Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹3.8 L+₹6,661.18 (1.78%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹3.8 L+₹8,583.25 (2.30%)Rejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L3 | Rejected-Finance NOT L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
14 Jul 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer,AMD P.H.E Dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,SEN-RALEIGH ROAD,PASCHIM BARDHAMAN,713305
Replacement of damaged panel spares at Starter for centrifugal Pump No-03 and 04 and Other allied works at Amdohi Boosting Station under Jamgara-Jagannathpur W/S scheme.
2025_PHED_869414_4
WBPHED/EE/AMD/ NIeT-15 of 2025-2026
Open Tender
Miscellaneous Works
Item Wise
30 days
Amdohi
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,000
16 Sept 2025
24 Jun 2025
16 Jul 2025
24 Jun 2025
14 Jul 2025
24 Jun 2025
Amount
Supply and delivery of following materials at site:-
Electronic Over Current Relay range 5-80 Amp, over current, Phase loss, Locked rotor, Phase reversal protection with flush mounted display and ground fault detection system, 100-240 V, AC Control Voltage.(Make:-BCH, Model No-BOCR FEZ80, Cat No:-MP36FEZ80AH)
Plug in type relay 5 Amps Resistive, 24 VDC/240 VAC, (1,00,000 ops) with coil Ohms-9.5 K, coil voltage-240 VAC.(Make-PLA, Model No-MPC 2C 240A 5 Amps L)
On-delay timer with 1 C/O contact, time range 5-100 Secs, 200-240 VAC input.(Make-Approved Make)
Star-Delta timer with 1 NO instant and other 1 NO delayed, 240 V AC, 50 Hz.(Make:-Approved Make)
50 kVAR contactor for capacitor built with auxiliary relay 2NO+2NC, 3 Phase, 415 VAC, 50 Hz.(Make-Approved Make)
3 Pole Power Contactor with auxiliary contacts 2 No + 2 NC, Frame size-S6, with 150 Amp operational current at AC-3 Duty, suitable for Motor rating 75 KW, 415 Volts, 50 Hz, coil voltage 220-240 VAC.(Make:-Approved Make)
Laterally mountable auxiliary switch blocks on left and or right side, with 1 NO+1NC features.(Make:-Siemens, Model No-3RH2921-1DA11)
250 Amps, 3 Pole, molded case circuit breaker with rotary handle arrangements and extended terminals act as a incomer of starter, 415 Volts, 50 Hz.(Make:- Siemens, Model No-3VM1220-4EE32-0AA0(MCCB), 3VM9217-0FK51@(ROM), 3VM9253-0QB50(Extended Terminal))
Illuminated pushbutton, 22 mm, round, flat momentary contact type.(3 Nos RED+3 Nos Green)(Make:-Siemens, Model No-3SU1001-0AB-0-0AA0)
Indicating lamp 220-240 VAC, 50 Hz.(Make:-Siemens, Model No-3SB5285-6HC03)
15 KVAR, Heavy duty capacitor bank, Dimension-(DXH)-105.5 mm X 280 mm, IR=19.68 Amps, CN µF=3 X 82.50.(Make:-Epcos, Model No-B32448A4152B 40)
20 KVAR, Heavy duty capacitor bank, Dimension-(DXH)-121.50 mm X 280 mm, IR=26.24 Amps, CN µF=3 X 109.60.(Make:-Epcos, Model No-B32448A4202B840)
1.5 Sqmm Flame retardant low smoke PVC insulated (Unsheathed) industrial single core multi strand cable with electrolytic grade annealed copper conductor suitable upto 1100 Volts gradeconforming to IS:694.(1 Coil=90 Meter)(Make-Approved Make)
10 Sqmm Flame retardant low smoke PVC insulated (Unsheathed) industrial single core multi strand cable with electrolytic grade annealed copper conductor suitable upto 1100 Volts gradeconforming to IS:694.(1 Coil=180 Meter)(Make-Approved Make)
95 Sqmm Flame retardant low smoke PVC insulated (Unsheathed) industrial single core multi strand cable with electrolytic grade annealed copper conductor suitable upto 1100 Volts gradeconforming to IS:694.(Make:-Approved make)
1.5, 10 Sqmm copper socket pin/Thumb type, PVC sleeve, MCB channel, cable tie, CRC Spray etc for whole erection materials for the installations as per requirement.
6 Amp, SP, MCB with 10kA Isc.(Make:-Approved make).
At first remove the damaged Capacitor contactor, Plug in Relay, Electronic Over Current Realy, MCCB, Power Contactor, indicating devices, relays, timers etc with its release unit from the existing panel after disconnection of all power line.Then fixing the above supplied materials at same place work must be done by Experienced electrician and wholly satisfaction of EIC.
Add GST @ 18%
Add CESS @ 1%
DAS ENTERPRISE (BID ID -6705179)
EASTERN INDIA SALES AND SERVICE (BID ID -6701579)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .