drivers rated voltage 12/24 volt max out put power 75 W code no X075C070V107FNY1BO
Supply onlyLED drivers rated voltage 12/24 volt max out put power 100 W code noX100C070V143FNY1BO
PD GUPTA AND COMPANY
M/S S.S Traders
krishna Associate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .